Carbon Fiber Test ASTM D7264 Test Method Flexural Properties of Polymer Matrix Composite Materials

Поділитися
Вставка
  • Опубліковано 9 лют 2025
  • Subscribe to my channel at
    / @frankbaconmachinery
    Check out our Website at
    www.frankbacon.com
    Frank Bacon Machinery is a world leader in tensile tester reconditioning and upgrading along with the world's largest inventory of material testing, quality control and inspection equipment. Please contact us today!

КОМЕНТАРІ • 6

  • @PocketRocket_
    @PocketRocket_ Рік тому

    How much specimen overhang do you have on either side of the span supports?

    • @frankbaconmachinery
      @frankbaconmachinery  Рік тому

      The ASTM specification calls out the exact specimen length required based on the thickness of the specimen. The overhang will depend on the total span length.

  • @zeinabmo357
    @zeinabmo357 Рік тому

    could you tell me sizes of your specimen , according to standard of ASTM D7264 thickness is 4mm and then span to thickness ratio is 32:1 how there you did set the span to 2.7 ?

    • @frankbaconmachinery
      @frankbaconmachinery  Рік тому

      We used the thickness ratio of 32:1 per ASTM D7264 and the span was 2.7 inches

    • @zeinabmo357
      @zeinabmo357 Рік тому

      @@frankbaconmachinery could you tell me please what is the thickness of specimen you used in mm .? thanks in advance

    • @frankbaconmachinery
      @frankbaconmachinery  Рік тому

      The thickness was .08" or 2.03 mm@@zeinabmo357