Earth Electrodes - 3 Wire Testing Example (Part 3)

Поділитися
Вставка
  • Опубліковано 6 сер 2024
  • Testing an earth electrode using the 3 wire technique with 2 temporary electrodes. Additionally a look at two other methods using a current clamp, or a voltage and current clamp.
    This is part 3 in a series on earth electrodes.
    ► Support this channel:
    Patreon: / jwflame
    PayPal Donations: xo4.uk/?PPP
    ► Social Media:
    Twitter: / jwflame
    Facebook: / jwflame
    Instagram: / jwflame
    ► Contact info, sending stuff in: etc.:
    xo4.uk/?YTT
    ► Website - More on this video and many other subjects
    Website: www.flameport.com
  • Наука та технологія

КОМЕНТАРІ • 93

  • @leeedwards3783
    @leeedwards3783 9 місяців тому +3

    Great series on earthing rods. I really find you easy to understand. You make it all understandable. Thanks

  • @azizahmedmuhammad4124
    @azizahmedmuhammad4124 2 роки тому +3

    I am very glad to have such a man whose knowledge, experience and expertise guide us in every field of electricity. Your great work will be fruitful for generations. Thank you sir

  • @muzikman2008
    @muzikman2008 4 роки тому +1

    Great video John, always a good source of refreshing my skills 🙂 clear and concise.

  • @jo76563
    @jo76563 4 роки тому

    Excellent information, thanks John

  • @relobmit
    @relobmit 4 роки тому +4

    I think the most important conceptual point here is that the marginal increase in resistance of the electrode (rod) under test decreases as distance from the rod goes up. This means that as you go further away, eventually the resistance of the rod reaches a maximum value and will not increase thereafter. This is because the increase in resistance owing to distance is more than made up for the decrease in resistanace due to an increase in current path surface area. So the resistance between 2 rods at 30m could be the same value as the same rods 300 miles apart (asumming the same ground conditions).

  • @coralbay00
    @coralbay00 2 роки тому

    Awesome thanks 😊
    Never had to do this test before in My 20 years. Nice to see the practical example 👍

  • @train4905
    @train4905 4 роки тому

    Exellent demo sir.well done.

  • @e5Group
    @e5Group 4 роки тому +6

    Get outta my garden John 😬
    You promised my lawn a mow! 🤣
    Awsome stuff as always mate 👍💪

  • @paulhamilton3993
    @paulhamilton3993 4 роки тому

    John, Great vid, tks!

  • @paultipton743
    @paultipton743 4 роки тому +1

    I've only seen the earth electrode test done once back in the late 90s for a remote located 2 x double stacked porta kabin office with lightning protection fitted and earthed at all 4 corners for an air control tower for Raf helicopter pilot training.

  • @Xclub40X
    @Xclub40X 3 роки тому +3

    1:48 as JW leads us all up the garden path.

  • @leekidman6128
    @leekidman6128 4 роки тому +9

    I used to love this channel but its gone too rock and roll John! 3 stripes on a jumper? Really?

  • @leila6443
    @leila6443 Рік тому

    It was super helpful
    Thanks 🙏🏼

  • @yousofalisohrabi6808
    @yousofalisohrabi6808 2 роки тому

    Was very useful thanks

  • @amandalynch8026
    @amandalynch8026 4 роки тому

    Thanks John

  • @paulf1767
    @paulf1767 4 роки тому +1

    Thank you John, super simple to understand thanks to your methodical way of working. Any chance of a 4 wire test being uploaded please?

  • @The4Qman
    @The4Qman 4 роки тому +4

    Great video John, only had to do this once myself.
    I have a video idea, I recently had to setup a last man out switch for a large commercial property, switching several lighting circuits. This is something you could setup in your lab and maybe useful to others.

    • @millomweb
      @millomweb 4 роки тому

      Strange request as it's bespoke circuitry and any customer wanting similar may have different requirements - it's not a 'one size fits all' type wiring.

    • @The4Qman
      @The4Qman 4 роки тому

      @@millomweb not a request, just an idea.

    • @millomweb
      @millomweb 4 роки тому +2

      @@The4Qman What he sets up may not match what the customer wants. So much is done by copycat. That's why in the central heating world we have S plans and Y plans. So people can copy others' mistakes.

  • @shoaib864
    @shoaib864 4 роки тому

    Many thanks

  • @MalagasOnFire
    @MalagasOnFire 4 роки тому +6

    Thanks for the practical video on earth rod testing as well referencing books, guidance. Sugestion: can you revisit the same place in summer next year and test the rod to test with dry soil?

    • @jwflame
      @jwflame  4 роки тому +10

      Certainly can.

  • @leebrown3895
    @leebrown3895 4 роки тому

    How would you test on a off grid solar panel system..ie from the transfomer/inverter..?

  • @ats89117
    @ats89117 4 роки тому +2

    You could probably significantly increase your subscriber count if you did a video of you using the trampoline!

  • @movax20h
    @movax20h 4 роки тому

    Very useful video. I have never seen this test and measurement done myself, so it is cool to see it. I have a question. Why the resistance doesn't change when you move the potential probe stake? What is theory behind this measurements. I guess it has something to do with the Ohm/squares.

  • @gearstil
    @gearstil 3 роки тому

    Hello, at minute 17.00 I didn`t quite understand how that method succeed in measuring only the Resistance of the electrode under test. The current is also flowing through R1, R2 and R3 in order to complete the circuit.

  • @ubuntuscorpious
    @ubuntuscorpious 4 роки тому

    Hi John. Great video. Could I request a topic for your next one? I recently hooked up an old caravan (that was working perfectly when connected at home) to a powered site and found that every time I tried to use any load it tripped the RCD in the supply box. After checking the fuse board I found an earth-Neutral connection in the caravan. This makes sense, some current is returning from the load via the earth wire and bypassing the RCD in the supply box. My question is, what is the purpose of the earth-neutral connection and how is a caravan wired so it can be connected to either an RCD or no RCD protected supply?

  • @mattbaker.digital
    @mattbaker.digital 3 роки тому

    Are the depths of the temporary electrodes irrelevant so long as distance from each meet the guidelines and the resistance is within limits?

  • @Petertronic
    @Petertronic 4 роки тому

    Years ago a relative of mine had a conservatory build over their earth rod. A live-earth fault occurred (a foot of their fridge had crushed the cable) and the exposed metal of all their appliances was live.

    • @millomweb
      @millomweb 4 роки тому +2

      Not a good earth rod installation then. A conservatory should not have affected it.

    • @Petertronic
      @Petertronic 4 роки тому

      Haha, nothing was good about that old house, which was in the middle of nowhere in rural Staffordshire. The entire wiring was a bodge job.

  • @ppdan
    @ppdan 4 роки тому

    I am wondering, is that low enough for a UK installation?
    Here in Belgium it MUST be under 100 Ohms, but you'll still need lots of RCDs to have a compliant system (whole house, bathroom, lights, one per 16 sockets, ... etc).
    It is advised to be under 30 Ohms, which most installations are. In that case you are only required to have 2 RCDs, one 300mA for the whole house and another 30mA for bathroom and some appliances (water heater, washing machine & dryer).
    I am not 100% sure but I think there are case where you may have more than 100 Ohms here, but it would require some annoying things like a 30mA hole house RCD ... etc

    • @jwflame
      @jwflame  4 роки тому

      Almost all RCDs for UK homes are 30mA, and virtually all circuits have them.
      Theoretical maximum with a 30mA RCD is 1667 ohms, but generally under 200 is considered acceptable.
      Some older TT installations have a 100mA RCD, maximum for that is 500 ohms.

  • @CoolJosh3k
    @CoolJosh3k 4 роки тому +5

    The perfect colours for a budding, colour-blind electrical worker.

  • @NillKitty
    @NillKitty 3 роки тому

    What was that other red wire in the garden that looks like you previously had hooked up to the earth electrode?

    • @jwflame
      @jwflame  3 роки тому

      The red wire is connected to one of the two temporary test electrodes, the other one is yellow.

  • @gd-bq7em
    @gd-bq7em 4 роки тому

    Hi john in the on site guide it says you can use 2.5mm to the earth rod is this because the pefc is usally so low like between 2 and 10 amps

    • @jwflame
      @jwflame  4 роки тому +1

      Yes, even with a 50 ohms rod, current would be 230/50 = 4.6amps.
      However the wire will need mechanical protection at that size, such as steel conduit. Other minimum sizes in Table 54.1 in BS7671.

    • @gd-bq7em
      @gd-bq7em 4 роки тому +1

      @@jwflame so is best to always upgrade to 10mm or 16 mm

  • @nanogeekpro2
    @nanogeekpro2 4 роки тому +12

    Sorry John, I'm not watching anymore of this video until you jump around on that trampoline...

  • @davidhart4748
    @davidhart4748 4 роки тому

    Hello this looks the same as testing lightning protection , am I right ?

    • @seanpassant3174
      @seanpassant3174 4 роки тому

      Yes, pretty standard Fall of Potential (FoP) test as you would hope a lightning protection specialist would do, however too often these days they carry out a 'dead earth' test using the the LPS as a reference electrode, which is not as accurate.

  • @hoglundh
    @hoglundh 4 роки тому +1

    Green grass in December? I'm waiting for the trampoline video.

  • @Madness832
    @Madness832 4 роки тому

    The hedges & grass are still green, but you can see his breath (beginning).

  • @michaelagnew7825
    @michaelagnew7825 4 роки тому

    On a TT earthing system, should N and E be linked at consumer board?

    • @jwflame
      @jwflame  4 роки тому +1

      No, not permitted on TT or any other arrangement.

    • @michaelagnew7825
      @michaelagnew7825 4 роки тому

      @@jwflame thanks JW, a so called "engineer" told me to link N to E bus bar as living in Thailand use a TT system or a PME?, I didnt as it sounded very ODD

    • @jwflame
      @jwflame  4 роки тому +1

      Other countries have various arrangements for earthing, but it's not permitted in the UK. Even where allowed, linking N&E wouldn't be a TT system.

    • @30mAkills
      @30mAkills 5 місяців тому

      I am from India where TT earthing system is followed.
      Reason for not linking n and e:
      Imagine the service has floating neutral fault. The consumer doesn't notice this as the return path is now 100 per cent via linked earth. OK fine.
      One bad day the earth lead got snapped (may be due to corroded joint or mechanical damage).
      Now what will happen? As both return paths are open, all metallic parts (switch boxes, conduit pipes, appliance bodies etc) of the service will get energized thru the earth terminals. The appliances will not work as there is no return path. In this condition if you touch the metal parts, you become the return path and get electrocuted.
      Bonus point: RCCB is must for TT earthing system in order to protect us from leakage currents. Mcb or fuse is not intended to protect us. These work during long duration over loads and shorts for fire protection of wiring and property.

  • @KevinCoop1
    @KevinCoop1 4 роки тому

    John, Kevin from across the pond. Ground rods are poor electrodes. Here in US if a rod is your only choice it must be 25 ohms or less for a single rod per NEC. If not add a second rod and you are done. I have a question, at 0:55 you said that if the earth ground rod was not connected to the consumer unit it would be dangerous. Do you not connect to other electrodes normally? And another question, what is the perceived danger if there is not an earth ground? Respectfully, Kevin

    • @KevinCoop1
      @KevinCoop1 4 роки тому

      R. D. And that is my question. Explain the dangerous condition.

    • @KevinCoop1
      @KevinCoop1 4 роки тому

      R. D. Your explanation is what about 99% of people think, but is not exactly correct. The purpose for Earth connections is for lightning, surges, and a 0 voltage reference point. It has pretty much no affect on the part of the system you describe. If live shorts to earth at an appliance in a residence, the electrical path is back to the consumer unit, to neutral, out to the utility transformer, through the transformer, back to the consumer unit, to the breaker and trips it. Thousands of amps. Very few amps go to the earth rod, which already happens before the short circuit existed. Electricity flows only in closed circuits and proportioned across all paths by the resistance. Respectfully, Kevin

    • @johnalexander2349
      @johnalexander2349 4 роки тому

      Any more than 30mA difference between L and N, and the ELCB trips. Way before N is bonded to E.

    • @KevinCoop1
      @KevinCoop1 4 роки тому

      R. D. Also, in US residential we have single phase that is 240 volts with a center tap neutral that is grounded. So 120 volts to ground. The 180 degrees is only because of the way an Oscope works. If you disagree with anything, m willing to discuss. Respectfully, Kevin

    • @jwflame
      @jwflame  4 роки тому

      UK consumer units do not have any connection between neutral and earth.
      With a TT system, the electrode is the only earth connection.
      Other types of installation (TN-S and TN-C-S) have an earth connection provided from the electrical supply, and although it's possible to install your own supplementary earth electrode as well, that is rarely done as it's not required and wouldn't achieve very much even if it was.

  • @wilbertbirdner1303
    @wilbertbirdner1303 4 роки тому

    I hope you don't let David Savery borrow your trampoline.

  • @laurencedarby9042
    @laurencedarby9042 4 роки тому

    Can you use a normal multimeter for this test?

    • @jwflame
      @jwflame  4 роки тому

      No, current/voltage output is too low and it's DC - the tester in this video and others normally output AC.

    • @millomweb
      @millomweb 4 роки тому

      @@jwflame I disagree. I fairly disagree wrt insulation testing BUT it is valid for that. For conduction testing a normal MM should be fine. The important bits are the test electrodes inserted into the ground.

    • @Tangobaldy
      @Tangobaldy 4 роки тому

      Po
      king finger in ground to detect faults works fine. I'm a m sure that method is on page 40

    • @millomweb
      @millomweb 4 роки тому

      @@r.h.8754 I'll maybe have a play this afternoon.

    • @millomweb
      @millomweb 4 роки тому

      @@r.h.8754 My next question - anyone got a clue as to what metal my earth rod's made from ? It's sort of lead-coloured but much harder.

  • @anelectrician
    @anelectrician 4 роки тому

    Can someone send me a link where this dude smiles
    You know 😁 Suma Dat !
    Dam !

  •  4 роки тому

    Like car mot's only guaranteed for the day it was done. If the water table drops and the garden dries out the earth rod could make poor contact.

    • @millomweb
      @millomweb 4 роки тому

      All very mysterious really - since E is connected to N. Just a case of using an RCD to detect _unauthorised_ leaks !

    • @millomweb
      @millomweb 4 роки тому

      @@r.h.8754 Why not though ?

    • @millomweb
      @millomweb 4 роки тому

      @@r.h.8754 Thanks for info re permission and extra earthing arrangements for N. Totally agree on your points re N failure risks.
      Defective cherry picker. A burst hose should disable the machine, not let it drop. For that reason, they are power up and power down. (Unlike forklifts that use gravity to lower the forks.)
      Manual lowering systems can use gravity but to operate, a normal operation safety system needs to be bypassed and that function is usually spring-loaded so requires person in attendance at all times holding the bypass valve open.

  • @Drew-Dastardly
    @Drew-Dastardly 4 роки тому

    I wonder if you could look into the old WW1 trench telephones using earth current signalling? Bayonets spiked into the ground and field telephones. I can understand RF, but I don't understand mud.
    Also, I stopped betting on the horses after Dark Ivy died at the ludicrous Becher's Brook, but it seems horses can be killed just in the paddock by electricity in the ground www.express.co.uk/sport/horseracing/229623/Accidental-electrocution-blamed

    • @Inkling777
      @Inkling777 Рік тому

      Those WWI trench telephones with an earth return had a major downside. The Germans could sneak into no man's land, plant two ground rods, and sneak back with a cable to each. Often there was enough voltage induced between the two rods to give them a tap on that phone.

  • @ohnoitisnt
    @ohnoitisnt 4 роки тому +2

    I can tell youre round a mates house. Cold sunday morning, freshly hungover... :P

  • @leeenglish4363
    @leeenglish4363 4 роки тому

    Remember people always pee on your rod

  • @johnclarke2997
    @johnclarke2997 4 роки тому +1

    Old electricians trick to get the earth loop impedance to the required level is to dump a bucket of water on the electrode and then put the wet electrode readings down on the certificate.

    • @jwflame
      @jwflame  4 роки тому +9

      That certainly reduces the impedance - but makes any test result totally meaningless.

    • @giz177
      @giz177 4 роки тому

      pee on it

    • @millomweb
      @millomweb 4 роки тому +1

      Reroute a downspout into the earth rod chamber & use as a soakaway ;)

    • @SillyPutty3700
      @SillyPutty3700 4 роки тому

      mix 5 pounds of salt in warm water slowly pour it in around the electrode. That will give you a pretty decent reading.

    • @martinwinfield2935
      @martinwinfield2935 4 роки тому

      Not if there is an earth fault at the time, you wont do it again.

  • @jaycee1980
    @jaycee1980 4 роки тому

    Now the question we all want an answer to... does JW use the trampoline ? :)

    • @trinityadam
      @trinityadam 3 роки тому

      Ha. Can you Imagine J.W On the Trampoline ? Bouncing up and Down haha Doing Twists and Turns and even Summer Salts ha ha ha.... He can connect his Earth Electrode to the Trampoline Body frame... ha ha ha