Pentair EasyTouch Automation System Installation | Part 1

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • Swapping out a Intermatic load center for a New Pentair EasyTouch Load Center to fully automate the pool equipment.

КОМЕНТАРІ • 40

  • @martinrojas7595
    @martinrojas7595 3 роки тому +5

    Thank You for putting up these videos. I'm new to the trade so these videos are literal gems to me, much appreciated my brother!

  • @thompsonp86
    @thompsonp86 3 роки тому +2

    This was a very helpful video as I embark on having my own pool built, Thank you so much for taking the time and energy along with very skillfull camera work to document all of this. I hope my sub has half the knowledge you do.

  • @commandalorian8246
    @commandalorian8246 3 роки тому +2

    Putting in those hours!!!! See you tomorrow, looking forward to the next video.

  • @efrainzunigaswimmingpoolso9949

    Thank you so much for this informational video , I appreciate your time

  • @stevencorrera270
    @stevencorrera270 3 роки тому +5

    Just an FYI. Intelliflo pumps are suppose to be wired hot from and breaker and then controlled via the low voltage comm wire. Same with the system transformer. Should be wired from a breaker not through the filter pump relay.

    • @EliteSwimmingPoolsTV
      @EliteSwimmingPoolsTV  3 роки тому +4

      Have you watched all parts of this video series?
      This system was ultimately wired this way you are stating. Pump originally was not connected to a automation system.
      Check out and watch all the way through and you’ll see the correction we made.
      Thanks for watching and hope your a subscriber!

    • @stevencorrera270
      @stevencorrera270 3 роки тому +1

      @@EliteSwimmingPoolsTV no I had only watched part 1. Good video overall. Keep it going.

    • @EliteSwimmingPoolsTV
      @EliteSwimmingPoolsTV  3 роки тому

      Watch the other parts it gets good. Thanks for watching part 1 and hope your a subscriber.

    • @courtneyjagoda6368
      @courtneyjagoda6368 3 роки тому +1

      Doesn't matter pentair is trash.

    • @EliteSwimmingPoolsTV
      @EliteSwimmingPoolsTV  3 роки тому +2

      To each is own. I install what is required and recommended for the “client”. I do have my preference but that choice is for my pool. Thanks for watching

  • @javierpareja598
    @javierpareja598 3 роки тому +1

    Great video

  • @kyleboyer8542
    @kyleboyer8542 2 роки тому

    When I saw his water hose, I thought that was all conduit and I was like “umm… wtf?” Lol

  • @joejoe6949
    @joejoe6949 6 місяців тому

    So you can put the pump on com port j3 and or j2 ?

  • @jimbobbrowning35
    @jimbobbrowning35 3 роки тому

    What part numbers did you use in this installation? Really like this series, and look forward to the rest of your videos.

  • @AricRider
    @AricRider 3 роки тому +1

    Can you confirm that the Heat Pump doesn't get wired into any of the AUX?

    • @EliteSwimmingPoolsTV
      @EliteSwimmingPoolsTV  3 роки тому

      No it does not. It received its power from a breaker, and then receives signal and wired to the main board. Not to AUX

  • @joelthompson4801
    @joelthompson4801 Рік тому +1

    What’s the gauge wire going into the Subpanel?

  • @johnlolofishing
    @johnlolofishing 3 роки тому

    Lame question but I work outside all day. What brand are your shirts?

  • @SpraguesTackle
    @SpraguesTackle 3 роки тому

    how big is the main feed to the sub panel 60 or 100amp?

  • @JonathanLGN
    @JonathanLGN 3 роки тому +1

    Did you switch away from Jandy?

    • @EliteSwimmingPoolsTV
      @EliteSwimmingPoolsTV  3 роки тому +2

      Hey Jon, no I haven’t made a switch. I sell and install the brands that best suits the client. Even though I am bias to Jandy products, I look at what the client currently has and needs are and sell them on the right product for their pool. This clients equipment was totally Pentair. No reason to sell and install a Jandy automation system. Also I want to ensure that all equipment communicates seamlessly with each other. If you notice this client had a stand alone ichlor salt system, if I would have installed a Jandy automation load center, the client wouldn’t be able to control the salt system through the app. Also I would have to continue to test the salt levels with strips and walk over to the cell each time for adjustments as would the client. The pump controls would also stay independent from the automation system and that wouldn’t be ideal for the client. Even though most brands can cross communicate with one another, some features and controllability are lost with using different brand automation systems, and to me it looks wired to have all one brand of equipments and one piece of equipment of another brand.

    • @JonathanLGN
      @JonathanLGN 3 роки тому +1

      @@EliteSwimmingPoolsTV Great man! Thanks for the great response!

    • @EliteSwimmingPoolsTV
      @EliteSwimmingPoolsTV  3 роки тому

      Always

  • @warren4042
    @warren4042 3 роки тому +1

    The music why? it sounds like waiting on Jandy to answer the phone Great info though

    • @EliteSwimmingPoolsTV
      @EliteSwimmingPoolsTV  2 роки тому

      I loved it. 😂

    • @kyleboyer8542
      @kyleboyer8542 2 роки тому +1

      Lmao I love that, I’ve spent enough time on the phone with zodiac about the MX8 being shit and trying to get warranty claims, that I know your pain Lmao

    • @EliteSwimmingPoolsTV
      @EliteSwimmingPoolsTV  2 роки тому

      Instead of calling Jandy tech support, find out who is your regional rep and get to know them well. They can make warranty claim decisions and approvals much quicker than tech support can and often times send you the parts direct to you, as long as you are a legit pool company authorized to sell their products.

  • @harryhhu
    @harryhhu Рік тому

    Great video, just the background music is too loud, there is time we can't even hear the speak

  • @pah1of284
    @pah1of284 Рік тому +1

    Turn down the music and edit up the speaking parts