How to check Earthing is Proper or Not in Home

Поділитися
Вставка
  • Опубліковано 27 січ 2025

КОМЕНТАРІ • 60

  • @tamminalokeshkumar9899
    @tamminalokeshkumar9899 Рік тому +9

    Voice with valuable information ❤❤❤

  • @sanjitkumargurung-zm8zv
    @sanjitkumargurung-zm8zv 2 місяці тому +2

    Very beautiful knowledge sir

  • @kamolhengkiatisak1527
    @kamolhengkiatisak1527 Рік тому +2

    So clear and easy to understand. Have subscribed since last month when you talk about MCB, ECCB, MCBO etc which is so easy to understand.

  • @oscarwatcher99
    @oscarwatcher99 5 місяців тому +2

    What a great simple way to test your earth circuit. 😊😊😊

  • @meetr4u
    @meetr4u Рік тому +1

    Good explained.

  • @usrm-wm1osbr5v
    @usrm-wm1osbr5v 8 місяців тому +2

    Useful info video.

  • @dido1803
    @dido1803 Рік тому +1

    Great information!!!

  • @bharatbshetty
    @bharatbshetty 7 місяців тому +1

    Very informative. Thanks for sharing this

  • @ashishkulkarni6382
    @ashishkulkarni6382 Рік тому +1

    Very useful. Thanks

  • @fahadomar1503
    @fahadomar1503 3 місяці тому +1

    bro, you explained it in very good way. thanks

  • @bashiruosman473
    @bashiruosman473 Рік тому

    Good ❤

  • @anupyadav440
    @anupyadav440 29 днів тому +1

    High voltage breakdown tester testing methods plz

  • @ssennonojohnmary4406
    @ssennonojohnmary4406 Рік тому +6

    With the lamp method, I think when you connect a phase with earth ,you are creating an earth fault , and I think that lamp will just blow. Explain more!

  • @vinothkumarsrv9033
    @vinothkumarsrv9033 6 місяців тому

    Easy understanding

  • @shwewin5086
    @shwewin5086 3 місяці тому

    Tks very much.

  • @owolabiadeteye5919
    @owolabiadeteye5919 Рік тому +1

    Thanks so grateful for sharing this. Pls voltage of P-N and P-E are almost the same, at what point does neutral is connected to earth. Pls I need clarification. Thanks

  • @ambikapathi.m4140
    @ambikapathi.m4140 7 місяців тому

    Good

  • @seenivasanseenivasan6685
    @seenivasanseenivasan6685 Рік тому

    super

  • @zenebehagos3537
    @zenebehagos3537 Місяць тому

    Is this method applicable for industries and factories

  • @KamogaJunior
    @KamogaJunior 7 місяців тому

    Thanks very much

  • @Finalboss90
    @Finalboss90 4 місяці тому

    thank you man

  • @KamogaJunior
    @KamogaJunior 7 місяців тому

    Thanks 👍👍

  • @ashokkumargnanasekarnadar
    @ashokkumargnanasekarnadar Рік тому

    Thank you for the quick explanation. I saw your other video on using Capacitor for power factor correction. Which Capacitor is to be used and what is the MFD etc to check and buy for the installation? can you guide 🙏

    • @ashokkumargnanasekarnadar
      @ashokkumargnanasekarnadar Рік тому

      it's for a home with a single phase connection. I observe frequent fluctuations. Below 200 V is what sometimes it happens.

  • @gurukarthik_agri
    @gurukarthik_agri 2 місяці тому

    While checking neutral and earth if not getting any reading means? what's the reason?

  • @Ku5u
    @Ku5u 2 місяці тому +1

    hi, i have tested using the methods which you have shown and its all ok like you said but the voltage between neutral and earthing is 3 volts, i am getting shock from touching appliances like phone charger and the body of my computer
    can you explain why is that and how can i fix it?

    • @hardhitter39
      @hardhitter39 Місяць тому

      you have to do earthing in your home call a certified electrician and do the process they will install a aluminium rod

  • @otobrisejerry1437
    @otobrisejerry1437 6 місяців тому

    If we are not getting almost the same volt with neutral and line when checking the earth. Does it mean that the salt we have used for our earth rod is not ok or working well? What should we do about it?

  • @deivakumarkumar4857
    @deivakumarkumar4857 Рік тому

    How can we determine Earth wire and The Neutral wires?

  • @ShivamThakur-v3g
    @ShivamThakur-v3g 3 місяці тому

    How to correct it sir

  • @SupertigerDev
    @SupertigerDev 11 місяців тому

    Is it normal to have 40 ac voltage between earth and my monitor dc jack + or - ?

  • @lawrenceatkinson
    @lawrenceatkinson 9 місяців тому

    🎉

  • @alboeng
    @alboeng Місяць тому

    If I have battery bank which voltage is 117Vdc, what will voltage be measured between positive and building earthing terminal?

  • @danielteyehuago1633
    @danielteyehuago1633 Рік тому

    How do you bury a proper or effective

  • @geoma6413
    @geoma6413 3 місяці тому

    Between my earth and neutral are showing Zero volts in multimeter is that ok? cos i saw in some video that 0 volt is also not ok is that true ?? The rest Earth and phase , phase and neutral are all fine.

  • @anan_ahnaf
    @anan_ahnaf 3 місяці тому

    what if i use my device with line and earthing point, as line- neutral and line-earthing have the same voltage?

  • @bhagwanpandbhar3406
    @bhagwanpandbhar3406 3 місяці тому

    Ok thanks

  • @bensonogbe2040
    @bensonogbe2040 Рік тому

    What textbook (s) by an indian authors would you recommend for an electrician?

  • @brittojohn1844
    @brittojohn1844 Місяць тому

    pl tell me how to find out which wire is neutral and which one is earth in the absence of color code excluding test lamp method

    • @TusarRoy-fl4li
      @TusarRoy-fl4li 15 днів тому

      The top point will always be earthing, and to find out the bottom one, you will need a tester. Of the two below, the one where the tester light will light up will be positive , and the other will be neutral.

    • @brittojohn1844
      @brittojohn1844 15 днів тому

      @@TusarRoy-fl4li I know that Pl read my comment again I mean wire not socket . To test which wire is earth connect that wire with another one from earth point of the socket, go for continuity test or remove home earth connection and then test with a test lamp I checked using multimeter but it showed same value so I could not confirm which one is earth after heavy rain

  • @sushilkumarmahto-h5j
    @sushilkumarmahto-h5j 27 днів тому

    Sir n to p=212
    Earth to phase=232
    E to N=15
    What is problem in this

  • @michaelisongekwere1402
    @michaelisongekwere1402 4 місяці тому

    Our panel light chokes keep blowing up after a few minutes of switching on the light meanwhile other appliances are not affected what can we do to resolve this fault?

  • @arivalagan9943
    @arivalagan9943 Рік тому

    Please brother small question

  • @takasipattabhiramdora3811
    @takasipattabhiramdora3811 10 місяців тому

    Neural to phase and phase to earth is same,(230v)
    But neutral to earth getting Zero
    What is the reason sir?

  • @GoogleMP-un1yk
    @GoogleMP-un1yk 4 місяці тому

    Bhai switch off me bhi thoda thoda glow kar raha hai to kya kare?

  • @Milkteabooba
    @Milkteabooba 7 місяців тому

    red needle to neutral + black needle to earth
    my readings is 001 to 004.. what does that mean?

  • @Mighty-vx7kr
    @Mighty-vx7kr 7 місяців тому

    So in case there a fault or the earthing in our homes is not proper, how to we go about it thanks

    • @slotzmori9181
      @slotzmori9181 4 місяці тому

      Call an electrician.....
      CURRENT KILLS

  • @bongdzeerasmus2350
    @bongdzeerasmus2350 9 місяців тому

    Hello there. I tested the voltage between the live wire and the earth wire and it was give me above 400Volts.

    • @Fakafaaka
      @Fakafaaka 8 місяців тому

      is your house a power station?!😂😂
      just kidding

  • @sachinms2772
    @sachinms2772 10 місяців тому

    hiw to check it in a mechanical meter

  • @manuellastrollo2168
    @manuellastrollo2168 Рік тому

    neutral must have zero volts when other test prod is connected to earth cause earth & neutral is connected on same terminal.

  • @danielteyehuago1633
    @danielteyehuago1633 Рік тому

    This bring about my next question. How do you bury effect earth

  • @nabuumaprossie8421
    @nabuumaprossie8421 4 місяці тому

    I do not understand how do you know that neutral is not ok in ma room

  • @dadjoedrice1092
    @dadjoedrice1092 8 місяців тому

    What if the voltage gives 200v and the earth gives 298v

  • @AIHHerath-su7lg
    @AIHHerath-su7lg 13 днів тому

    That way gone trip off way so

  • @slotzmori9181
    @slotzmori9181 4 місяці тому +1

    So many stupid questions....if you don't understand then don't attempt to do it...
    CALL AN ELECTRICIAN...
    SAFETY IS PARAMOUNT

  • @robianhussein5298
    @robianhussein5298 Рік тому

    Good explained.