All AC Motor winding data calculation complete details with Example🔥🔥

Поділитися
Вставка
  • Опубліковано 9 вер 2024
  • How to calculate number of turns in Stator of 3 Phase Machine with example ????
    ***********************************************
    All Motor Winding data calculation in Complete detail in Hindi
    #allmotorwindingdata
    #acmotorwindingdata

КОМЕНТАРІ • 254

  • @omprakashtiwari9492
    @omprakashtiwari9492 2 роки тому +3

    Absolutly correct calculation
    Based on engineering. Thanks

  • @stanmcdonald
    @stanmcdonald 3 роки тому +2

    Could you redo this video in English. Lots of good info but missing alot due to language issue. Most replies are also in English therefore you have interest. This is one of the best videos I have seen.

  • @mahendraprajapat6868
    @mahendraprajapat6868 3 роки тому +1

    Bahut hi helpful video 👍

  • @abdullahhanan5807
    @abdullahhanan5807 3 роки тому +2

    Thanks

  • @mahendraprajapat6868
    @mahendraprajapat6868 3 роки тому +1

    Thanks for example sir

  • @bijoyghosh8351
    @bijoyghosh8351 2 роки тому +1

    Dear Sir, please dc motor ka winding calculation ke ek video banaiye.thank you Sir.

  • @rizwanalinaimi2544
    @rizwanalinaimi2544 3 роки тому +2

    Sir BLDC Moter/fan winding calculation bhi btao please

  • @bhindajatt2422
    @bhindajatt2422 3 роки тому

    Nice bhut acha videos es ke jarurt thi .....koi v empty 3ph ja 1ph ke motor kahli motor uska winding data nikalna or bariya method c clear karo.....punjabi jatt.

  • @electricaltechnicalknowled6820
    @electricaltechnicalknowled6820 3 роки тому +1

    Nice sir

  • @saruaralam440v
    @saruaralam440v 9 місяців тому +1

    I want same more videos

    • @DineshChandra
      @DineshChandra  9 місяців тому

      Dear, You can check playlist for 1 phase and 3 phase

  • @bittuelectricalwork387
    @bittuelectricalwork387 Рік тому

    Sir please make video on field winding turns and wire gauge calculation of alternator

  • @muasabumair8754
    @muasabumair8754 Рік тому +1

    Motor 10hp
    Slot 36
    Core lambai 150mm
    Stater bore 135mm
    Volt 400
    Rpm 1440
    Kindly data please!!!

  • @bijoyghosh8351
    @bijoyghosh8351 3 роки тому +2

    Dear Sir, kya ceiling fan coil winding me bhi kw (0.954) ka yehin sankhya dena parega, please Sir help me. Thank you.

  • @amrutenergy1644
    @amrutenergy1644 26 днів тому

    Can you tell how you take flux density 0.48 ?

  • @bittuelectricalwork387
    @bittuelectricalwork387 2 роки тому

    Sir single phase motor turn calculation bataye with example

  • @Questionmark47789
    @Questionmark47789 Рік тому

    Single phase ka formula bataye

  • @RaviKumar-rk1gr
    @RaviKumar-rk1gr 2 роки тому +1

    Sir mere pas 3 hp Singla compani motar hay mono block 1 phesh 2800 rpm 220 volt 24 slot winding data bta dijiye sir pleas

  • @ransingdeshwal6989
    @ransingdeshwal6989 2 роки тому

    Sir singel phase 3hp motor atta chakki. Ki video banaye

  • @SaifulIslam-vs1tt
    @SaifulIslam-vs1tt 3 роки тому +1

    Video very very nice sir. Sir ak question. Ac Janarator 5kava jiska armicher roted. Fill fixed. Armicher swg. Fill swg. Calculation. Or example.

    • @DineshChandra
      @DineshChandra  3 роки тому +1

      Thanks
      Just wait bahut jaldi isper video aayega

    • @SaifulIslam-vs1tt
      @SaifulIslam-vs1tt 3 роки тому

      @@DineshChandra thanks sir

    • @DineshChandra
      @DineshChandra  3 роки тому

      Generator Rating 5kva ke sath voltage rating kya given hai ?? Jese Line voltage or Phase voltage

    • @SaifulIslam-vs1tt
      @SaifulIslam-vs1tt 3 роки тому

      @@DineshChandra sir. Core lanth6. " round16" Suplayr voltag 230. Amp20 p.f. 0.8

    • @SaifulIslam-vs1tt
      @SaifulIslam-vs1tt 3 роки тому +1

      @@DineshChandra single phase. 3phase example

  • @electricaltechnician8638
    @electricaltechnician8638 2 роки тому +1

    Sir explain the same video for single phase motor

    • @DineshChandra
      @DineshChandra  2 роки тому

      Dear you can watch it in single Phase playlist

    • @maltiengineering9929
      @maltiengineering9929 2 роки тому +1

      where is single phase play list

    • @DineshChandra
      @DineshChandra  2 роки тому

      @@maltiengineering9929 ua-cam.com/play/PLcFVUpmooFKoebFGD1m--OAaVfEmmZ85a.html

  • @jamyousif8066
    @jamyousif8066 9 місяців тому

    0.954 is not KW its a winding factor that are decided on the base of slots/pole/phase

  • @virajitgundale4382
    @virajitgundale4382 2 роки тому +1

    YOu have any video for Single phase motor ?

    • @DineshChandra
      @DineshChandra  2 роки тому

      Yes you can check it in playlist

    • @virajitgundale4382
      @virajitgundale4382 2 роки тому

      @@DineshChandra I want to find out Core length for Single Phase Motor 24 Slots 2800

  • @Dave_en
    @Dave_en 3 роки тому +1

    Maine formula ko simple bana diya hai.
    Turns per pole =7.5*voltage per pole/(effective area of pole in sq inch)
    Results approx same aayenge.
    Isi tarah maine kaafi saara cooler, farrata aur exhaust fan ka winding data practically verify kar chuka hu.
    Aap apne formula se bhi ye 7.5 ka constant derive kar sakte ho.

    • @Anoopkrsingh-pn7wc
      @Anoopkrsingh-pn7wc 3 роки тому

      Sir can you share your contact. I need exact formula i did 4-5 winding from my formula but not getting satisfactory result.

    • @Dave_en
      @Dave_en 3 роки тому

      @@Anoopkrsingh-pn7wc Aap voltage 240 le lo.
      D=inner diameter
      L=stator length
      Tph=turns per phase per pole
      Tph=15.7*240/(πDL)
      D aur L inches me honge.
      Jo answer aayega, usko 0.9 se divide karenge 4 pole ke liye. 2 pole ke liye 0.95 se divide karenge.
      Isse kam turns nhi rakhna hai warna heat hoga.

    • @Dave_en
      @Dave_en 3 роки тому +1

      @@Anoopkrsingh-pn7wc
      Example se samjhata hu.
      Inner dia=3inch
      Length ya thickness=1 inch
      Line voltage=240
      Pole =4
      Turns per pole=15.7*240/(π*3*1)=399.79
      4 pole ka motor hai toh 1-4 ek round, 1-6 do round karna hoga.
      Yaani total 3 rounds.
      Toh coil ka turn hoga=399.79/3=133.266
      Ab winding factor 0.9 hota hai 4 pole ke liye.
      Toh coil ke turns adjust karenge 133.266/0.9=148.073
      Isko round figure me 150 turns ki maala ya laccha bana sakte ho.

    • @Anoopkrsingh-pn7wc
      @Anoopkrsingh-pn7wc 3 роки тому

      @@Dave_en Waah guru yaar thank you mai try karta hu ispe.
      Sir aap se baat ho sakti hai kya

    • @Dave_en
      @Dave_en 3 роки тому +1

      @@Anoopkrsingh-pn7wc
      Agar farrata fan hai toh.
      D=2.5 inch
      L=0.75 inch
      2 pole
      Turns per pole=15.7*240/(πx2.5x0.75)=639.675
      Isko 1-8, 1-10, 1-12 ka pitch lena hai toh 639.675/3=213.225 turns hoga.
      Winding factor 0.95 lena hoga
      Toh turns honge 213.225/0.95= 224.44
      Aap 230 turns le sakte ho.
      Ab agar isko kisi bhi company ke data se compare karte ho toh bahut close aayega.
      Iss specification ke farrata fans me 220, 230 ya phir 240 tak turns paaye jaate hain main winding me.
      Cooler ke fan jo 1 inch thickness wala stator hota hai, uss me humesha 150 turns ka hi laccha banaya jata hai.
      Ab itna verify ho gaya toh aap kisi bhi motor ka data nikaal loge.

  • @shafeeqahmadchaduhary2946
    @shafeeqahmadchaduhary2946 2 роки тому

    Do you count number of turns of existing coils before rewinding or calculate. What is normal practise.

  • @jassachahal7368
    @jassachahal7368 3 роки тому +1

    Sar garnoter ka winding data kese niklte he wier number tarn or continues ka pora data batana kitni core length me kon sa data lagega pless jankari dena 3 fej or 1fej me or motar ka swg kese malam hoga jankari dena

  • @shashidharmandal5416
    @shashidharmandal5416 3 роки тому

    Sar ji aur bhi shortcut trick bataen

  • @debdulalkhatua3904
    @debdulalkhatua3904 Рік тому

    স্যার 220 ভোল্ট সিঙ্গেল ফেজ টু এইচপি মোটর দেখান উদাহরণস্বরূপ দেখান

  • @dayanandkasle5146
    @dayanandkasle5146 8 місяців тому +1

    Wire gauge

    • @DineshChandra
      @DineshChandra  8 місяців тому

      Sir aap playlist me check kr skte ho procedure

  • @dipakrane3659
    @dipakrane3659 2 роки тому

    Sr submersible motor ka winding data nikalne or restanse nikalne ka formula bataye

    • @DineshChandra
      @DineshChandra  2 роки тому

      Aap iss formula se try kro aur cross verify krke dekho mere pass available hoga toh m jarur bataunga apply krke

  • @allwyn01
    @allwyn01 2 роки тому

    Motor Rpm 780
    Stamping length - 35 mm
    Stator ID - 70mm
    Stator OD - 120mm
    No of slots - 36
    No of coils - 6 + 6
    Hp - 68 watts
    Amp - 0.6 amps
    230V , single phase ,
    Aluminium winding
    Connection 3 wire
    Starting coil SWG 27
    Pitch 1-4 and 1-6
    Turns 95 and 190
    Total weight of coils - 150 gm
    Running coil SWG 29
    Pitch 1-4 and 1-6
    Turns 130 and 260
    Total weight of coils - 150 gm
    Question
    Is this collected data correct
    What type of coils I need to make
    What will be the copper equivalent to above
    What size insulation paper how many mils

  • @pronobpaul6984
    @pronobpaul6984 3 роки тому

    Sir up armature trans formula dijiya

  • @BSP00
    @BSP00 2 роки тому +1

    Wb value 0.48wb/per meter h to cm ko meter me me convert karne par 100 se divide➗ karna padega ya 10 ki power mines 4 se 10 ki power mines four samghaye

    • @DineshChandra
      @DineshChandra  2 роки тому

      Flux equal to flux density and area hota hai aur area hamesa 100 se 2 bar division krne ka matlab 10 ki power 4 hota hai

    • @BSP00
      @BSP00 2 роки тому

      Ok

    • @BSP00
      @BSP00 2 роки тому +1

      Thanks

    • @BSP00
      @BSP00 2 роки тому

      Single phase 22 mm stater lenth , 50 mm id , four pole , 16slod please calculate ,single fhase me no. Of conducter 2*3*212/24slod samagh nahi aaya

  • @industrialautomationbymk
    @industrialautomationbymk Рік тому +1

    Single phase motor data calculation 😭 Plz🙏⚡💡

  • @digvijaykumar5320
    @digvijaykumar5320 2 роки тому +1

    πD²/4 D ka matalab sir diameter hota hai ² ka matalab sir 2×2 hota hai π 3.14 hota hai 4 ko bhag Dena padega

  • @charansingh1286
    @charansingh1286 5 місяців тому

    DC Motor RPM calculation formula sand

  • @ketanbhaipatel9900
    @ketanbhaipatel9900 2 роки тому

    Sir muje penal fan banahe Jo idastris me use hotahe pura disain bana ne ka formu la batavo

  • @kentoy5598
    @kentoy5598 2 роки тому +1

    This is applicable for single phase motor?

    • @DineshChandra
      @DineshChandra  2 роки тому

      You can check all video in following playlist thanks
      👉 ua-cam.com/play/PLcFVUpmooFKoebFGD1m--OAaVfEmmZ85a.html

  • @digvijaykumar5320
    @digvijaykumar5320 2 роки тому

    Sar single phase motor ki running starting donon data kaise nikal sakte hain single phase motor ek video banaaiye sar

    • @DineshChandra
      @DineshChandra  2 роки тому

      Aap iske liye single Phase ki playlist dekh lijiye aapko idea ho jayega

  • @gajendramasurkar5388
    @gajendramasurkar5388 Рік тому +1

    मोटर के तार का गेज कैसे निकाले

  • @deepaksubedi7623
    @deepaksubedi7623 3 роки тому

    Very good information sir , which book have all formula i want buy book

    • @DineshChandra
      @DineshChandra  3 роки тому

      Thanks

    • @deepaksubedi7623
      @deepaksubedi7623 3 роки тому +1

      @@DineshChandra welcome sir nobody given to good new & good education but your video given to good information

    • @DineshChandra
      @DineshChandra  3 роки тому

      Thanks for all keep in touch 👍

    • @coclover1004
      @coclover1004 2 роки тому

      @@DineshChandra sir aaap caliclate dyaan sa dekhna yaha 10 ki power 4 ki ha baha dekho apna thoda galat kiya h

  • @technicalbaby7427
    @technicalbaby7427 2 роки тому

    Sir cooler motor design kaise karenge please help me

  • @helloshankarsoni3510
    @helloshankarsoni3510 2 роки тому +2

    You mentioned the turn per slot, but didn't cpecify the wire gause and the size of the slot.

  • @parvezbaig8345
    @parvezbaig8345 2 роки тому +1

    What is window space vector??

  • @upendrasharma3233
    @upendrasharma3233 2 роки тому

    Sir good evening mere ko singal phase motor winding data ka video dale

  • @arunverma7752
    @arunverma7752 2 роки тому

    Sir is ke bare me thoda aur vistar se samjha do Hindi me 🙏🙏

  • @arslanhashmi3333
    @arslanhashmi3333 3 роки тому

    Sir is ma jo wire nilly gi is k connection seres hi hun gy

  • @laljikumar3676
    @laljikumar3676 2 роки тому +1

    Star me eph kitna lete hai aur Delta me eph kitna lete hai sir

    • @DineshChandra
      @DineshChandra  2 роки тому

      ua-cam.com/video/FG1MuPl55bg/v-deo.html

  • @digvijaykumar5320
    @digvijaykumar5320 2 роки тому +1

    Sir motor winding data calculation se nikalne par motor kor Jada heet to nahi kare gi

    • @DineshChandra
      @DineshChandra  2 роки тому

      Ye sabhi aap apni original motor ke data se verifiy kr skte ho uske baad aapka koi doubt nhi rahega

    • @digvijaykumar5320
      @digvijaykumar5320 2 роки тому

      @@DineshChandra sir hame nai motor design karna ho to aur vah data nahin sahi ho to

    • @DineshChandra
      @DineshChandra  2 роки тому

      @@digvijaykumar5320 iske liye aapko aur bhi kafi data ki jarurat hogi jese core material, area of core, space for winding , rotor slot angle jo ki design software ke bina possible nhi hoga

    • @digvijaykumar5320
      @digvijaykumar5320 2 роки тому +1

      Sar motor ki length aur ID aur OD aur voltage aur kw Aur hp aur Pol Dene par hamare liye winding data nikal sakte hain sir

  • @pronobpaul6984
    @pronobpaul6984 3 роки тому

    Ganarator ka armature ka trans kasha nikala uska carect formula dijiya sir

    • @DineshChandra
      @DineshChandra  3 роки тому

      ua-cam.com/video/b0q7852KKuc/v-deo.html

  • @kavitapatel958
    @kavitapatel958 3 роки тому

    Sir. Ek motor 3phase 150w d rpm 2800

  • @ravishanker272
    @ravishanker272 3 роки тому

    Sir गेज कैसे निकाले

  • @prempalsingh5266
    @prempalsingh5266 3 роки тому +1

    Sir singe phase ke moter hi jiska lenght 1.5 inch aur d 2 inch hi pole 2 iska swg aur turns batya

  • @debdulalkhatua3904
    @debdulalkhatua3904 Рік тому

    Sir 2hp sangal ph . ।।

  • @Mysaurabh2
    @Mysaurabh2 2 роки тому

    Sir mujhe submersible ka data kaise nikalte hai wo janna hai 3 phase 2phase 1phase 1hp,2hp 3hp,or 5 hp ka plzz btaye

  • @chandumujum6904
    @chandumujum6904 3 роки тому

    3phase motor tern calculat krki dekhai per s.w.g neekalk with pritcal krki dekhae

  • @digvijaykumar5320
    @digvijaykumar5320 2 роки тому +1

    Sar ham starting ka winding data calculation kaise karen

  • @arslanhashmi3333
    @arslanhashmi3333 Рік тому

    Ba bari moter ka kitna ho ga

  • @laxmangopale2455
    @laxmangopale2455 3 роки тому +1

    Sir live Example pz

  • @santoshnaik2716
    @santoshnaik2716 3 роки тому +1

    Please sir can you explain me how it Bm=Bav
    0.48wb/m2

    • @DineshChandra
      @DineshChandra  3 роки тому +3

      Flux density depends upon permeability of material and Flux =Flux density × Area or B= Flux/Area ,if you increase area of core flux density reduce, according to design of machine it varies between 0.40 to 0.55 so I considered average value between these two

    • @santoshnaik2716
      @santoshnaik2716 3 роки тому

      @@DineshChandra thank you sir

    • @DineshChandra
      @DineshChandra  3 роки тому

      @@santoshnaik2716 most welcome , keep in touch

    • @baktiprapdanu536
      @baktiprapdanu536 2 роки тому

      There is a table about flux density sir ?

    • @Dave_en
      @Dave_en 2 роки тому +1

      @@baktiprapdanu536 generally a value between 0.3-0.6 may be taken for practical applications. But these two values are extreme and doesn't give optimum output. So middle path is taken which gives best performance and durability. You can assume 0.45 Wb little more or less. For smaller size stator, increase it to 0.48 or 0.5 and for larger stators, 0.4 would be good enough.
      For 1HP motor, flux density of 0.45 Wb/m^2 is best value to start with.

  • @sandeepsupakar8456
    @sandeepsupakar8456 3 роки тому +1

    Please provide link for single phase motor

  • @manojpanwar8234
    @manojpanwar8234 2 роки тому

    1a

  • @pratikredekar2625
    @pratikredekar2625 3 роки тому

    Sir mujhe scratch se motor design Karni hai toh Woh kaise Kare please help

  • @shresthaarjun4486
    @shresthaarjun4486 2 роки тому

    Sir koi application he data ke liya

  • @akashsenta3601
    @akashsenta3601 3 роки тому +2

    How to find winding wire SWG

    • @DineshChandra
      @DineshChandra  3 роки тому

      Please check Play list 👍 sir

    • @Anoopkrsingh-pn7wc
      @Anoopkrsingh-pn7wc 3 роки тому

      @@DineshChandra hello sir kya aap whatsapp no. Share kar sakte ho mujhe sikhna hai sir single phase motor winding.

    • @DineshChandra
      @DineshChandra  3 роки тому

      @Anoop kr. singh I will share all information related to electrical machine in upcoming videos. So keep watching

    • @jbpowertronics7719
      @jbpowertronics7719 3 роки тому

      Z power 3 Kya hi

  • @satyendrasharma6919
    @satyendrasharma6919 2 роки тому +1

    फ्लकस का मतलब क्या होता है शर

    • @DineshChandra
      @DineshChandra  2 роки тому

      You can watch this video
      ua-cam.com/video/VMKoJ2I6Js4/v-deo.html

  • @forlife3452
    @forlife3452 3 роки тому +1

    swg konsa dalna he

  • @lokeshsharma-go9ht
    @lokeshsharma-go9ht 3 роки тому +1

    🙏🙏🙏🙏🙏🙏

  • @digvijaykumar5320
    @digvijaykumar5320 2 роки тому

    Sir 2hp motor me running winding mein double tar Winding kar te hai formula se hi double tar nikalti hai 2hp motor me double tar kaise nikal te hai sir please bataen

    • @DineshChandra
      @DineshChandra  2 роки тому

      Aap wire ki size nikaliye kitni chahiye uske liye alag se video banaya hua hai

  • @kelechiarinze7977
    @kelechiarinze7977 9 місяців тому

    English please

  • @mdabushaidabushaid1336
    @mdabushaidabushaid1336 2 роки тому

    vaia aktu bangla te tutorial koren

  • @digvijaykumar5320
    @digvijaykumar5320 2 роки тому +1

    0.48*103.12*10-4 sir samajh mein nahi aa rha hai please sir bataen

    • @DineshChandra
      @DineshChandra  2 роки тому

      Diameter aur length ko meter me badalne ke liye 10-⁴

    • @digvijaykumar5320
      @digvijaykumar5320 2 роки тому

      @@DineshChandra sir calculator kaise karen wahi nahi samajh nahi aa raha hai

    • @DineshChandra
      @DineshChandra  2 роки тому

      0.48 × 103.12 × 0.0001

    • @digvijaykumar5320
      @digvijaykumar5320 2 роки тому

      @@DineshChandrathank you sir

    • @digvijaykumar5320
      @digvijaykumar5320 2 роки тому

      @@DineshChandra yahi nahin samajh mein a raha tha sir

  • @satyabanmohanty3557
    @satyabanmohanty3557 3 роки тому

    Sir single phase motor ki total winding data kese nikale please jaldi bataie

    • @DineshChandra
      @DineshChandra  3 роки тому

      Playlist me check kr lijiye aapko mil jayegi ua-cam.com/play/PLcFVUpmooFKoebFGD1m--OAaVfEmmZ85a.html

    • @maltiengineering9929
      @maltiengineering9929 2 роки тому

      @@DineshChandra single phase motor ka winding data kaise calculate kare eska video nahi h plz bataye drum se bane stator m data nikalna h

    • @DineshChandra
      @DineshChandra  2 роки тому

      @@maltiengineering9929 ua-cam.com/play/PLcFVUpmooFKoebFGD1m--OAaVfEmmZ85a.html

  • @bhatyawar838
    @bhatyawar838 Рік тому

    000.49 kaise aaya

  • @dangtran6906
    @dangtran6906 2 роки тому +1

    Could u explain formula Z=(3*2*Ts)/z. What does that mean? ( i don't known that number '3' and number '2' mean?). Thank you sir !!

    • @DineshChandra
      @DineshChandra  2 роки тому

      '2' means each turn has 2 number of conductor
      '3' used for 3 phase winding
      Total number of conductors equal to 3×2×N
      Divided by number of slots means per slot conductors

    • @dangtran6906
      @dangtran6906 2 роки тому +1

      @@DineshChandra thank you sir, your video very useful 👍

    • @dangtran6906
      @dangtran6906 2 роки тому

      @@DineshChandra So, if we have 4 pole motor, we will have formula z=(3*4*Ts)/24 right ?

    • @DineshChandra
      @DineshChandra  2 роки тому

      No

    • @DineshChandra
      @DineshChandra  2 роки тому

      This formula give us information related to Conductor per slot

  • @gajendramasurkar5388
    @gajendramasurkar5388 Рік тому

    Sir ji se baat karni hai

  • @rajbahadurvishwakarma9157
    @rajbahadurvishwakarma9157 3 роки тому

    Sir
    Swg kaise nikale ye to bataya hi nahi

    • @DineshChandra
      @DineshChandra  3 роки тому

      ua-cam.com/video/rkmX5YR3fmE/v-deo.html
      Aap playlist check kar lijiye 👍

  • @thuytrangteacher5335
    @thuytrangteacher5335 3 роки тому

    Sorry you can help me by English

  • @thuytrangteacher5335
    @thuytrangteacher5335 3 роки тому +1

    Soory you can turn on VietNamese for me

  • @enamturjo7156
    @enamturjo7156 3 роки тому

    Kw ki fixed 0.95?

    • @DineshChandra
      @DineshChandra  3 роки тому

      As per design considerations
      Because window space factor always less than one

  • @pronobpaul6984
    @pronobpaul6984 3 роки тому +1

    Ar kisika pas armature trans formula ha to mujha batana

    • @DineshChandra
      @DineshChandra  3 роки тому

      Aap playlist check kar lijiye 👍

    • @pronobpaul6984
      @pronobpaul6984 3 роки тому

      Nahi sir upka playlist ma nahi ha

    • @DineshChandra
      @DineshChandra  3 роки тому

      Part 1
      ua-cam.com/video/mWk2uQZB7VQ/v-deo.html

    • @DineshChandra
      @DineshChandra  3 роки тому

      Ye complete playlist hai
      ua-cam.com/play/PLcFVUpmooFKo4TLo8mIl5MWN5Ie6ryJv1.html

  • @payalpaul7663
    @payalpaul7663 3 роки тому

    A formula mil nahi raha

  • @coclover1004
    @coclover1004 2 роки тому

    Yaha 10 ki power 4 ki ha baha caliclate galat kiya h

  • @rohan-fg6fd
    @rohan-fg6fd 2 роки тому

    Samjha nhi aaya

  • @sanjuksanjuk1348
    @sanjuksanjuk1348 3 роки тому +6

    वायर डाटा कैसे निकाले जिस मे वायर ना हो

    • @Dave_en
      @Dave_en 3 роки тому +2

      Kuchh log experience se SWG tay karte hain aur kuchh log slot area se SWG ka calculation karte hain. Wire ki motai design value se thoda kam hi prefer kiya jata hai, taaki coil bilkul fit aaye. 2-3 iteration se exact data banaya jata hai.

    • @Crazyforlove143
      @Crazyforlove143 Рік тому

      @@Dave_en 2 hp single phase 36 slot 4 pole 1440 rpm ac induction motor के लिये standard wire gauge nd turn kaise select करे

    • @Dave_en
      @Dave_en Рік тому +2

      @@Crazyforlove143 Stator ka poora naap lena hoga "mm" me. Stator inner dia, outer dia, slot length. Isse kitna HP ka hai, iska andaja lag jayega. Phir formula me fit kar ke turns nikaalna hai. Bahut kuchh practical values assume karna padega. current 3-8 Amp/sq. mm ke hisaab se SWG calculate karna hoga. Sahuliyat ke liye 6 amp/sq mm maan lete hain. Usse jo swg aayega, turns se multiply kar ke wire cross section area nikaalenge. Ye slot area ka 35% se kam hona chahiye aur 25% se jyada hona chahiye. Jo wire iss criteria ko fulfill karega, wahi wire choose karenge. Jitna ho sake, 35% ke paas iska data match hona chahiye.
      Iss tarah turns aur gauge bilkul sahi aayega. Local companies gauge patla kar dete hain copper cost kam karne ke liye. Hume aisa nhi karna hai.

    • @Crazyforlove143
      @Crazyforlove143 Рік тому

      @@Dave_en sir 1 inch mei 25.4 mm hota h aur stamping size 3 1/2 inch h total 89.9 mm aata h ab aap calculate karke bta do 36 slot h 220 se 240 volt ac ke liye

    • @Dave_en
      @Dave_en Рік тому

      @@Crazyforlove143 Inner diameter aur slot length hi bata do. 3.5 inch diameter hai ya slot ki lambai? Dono feeta ya scale ki madad se naap kar batao.
      Ye bhi yaad rakhna ki cooler ke motor aur paani ke motor ke design me kaafi fark hota hai. Company to company bhi data vary karega.

  • @coclover1004
    @coclover1004 2 роки тому

    Apna calculated galat kiya ha

  • @timucinbahsi445
    @timucinbahsi445 3 роки тому

    baslik ingilizce, thumbnail ingilizce, video baska dilde. altyazi da yok. madem yorum da turkce olsun o zaman.

  • @somanatmali6502
    @somanatmali6502 Рік тому

    Sir aapka contact number chahiye tha