Fitting Multiple Spectra with Peak Analyzer

Поділитися
Вставка
  • Опубліковано 8 січ 2025

КОМЕНТАРІ • 18

  • @linusgrote941
    @linusgrote941 4 роки тому +1

    "Save Theme as..." not found.
    When I click on the lock-icon on the report sheet as done at 4:43 after I have done the peak fitting, I do not have the option to select "Save Theme as...". I also do not have the options to select "Block Recalculation" and "Ignore Hidden Rows". Does somebody know why that is? What did I do wrong until this point?

    • @TheOriginlab
      @TheOriginlab  4 роки тому +1

      Hi Linus, Thanks for your question. Regarding "Block Recalculation" and "Ignore Hidden Rows", these are newer features, so your version may not have them. But as for "Save Theme As" this has been around for many versions. Could you please email us at tech@originlab.com so we can further look into it? Please include the version you are using and your serial number.

    • @TheOriginlab
      @TheOriginlab  4 роки тому +1

      To download a free trial of our latest version please visit www.originlab.com/try .

    • @linusgrote941
      @linusgrote941 4 роки тому +2

      @@TheOriginlab Hello, thank you very much for the answer! I found another way to save the theme by clicking the top right arrow in the peak fitting dialog just before closing. This should be the same.
      Kind regards

  • @hasnahamdane4106
    @hasnahamdane4106 4 роки тому +1

    Hello, thank you very much for this useful video.
    How to solve this problem?
    ''Fit did not converge. Maximum iteration setting of 200 was reached.''
    Kind regards

    • @TheOriginlab
      @TheOriginlab  4 роки тому

      Hello Hasna, Thanks for the question, however, we would really need to better understand your case before answering. Please email us at tech@originlab.com and our tech support team can work with you. Please include the version you are using and your serial number. Best, OriginLab

  • @abbashadjabbas
    @abbashadjabbas Рік тому

    Can we fitting the FTIR Spectra with transmittance like this method or there is another method?

    • @TheOriginlab
      @TheOriginlab  Рік тому

      Yes, the Peak Analyzer tool can identify and fit negative peaks too.

  • @merveaktan210
    @merveaktan210 4 роки тому

    How did you define FWHM? When I apply lower bound as 20, upper as 100, I can't see my fitting peaks anymore.

    • @TheOriginlab
      @TheOriginlab  4 роки тому

      Hello, We would need to better understand your case before answering. Please contact us www.originlab.com/contactus

    • @elizabethmeghana9614
      @elizabethmeghana9614 3 роки тому

      How did u fix FWHM for your data ?

  • @brunobach1979
    @brunobach1979 2 роки тому

    after Baseline Treatment the graph disappeared! How to solve this problem?

    • @TheOriginlab
      @TheOriginlab  2 роки тому

      Is it because you didn't check Auto Rescale on Baseline Treatment page? Try Ctrl+R to rescale the axis range. Thanks.

  • @Zigislam
    @Zigislam 2 роки тому

    How will i change the gaussian function to Laurentz in batch fitting

    • @TheOriginlab
      @TheOriginlab  2 роки тому

      For technical support, please visit www.originlab.com/support

  • @sergiotello4346
    @sergiotello4346 Рік тому

    Hello! How can I eliminate a Theme name or to change it?

    • @TheOriginlab
      @TheOriginlab  Рік тому

      For technical support, please visit www.originlab.com/support.

  • @michaelwaymire2037
    @michaelwaymire2037 4 роки тому +1

    GG