- BEAM DEATAILS , REINFORCEMENTS, TOP BARS AND BOTTOM BARS FOR REINFORCED CONCRETE BEAM.
This video is NOT sponsored. Some product links are affiliate links which means if you buy something we'll receive a small commission.
BUILDMATE: invol.co/cl5y7rd
Buildmate Online Depot
Welcome ka dito Ka-BUILDMATE! 👋
🚧Your One Stop Hardware Shop is always here
with the most complete home & living needs.
Be updated with our Special offers because every day
is Guaranteed LOWEST PRICE with us 🎉
✨DAILY VOUCHERS GIVEAWAY with just one click
in our ✅FEED Section & Chat button.
plus our Special 🚛 FREE SHIPPING deals
What are you waiting for?
Follow us and Get a Voucher now!
Home improvement design (Art Design PH): invol.co/cl5lx7p
Online Shopping Platform (LAZADA PH):invol.co/cl5lx98
Shop Online Specialized in hard to find items (Galleon PH): invol.co/cl5lxab
The Ultimate online shopping Experience (Ubuy PH): invol.co/cl5lxdb - Навчання та стиль
Hey guys please Consult Civil/Structural Engineer. Rule of thumb is dumb things of the past construction of any structure is serious business if mistake occur occupant will result to injury and worst death.
Share ko lang din po, na yung b (base) must not be equal or less than 0.4d (depth) = meaning if yung 'd' ng beam nyo is 0.5m, dapat hindi aabot or bababa yung base nyo ng 0.2m. > which is yung gamit ni sir na > factors for computing 'b' na 1.5, 1.4, at 1.3 is Safe Ratio for Beam Dimensions. NICE.
Good day sir..im 38 yrs old..my experience konte sa construction..plano ko sana mag enroll bilang civil engineer..salamat sa mga video nio..talagang nakakatulong
Asko ko sir kung Lic. Civil Engineer kayo or Architect kasi concern lang ako sa min. Na bakal na sinasabi nyo sir. Isa akong structural Engineer as per code ang min na bakal ay 16mm dia hindi 12mm dia. 5mtrs pa naman yang sinasabi mo na haba ng beam. Ok lang mag bigay ng idea or information pero pag hindi sure sir minsan kailangan din basahin uli ang code paka kasi naka ligtaan mo lang.
pwede yan sa 3m span thumb rule pero sa 5m span pwede rin basta sa roof lang ng garage at walang pupuntang mga tao or live loads mo lang siguro pusa.
"experience is the only source of knowledge"..... Hnd lahat ng bagay ay nasa libro...
@@noobslayer2441 Hindi lahat ng bagay nasa libro tama. Pero akala mo ba hinulaan lang yung mga nilagay sa libro? Base yun sa mga tests and experiences na sinasabi mo
Nakalimutan lang siguro magbasa ni kuya ng code
Ang galing po ninyo sir mag explain. Kahit kumplikado ang topic, madali niyong napapaliwanag nang maayos. Dami ko pong natutunan. Salamat sir
For ROT of beams kung residential dapat 3m lng ang distance between columns plus 1/3 of the total lenght for cantiliver,para siguradong safe.mas mahaba kasi ang lenght ng beam,mas lumalapad ang size ng biga,at mas lumalaki din ang size ng poste.mas maigse ang pagitan ng poste mas safe sa biga,the longer the span of a beam needs more extra bars.
Kahit papaano ok na sana ang cross section ng biga pero pagdating ng bakal sa tension area ay 2-12 at 2-16 medyo compromised yata lalo na ang span mo ay 5m.
Thank u so many much engineer, I learnt a lot from ur vlog
Ang aking rule of thumb sa size ng beam is multiply the length by 0.09. Ito ang depth ng beam. 3 m L depth is .27. 4 mL is .36m
Excellent tutorial hindi ka suplado or mayabang ang dating pang masa ang explanation mo at malinaw kahit student maeencourage manood at makinig maraming salamat po more power keep ssfe po sir ingat po sa covid god bless po
Thanks for watching
sa studyante baka magdalawang isip kung nakabasa na ng nscp,kay engr,rule of thumb at experience ang nakikita ko at simplified design.
galing mag explain naunawaan ko agad salamat sir
Thanks poh s information malaking tulong poh .god bless poh.
Engr.gab romano maraming salamat po sa pashare nyo sa amin ng inyong kaalaman.👍❤
maraming salamat po
ARCHITECT BAKA GAYAHIN NG MASON AT KARPINTERO NA ADVISE SA KANILA CONFIRN MUNA SA DIRECT ENGINEER ABOUT DOWEL SYSTEM PARA SA TENSILE STRENGTH
Sir request lang po paturo kame pagawa ng structural analysis sa bldg permit ung basic lang
Very Informative po ser.
👍👍👍
Ang galing nyo Po mag explain sir. Salamat Ang Dami ko Po na tutunan sa Inyo. ❤❤❤ Good bless po
Maramng salamat po sir very imformative
Request naman po..ung second floor gagwing 3rd floor na may roof deck? Thnks
New subscriber here thank you for your detailed videos
Ayoz!!Sir..may idea napo ako..tnx
Thank you bro.
Sir nasa bundok kmi sa Rizal yon gumagawa sa amin yon (FTB) biga sa pundasyon parang hagdanan style
Sir, request po sa solid slab.
Biga namin 30x40 L/3 meron syang extra bar n 3 pcs haligi sa haligi ung guitna 2 malalaking bakal n nk hook. bale 4 n bakal n sa baba.
Thats good po. Thanks for watching
so clear ng pag paka explain .
kung nakikinig ka lamang sa guro mo sa college ay ganoon din yan.
Thank you po sir for teaching us! More power po
Sir 4x4 m 7 Ang poste pero
Kalahate git na dereyso ang beaming 2m at SA gilid dereyso pwedi poyan. Taming Lang po
Thank you very much Engr Gab... very helpful ang mga Rules of Thumb, Factors of Safety, yung mga bunga ng experience sa construction... I appreciated your video very much... lalo sa Cost Estimates ng project... salamat talaga!
Thanks and have a great day
Engr isa ako sa subscriber mo at sumosubaybay sa mga vlog mo. Kaylangan ko ng advice mo engr. May plano ako magpatau ng bahay 5x6 2story na tubular at phenolic ang sahig 9poste may isa sa gitna 2.5 meters lang pag itan ng bawat poste. Pwedi bang gamitin kng bakal sa poste ay 6na 12mm? At pwedi ko bang gamitin sa beam ang 12mm pls..
napaka gandang lesson.....bigs thanks
Thank you rin po for supporting this channel sir
may napanood ako na video na naka bend ang bakal pero di ko maintindihan kala ko design lang . pero sa video n ito gets ko na. maraming salamat Sir share ko ito .
Please do share and thanks for watching po.
Have a nice day
Free Learning on UA-cam. Thanks for sharing.
Thanks for watching sir and have a great day.
hindi po lahat nang engineer ay maganda ang plano po at matibay may mga engineer din na marunong sa magic work pero kulang ang quality nang trabaho nila kaya humanap ka nang mapag katiwalaan talaga
Sir gud day... sir puede ba butasan ung column footing o poste para magdugtong ng connecting beam sa panibagong poste
Tnx Sir very informative ginagawa nyo more power
thanks for watching sir and have a great day.
Thank u for sharing po. Lagi ako ngnonood ng video nyo. Tanong ko po sana kung ung 5m na layo ng poste. Kung mag oover hang pa po xa pwede paba at ilang meters po pwedeng iover hang?
Thank you po engr,,,
Salamat Po Ng inyong binahaging karagdagsn naming kAalaman engr..godbless Po sir
Maraming salamat po, have a great day
Engr.gabs tnks sa info.
Thanks for watching
Galing mo sir Gab
thanks for watching
Very well explained. Thank you.
You are welcome! Po
Ganda ng paliwanag mo enginer, naintindihan ko ng hosto, salamat sa paliwanag sir,,,
Salamat din po
Sir sana po sa susunod na vedeo kung papano po naman iyong mga reinforcement sa slab at ano po iyong single wire mess at double wire mess at papano e apply salamat po boss Idol ang galing mong mag explain malinaw
ok po , salamat po sa pagtangkilik.
Thanks for this Bro.. Very informative
Salamat din bro, I also like ur channel and keep growing sir
Very imformative...👍👍👍👍👍
Thanks a lot po sir
Very informative.
Glad it was helpful! thanks for watching
Thanks engr.may natutuhan na Naman Ang asawa ko.simpleng contractor lang kasi siya.
Have a great day po
Napaka basic po sir, ang Dali pong intindihin. Salamat ng marami
salamat po and have a nice day
Hello Sir..ung measurements b n ginamit dito sa dept and width ng biga is concrete finish or size ng stirrups?
Very informative yung vlog nyo sr, more power to you po, ask ko lng po, kc yung size ng poste for 2 storey is 200mmX300mm pwede po ba na gawin ko na size ng beam is 200mmX300mm rin po? para magkaparehas sya nang laki but yung mga size ng steelbar po ay standard nmn po..medyo malaki kc yung 10inch X 16inch na beam po. Thanks in advance po
Engr. Gabs very helpful and interesting presentation. I would like to add only the importance of proper Anchorage of steel embedded inside the columns to develop the stresses.
marami pong salamat.
Nice content sir. Very helpful po.
Thanks for watching
galing mo magexplain. new subscriber here.
maraming salamat po sa pagtangkilik.
Ty engr. Romano it helps a lot
salamat po sa panonood
Very good content sir..
salamat din po sa pagtangkilik sir
Tnx very educational
thanks and have a nice day sir
Sir nag subsribe ako dahil maganda ang poliwanag mo step by step at mga materyales n gagamitin. 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏
salamat po sa pagtangkilik sir
Engener pwedi rin po ba mag double beam
Salamat ser😇
Welcome po
Engr. Gud eve. Para sa unsupported na 5m na lenght ng biga . 20x30cm 4-16mm continues, 2-16mm extra bars. Pwede na po ba sa second floor na light materials lang na tubular at phenolic ?
Salamat sir sa knowledge
welcome po
eng. ano po ang formula sa pag compute ng labor cost ng bakal per tones
Pwedi po ba nka hanger ang crank bar s top....pls answer me..thanks po..
Very informative vids
salamat po
Gdmorng, sir gab, tanung ko lang po kung magkanu Ang kuntrata ng labor and material per square meter po
THANK YOU PO
sir request for planted column design sa 2nd floor
Sir gud eve po kung Ang Gawin kung ilan Yung bakal SA itaas Yun na rin bakal SA ibaba di Po b mas ok
Hello po possible po ba ang 15ft na poste bago mag beaming?
Thank you so much po engineer
Welcome po
Sir 4m ang layo ng poste ano bakal pwede gamitin. Sa beam
Engeineer pwde n po grade 33 n bakal sa bungalow house 7x7 meter?sana po masagot,,solid subscriber,,salamat po
Concrete instead of cement ang magcacarry ng compression.
Maraming salamat po..
thanks po sir and have a nice day
Thank u engr
Sir ang 2 storey house nilalagyan pa ba ng roof beam?
Palagay ko po mas easier po macompute yong d=L/12 which is in m convert na lng po sa mm…
Engr. GABS tanong ko lang po pwede ko po ba pagawaan pa nng plano yung renovation ng apartment style subdivion po e2 sa cavite balak ko po slab na yung 2nd floor salamat po
A good thing to know how to get the ratio of the cross-section of the typical beam design using its length.
Base on my experience, the structural engineers usually allow 1 to 2-50mm 10mm rebar stirrups along with the end support of the beam before allows 4" to 6" spacing of the first quarter of the length then rest 8" toward the center. Another thing, the Structural Code (NSCP) allows only a minimum of 16mm rebar reinforcement. Lower than 16mm rebars like 12mm and 10mm are prohibited to use. Probably because of the seismic loads I think. Anyway, thanks for the lesson. =)
Medyo lakas lakas an mo ang boses kasi sa mga mHihina ang mga pandinig konting lakas at ayos ka na.
Kapag residential lang na maliliit, hindi na ginagamit ang NSCP na yan. Kinukuha na lang lagi ang minimum... Bahay ko nga 2 flrs pa 10mm lang ang lahat ng bakal at 9mm mga anillo... Inabutan na nung malakas na lindol dati, buo pa... Sa building siguro magcode ka o sa mga mansion na bahay, sa maliliit, hindi na, kaekekan lang yan...
@@ryanmedrina9411 sir sana masagot mopo ako sa 50sqm may 6pcs na poste 4pcs 12mm at 2pcs 10mm tapos 10mm din anilyo, sa biga naman 12mm 4pcs tapos 9mm anilyo pwede napo ba?
@@ivanacejomotorattv7934 Hindi ka nya sinagot ako nalang, since na maliit ang area mo which is 50 sqm lng mas mainam lahat ng 6 columns vertical bars 12mm muna lahat nka standard kna nyan, tapos stirrups or anilyo mo kung gusto maka tipid gamitan mo ng 10mm spacing 20cm pero ung neck column mo mula ibabaw ng footing start ka ng 5cm spacing ang sunod na anilyo gawin mong 10cm spacing apat na pirasong anilyo pataas na tig 10cm ang spacing the rest 20 cm na hangang taas, slmat
Eto tanong ko e kung ang common ginagawa sa beam ay d10 spaced na 1 to 2-50mm, 100mm hangang sa first quarter ng beam and rest 200mm. Paano naman sa column? May idea po ba kayo? L/4 din ba limit sa spacing ng 50mm to 100mm or L/3 o may ibang limit length? Para malaman sana na sakto ang design na hindi magover/under reinforced ang column at beam.
Maraming salamat po sir sa kaalaman.. nagsubscribe napo ako maganda po pagpapaliwanag nyo..salamat po ult
Thank you for watching
salamat sir
Welcome po
ang mga ganito idea ay para sa mga malalaki building.hindi ito na apply sa mga bongalow type na bahay lng.or kahit sa mga dalawa palapag.
Hello sir, pwede ba magkabit/maglagay ng beam sa poste mismo para sa porch. Height ng column na kakabitan ay 3.2m then ang ikakabit na Beam ay para lang sa height na 2.5m na taas ng Porch(slab ang roof ng Porch). salamat
Sir gabs,khit anong haba ba ng beam L/4 ang sukat at lhat ba klangan my midspan? Tnx
Nice one boss
salamat po
Thnks po.
Thank you bro! I learned alot from you 2day. Mhalaga tlga yung tinuro mo ngayon kasi nagkaroon ng knowledge sa beam construction. Ty!
salamat po sa pagtangkilik
Good day sir,pwede po ba magtanong po sa inyo. Paano po magiging bakal if ever ang beam schedule is left support 3-2 ,mid support 2-3, right support 3-2 sana po mapansin nyo po salamat po
Sir ask ko lang halimbawa na kuha mona nag D & W ng beam halimbawa 10-12inch yan naba ang size ng anilyo o yang 10-12inch na sukat kasama na ang cemento tnx
hello po.. magtatanong lang po kung ok lang ba ang magtiktik ng poste para makapaglagay mg floor level tie beam kapag hindi nkapag abang ng bakal sa poste?10x10 po size mg poste.. mga 2 incges po ang klamgan yiktikin para lumabas ang bakal sa poste
Sir Pwede po bang pareparehong 4 sa ilalim at ibabaw?
Thanks for the info sir.. tanong ko lng po.. 6x6 m po pagawa ko 2-storey po.. 3 m po pagitan ng poste pwede na po ba diretso po bakal.. ano po standard na bakal gamitin sa biga... thanks po..
Hi sir, tanong ko lang po halimbawa iba-iba ang distance ng mga poste like may 3meters meron din 4meters, ok lng ba iba2x size ng beam based don sa computation ng 3m at 4m? Or mas ok na e uniform lng lahat ng mga bega based don sa pinaka mataas na haba ng poste? Hehehe thank you po sa sagot. Amen! 😊
Sir kapag 6meters po ang haba ng beam ilang bakal po ang gagamitin at laki ng bakal?
Pno po mg compute ng l over 4 s stirup
gud pm sir.sa poste po ng bahay at beam anu po ung magandang sukat or size 8meter x 8meter po ung kabuoan ng bahay?? salamat po sir
Salamat po dami kong nattunan 🥳
Sana po sa ssunod magkaroon kayo about sa CANTILEVER BEAM
SALAMAT PO 😇
Yes po I will upload cantilever beam soon.
Thanks for watching and have a nice day.
Engr.pwede ba magtusok ng bakal sa beam para kakapitan ng traces at mag welding,palalagyan ko kasi ng support traces sa ilalim ng slab
sir gab hinge ako idea 4x8 meters area pero secondfloor po cya anu po tama sukat ng poste sa slab at beam