OUTLET INSTALLATION | 1 gang 2 gang 3 gang - House Wiring basics | Philippines

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • How to install 1 gang, 2 gang and 3 gang outlet. Safety tips and testing procedure. Basic House wiring. (Electrical) tagalog-paano mag install ng outlet? nc2
    Note: PEC standards must apply in any electrical wirings. Turn Off Circuit breakers while doing the job.
    Thank you for your time guys. Please do like and subscribe for more basic yet usefull electrical and controls video. God Bless😎
    OTHER USEFUL VIDEOS 👇
    3-WAY SWITCH Wiring Tutorial
    • 3 Way Switch - tagalog...
    WYE DELTA MOTOR CONTROL
    • WYE DELTA STARTER Wiri...
    Stop Start Wiring Control Circuit and Diagram
    • Stop Start Magnetic Co...
    FORWARD REVERSE STEP BY STEP
    • FORWARD REVERSE Motor ...
    On Delay Timer Wiring Diagram
    • ON Delay Timer Diagram...
    FLOATLESS RELAY WIRING
    • Floatless Relay Wiring...
    Stop Start with Overload Relay Connection
    • Magnetic Contactor Sto...
    • Overload Relay ( therm...
    OVERLOAD RELAY Function tutorials. tagalog
    OHMS LAW
    • OHMS LAW - Voltage Cur...
    24 HOUR TIMER FUNCTIONS
    • HOW TO SET 24 HOUR CLO...
    • Multimeter Paano guma...
    How to use MULTIMETER tagalog video
    STOP START w/ INDICATOR LAMP
    • STOP START w/ INDICATO...
    • HOW TO SPLICE A WIRE -...
    How to Splice a Wire video
    MAGNETIC CONTACTOR PARTS AND FUNCTIONS
    • Magnetic Contactor Par...
    VOLTAGE TESTER
    • VOLTAGE TESTER NEON SC...
    HOW TO COMPUTE ELECTRIC BILL
    • Electric Bill Computat...
    7 WAYS TO REDUCE ELECTRIC BILL
    • HOW TO LOWER ELECTRICI...
    POWER FORMULA
    • POWER CURRENT VOLTAGE ...
    HOUSE WIRING TUTORIAL
    • HOUSE WIRING TUTORIAL-...
    PHOTOCELL with Magnetic Contactor
    Wiring/Diagram-street lights
    • PHOTOCELL w/ Magnetic ...
    Magnetic Contactor VS Mechanical Relay
    Uses and Function
    • Magnetic Contactor VS ...
    SUBMETER INSTALLATION
    • SUBMETER INSTALLATION ...
    MECHANICAL RELAY WIRING
    • RELAY WIRING TUTORIAL ...
    MANUAL OFF AUTO MOTOR CONTROL
    • MANUAL-OFF-AUTO Motor ...
    FLOAT SWITCH WIRING AND DIAGRAM
    • Float Switch wiring an...
    #localelectrician

КОМЕНТАРІ • 212

  • @LocalElectricianPH
    @LocalElectricianPH  Рік тому +1

    Ito po Supplier natin mga Master. Electrical Plumbing and Tools shope.ee/2KzfFFhX8K

  • @marztv1853
    @marztv1853 4 роки тому +4

    Laking tulong to sa mga bagohan.

  • @kevinaarontambalong6697
    @kevinaarontambalong6697 2 роки тому +1

    Salamat sa video nyo po sir?ako na lang nag outlet lahat ng outlet ng bahay ko :) malaking tulong

  • @boytabirao6029
    @boytabirao6029 2 місяці тому +1

    Nadali mo bro malinaw ang demonstration mo very good tanong ko lang ilang outlet ang allowe sa 20 amp

  • @zorenbasilio8160
    @zorenbasilio8160 3 роки тому +1

    Salamat po ng marami may natutuhan po ako

  • @normanbayato2205
    @normanbayato2205 4 роки тому +4

    Nice content po

  • @jonatst.v3108
    @jonatst.v3108 Рік тому +1

    Nice boss maganda Ang pagka explain mo good job

  • @xxzirkoh1xx
    @xxzirkoh1xx 3 роки тому +1

    very good lodi ...tama ang diskarte mo..

  • @edbuenafe5603
    @edbuenafe5603 3 роки тому +2

    Thanks for sharing sir nice tutorial po

  • @wallypoblete6547
    @wallypoblete6547 3 роки тому +1

    tnx poh makakapaglagay nah aqoh ng extra outlet, mahal singil eh 350 per butas daily rate nah un

  • @galawangelectrical
    @galawangelectrical 4 роки тому +1

    thanks sa pag share nito lods,!

  • @azazael3014
    @azazael3014 2 роки тому +1

    Salamat po!!! I learned.

  • @jaicabiais8863
    @jaicabiais8863 4 роки тому +2

    Good job sir. Thanks for sharing

  • @kevincrisostomo2055
    @kevincrisostomo2055 2 роки тому +1

    Maraming Salamat!

  • @jf-techmodule544
    @jf-techmodule544 4 роки тому +2

    Nice sir keep it up

  • @masterjoeelectrical
    @masterjoeelectrical 3 роки тому +1

    hi verry informative

  • @japormstamayocollado4196
    @japormstamayocollado4196 2 роки тому +1

    Good idea idol

  • @jaijaiph4210
    @jaijaiph4210 4 роки тому +2

    Salamat sa pag share boss.

  • @anthonycontreras8118
    @anthonycontreras8118 Рік тому +1

    Salamat po

  • @dongreysaluta7737
    @dongreysaluta7737 2 роки тому +1

    ayos boss

  • @kAtkAt298
    @kAtkAt298 3 роки тому +2

    salamat po!!

  • @gracesanjuan1566
    @gracesanjuan1566 2 роки тому +2

    Thank you boss. Wala akong matutunan sa Online class🤦

  • @ashmocadi8470
    @ashmocadi8470 2 роки тому +1

    salamat po sa info
    tanong ko lang din po pano po kung hindi color code yung L at N pano po malaman kung mag add ka ng outlet nang hindi dun mismo sa outlet mag jumper

  • @patsoy1329
    @patsoy1329 2 роки тому +2

    lods ok lang ba mag swap yung two wires pgdating sa another outlet? same color lng yung wires namin, di namin alam alin ang LINE 1. may kuryente din kase sya kahit nag swap. ok lng ba ang ganyan lods? kase 20yrs na yung amin, wla namang nangyayareng masama

  • @charissedelacerna1427
    @charissedelacerna1427 21 день тому +1

    Anong type o tawag s breaker n yan? Bagong model b yan?

  • @doremonginahasa1202
    @doremonginahasa1202 Місяць тому +1

    Hindi po sa init.ang magiging problema oi don kaoag nag loss conection lahat apektado po

  • @jomerramos1423
    @jomerramos1423 10 місяців тому +1

    Sir tanong ko lang diba puwedeng pagsamahin sa iisang linya ang lighting at outlet?

    • @LocalElectricianPH
      @LocalElectricianPH  10 місяців тому

      For general use...pwedi naman..for special use..hindi...at dapat d ka lalagpas sa 80% max load ng outlet at ckt mo. Minimum of 20A cb at 3.5 mm² wire

  • @JoenaBangayan
    @JoenaBangayan Рік тому +1

    Ok lang ba na yung jumper sa line napunta sa neutral??

    • @LocalElectricianPH
      @LocalElectricianPH  Рік тому

      Jumpet sa line papuntang nuetral po ba Sir? Wag po..baka mg short..makuryente po kayo

  • @alvinl.2445
    @alvinl.2445 3 роки тому +1

    sir paano ang wirings ng type g wall socket. nais ko sana palitan ang type a ng type g since lahat ng appliances namen eh type g ang plug pra sana di na gumamit ng adator.
    kase 3 cables ang type g. ung existing na type a wala nmn earth terminal. thanks po

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому +1

      Kailangan nyo magoa install ng grounding sir. Pero f hindi kau magpa install.. gagana parin naman yan kahit hindi na lagyan ang ground terminal sir

  • @marvincancino2530
    @marvincancino2530 Рік тому +1

    Paanu kung yung mga wire lods walng coding hindi n mlaman yung line or neutral,bali 10 pcs n outlets balibaliktad yung connection nya ok lng b yun?

    • @LocalElectricianPH
      @LocalElectricianPH  Рік тому

      Yes po ok lng yan..gagana parin naman kahit baliktad..f gusro mo malaman ang live wire...pwesi rin po gamitan nyo tester..may video dn tayo nyan sa playlist

  • @ardrichbryantarenio6055
    @ardrichbryantarenio6055 8 місяців тому +1

    Sir gud am tnong lng po ano ho pinaka matibay na outlet ngaun sir

  • @bestmoments1063
    @bestmoments1063 2 роки тому +1

    Lodi, pwede ba mag multiple outlets then 5 or more light bulbs in 1 circuit? 30A po yung circuit breaker na gamit kopo. Safe po ba?

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Pwedi po 5.5 mm na wire gamitin mo sa 30A breaker... pwedi rin 20A sa 3.5mm na wire. Basta hindi kau lalagpas sa 3600 watts load

  • @damusiclovers9475
    @damusiclovers9475 Рік тому +1

    Gudday sir pag line to line po ba ibig sabihin.. 110v to 110v? Pag line to nutral nmn po eh.. 220v to ground? Tama po ba? Salamat po

  • @markjenry1591
    @markjenry1591 3 роки тому +1

    Hello po. Nagpaplano po ako bumili ng panther extension na my surge protector. Question ko po is Is it safe to use this as a direct power source. I'm planning to change the cord to PDX and connect it directly to the main line. Is that advisable? Thanks po.

  • @edwindalagan7753
    @edwindalagan7753 2 роки тому +1

    Sir pwede po ba ikabit ang doplex wire sa 12 AWG please reply po...

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Pdx po pwedi 12 awg pero f 12 awg na stranded...d pwedi..d yan papasok...kailangan mo pa dugtungan ng solid wire

  • @ronfajardo5899
    @ronfajardo5899 2 роки тому +1

    anung magandang outlet at wire para sa breaker 32A at gamit ko dalawa ilaw dalawang electric fan at 3 power Amplifiers 10A lang with Processors

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Isang circuit breaker lng po ba kayo? 20A lng po ang breaker ng mga karaniwang outlet Sir. Mataas n yang 32..mg lagay nlng po kayo ng panel board. 40A main tpus 15A sa ilaw 20A sa mga appliances amd 20A sa amplifiers

    • @ronfajardo5899
      @ronfajardo5899 2 роки тому +1

      @@LocalElectricianPH opo pambahay lng connection

    • @ronfajardo5899
      @ronfajardo5899 2 роки тому +1

      @@LocalElectricianPH panu kung isang linya lang outlet 3 Yung saksakan ilang AMPERAHE dapat sa pang wire at outlet po?

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Minimum 3.5mm wire at 20A breaker

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Ihiwalay nyo nlng po hindi pwedi yang 32 Amps sa ordinary outlets

  • @alfonawa1127
    @alfonawa1127 2 роки тому +1

    Sir ask lang papano mag install tatlong sakit bago ang isang ilaw po

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Ito po link.pki play. ua-cam.com/video/sVyrkkC8HzE/v-deo.html

  • @johnraylagangga6186
    @johnraylagangga6186 2 роки тому +1

    Lods Tanong lang Po pwede ba yan mabaliktad Yong dilaw mapunta sa itim pag walang coding

  • @ericputian975
    @ericputian975 5 днів тому

    Sir yun yelow at black na wire, same specs lng yan na 3.5 strander wire.

    • @LocalElectricianPH
      @LocalElectricianPH  4 дні тому

      Yes same dapat

    • @ericputian975
      @ericputian975 4 дні тому

      @@LocalElectricianPH sir pde ba 30 amp sa power outlet, kasama na inverter washing machine, tv fan or any apliances na mahina lang amp?

    • @LocalElectricianPH
      @LocalElectricianPH  4 дні тому

      @ericputian975 d naman po magkasya ang 5.5mm na wire sa outlet sir

    • @LocalElectricianPH
      @LocalElectricianPH  4 дні тому

      Pwedi kayo mg 20A at 3.5mm² thhn wire..reommended sa single ckt breaker set up

    • @ericputian975
      @ericputian975 4 дні тому

      @@LocalElectricianPH ano po yun sinabing nyong awg, thhn din ba yan

  • @veyyian6930
    @veyyian6930 2 роки тому +2

    Good day sir, pwedi po ba yung royu "#14 thnn wire 35ampacity" sa 20amps breaker at socket?. Kasi base sa mga napapanood ko yung #14 is 15 amps lang daw pero sa website ng royu is 35ampacity yung nakalagay sa #14thnn nila. Salamat po sir

  • @George_backyard24
    @George_backyard24 3 роки тому +1

    Pano yan sir. Di ba pwedeng 220 volts dba jyan usually yung gina gamit aa bahay?

  • @rodolfobagacay5646
    @rodolfobagacay5646 2 роки тому +1

    Sir pwede po ba tig 3 gang agad ang ilagay sa 20a n breaker

  • @jeannedorado3341
    @jeannedorado3341 2 роки тому +1

    Ganun parin po ba boss pag dalawang linya pa yung irerekta

  • @rpnbeltran1022
    @rpnbeltran1022 3 роки тому +1

    Sir pwede po ba mag splice ng additional outlet galing po sa switch na malapit sa paglalagyan po ng new outlet?

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      Pwedi naman po yan isama ang ilaw at outlet sir sa mga single ckt breaker. Basta 12mm qng wire at 20 amps ang brraker

    • @rpnbeltran1022
      @rpnbeltran1022 3 роки тому +1

      @@LocalElectricianPH yes po sir 3.5 ang wire tapos 20A po ckt breaker. Sana may tutorial ka sir. Salamat

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      Meron po nyan sir . Pki check sa electrical wiring video playlist

  • @marvelkayferfejer8022
    @marvelkayferfejer8022 Рік тому +1

    Boss ,paano po gagawin kung magkaibang direction yung mga outlet...yung isa,west ...yung isa, east... San po mag splice?

    • @LocalElectricianPH
      @LocalElectricianPH  Рік тому

      Maglagay kayo ng junction box Sir or pull box. Or utility box...or kahit sa mismong outlet box na kayo mg splice

    • @johnsantos4706
      @johnsantos4706 9 місяців тому +1

      Same din po ba kung 5co na tag 2gang ang process by tapping / splicing to co1 to co2 to co3 to co4 to co5? Or pagsamahin ung 6wire ng live at 6wire ng neutral sa iisang junction box alin po mas safety thanks po sa reply mga master

    • @LocalElectricianPH
      @LocalElectricianPH  9 місяців тому

      Same lng naman po yan..basta hindi shorted..pagsamahin lang line terminals at nuetral terminals. Parallel connected either way po

  • @harcaype
    @harcaype 2 роки тому +1

    kailangan po ba ang ground wire sa mga outlets? o optional lang yun? at gagana din ba itong 2-wire na to sa universal socket type?

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Sa mga small appliances natin Sir mapapansin nyo dalawang pin lng po yan..kaya gagana po yan kahit walang ground...yung mga meron ground po although safer f may ground specially sa mga special purpose outlets like refs ac microwave heaters na mga 3 pin plugs po. Yun ang need na universal or 3 pin sockets

    • @harcaype
      @harcaype 2 роки тому +1

      @@LocalElectricianPH thank you. pero wala naman pong problema kung gagamitin ung universal socket sa small appliances no? considered po ba na small appliance ang 55 inch flat screen led tv?
      pag 3 pin socket din po ba dalawang wire lang din kailangan?

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому +1

      Pag 3 pin socket..may 3 terminals yan ang 3rd nyan is ground wire. F wala naman kayong abang na ground wire..pwedi naman oo yam gamitin na hindi lalagyan ng ground connection. Dagdag ko lang po pag 2 pin plug ang appliances. So gagana yan at pwedi yan gamitin sa 2 o 3 pin socket. Usually mga 3 pin plugs kasi yun yung may mga metal body parts intended for personal grounding protection

    • @harcaype
      @harcaype 2 роки тому +1

      @@LocalElectricianPH maraming salamat po! May plan ksi ako ngayon to extend wall sockets kso walang mga abang na ground wire. Also lahat currently kasi naka 2pin lang kaya ang dami naming adapter. Kaya gusto ko sya palitan lahat ng 3 pin universal sockets.
      Last question po. Currently may 11 installed wall outlets kami. Given na magdadagdag kami ng more or less 20-25 wall outlets. May point of concern na po ba ito sa circuit breaker?
      Note po na 4 - 5 lang po na outlets doon ang gagamit ng big appliances. And may existing n rn n aircon. Meron dn isang outlet na kakabit ang isang 55 inch oled tv

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому +1

      Meron yan dapat proper computation ng schedule of loads Sir para iwas overload. 1 circuit breaker of 20A ay kaya ang total loads of 16 Amps. Tpus ang isan outlet ay may standard conputation of 180VA meaning f 2 gang outlet is 2 180VA or watts sa termino natin per outlet. Dapat hindi lalagpas sa 16A ang total load nyo sa 20A CB

  • @hermiebagalay5761
    @hermiebagalay5761 Рік тому +1

    Pwede ba ipasok na jamper wire is 5.5mm²

  • @buildonbudgetph4662
    @buildonbudgetph4662 3 роки тому

    Boss, pa suggest ng specs for portable welding extension cord. Pwedi na po ba ang gauge 8 wire? Thanks!

    • @buildonbudgetph4662
      @buildonbudgetph4662 3 роки тому

      Max 99 amps lang po usually settings ko sa machine. Thanks!

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      Mas safe atleast 100% ng max current sir. Pero base on experience yung mga portabpe welding machine namin dito sir d naman ng t trip sa 40amps at number 8 na wire..pero f umiinit napo wire nyo sir.delicado po yan nasa sa inyo napo yon sir. Mahal dn kasi malalaking wire

  • @sudorikaetinage3548
    @sudorikaetinage3548 2 роки тому +1

    Paano Po pag pa cross ung jumper tas circuito ok lng din Po ba?

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому +1

      Ok lng naman basta hindi shorted. Pero mas mainam na hindi magka dikit ang wire sir kasi pag uminit yan mas delicado

    • @sudorikaetinage3548
      @sudorikaetinage3548 2 роки тому +1

      @@LocalElectricianPH salamat Po, ibig sabihin sa pag terminate pa din

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Yes..safety first po

  • @chinoyvideos5570
    @chinoyvideos5570 2 роки тому +1

    Sir pano po 10 outlet same lang rin po ba lahat same sa ginawa mo

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      May limit po yan Sir..dependi sa mga load nyo po at capacity ng circuit wire at breaker po

  • @reymartsalazar111
    @reymartsalazar111 2 роки тому +1

    Sir anong size Ng wire nung nkakabit sa breaker na galing sa line

  • @joshuachu2445
    @joshuachu2445 Рік тому +1

    Sir ok lang ba ang Universal adapter jan? Tapos binaliktad ko, yung neutral ng plug (left side) ang nala plug sa L.

    • @LocalElectricianPH
      @LocalElectricianPH  Рік тому +1

      Ok lng yan Sir. Baliktaran naman po basta AC. Pero next time. Mas better follow standard.

    • @joshuachu2445
      @joshuachu2445 Рік тому +1

      @@LocalElectricianPH copy po sir maraming salamat. Baliktad ko kasi malaki ang hugis nang adapter, di ko mapindot ang switch ng extension wire. Takot lang ako baka masira ang computer ko.

    • @LocalElectricianPH
      @LocalElectricianPH  Рік тому

      D yan masira Sir. Walang polarity f AC voltage. Kaya pwedi mabakiktad

    • @joshuachu2445
      @joshuachu2445 Рік тому +1

      @@LocalElectricianPH sir ma recommend nyo ba akari brand?

    • @LocalElectricianPH
      @LocalElectricianPH  Рік тому +1

      Ok naman po yan sa small appliances..mas better parin panasonic or anam or schnieder

  • @jirahlauz5164
    @jirahlauz5164 3 місяці тому +1

    Pano po pag may usb slot?

    • @LocalElectricianPH
      @LocalElectricianPH  3 місяці тому

      Same wiring po meron dn ako video nyan outlet with usb nasa playlist

  • @user-jc8iz6re3e
    @user-jc8iz6re3e Рік тому +1

    Sir bakit yung wiring mo sa 3gang outlet iba sa ibang video kasi yung wiring nila sa 3 gang is magkajumper yung magkakatabi

    • @LocalElectricianPH
      @LocalElectricianPH  Рік тому

      For fewer and low powered load..pwedi naman ganito jumper...pero f maramihan load.na halos abot na ang max capacity. At 80% prefer ko ang splicing...

  • @hwfranjr
    @hwfranjr Рік тому +1

    Needs captions,l😂😂😂😂😂

  • @willycanlas9393
    @willycanlas9393 3 роки тому +1

    sir paano malaman un line or neutral sa breaker .salamat.

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      ua-cam.com/video/wgdQ6Z_CYq4/v-deo.html
      Paki check po itong vid sir

  • @DaDi-wz4hd
    @DaDi-wz4hd 7 місяців тому +1

    Parang nalito ako sa 1 gang

  • @babyanswer
    @babyanswer 3 роки тому +1

    Sir, balak ko kasi palitan yung aircon outlet namin, ok lang ba kung 2-gang outlet ang ipapalit ko?

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      Yung aircon outlet gamitin nyo sir

    • @babyanswer
      @babyanswer 3 роки тому +1

      @@LocalElectricianPH di na kasi namin gamitin yung outlet para sa aircon. Plano sana namin gamitin ang outlet para sa wall fan. Kaso ang outlet ang yung para sa aircon.

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      Ok lang yan Sir. 2 gang po

    • @babyanswer
      @babyanswer 3 роки тому +1

      @@LocalElectricianPH maraming salamat sir. Palitan ko na yung aicon outlet ng 2 gang.

    • @babyanswer
      @babyanswer 3 роки тому +1

      @@LocalElectricianPH ano klase wire pwede gamitin sir?

  • @nikkiwho2980
    @nikkiwho2980 4 місяці тому

    daisy chain pala ang outlet

  • @andressabat6006
    @andressabat6006 2 роки тому +1

    Pano mamalaman kung may short cirkit ser

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Multitester po. Either continuity test. Short or ground testing. Or megger.insulation test. Meron sa tayo video f paano gumamit ng mutitester sa playlist at videi disction po

  • @andressabat6006
    @andressabat6006 2 роки тому +1

    Ano pinag kaiba ng L AT N

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Line and Nuetral po. Buhay o may kurtente ang Live. Return naman po ang nuetral..wala po yang kuryente

  • @markkenneth2299
    @markkenneth2299 3 роки тому +1

    Boss paano naman ang tamang paraan sa pagkalas sa outlet?

  • @emeliobesa2484
    @emeliobesa2484 2 роки тому +1

    Gud morning po,sir saan Banda po yung electrical school nyu po,

  • @HazelVM
    @HazelVM 3 роки тому +1

    Bakit naka color coding boss? Pwede ba kahit hindi naka colore coding?

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      Pwedi naman po..para lang po yan sa tracing sir. Para mas madali f may color coding..

  • @user-tr9or8pg8v
    @user-tr9or8pg8v 6 місяців тому +1

    Ano po ang size ng wire ng ginamit niyo sa jumper

    • @LocalElectricianPH
      @LocalElectricianPH  6 місяців тому

      3.5 mm² po

    • @user-tr9or8pg8v
      @user-tr9or8pg8v 6 місяців тому +1

      Standard po ba yung 3.5 mm sa lahat ng outlet and switch ?thanks po

    • @LocalElectricianPH
      @LocalElectricianPH  6 місяців тому

      @user-tr9or8pg8v yan ang minimum standard po sa outlets with 20A cb sa switch at ilaw...2.0 mm² at 15A cb ang minimum standard

    • @user-tr9or8pg8v
      @user-tr9or8pg8v 6 місяців тому +1

      Maraming Salamat po

    • @LocalElectricianPH
      @LocalElectricianPH  6 місяців тому

      @user-tr9or8pg8v welcome sir

  • @aturservice8360
    @aturservice8360 2 роки тому +1

    Ok lang ba 3 gang lahat?

  • @gizelaoblad3322
    @gizelaoblad3322 3 роки тому +1

    Boss magkano po kaya gagastosin pag nagpa gawa ng ganito? Kasama po labor?

  • @jamesroble3321
    @jamesroble3321 3 роки тому +1

    Sir anu size wire gamit mo

  • @fudgeup90
    @fudgeup90 2 роки тому +1

    Ano pong size ng wire?

  • @niceguywix3305
    @niceguywix3305 3 роки тому +1

    boss ano magandang brand ng outlet?

  • @melvinsanjose7113
    @melvinsanjose7113 2 роки тому +1

    pano mag wiring ng "Tigang" 🤔

  • @jericcastillo4286
    @jericcastillo4286 2 роки тому +1

    SUBScriber nyoko Boss, pede idagdag na outlet ay 16 AMpere nakalagay? yung old 2 gang kaso 10 AM ang nakapangalan ( gawin ko 3 gang from 2 gang). Thanks

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Pwedi naman po basta hindi overloaded boung ckt

    • @jericcastillo4286
      @jericcastillo4286 2 роки тому +1

      @@LocalElectricianPH Add sana ako isa. Pede pa po ba kahit ung isa outlet ay Extension nakasaksak 3 gang ( Laptop, monitor, Cellphone)? ung 1 ay Electricfan-60 Watts. Add sana ako isa pang gang para sa isang pang CP.
      Pero kinompute ko pa kaya nmn ng 15A breaker ang buong 4 na kwarto namin outlet, Labis pa. Khit ba ganon. Masusunog pa din outlet ko?

    • @LocalElectricianPH
      @LocalElectricianPH  2 роки тому

      Hindi naman po masusunog basta hindi overloaded..tpus ang standard breaker sa outlet po 20A minimum with 3.5mm wire

  • @cba27musics54
    @cba27musics54 Рік тому +1

    Idol paano magkabit sa pagja jumper

  • @aquaponicsbackyardfarmingp2265
    @aquaponicsbackyardfarmingp2265 3 роки тому +1

    ok na yung "lods o lodi",, wag lang guys,,,guys guys,,sakit na sa tenga masyado ng gasgas sa mga blogger

  • @DavidBerquist334
    @DavidBerquist334 3 роки тому +3

    In a real circuit wouldn't you wire nut that splice or crimp or solder

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      Wire nut will do Sir. Have a nice day.

    • @DavidBerquist334
      @DavidBerquist334 3 роки тому +2

      Is your 240 volt 1 live wire to neutral like in Europe or 2 live wires like in the USA what is your color code USA is red black blue live white neutral 14 gage wire 15 amps 12 gage wire 20 amps

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      We have line to line in cities and line to nuetral supply in provinces sir. Same color coding RYB live white is neutral

    • @DavidBerquist334
      @DavidBerquist334 3 роки тому +2

      @@LocalElectricianPH since it's 240 can people from Germany England France where it's 220/240 line to neutral use there small appliances there while they visit
      Are the outlets marked 220 or 110 the ones here 220/240 have different receptical
      On the lights are switches double pole or do they switch one side of the 220

    • @LocalElectricianPH
      @LocalElectricianPH  3 роки тому

      We only have 220 t0 240 supply here sir. Thats 110 to 110 line to line and zero to 220 neutral to line supply voltages. For the receptacle. No worries we have a lot of adaptors sold in malls or small e shops

  • @boraknaytv67
    @boraknaytv67 Рік тому +1

    Boses robot

    • @LocalElectricianPH
      @LocalElectricianPH  Рік тому

      Hehe..pasensya po..d po kasi ako marunong mg edit para sa boses Sir. Ito lng talaga boses ko po. Delete ko nalang po ang video po

    • @boraknaytv67
      @boraknaytv67 Рік тому

      @@LocalElectricianPH oks lng yn lods

  • @japormstamayocollado4196
    @japormstamayocollado4196 2 роки тому +1

    Good idea idol