Thanks sir , please make a video how to connect wirring hart communicator with transmitter in field wiring running plant also equalizer vale which one is open or close?
@@instrumentsolutionsbrother mera ek question hai please answer do:- instrumentation ka pm work ke liye jo isolation hota hai wo online kehlata hai, online ka matlab kya hai? pls
Sometime slurry type flowing substance ho to wo bhi tx sensor side sticks kr jata he to us case me bhi tx fluctuate ki problem aati he ... Us case me purge plug losse krke drain kriye ... Or impulse tube to bhi dekh lena chahiye khi wo to chock nhi he ..... Or ha tx ki working or sensor sensitivity ko 1) under pressure zero check 2) without pressure zero check Se check kr skte he
Dear sharif khan ji multimeter ko MA me selection kre ... Uske bad tx me test ka terminal hota he ... + Wire ko remove krke ek lead us wire pr lgae or ek lead test pr or MA check kre 👍 Is type se MA check krne ko series me MA check krna bolte he 👍
Thanks for teaching my friend, I very like this video
Most Welcome sir 🤗
It's been a long time since I saw you👍🏻
Great job,Keep it up brother.
Thank You so much 👍
Very good sir nice information 👍
Thank You so much 👍
Thank you very helpful
Welcome 🤗
Useful information 👍
Thank You 😊
Ha
Good information
Thank You 🙏
Nice explaination
Thanks🤗🤗
Thanks🤗🤗
Thanks sir , please make a video how to connect wirring hart communicator with transmitter in field wiring running plant also equalizer vale which one is open or close?
Ok
Good video.... What is damping in flow meter?
Thanks.
If any transmitter fluctuates too much, then transmitter's fluctuation is reduced by damping.
Good job veer ji
Sukran brother.
❤️❤️
@@instrumentsolutionsbrother mera ek question hai please answer do:- instrumentation ka pm work ke liye jo isolation hota hai wo online kehlata hai, online ka matlab kya hai? pls
thank you
Welcome 🤗
Sir aur jo comment mai kiya hu sayad hahi sawal bhai logo k mann mei bhi chala hoga
Thanks 🙏
Wooow sir nice
Good I need video about analyzer bro
Already I have please check
Nice 😊😊
Thanks
Sir gun elevation ke upar ek video banaiye
Good video sir,,,
Thank you
Good
Vibration prob sensor ka calibration par video banaye sir please
Sir aap kon si industry me work kerte ho & location kya he
Bibiyana 400MW ccpp project, Bangladesh
Bhai abhi last project me damping 10 sec set Kiya, ye damping kis chiz pe depend krta hai, kitna dalna hai wo kaise malum chalega
Please How to know the level of a closed tank if thy are an erreur in the transmetteur
Damping kya hota hai sir
Damping kis liye karty hain?
If value is more fluctuates then
If transmitter fluctuation not solve after damping set then what will be the issue?
Ok
Sir fluacting problem sirf damping hi nhi ho skta h. Kuch reason aur bhi h. Apke knowledge ke hisab se jo aur reason h o bhi bataiye
Ok
I will give another video
Sometime slurry type flowing substance ho to wo bhi tx sensor side sticks kr jata he to us case me bhi tx fluctuate ki problem aati he ... Us case me purge plug losse krke drain kriye ... Or impulse tube to bhi dekh lena chahiye khi wo to chock nhi he .....
Or ha tx ki working or sensor sensitivity ko
1) under pressure zero check
2) without pressure zero check
Se check kr skte he
@@ashishgautam9189 What is impulse tube?
Thanks.
@@cck1496 impulse tube means primary elements ( process side) se instrument side tk jo tube connected he usse hum impluse tube bolte he
@@ashishgautam9189 Thanks for the clarification. Appreciate.
What is course i can do for to get job in PLC
Sir pt 8bar so Kar Raha hai lekin 22ma current aaraha hai yani bad so Kar Raha hai to esaki problem kiya ho Sakata hai
Sir transmitter me out put signal 4 to20 mili apr kese check kare please video banaye thanks
Ok I will give
Dear sharif khan ji multimeter ko MA me selection kre ... Uske bad tx me test ka terminal hota he ... + Wire ko remove krke ek lead us wire pr lgae or ek lead test pr or MA check kre 👍
Is type se MA check krne ko series me MA check krna bolte he 👍
❤❤❤
Transmitter mei Hart communicator ka option nahi hai to kaise solve karna hai sir.
Bro tamil la translation panna mudiuma bro
Pressure transmitter me module fail show kar raha hai
If Transmitter is ok then Maybe problem in module
Calibration sikhana Hai Mujhe
Bhaiya ap ka number dijiye na, plant agar problem hoga toh call karunga
Video bhejiye WhatsApp per
Hamre number bar baat Karo bhai
Yah mera WhatsApp number hai
Very good sir nice information 👍
Thank You so much 👍
Good job