КОМЕНТАРІ •

  • @williamjames8233
    @williamjames8233 2 роки тому +13

    I also use the top of the planer to lay boards on after they have passed thru. Then I walk back around and pick them off the top and don't have to carry them around - especially helpful with long boards. The top ejection scheme would interfere with that.

  • @1915Woodworks
    @1915Woodworks 2 роки тому +6

    I’ve thought about this for a while. But every time I use it I end up stacking work pieces on top of it and remind myself why I never changed to this style. But I still think about it a lot 😅

    • @seamancustombuilds2553
      @seamancustombuilds2553 2 роки тому +1

      Yeah it removes that ability, for me it was worth it but won’t be for everyone

  • @brokenleadwoodworks
    @brokenleadwoodworks 2 роки тому +4

    Definite upgrade for this planer. Enjoyed it. Thanks for sharing.

  • @loufreda3266
    @loufreda3266 Рік тому +2

    Thank you for the demonstration. Looking forward to the installation of this part.

  • @dp91c
    @dp91c 2 роки тому +10

    Definitely made the right call putting the impeller back on the motor I think. It's used for both dust extraction and cooling. You could probably take it out if you still had dust collection hooked to the original port because it would pull air over the motor and cool it. I'm working on a similar idea right now from left over ducting parts so we'll see how it goes. Seems good so far. Good video.

    • @cassandraroads5461
      @cassandraroads5461 Рік тому +2

      Just a suggestion (I haven't tried it): Put a cover over the dust chute intake port on the fan body. This should reduce the loading of the motor, reduce the noise and probably improve the cooling air flow through the motor. However, like William James in his comment, I use the top as a temporary storage location, while I plane the work-pieces. So, the change in the video is not happening on my 735.

  • @vidpromjm
    @vidpromjm 2 роки тому +5

    Cool idea and thanks for sharing but I do think you should edit in a text screen to the video before you close stating that your reinstalled the impeller due to thermal concerns. Not everyone will click the""more" button.
    There was another youtuber who removed the impeller but they kept the original airway and their vac system provided enough airflow to keep things cool.
    edit: Or just pin a comment to the top here explaining the potential issue

  • @DonsWoodies
    @DonsWoodies Рік тому +1

    Just put that upgrade from Jacob on my planer. Like literally 5 minutes ago. Major improvement. I have a Rockler wall mount dust collector (the 650 cfm one) and it picks up all but a tiny bit of the chips, actually more than it did from the original port. Sound level, if it is different, it's so minor as to be unnoticeable. I'll someday cut the hole in the top plate and put that back on.

  • @markhopkins7204
    @markhopkins7204 Рік тому

    thanks for sharing..one on order!

  • @1stGregA
    @1stGregA Рік тому +4

    I try to avoid un-necessary work and tasks. (& expenses too) When I hook my dust collection up, I simply bungee cord the tube up and out of the way. (btw, looks like you need to do the same as yours impedes you walking front to back during planing which is un-avoidable) Mine is mounted to the mobile OEM cart, and when stowed away, I simply use 1 short bungee (over the top where you put your hole) to hold the feed/export tables upright. Peace

  • @drskvch5768
    @drskvch5768 11 місяців тому

    Roll Tide! Great video I am looking to get the planer and this looks like a well thought out mod.

  • @daveremillard6257
    @daveremillard6257 2 роки тому +5

    I respect everyones right to make whatever upgrades ???? they want, but I'm in the group that would NOT do this. The dust collection hose getting the way has not been an issue for me so why fix something that isn't broken? All that being said I did learn a little bit from the video about the machine so I do thank you for that.

    • @blueblur6447
      @blueblur6447 Рік тому

      Its like making a fast car even faster, better... If the motor isnt fighting the load of pushing chips it can cut easier.... If it has more energy to cut, it cuts better... If the motor has a easier load, in theory it will last longer... This particular upgrade I would leave the fan blade on though, its critical to motor cooling even if not used for chip ejection... Nothing wrong with the if its not broke dont fix it philosophy though. Happy wood working!

  • @kingdomofdirt5666
    @kingdomofdirt5666 Рік тому

    Now that I’ve actually seen a good install video on one of these, what’s the benefit over just using an elbow and aiming it straight up? Hook the dust collector to it. Just the table folding up? Great video, thanks for the details and showing the “mistakes” that’s always helpful

  • @webcrawler3332
    @webcrawler3332 8 місяців тому

    Looks like the system that came with it does WAAAAAAY better job than the aftermarket one

  • @stormbytes
    @stormbytes 9 місяців тому

    Cool video and nice shop!

  • @JamesMcCarty
    @JamesMcCarty 4 місяці тому

    I'll be honest, I just got this planer and I ran a 2x6 through it and I appear to have as many shavings popping out as you did on that very small piece. I'm just using a Shop-Vac hooked up to the stock dust port going through a cyclone.

  • @mfrit67
    @mfrit67 Рік тому

    Can a vacuum hose be connected directly to the blower output port (with the 4" plastic adapter piece removed)? Seems like the best of both worlds if possible.

  • @DanielTaylor-hn4ut
    @DanielTaylor-hn4ut 2 роки тому +1

    Best dust port answer I've seen for this machine. Really appreciate you sharing this. What kind of dust collection system do you have? May want to use same thing.

  • @radudelacluj
    @radudelacluj Рік тому +1

    Nice video, very helpful tip, Scott! Roll Tide!

  • @bijan4727
    @bijan4727 2 місяці тому

    Hi very creative and nice presentation. I have one question. What are those white panels on your garage door ? Do they reduce noise from going outside ? If so I would appreciate to let me know the name, the percentage of reduction in noise going outside, where I can get them , and an approximate cost. Thank you

  • @CycleTuber
    @CycleTuber 7 місяців тому

    Where did you get the interlock switch hold down?
    I 'm always looking for something to hold the switch on every time I service the machine.

  • @barkingshark6413
    @barkingshark6413 Рік тому +1

    Hmmm. Must’ve redesigned the extractor because my out feed table folds up about half inch under the port… probably after your video. Thanks.

  • @scottstillings8423
    @scottstillings8423 Рік тому +2

    For those of you with a 3d printer...make a fan just like the original but do not make the blades for chip extraction. The blades that face the motor are used for motor cooling, The other side of the fan is used for chip extraction. Just make the outside of the fan smooth so it does not act like a chip extractor. This should keep the part the same size but is only used to cool the motor.

    • @seamancustombuilds2553
      @seamancustombuilds2553 Рік тому

      That’s a great idea, maybe you can market that idea.

    • @bimaldimri8817
      @bimaldimri8817 Рік тому

      I’m thinking of taking off the fan and attaching a 2.5 hose to the default dewalt dust port . Hoping that would keep the motor cool. I will split my dust hose ( 4 + 2.5).

  • @fernandoquiceno
    @fernandoquiceno 9 місяців тому

    What’s your temp for the fan motor with and without the blades on? Curious.

  • @rw7532
    @rw7532 Рік тому +1

    I just bought the 735 and my in and out feed tables just arrived from Amazon. Did you leave your tables with the slight upward tilt on the ends (factory setting) or did you adjust the, to be flat with the planer bed? Thanks.

  • @striperseeker
    @striperseeker 10 місяців тому

    Nice upgrade. Can I ask what the digital read out is on the thickness guage? RIght in front of the wheel?

    • @directive5147
      @directive5147 6 місяців тому

      That's a gauge from Wixey. You get a lot more accurate and consistent thickness measurements compared to the one from Dewalt.

  • @NoHandleIsMyHandle
    @NoHandleIsMyHandle Рік тому

    This is for the 735X. I clicked on the title thinking it was 735. Those without tables don't worry about this.

  • @strykerliker
    @strykerliker 2 роки тому +1

    Can you tell me why there were more chips on the planer after you removed the fan blades? Also, I didn't quite understand why you wanted to remove them?

    • @seamancustombuilds2553
      @seamancustombuilds2553 2 роки тому +4

      I removed the fan for a couple reason, mainly it is no longer needed for chip ejection and is just blowing a large amount of air into the shop and could stir up dust, also this would hopefully provide more power to the cutter head if needed since there isn’t resistance from the fan blades. It’s also quieter without the fan.

  • @northsongs
    @northsongs 2 роки тому +2

    I like the way you think. And ROLL TIDE!!!

  • @brett328
    @brett328 2 роки тому

    Looked like a lot of chips coming out onto the bed, especially for a workpiece that's on about 1 1/2 inches wide.

  • @Mike-wv8gj
    @Mike-wv8gj 8 місяців тому

    Where can I buy this dust chute in Canada please?

  • @aux1z11
    @aux1z11 Рік тому +1

    my 735 doesn't make a mess at all it's still new in the box

  • @edwardkinsella342
    @edwardkinsella342 2 роки тому +1

    I have read some poor reviews on the Shelix cutter head. have you had any issues?

    • @seamancustombuilds2553
      @seamancustombuilds2553 2 роки тому +1

      I haven’t had a single issue and haven’t heard of anyone else having an issue with it.

  • @mdk2066
    @mdk2066 Рік тому

    If this works for you, great, but for me no. You can't use the top of the machine to slide boards back to the feed side, especially big material. You've disabled a perfectly good chip ejector. Compromised motor cooling. Just use an elbow or bungees to route the hose. As far as having to pop off the original port to fold the table, how long did that take?

  • @rexseven93
    @rexseven93 2 роки тому +7

    I wouldn't do this to mine, but if people watching are considering this, it would only work decently with a shelix cutter head. One of the things the integrated blower does is chop up the long chips that come off the standard knives. Also, if your purpose for this change is mostly to allow the outfeed table to fold up, wouldn't it be easier to cut a clearance hole in the outfeed table?

    • @7mmSTW154
      @7mmSTW154 2 роки тому +1

      I just experienced this tonight on my first use of this adapter. I was planing 1x6” cherry wood that was air dried over 10 years at this point. I did get some clogging issues on a short straight run of 4” hose. I was taking a little bigger bite with the planer, but I know the difference of that and way too much. Maybe 1/32” on a cherry 1x6” isn’t overdoing it. The planer will handle much more than that. I did however get less saw chips blowing around on the infeed table. I’d like to add a shelix cutter head someday so that should solve the clogging issue.

    • @rexseven93
      @rexseven93 2 роки тому +1

      l really don't see the point of this revision. Mine works great as and I just don't mind the table not folding up. A 90 Degree elbow handles dust extraction just fine. It is something they should have thought about, but it's far from a deal killer and the unit is still superior to any other benchtop planer I've used. It is almost a category between standing and benchtop.

    • @abetoymachine
      @abetoymachine 2 роки тому +2

      You don’t need to cut any clearance holes for the outfeed table to fold up - just raise the height until it clears.

    • @jacobelliott5792
      @jacobelliott5792 Рік тому +1

      Several hundred of my customers still running straight knives would disagree with you..

    • @terencenewlin5265
      @terencenewlin5265 Рік тому

      I seriously doubt that plastic impeller is chopping up any long chips. It wouldn't last very long doing that. My Delta planer with straight blades doesn't make long stringy chips. I doubt the Dewalt does either.

  • @floridasaltlife
    @floridasaltlife Місяць тому

    Didn't look to do any better than the internal blower into a bag

  • @erichbauer5554
    @erichbauer5554 Рік тому

    Expensive! Woo

  • @davidbondi
    @davidbondi 2 роки тому +4

    Sorry, I just don't get it. I have the same planer (haven't done the cutter head upgrade). I solved the issue with Rocklers 4" Dust Right Quick Connect elbow fitting for $18. The whole assembly comes off and works great. Not in the way. Didn't spend $65 and cut a whole in my $700 planer and void my warranty. I'm glad it works for you though.

  • @davidschreckengost7959
    @davidschreckengost7959 5 місяців тому

    Well first thing. Your running the board through and not cutting just rolling lol. Second i have seen so many of these videos crying about the port in the way of the trayif you wind up the planner the tray will work fine! ( im glad at the end it used the blades a tiny bit ). Lastly they make a hook attachment that holds thhose off to the side. And it can work on ether side. ( 35 bucks)

  • @randytidmore8021
    @randytidmore8021 11 місяців тому

    Roll tide 👍

  • @webcrawler3332
    @webcrawler3332 2 роки тому

    Why did you remove the impeller?

    • @seamancustombuilds2553
      @seamancustombuilds2553 2 роки тому +1

      I was hoping to eliminate the blower to allow more power to go to the cutter head and also keep from blowing dust around, I ended up reinstalling to help cool the motor

    • @webcrawler3332
      @webcrawler3332 2 роки тому +1

      @@seamancustombuilds2553 gotcha!

  • @jackmcclure6354
    @jackmcclure6354 2 роки тому +2

    I just keep my out feed table up by wrapping the electrical cord around it

    • @JasonPeltier
      @JasonPeltier Рік тому +1

      I have a bungee cord hooked to both tables across the top.

  • @djespo69
    @djespo69 2 роки тому +1

    Mines on wheels I just take it to the back patio and then sweep all the chips into the lawn

  • @arturorodriguez5492
    @arturorodriguez5492 Рік тому

    Dónde comprarlo

  • @TheDudeAbides.
    @TheDudeAbides. 2 роки тому +2

    Impeller fan is used to cool the motor. Taking it off is a bad idea.

    • @seamancustombuilds2553
      @seamancustombuilds2553 2 роки тому

      From thoroughly looking mine over I don’t see how the fan used for chip extraction would be used to cool the motor as it is completely enclosed

    • @ZomBeatBrainZ
      @ZomBeatBrainZ 2 роки тому

      Seaman Custom Builds @ 6:00 min the holes surrounding the fan blade shaft on the motor is where it gets the cooling from. Pulls air through the motor, does not blow on or into the motor. That’s how it’s able to extract chips and cool at the same time. I wouldn’t run it for extended periods without first checking to see how hot the motor gets. Looking at the fan housing, it almost looks like you could unbolt it and rotate it to redirect the exhaust up.

  • @eladsinay6914
    @eladsinay6914 2 роки тому +1

    i wanna see someone plane an epoxy board and see what happens. that stuff goes EVERYWHERE. thatll be the final challenge to sell me on this

  • @LanceMcGrew
    @LanceMcGrew 2 роки тому +22

    Nope - not going to butcher my brand new DW735. OEM setup works just fine for me. Extension tables are very easy to remove and store under planer on my roll around cart.

    • @joearrue6819
      @joearrue6819 2 роки тому +1

      also if you’re working with someone handing you back the pieces , the discharge gets in the way.

    • @rw7532
      @rw7532 Рік тому

      just bought the 735 and my in and out feed tables just arrived from Amazon. Did you leave your tables with the slight upward tilt on the ends (factory setting) or did you adjust the, to be flat with the planer bed? Thanks.

    • @msk3905
      @msk3905 Рік тому

      @@joearrue6819 weird i have zero issues with the dust port and tubing on mine, is the person coordinated?

    • @joearrue6819
      @joearrue6819 Рік тому

      @@msk3905 nah they only hve one arm

    • @Shotsmoky
      @Shotsmoky Рік тому

      Roger that Lance. I’ve seen a few complaints about the position of the dust collector port but it has never bothered me.

  • @colestephen4846
    @colestephen4846 2 роки тому

    Does anyone else get a ton of tear out with the 735?

  • @msk3905
    @msk3905 Рік тому +1

    Why not just put a 90 degree elbow on dust port turned away from you so its out of the way? Appreciate the work put into this but my 90 elbow keeps dust collection out of way when grabbing board in back and cost me like $12

  • @cadmus49
    @cadmus49 Рік тому

    easier to just unsnap discharge table.

  • @terrynewlin2846
    @terrynewlin2846 Рік тому

    Nothing to do with you removing and reinstalling the fan impeller. I've seen several comments elsewhere about the motor overheating or burning up. Quite an expensive repair. Some units not very old at that.
    BTW, I like the exhaust duct modification and would do that if I purchased this planer.

  • @linascibelli7592
    @linascibelli7592 Рік тому

    In theory it appears like it works nicely with 3/4” stock, however I would not do this as it interferes with raising the planner for thicker stock. 🤔 I’m referencing the perm solution to adding the cover back on.

    • @seamancustombuilds2553
      @seamancustombuilds2553 Рік тому +2

      This has no impact on raising the planer to the full capacity as the entire top section raises and lowers

  • @eladsinay6914
    @eladsinay6914 Рік тому

    Seems like it’s still throwing out chips from the front. And that’s with a narrow board. Now try a full size board and make it an epoxy and wood board and see what happens. That’s the real challenge. Epoxy, when planed , becomes statically charged and sticks. It gums up and blocks everything. So the real question if any of these videos are worth it is to test it against that level and do an epoxy board.

  • @Thomllama
    @Thomllama 2 роки тому

    ummm, just an elbow pointing up off the stock port? no modifying the case and the hose is outa the way, likely even more so watching you use it as it seems to be right in the way as you reach around the grab the piece coming out. Fan cools motor as well as chip extraction. This is a cool idea, but seems like a lot of extra work to accomplish no real benefits .. I guess the table flip, but I don't bother with that.

  • @civedm
    @civedm 2 місяці тому

    Nah I'm good. Im just going to do the elbow trick into a dust bag.

  • @Coolride1000
    @Coolride1000 6 місяців тому

    Don't think removing blower fan is a good idea, because it also cools the motor.

  • @willis23jm1
    @willis23jm1 Рік тому

    these people keep trying to sell items claiming to fix 1 issue and not explain that its cause multiple.
    the dam planer is ok from factory as is ...the blower is a plus as you wont need to worry about hooking it up to any vacuum..
    i can imagine if your vaccum system not working 1 day or you have to work on another location the planer would be in operable as it wouldn't be able to expel dust🤷‍♂.
    its also blocking the over head where naturally it an over pass for work pieces.
    i can recall u giving 1 reason for this mod and thats because you cant store planer up to the wall ... you can store it side ways to wall or just take off the dam support bed (easy on and off procedure)
    please dont waste your money to buy this mod and to destroy youe planer as i doubt i would buy it with that hole in it.... 3d print a cover so the need to damage origanal cover is not neccesary......... but then again they would charge a arm and a leg for these plastic piece 🤣

  • @bfirefighter3
    @bfirefighter3 Рік тому

    Useless info, whenever you’re cutting plastic with a hole saw run the drill in reverse. Cuts a lot cleaner

  • @douglingle1600
    @douglingle1600 2 роки тому

    No thanks ill keep mine original, not a big fan of modifying original design and function on tool.

  • @danielbaron2358
    @danielbaron2358 Рік тому

    Don’t put money out for this piece of junk. DeWalts customer service is very poor. Mine hade 15 minutes total of light duty and it popped the breaker each time I used it. The belt melted off planing a 4 inch wide piece of pine. Dewalt did nothing.