Carbon Fiber Test ASTM D7264 Test Method Flexural Properties of Polymer Matrix Composite Materials
Вставка
- Опубліковано 9 лют 2025
- Subscribe to my channel at
/ @frankbaconmachinery
Check out our Website at
www.frankbacon.com
Frank Bacon Machinery is a world leader in tensile tester reconditioning and upgrading along with the world's largest inventory of material testing, quality control and inspection equipment. Please contact us today!
How much specimen overhang do you have on either side of the span supports?
The ASTM specification calls out the exact specimen length required based on the thickness of the specimen. The overhang will depend on the total span length.
could you tell me sizes of your specimen , according to standard of ASTM D7264 thickness is 4mm and then span to thickness ratio is 32:1 how there you did set the span to 2.7 ?
We used the thickness ratio of 32:1 per ASTM D7264 and the span was 2.7 inches
@@frankbaconmachinery could you tell me please what is the thickness of specimen you used in mm .? thanks in advance
The thickness was .08" or 2.03 mm@@zeinabmo357