  • @robbiemulholland6477
    @robbiemulholland6477 4 роки тому +53

    What a great video! Huge respect for the guy that built it for seeking advice, and the advice was expert, detailed and very respectful! Well done to both of you 👍

  • @elliottdebell7783
    @elliottdebell7783 4 роки тому +7

    As a brick layer I find I know more about roofs than some roofer from watching your videos! Thank you you have helped me no end

    • @bobbyjuice3935
      @bobbyjuice3935 4 роки тому +1

      My dad was a brick layer, he knew everything in construction and taught me a lot. I have Much respect for you guys!

    • @stefanpuszka8173
      @stefanpuszka8173 3 роки тому +1

      Everybody learns from everybody else especially in the building trade or at least they used to.

  • @finnbrayden8054
    @finnbrayden8054 2 роки тому +5

    As a sparky I found this really insightful. I’ve watched a couple of your videos now.
    I often come up against clients and building inspectors regarding the cut outs for my downlighting and the ways around it to still keep a good barrier.
    I’ve always wondered what the main differences between cold and warm roofs and the benefits.
    Thanks for the videos mate

  • @mrspankyuk
    @mrspankyuk 2 роки тому +2

    Good job Steve. I wish more builders paid attention, like the subject of this video. Carrying on regardless, I think, is more common than it needs to be. It's OK to make a mistake, even the good builders do it... the difference is the good ones put it right!

    • @SteveRoofer
      @SteveRoofer  2 роки тому

      Unfortunately even good builders aren't getting the information they need to make sure that they can do the job correctly I don't blame them for making the mistakes it's just unfortunate that we don't teach people new techniques

    • @ETH92
      @ETH92 8 місяців тому

      @@SteveRoofer It's their responsibility to make sure they learn the correct techniques though. I think their needs to be more regulation of tradesmen to make sure they are suitably qualified.

  • @colinmiles1052
    @colinmiles1052 4 роки тому +3

    Good stuff! I don't think people realise the potential problems with a cold roof - I certainly didn't' until I helped my son with his garden room. He did a lot of research which I( thought was a bit OTT but now realise wasn't. Only problem he has was with using conduit for the wiring - leaves a gap for the warm and moist air to get through. Soon remedied with a squirt of foam!

    • @nofurtherwest3474
      @nofurtherwest3474 10 місяців тому

      What is a cold roof?

    • @colinmiles1052
      @colinmiles1052 10 місяців тому

      A cold roof is where the ceiling is insulated but the roof deck is not. There has to be ventilation in between to remove any condensation. A warm roof is where the roof deck is insulated and the space between ceiling and insulation should be sealed to prevent heat loss.

    • @nofurtherwest3474
      @nofurtherwest3474 10 місяців тому

      @@colinmiles1052 I see thanks. Which is best?

    • @colinmiles1052
      @colinmiles1052 10 місяців тому

      There is no "best".Depends on your roof construction.@@nofurtherwest3474

    • @colinmiles1052
      @colinmiles1052 10 місяців тому

      There is no "best". It all depends what type of roof you are doing.@@nofurtherwest3474

  • @guyanagold4869
    @guyanagold4869 5 років тому +4

    I only ever warm roof it. I use thermal fixings on rubber roofs. But what many manufacturers still spec screws into joist below. Particularly on Grp roofs which i do a lot off. It would be good to see them come up with alternatives for grp/liquids.

    • @SteveRoofer
      @SteveRoofer  5 років тому

      Although GRP is a good material I dont think its good on flat roofs. When you look at why most builders chooses a roof covering its normally based on who is going to do it and how much. I say builders as the majority of GRP roofs laid are laid on small extensions and loft conversions. The bigger the roof the bigger the contractor and the more overseeing of whats used gos on thus GRP is not chosen, there's more control even down to the fixings.
      Builders and small roofers can pick up the GRP products anywhere now at relatively cheap prices thus making it the goto product.

    • @guyanagold4869
      @guyanagold4869 5 років тому

      Steve Roofer i do many small jobs under 35sq. I use liquids & rubber as well depending on the situation but i think grp has the best look & is the most durable. Ive had many rubber roofs to repair from slates blowing onto the roof below. Not really an issue on big high rise flat roofs where your work seems to be in. Im trained on restec 20/20 which is a flexible grp. Its allegedly a hybrid of traditional grp & PU based liquids. I reckon eventually they will all morph into one product. It can overlay more or less any material. Some of the liquids are ridiculously priced in comparison to rubber & grp. I rate them but i think they need to become more competitive

  • @creativetag1
    @creativetag1 3 роки тому +2

    Warm roof definitely the way to go then even insulate underneath as well but make sure insulation it tight to the osb or ply

  • @davecroden9793
    @davecroden9793 4 роки тому +3

    Great video. I’m watching several as I want to build a work shed, but this ‘what NOT to do’ video is so helpful !

  • @jeg569
    @jeg569 4 роки тому +8

    You need a 50mm clear gap between the top of the insulation and the underside of the structural deck, you also need a free flow of air from ventilated soffit to the other soffit.

    • @mofaz3475
      @mofaz3475 3 роки тому

      Why is this gap needed? If the insulation is butt up against the underside of the deck OSB, isn't this effectively closing the air space and therefore making it a warm roof and no venting required?

    • @rmakkinc
      @rmakkinc 3 роки тому +1

      @@mofaz3475 Its only a warm roof when the insulation and vapor control layer are above the wood structure.
      The problem is moisture. Either coming from the internal space, or from the wood itself. Without an air gap and (cross) ventilation, the moisture has no where to go to and will lead to condensation and mold and rot. With a proper warm roof the wood structure is on the internal side, thus having a way to dry out towards to internal space.

    • @ssss-df5qz
      @ssss-df5qz 2 роки тому +1

      @@mofaz3475 Nah because there is still going to be a small cavity to trap moisture. I suppose if you glued it to the board, but even them moisture will move through wood to occupy any little pockets between the board and the insulation.
      Air gap is always the way to go. It takes nothing away from the effectiveness of your insulation, I just can't understand why people don't do it.
      Worst culprit is people who insulate and board their loft space. No gap between the felt and insulation will ensure your rafters rot.
      If air can move, moisture can't condense as quickly as it evaporates in most cases.

  • @PhonexpertsUK
    @PhonexpertsUK 3 роки тому

    Very knowledgeable person
    Love take you advise for my flat roof under construction. Already leaking .

    • @SteveRoofer
      @SteveRoofer  3 роки тому

      Sorry to hear that email me if you need any info steveroofer@gmail.com

  • @BrianSmith-nw2jo
    @BrianSmith-nw2jo 11 місяців тому

    Hi Steve great videos and very useful. I'm not in London but I have an old house that is poorly insulated. I know now (your videos) that I need to seal the insulation in place. And then cover with more insulation but I'm concerned that if I close all the air gaps that the moisture won't get out and then start to cause problems. Just to add to the amount of moisture there is in the building we live in a flood plain. The Victorians dealt with this by having large voids along the roof but this is now costing us.
    Brian

  • @GaryThomsonJoinery
    @GaryThomsonJoinery 4 роки тому +3

    Nice listening to a pro who knows his stuff 👍

  • @Bob-kb5pv
    @Bob-kb5pv 13 годин тому

    We have a warm roof on our extension. It is 10x4 meters with two 3x2 roof lanterns. We are thinking of taking out one of the lanterns and constructing a warm roof in the well that the lantern is positioned on. The reason for doing it this way is so that we don't disturb the existing roof covering. What do you think?

  • @kranson8514
    @kranson8514 4 роки тому +3

    Such simple understanding of air flow and humidity can make such a huge difference. To not have used C24 or even C16 timbers from the get go was a surprise, but as you said salvageable and it was a neat job if not very well planned. Good video.👍

    • @danielb8288
      @danielb8288 4 роки тому +2

      C16 and C24 are timber grades... not timber treatments... I’m sure his only criticism was that the timbers were untreated (not ungraded)

    • @kranson8514
      @kranson8514 4 роки тому

      @@danielb8288 yes absolutely i took for granted those who use those timbers for construction automatically purchase the treated option 👍 p.s HNY

  • @Pete40-b1u
    @Pete40-b1u 5 років тому +1

    Great detail as ever. Thanks for taking the time to explain the problems and possible solutions. Keep up the good work. All the best Pete

    • @SteveRoofer
      @SteveRoofer  5 років тому

      Thanks whats your interest in roofing?

    • @Pete40-b1u
      @Pete40-b1u 5 років тому +1

      Steve Roofer Hi Steve my interest in roofing is that I have a built up felt flat roof kitchen extension that’s probably 15 + years old. It hasn’t shown any signs of leaking but no doubt will soon and if possible would like to re roof it myself. I suspect there is little insulation and would like to do the job correctly. I’ve heard and seen too many jobs where insulation is used incorrectly and where ventilation if any isn’t effective. Your videos and comments are a valuable source of accurate information. I wish you had a book available to purchase. Thanks again for taking the time to produce your valuable vids. Cheers Pete. ( north west. England )

  • @Dave5843-d9m
    @Dave5843-d9m 4 роки тому +4

    Spray foam under the roof with vapour barrier would have solved the problem. But it’s a closed cell foam so no vapour transfer.
    Ventilation is ok but the area between roof lantern and house wall is always difficult. Vents are ok but they pass through the membrane risking leaks. Also risk damage from maintenance work on the house.

  • @holdfast7657
    @holdfast7657 4 роки тому +1

    He would have been getting a lot of moisture from the cavity. Usually during the build process the cavities get wet from the water in the materials and also rain. Nothing wrong with a cold roof as long as there's plenty of ventilation. As you say cross batten would have been the best way, but many people like to save on materials. As for the downlights, the cutting in through the insulation happens a lot. The problem here is allowing the heat from the room to condense on the cold roof.

  • @russellfreestone8580
    @russellfreestone8580 3 роки тому

    Really excellent review of the job, a lot of really useful information. Good job. Thanks give me a lot to think about

  • @FraMovie
    @FraMovie 4 роки тому

    Very nice description of the problems and possible solutions.

  • @Muscleduck
    @Muscleduck 3 роки тому

    Obviously a man who knows his way around tools and takes pride in his work. Such a shame that he didn't do a warm roof, which would probably be my recommendation. Take everything out at the bottom, isulate on top, add a new top layer to convert it into a warm roof. I'd also recommend not finishing the ceiling on the inside for probably 6 months, to make sure everything has enough time to dry out.

  • @911alps
    @911alps 4 роки тому +3

    Can you please do a video for a novice diy to insulate an internal garage roof please

  • @xt60033
    @xt60033 2 роки тому +4

    Another great video Steve! I'm building a flat roof extension to an old property in which I have very limited headroom, limited to where the new roof tucks under/into the existing roof, therefore the flat roof build up has to be minimal, while maintaining best possible u-value. At 3m span I'm using 145 x 47 timbers, 400 centers. My planned build up is: 12mm plasterboard- 145mm timbers containing 100mm mineral wool- multifoil sf19 insulation over rafters pinned down by 38mm battens. 18mm osb3- epdm membrane. The sf19 acts as a vapour barrier, no ventilation. This gives a total build up of 220mm, leaving just 2090-2040mm headroom in the bedroom below. Does this sound feasible to you, or do you have any suggestions on how it can be improved?
    Thanks, Colin...

    • @SteveRoofer
      @SteveRoofer  2 роки тому

      Yes drop me an email and ill send you some info

  • @JohnSmith-rp7bc
    @JohnSmith-rp7bc 8 місяців тому

    your videos although a few years old, are proving really useful to me. However, can I ask, if I fit a vapour barrier over insulation like can be seen in this video, would the screws of the plasterboard fitted afterwards compromise the VP ?

  • @chriswise7013
    @chriswise7013 4 роки тому

    Bit of advice if anyone can help...
    So far I've built my home garden office as follows...concrete base, 12mm ply floor sat on top of 25mm blue roof battens giving some air flow beneath the office. On top of this I've built 4x2 pressure treated framework walls with 12mm ply walls on the outside of the framework - that has all been wrapped in breathable roof membrane. On top of the 12mm ply floor I've laid more 4x2 pressure treated lumber, belly side down and on top of this I've laid 18mm ply. In the 2" gap between the belly down 4x2's in the floor I've laid 100mm compressed loft insulation to help with sound-deadening and also to hopefully help with insulation (although I know 100mm loft roll compressed into a 50mm gap isn't ideal).
    On the outside of the 12mm ply walls I've stapled breathable membrane and on top of this I've fastened more 25mm x 50mm blue roof battens (giving a 25mm air gap) and on the outside of these battens I've fastened the finished pressure treated tongue & groove cladding. On the inside of the walls between the 4x2 framework I'm putting 100mm loft roll insulation. What I'm unsure of is whether I need to staple a waterproof membrane over this before I put plasterboard on the inside?
    Now on to the roof, which I've not started yet but I have purchased all of the materials already. The idea is as follows...6x2 rafters sat on the walls but cut in by 2 inches, 12mm ply, breathable roofing membrane, 25mm x 50mm blue roofing battens, 18mm ply, finished off by a one-piece EPDM rubber roof. On the inside will be the same as the walls i.e. 100mm loft roll insulation between the rafters, possibly a non-breathable plastic membrane (?) and then plasterboard for the ceiling.
    I'm worried that in building it as planned above, I may cause condensation to form!? The office will be heated by an electric Dimplex wall mounted heating panel and there will be 4 x spotlights in the ceiling. I haven't planned for any ventilation as I just don't know where they would need to be located i.e. within the roof structure itself (if so, between which layers and in every joist gap?) or in the actual 'room' itself? Should I drill a few 2 inch holes in each roof joist so that air can theoretically flow between each of the joist gaps?
    I'm hoping that in leaving a 25mm air gap around the whole structure (between the 18mm ply roof 12mm ply 'under-roof' and also between the 12mm walls and T&G finished cladding) it will help to keep moisture from entering the inner building but I don't understand insulation enough to know what I need to do in order to stop moisture forming from within the building.
    Sorry to waffle but I hope I've explained everything well enough that the above makes sense to you. If you would be able to give some advice on what I should do, bearing in mind that I've already purchased everything except the non-breathable membrane nor the plasterboard.

  • @IanDavies
    @IanDavies 3 роки тому

    Love your videos, really informative. Fantastic 👍🏼
    Would love to see a video on how to correctly install spotlights into a cold roof, I just can't find a good source of information on this!
    Keep up the brilliant videos 👏🏼

  • @weswhit8745
    @weswhit8745 2 роки тому

    Great video and great explanations, currently doing similar and watching that my builder is venting properly. My only concern with mine is we are having spotlights and see plenty done like this is there are correct way to fit spotlights without them causing problems

    • @SteveRoofer
      @SteveRoofer  2 роки тому

      Have you seen my video on Spotlight that should answer your question ua-cam.com/video/L-hXgV44omc/v-deo.html&ab_channel=SteveRoofer

  • @thefreedomguyuk
    @thefreedomguyuk 3 роки тому +1

    Great video !
    -64 dislikes....Must be from builders who have been rumbled by this video.

  • @jamesdiver2183
    @jamesdiver2183 5 місяців тому

    i have just recently done a cold roof, pitched, vaulted ceiling. the architect specified 170 x45 c16 with 150 Kspan pushed up tight to the underside of sarking with a 3mm gap between boards now 10mm after the sun bashed it for a while, got a breathable membrane and 12mm counter baton and 25mm baton then concrete tile. on underside of rafter he did ask for kingspan kooltherm 118 however client thought this was too expensive and opted for 25mm recticel then a vapour barrier then 12 .5 plasterboard. Have i got something to be worried about in the future???

  • @dahagel4561
    @dahagel4561 3 роки тому

    The big problem is the plywood sheet funktioning as an moist barrier .... I would strongly recommend a ventilation area on top of the rafters instead of inside.... Then a vapor permeable membrane on top of the insulation and minimum 5cm of ventilation area .... On top of that the plywood ....

  • @earlmcgill5867
    @earlmcgill5867 2 роки тому

    Great video! With a vapor barrier applied on the underside of the joists, won't it just be punched full of holes with the drywall screws?

    • @SteveRoofer
      @SteveRoofer  2 роки тому +1

      Yes it would that's why you should use a special tape that stops that from happening it stops the movement of air through those little holes however the little holes don't let through that much air generally the problem is that they don't fit the vapour barrier correctly and leave huge holes like cutting light fitting through

  • @Craigo5000
    @Craigo5000 4 роки тому +5

    Hi Steve great video but you never give an example on how to actually install the downlighters without cutting the insulation or the vapour barrier. I can't find anything on the internet suggesting how to do it either?

    • @Craigo5000
      @Craigo5000 4 роки тому +4

      I worked it out myself. Ended up finding a product called Thermahood and bought 20 of them. I'll make an retro fit install video if people want it

    • @robnelsonphotofilm
      @robnelsonphotofilm 4 роки тому

      @@Craigo5000 Hey, did you manage to create the video for this? Just having the same issue at the moment.

    • @Craigo5000
      @Craigo5000 4 роки тому +1

      @@robnelsonphotofilm sorry not yet with Xmas and all. I'll do something next week and post my results. I'm actually really please with the recent snow and ice - my roof was the only roof on the road with snow still on it 2 days after it had fell. The guy over the road who had 48k worth of loft conversion done had no snow on his roof. I'm so glad I ripped all mine out and did it properly. It's clearly paying off as we speak. The key is the make it 100% airtight with maximum cross flow on the cold side. I also retrofitted a product called Thermahood for all my lighting. Along with a vapour barrer, insulation bonding over the Thermahoods too, you simply get zero air exchange from the hot/cold sides.
      I'll post the link to the video once done. 👍

    • @robnelsonphotofilm
      @robnelsonphotofilm 4 роки тому

      @@Craigo5000 thanks for this, I have seen these but not sure how to fit them in the Celotex board as I can’t access above the insulation board.

    • @Craigo5000
      @Craigo5000 4 роки тому +1

      @@robnelsonphotofilm that could be tricky but not impossible. You may have to do away with insulation over them. If you haven't yet plasterboarded, it would be easier to cut out a section to accommodate the Thermahood and then seal that section back in place. I'll get my video done next week 👍

  • @clivewilliams1406
    @clivewilliams1406 3 роки тому

    You have restored some faith to me back into 'youtube' tradesmen by giving a sound and knowledgeable assessment of the issues. Well done!
    However, there is one issue that is absolutely dire - The adjoining tiled roof lands directly down onto the flat roof with the sarking felt UNDER the flat roof construction!! Any water driven under the tiles for what ever reason will land on the underside of the flat roof construction, go undetected for some time and rot the construction. Also, how far does the flat roof waterproofing extend up the sloping roof - I always specify 150mm vertically and under the sarking? The tiled roof should have a tilting fillet for the full length to create an upstand to dress the flat roof and sloping roof over. This also prevents wind driven rain from the flat roof finding its way into the main roof as well as preventing the natural fretting of the tiles that are shown bearing down on the flat roof waterproofing. Movement due to differential thermal expansion and contraction is the problem, which although only a mm or two will allow the sharp edge of the tile cutting into the waterproofing.

    • @SteveRoofer
      @SteveRoofer  3 роки тому

      Yes, you are correct; there are problems with the front slope. The way this job went was for me to report the problems out to the customer, he told the builder who redid the roof last year and this year the customer called me again and told me that it's exactly the same I asked if he re did the roof to the correct specifications and the customer doesn't know as didn't look! The saga goes on.

    • @clivewilliams1406
      @clivewilliams1406 3 роки тому

      @@SteveRoofer Its a real shame that in my experience the majority of jobbing builders do not or can't do a professional job and when pointed out to the client they are unwilling to demand that the correct job be done and if necessary back that up with litigation. It really is disheartening to find that clients always seem to be too frightened to confront the issues. I doubt whether they would accept this status quo from any other supplier - its like buying a car with defective brakes or electrical apparatus that could cause a fire????

  • @joansparky4439
    @joansparky4439 3 роки тому +1

    The vapor barrier needs to sit on the side of the insulation that faces the warm/humid air.
    So it depends on your local climate and is not as universal.

    • @SteveRoofer
      @SteveRoofer  3 роки тому +1

      Yes correct in warm countries you place the VCL on the outside

  • @Dg-zj6jo
    @Dg-zj6jo 4 роки тому

    brilliant steve iv got a massive vent for my rubber roof will cut it in soon iv got joists so hopefully it can breath when i vent the top it should help with the sweating in hot weather

  • @Elfin4
    @Elfin4 3 роки тому

    6:18 Joist doubled up but no signs of squares washers and I bet not one tooted timber connector between the joists.

  • @warrenduffy1377
    @warrenduffy1377 2 роки тому

    Does the closed cell insulation with foil backing, along with foaming air gap details not suffice as a vapour barrier?
    Foil has a superior vapour Impermeability than poly even.

    • @SteveRoofer
      @SteveRoofer  2 роки тому

      Yes one of the problmes on this could be that they have introduced a AVCL (air vapour control layer) in the wrong place

    • @warrenduffy1377
      @warrenduffy1377 2 роки тому

      Cheers 👍

  • @Pliuh2007
    @Pliuh2007 6 місяців тому

    hi , thanks for video ! planning my new roof , same cold roof , joists hanging on the wall with hangers , got the walls from sides .. need ventilation! how is better to do .. go battens along the joists then across the joists ? need 2 layers of battens or one ?! thank you

  • @Benzknees
    @Benzknees 4 роки тому

    The pitched roof underfelt looks like it’s not been cut & lapped over the flat roof upturn. I imagine that’s allowing water run off under the flat roof and into the decking & void.

  • @ranbirsingh7666
    @ranbirsingh7666 3 роки тому

    Would building control not have picked the issues up, and following building regulations drawing for roof details ? Thanks

  • @Billy_Bull_Sheeter
    @Billy_Bull_Sheeter 4 роки тому +1

    I've had the same rubber roof put on an outdoor single brick shed. And was getting moisture. I thought it was the roof leaking. I used a dehumidifier to get rid of any moisture. Once I baton it and use insulation board I'm hoping it will be OK. I have a window in it, which allows air to circulate.
    Should it be OK. ?

  • @guybrooks-edwards863
    @guybrooks-edwards863 4 роки тому +3

    Hi Steve,
    Great videos any advice for a cold roof with Easijoists and also how to fit spotlights without cutting into insulation?
    Thanks
    Guy

  • @sk2283
    @sk2283 4 роки тому +1

    Why didn't he go for a warm roof ? was height an issue ? I deal with a lot of condensation & mould and people not fitting vapour barriers and / or proper venting is 95% of the problem !

  • @dakdylan
    @dakdylan 3 роки тому

    Don’t we want to cut holes in joists in the center third for ventilation? This is done for electric running wires as to not compromise the joist critically and would assume you would want to do it here also.

  • @matthiasdemey1423
    @matthiasdemey1423 4 роки тому +1

    Hello, can you elaborate why one would need to use treated wood for a (flat, cold?) roof construction? Thank you!

    • @xxxsmithxxxx
      @xxxsmithxxxx 4 роки тому +1

      I would assume it’s because any condensation build up on untreated timber is more likely to lead to rot and decay.

    • @matthiasdemey1423
      @matthiasdemey1423 4 роки тому +1

      @@xxxsmithxxxx If properly vented (assuming this is always the case and standard practice), there will be no condensation.

    • @xxxsmithxxxx
      @xxxsmithxxxx 4 роки тому +1

      @@matthiasdemey1423 belt and braces approach maybe in the event of unventilated corners etc. Again, I can only assume.

  • @peteramberley9952
    @peteramberley9952 5 років тому

    Hi steve with regards to the light coloured timber they do a golden wood preserver not allways green or blue like battens

    • @SteveRoofer
      @SteveRoofer  5 років тому +1

      I talked to the owner and its not treated

  • @josephcroft4268
    @josephcroft4268 3 роки тому

    i have a 10 x 10 foot shed gym with 14 , 9" x 3" air bricks installed and the ply roof started going black i had to paint the ceiling with anti mould paint

  • @MrWeddingPhotography
    @MrWeddingPhotography 4 роки тому +2

    Can I ask, if the down lights are a problem in this situation, whats the solution if you want down lights in this situation?

    • @cecilbrisley5185
      @cecilbrisley5185 4 роки тому

      Change your mind about the lights. Keep it simple. Problem solved.

  • @82dickiebo
    @82dickiebo 3 роки тому

    Hi Steve, that's a really informative video. Thanks! Could I just ask...do I need a vapour barrier on my internal walls and ceiling in my garden room that I am building. There will be no heating in it but is going to be insulated with 50mm Rockwool in the walls and 100mm Rockwool in the ceiling leaving a 50mm gap in the ceiling for airflow to the soffit vents I have in the front and back. (It's a flat cold roof by the way.) The reason I ask is that I have read that a vapour barrier will not allow the colder temperatures at night to get rid of any moisture. It apparently traps it essentially in an unheated build. I'm not sure if this is accurate and wondering if you could shed any light on it for me? Many Thanks

  • @jeremysmith7691
    @jeremysmith7691 3 роки тому

    very informative , the tiled eave course is giving me nightmares, look at the state of it

  • @1spiders1
    @1spiders1 Рік тому

    Which vapour barrier do you recommend,? And would this be simply stapled to the under side if the joists?

    • @SteveRoofer
      @SteveRoofer  Рік тому

      Novia 1200 Vapour Control Layer 100m2 Roll follow the instructions and use alll the tapes

  • @gareththomas9178
    @gareththomas9178 11 місяців тому

    Hi steve, i have a question, i have a small extension with a warm roof and a overhang on the front there is a secret gutter, the inside is not plasterboard yet, and we had a lot of rain when roof was done, my problem is where the overhang is the osb below the secret gutter is sweating. I was told to pack this with insulation to avoid drafts, at the moment there is no insulation in there and with the cold frost in the morning i am guessing that is causing the sweating. Do i fill this with rockwool or pir, i plan on having downlights in the sofit.

    • @SteveRoofer
      @SteveRoofer  11 місяців тому

      you really need to send me some photographs so that I can understand this

    • @gareththomas9178
      @gareththomas9178 11 місяців тому

      Hi Steve, basically, the overhang on roof is about 600 wide, and I haven't put any vents in the sofit. On the overhang, there is a secret gutter built into the overhang, and from the inside, I can see into the sofit and see sweating on the osb on the overhang. I was told I would have to insulate the gap on the inside to stop drafts coming in, and I think the warm air from the house Is going into the sofit and meeting the cold on the overhang, there is no insulation on the overhang as there is a gutter built into it. The rest of the roof is a warm roof.

  • @Rdbroofer
    @Rdbroofer 3 роки тому +1

    Been flat roofing for 35 years, Put a warm roof on if you can, saves the need for vents.

    • @SteveRoofer
      @SteveRoofer  3 роки тому +1

      Yes much easier construction

    • @clivewilliams1406
      @clivewilliams1406 3 роки тому +3

      The trouble is that the overall construction depth of a warm roof can cause detail and aesthetic issues. Besides how many jobbing builders know what a warm roof is - they probably think that it involves some sort of heater!

  • @xmagicmike97x
    @xmagicmike97x Місяць тому

    you should cut a 100mm square in the insulation for the downlights or they'll overheat and fail very quickly or become a fire risk.

  • @dantaylor8679
    @dantaylor8679 3 роки тому

    Hi Steve. I have a flat roof garden room with joist running front to back. The left hand side of the roof has been cantilevered off the front to back joists. How would i overcome the cross ventilation for the cantilevered section?

  • @Topchip23
    @Topchip23 4 роки тому +5

    Common problem with cold roof , sometimes I’ve seen celotex or whatever stored outside and left out in pissing rain then fitted soaking wet which will dry out over time but not before you notice this exact problem

  • @Jaz270993
    @Jaz270993 3 роки тому

    Presuming when asking about if the timber is treated we are referring to rots, how would you tell if a timber has been treated? Would it be a darker colour?

    • @andtastic1
      @andtastic1 3 роки тому

      JPT. yes, pressure treated timber has a green tint.

  • @andrewmilne1738
    @andrewmilne1738 3 роки тому

    Hi mate i have a single brick garage in highlands. I will be installing a insulted roof.will this be enough to keep it warm to do a work out in if I use a heater to heat it before my workout it will just be the roof that is insulted

  • @Dc-hq6vp
    @Dc-hq6vp 4 роки тому

    Warm roofs are a better solution, but think that if you do have a well insulated cold roof and a vapour check in place that venting the roof above does in itself produce problems and breaches the text book achievable u values.

  • @attilatoth8261
    @attilatoth8261 3 роки тому +1

    Hi Steve. I'm planning to convert my small shed into a sauna. How could I stop the condensation to damage my roof? What would be the best insulation for the sauna roof?

  • @taramiller70
    @taramiller70 3 роки тому

    Do dehumifers and air purfier both kill mold spores and mold I have mold in my bedroom and I use dehumifers and I have plug in air purfier also do they both work and are they both worth using

  • @remcohuijdts535
    @remcohuijdts535 4 роки тому +1

    Hi, great video, I hope you have some advice for my unusual project. I am building a 4x4 metre drum studio. It is constructed with a flat cold roof and uses a room in room principle. Because of sound insulation venting is not really an option. So my constructions is as follows: outer room: on top EDPM, OSB, rockwook, damp proof membrane, 10 cm of air and then the inner room rockwool, damp proof membrane, plasterboard. There will be mechanical ventilation in the inner room. I was not planning venting the space between the rooms Should I do this as well? are problems to be expected considering the 2 membrames? also it wont be heated 24/7 and there wont be holes in the plasterboard for lights etc

  • @stevensmith8998
    @stevensmith8998 3 роки тому

    If you put a continuous vapour barrier on the inside of the insulation I don’t understand how you put the lighting in with cutting holes in it?

    • @SteveRoofer
      @SteveRoofer  3 роки тому

      thats the problem you cant put the light in without having problems with the AVCL (air vapour control layer) and the insulation

  • @123prestolee
    @123prestolee 3 роки тому

    Hi Steve, we are refurbishing a cellar room that has a reenforced concrete roof, which sits approx 400mm above the ground. The 2 sides of the roof that can be ventilated, are at 90 degrees to each other, so we can’t cross-vent. Also, there isn’t enough space to insulate above (access to property). Possible a ridiculous idea, but could we fix PIR to underside, then use something like passive house variable membrane to make it airtight?

  • @Home_made_ch
    @Home_made_ch 2 роки тому

    Could you advise how to remove condensation from bottom of onduline roofing fitted on my shed. No insulation on walls so far. Just timber walls with shiplap cladding and timber rafters with onduline on top of them. Roof angle about 10 degree.

    • @SteveRoofer
      @SteveRoofer  2 роки тому

      You have to finish the inside and make it airtight and then insulate and vent the roof like a cold roof. Nearly every cold roof out ther eat the moment has condensation its because of the weather it will go away soon so if its not that bad you are doing well

  • @davechamberlain9684
    @davechamberlain9684 3 роки тому

    timbers have got C24 stamped on it ?

  • @mgzt1
    @mgzt1 Рік тому

    Hi I’m starting a model railway in the garage. Please can you advise on insulation and condensation? Thanks

  • @davidmoseley2277
    @davidmoseley2277 4 роки тому

    Hi, Great video and commentary. Question : at 3.40 you say to make circular holes in the firring. Doesnt the firring (and joists) stop just over the wallplate so ventilation would go around the ends?

    • @SteveRoofer
      @SteveRoofer  4 роки тому

      Possibly but you need to get a good flow and a cross flow

  • @funkdrummer
    @funkdrummer 4 роки тому

    Would I need to vent the space between the wall and metal siding on a 64 sq. ft. ? I'm converting a wood framed, corrugated metal siding/roof shed to a drum room. I plan to put foam board in the wall cavity like in the photos you are reviewing. I'm concerned once I put the foam board insulation in, seal it with expanding foam, and cover the interior with plywood panels that there will be condensation in the walls on the inside of the metal siding.

    • @SteveRoofer
      @SteveRoofer  4 роки тому

      You need to send e details and I will have a look

    • @funkdrummer
      @funkdrummer 4 роки тому

      @@SteveRoofer what is the best way to get you details/photos?

  • @tomorichard
    @tomorichard 3 роки тому

    As an electrician. Can down light not be fitted into a flat roof due to the insulation removal??

    • @paulped1
      @paulped1 3 роки тому

      Cut a square section out foe the light a, then use a thinner layer of insulation to underside of roof between down light mate.

  • @b21playa
    @b21playa 3 роки тому

    You say the lights shouldn’t of been cut into insulation, how else could they be fitted? I’m looking to do something similar and want to ensure it’s done right, the soffits would be vented

    • @SteveRoofer
      @SteveRoofer  3 роки тому

      cut the lights in but don't undermine the thermal performance of the insulation also make sure the AVCL is intact after you have fitted the lights All extremely hard to do

    • @b21playa
      @b21playa 3 роки тому

      @@SteveRoofer thanks. Maybe I’ll look into a warm roof instead. Do I still need vapour barrier and venting?

    • @SteveRoofer
      @SteveRoofer  3 роки тому +1

      you don't vent warm roofs yes you have to have a VCL

    • @b21playa
      @b21playa 3 роки тому

      @@SteveRoofer perfect 👍

  • @nicks4934
    @nicks4934 2 роки тому

    This is the perfect mancave video. A video on how to build a mancave. 😀 for cavemen by cavemen. Nice video!

  • @familiamotarica6616
    @familiamotarica6616 3 роки тому

    hello steve thank you for the video. what is good to treat the wood with when building a roof?

  • @GJMBuildingJoinerycarpentry
    @GJMBuildingJoinerycarpentry 4 роки тому +1

    there is no reason at all for it to be treated timber if it's getting covered and if you cross buttoned it from the top what would the firms sit on to

    • @tristanpatterson3843
      @tristanpatterson3843 4 роки тому

      Exactly, unless you're expecting it to leak, and you're never going to fix it? All my new construction these days has roof and exterior walls specified as treated, pain in the arse.

  • @izzzzzz6
    @izzzzzz6 4 роки тому

    I have a roof with an 11 degree pitch, i was thinking to try to insulate between the rafters with 40mm hard foam leaving an air gap all the way to the ridge with a slightly larger air gap at the ridge itself. Currently the loft is a crawl space around 4ft high at the ridge, after insulating i was going to also add plasterboard with yet another air gap of 2cm. It is a tin roof with no insulation, between the tin and the rafters are simple wooden planks which do not fit tightly, basically you can see the tin between the planks. The idea is to open up the loft space a bit to the house for extra storage and space and to try to stop ice dams from forming on the eves. The eves are very large and overhang close to 2.5M. the warm roof melts the snow and meets the cold eves where it freezes and destroys the nails that hold the tin to the rafters.
    Hoping to kill several birds with one stone but keen to avoid ridge rot. I'm wondering if the external tin would need to be lifted at the ridge providing yet another breathing point closer to the ridge. Not sure what to do about moisture barriers. I was thinking to put some plastic somewhere in the sandwich but wondering if it's just better to omit it and leave everything porous bar the insulation itself.

  • @vayinokki2502
    @vayinokki2502 3 роки тому

    Should I put vapour barrier and then insulation on roof or vice versa? Please advise. Thanks.

  • @adamkingdon8063
    @adamkingdon8063 5 років тому

    I have two properties with roofing problems, London, Hampstead NW3 and Kensington, one has a flat roof, the other I think is a cold roof with epdm rubber, the roof with the flat roof has water damage, it is ventilated well I believe, i think it’s asphalt, it may need the insulation redone? Some brickwork may need repointing, many problems, we have a sun roof built in also its timber, we are thinking about roof tiles but are not sure about the building and construction problems associated with it, I am in Chelsea and Fulham all next week if you are passing by would you care to come and have a look at some other roof engineering problems that may have water damage also on a small industrial estate, I understand you may charge for a professional survey, thanks.

  • @alexpowells
    @alexpowells 3 роки тому

    Timber in this video is treated and tryed can see on stamp on wood as you talk about it

  • @stevensmith8998
    @stevensmith8998 3 роки тому

    Does all this apply if you were to make a loft space in your garage, and insulate and board it out between that and the converted garage below ? Can it still sweat or does the air circulation coming in from the sofits prevent that?

  • @teach1913
    @teach1913 4 роки тому +2

    @Steve Roofer thanks for taking the time to make the vid, very informative! I am starting the exact same project and have 2 q's: Why is treated/tanalised timber recommended for the whole roof as it will all be under cover once the roof covering is on? Also how do you get around the issue of the downlights going through the insulation, I thought there is no getting around that? Cheers

    • @SteveRoofer
      @SteveRoofer  4 роки тому

      All structural work has to be treated/tanalised timbers.If at a later day one rotted and the roof collapsed they could be big problems so all structural timbers are treated. As regards spotlights in the ceiling as long as you don't break the thermal element of the roof and the vapour control layer you can do whatever you want

  • @londonengland7096
    @londonengland7096 2 роки тому

    Hello Steve I need a small extension roof done in London can you come down and price up please?

  • @craigjones7773
    @craigjones7773 Рік тому

    Can I do cross battens for side(s) ventilation aswell as front ventilation without venting the rear?

  • @starky497
    @starky497 4 роки тому

    Superbly instructive thanks

  • @reecekennedy8528
    @reecekennedy8528 3 роки тому

    Hi Steve! Great work on the video!
    Out of interest, do you know what lintel was used over those bifold doors / width of opening?

  • @daveandrews4113
    @daveandrews4113 4 роки тому +3

    Great videos Steve, and ones that I’m really glad I stumbled upon. Would you mind offering some advice ? I am building a simple 3.6m square workshop and as well as getting it watertight, I’d like it as soundproof as possible. My question is this: Can I use the warm roof system and then insulate and board on the inside for soundproofing ? Would this cause any issues with sweating / condensation? Thanks in advance. Kind regards, Dave.

    • @SteveRoofer
      @SteveRoofer  4 роки тому +4

      Good question. Use rockwood inside as its vapor open. Try to make sure the insulation on the roof better than whats between the joists.

  • @donready119
    @donready119 4 роки тому

    Lots of fine advice here. I would disagree that pressure treated wood is required, perhaps your code requires it but that is another matter. OSB is junk; it is a mold factory. Plywood costs more but it is tough as hell and more resistant to mold. Ventilation is everything and I heartily endorse the strapping. In Canada, vapour barrier use has changed a bit. At one point we were required to wrap the window and door openings with plastic. That stopped when the wood rotted. Vapour barrier use is now being questioned. Fine Homebuilding has a great Green Build offshoot where the science is debated.

    • @ricos1497
      @ricos1497 4 роки тому

      Do you have a link for that offshoot channel? Thanks.

    • @mickeyjoe848
      @mickeyjoe848 3 роки тому

      Osb is far better than plywood. Any moisture at all and plywood comes apart

  • @robertmij7425
    @robertmij7425 4 роки тому

    I have a question to ask. My friend who’s a builder told be to over board my plaster in my attic bedroom with Kingspan. It’s an old house build in the late 1800s. I noticed the other night I had condensation all up to my apex from my eaves so I have taken the insulation off the plaster board and then noticed moisture on the plaster too. Is there any way of retro fitting the insulation to this house. Or will I need to reroof to get a vapour barrier installed thanks.

  • @stillloading2702
    @stillloading2702 3 роки тому +1

    wrong Cross batten won’t help with venting towards any skylight as the air flow gets restricted the proper way is to create a vented upstand around the sky light and allow the ventilation to blow straight through.

  • @bruceboucher2134
    @bruceboucher2134 3 роки тому

    Good Video great advice

  • @jackmcbeath4305
    @jackmcbeath4305 4 роки тому +1

    So essentially with a cold roof you always vent the roof space and install a vapour barrier ?

    • @hazmat5749
      @hazmat5749 4 роки тому +1

      If its well ventilated a vapour barrier is not needed. Ventilation is always the best option.

  • @eharts808
    @eharts808 9 місяців тому

    Amazing vid..thx Steve

  • @generalg7092
    @generalg7092 3 роки тому

    Hi Steve. I've watched a few or your videos now, and based on your brilliant knowledge of roofing, you seem like the right man to ask.
    I have a 20x10ft timber purpose built shed/garden room. It is a pitched roof design with eaves overhanging the side walls. On the outside, the eaves board have a 1inch gap running the whole length of the side walls.
    1: is this designed this way to stay open for a reason? Can I close it off and seal it up? As it gets very cold when trying to work inside (I have already added 2 vent holes on both the gable ends, and have an extractor fan installed in the center of the building throwing out the moist air)
    2: im looking to insulate the whole shed soon, when I do, can I place the insulation boards directly up against the wall and ceiling cladding, or do I have to leave an air gap?
    3: If I were to seal the whole room with insulation ect (other than my venting holes) will i encounter any condensation/mold issues?
    I appreciate this is a lot to ask, but I just need some advice from someone who knows what they are talking about before I go and spend a load of money on materials.
    I look forward to hearing from you.
    Many thanks in advance

    • @SteveRoofer
      @SteveRoofer  3 роки тому

      to much info please send loads of photos info@londonflatroofing.co.uk

    • @generalg7092
      @generalg7092 3 роки тому

      @@SteveRoofer cheers Steve. I have sent you some pictures to have a look at 👍

  • @sclarke978
    @sclarke978 4 роки тому

    Steve, I need your help, I've got a flat garage concrete roof connected to the house and it's a nightmare. I've stripped the toilet back which is under it and need advice before going further.

  • @adamkingdon8063
    @adamkingdon8063 4 роки тому

    Can’t we have building inspectors sign off roof construction projects that otherwise lead to building damage by water ingress and damp problems?

  • @selfbuilder8647
    @selfbuilder8647 4 роки тому

    Excellent video! What type of glue would you recommend for gluing the OSB to the joists?

  • @firebladecymru
    @firebladecymru 4 роки тому

    So what are Building Control doing?

  • @richardgshields
    @richardgshields 4 роки тому

    You gotta have ridge vents on ANY construction. A typical household vents 50 to 60 gallons of water as vapor - PER DAY! People have no freaking clue.

  • @D4ENX
    @D4ENX 5 років тому +1

    Thanks for that Steve, I need to build a small porch roof with a roof lantern on it, there’s’ so a wall plate all round on 3 sides of it, I could really do with some advice before I start the build, is there a way of emailing you so I could send you some pictures? Thankyou.

    • @SteveRoofer
      @SteveRoofer  5 років тому +1

      No problems my email address is info@londonflatroofing.co.uk

  • @Username89039
    @Username89039 4 роки тому

    What is that "not GRP" product? Any good?

  • @user-qp6vg9ho8u
    @user-qp6vg9ho8u 4 роки тому

    Just wondering what would happen if you put a vapour barrier on the inside and outside of the insulation? Is this ok or does it cause problems

    • @SteveRoofer
      @SteveRoofer  4 роки тому

      If you put a vapour control under the installation and let's say this vapour control is extremely good over a period of time some moisture will definitely get into the installation. This moisture has to get out so from my understanding above the Insolation everything should be less vapour resistant. So the most vapour resistant products in the buildup should be the vapour control layer. However, this isn't necessarily always true because no one looks at how vapour resistant the flat roof waterproof membrane is I've discussed this with many people and It's generally accepted that above the vapour control layer everything should be equal to the resistance of moisture or less. So to answer your question the same vapour barrier above and the same vapour barrier below would be equal and should theoretically work. This is also spoken about in a document published byTRADA (The Timber Research and Development Association) They also discuss that no wood products should be used in the buildup of a warm roof above the vapour barrier!

    • @user-qp6vg9ho8u
      @user-qp6vg9ho8u 4 роки тому

      Steve Roofer thank you for your detailed response. This has really helped clarify this issue which I have been thinking about for a while now

    • @SteveRoofer
      @SteveRoofer  4 роки тому +1

      Me too, all of this is an evolving situation and very hit and miss with no backup and little understanding. I have to give ten-year guarantees that all of this works. Interestingly old felt roofs were made so that they could be replaced when they failed. All new warm roofs cannot be replaced when they fail, when they fail they leak when they leak water gets to the insulation, wet insulation won't work and will need replacing as you cant dry it out. Conclusion build warm roofs to last a minimum of 20 to 30 years or build them so that the waterproofing is changeable without changing the insulation. So how do we do this! I'm working on this now but the truth of the matter is people just won't do it as they want cheap solutions and a long-term roof solution is costly.

    • @user-qp6vg9ho8u
      @user-qp6vg9ho8u 4 роки тому

      Steve Roofer luckily I don’t have all the complication that you guys do in the trade as I’m just doing a self build at home on my summer house. I do like to research all the pros and cons so that I can do the best job possible within my budget so I find all of your videos extremely helpful, as do many others

    • @Username89039
      @Username89039 4 роки тому

      @@SteveRoofer Can't you just rough up and roller on another layer of GRP?

  • @epicduck5177
    @epicduck5177 3 роки тому

    A 3 layer felt system would have been the solution. Base layer nailed or install vapour barrier.