Jungheinrich error e0305

Поділитися
Вставка
  • Опубліковано 25 сер 2024
  • Jungheinrich electric pallet truck error e0305 sometimes it can only be a small thing like a defective fuse. there are two fuses 100A and 150A. I had a defective 100A fuse

КОМЕНТАРІ • 24

  • @chungkaryee8331
    @chungkaryee8331 Рік тому +1

    Hi, do you know the error code E 1953 for pallet truck EJE120 ? Lifting is ok, but if want to move, i have to press the turtle slow button.

    • @AuVietForklift
      @AuVietForklift 5 місяців тому +1

      Shunt button no fixed when you install control head upper

  • @cerssalsa
    @cerssalsa Рік тому

    hello men, one questions, yu know any about code E1104, this truck no drive, no lift, tks

    • @repairityourself
      @repairityourself  Рік тому

      hello I'm not sure but I think the controller is the problem

    • @cerssalsa
      @cerssalsa Рік тому

      @@repairityourself tks, bro, i have same idea

  • @loryrenzu98
    @loryrenzu98 26 днів тому

    ciao ho un codice di errore E 1925 non riesco a levarlo che cose

  • @danielmihalache617
    @danielmihalache617 9 місяців тому

    Hello how can i fund The parts catalog for eje 116.

    • @repairityourself
      @repairityourself  9 місяців тому

      Hello.Getting a parts catalog or any service documents from Jungheinrich is not that easy, but there are many sites on the Internet that sell spare parts for forklifts and electric pallet trucks from various manufacturers

  • @farazmunir6553
    @farazmunir6553 Рік тому

    Hi could I ask if the truck was functions where still working. I have the same error but every now and again the truck keeps cutting out

    • @repairityourself
      @repairityourself  Рік тому

      Hello. Works and no more error

    • @farazmunir6553
      @farazmunir6553 Рік тому

      @@repairityourself I have the same error. The truck works but keeps cutting out when driving. Do you know what it could be?

    • @repairityourself
      @repairityourself  Рік тому

      First you should check if the main fuse is ok. If yes, check the power switch. After that, check the battery electrolytes and cables, as well as the controller. This error appears as a voltage-related error.

    • @farazmunir6553
      @farazmunir6553 Рік тому +1

      @@repairityourself thankyou so much for the help.

  • @dwusuwowy
    @dwusuwowy Рік тому

    Hi. Jungheinrich ERE225 - error E 3102. No drive, no stering, lift OK.

    • @repairityourself
      @repairityourself  Рік тому +1

      Hello. Check the cable from the handle to the controller

  • @joshkrebsbach8393
    @joshkrebsbach8393 Рік тому

    Any idea what a e 4506 is?

  • @huseyinderebasi-kz8ky
    @huseyinderebasi-kz8ky Рік тому

    Hello Error 4372

  • @auttaphonkeanyuak4991
    @auttaphonkeanyuak4991 7 місяців тому

    Eror0305

  • @ottomancchabouti5475
    @ottomancchabouti5475 Рік тому

    Erreur 0102

    • @repairityourself
      @repairityourself  Рік тому

      Self test Contactor contact closed instead of opening When switched on, the capacitor voltage should be one volt (1 V) below the battery voltage. - Check the output of the main contactor of the control system; - check the wire connection; - replace the contactor; _ 1 2 Self-test Contactor contact open instead of closed After contactor activation, the capacitor voltage must be equal to the battery voltage (within 500 ms.), otherwise an event message is triggered. - Check the output of the main contactor of the control system; - check the wire connection; - replace the contactor; _ 1 3 Self test Main contactor permanently on. An attempt is made to open the main contactor. The event message is triggered when the controls detect after T> time limit that the main contactor does not open. - Replace the control system; Lithium-ion battery 24 V/110 Ah (in case of repeated occurrence): - Check the cable harness of the lithium-ion battery, replace it if necessary; - replace the battery contactor; - replace the battery management system (BMS); _ 1 4 Self test Mode of operation Main contactor feedback input to set state implausible Status of the feedback signal for activation of the main contactor implausible (initiation of error after the time limit) - Check the main contactor output of the control system; - check the wire connection; - replace the contactor;

    • @repairityourself
      @repairityourself  Рік тому

      Sometimes cleaning the contactor helps.