Wakime sir aapka vodeo se hvac team ko bahut sport milta hai sir mai bhi bahit kux silha hu sir !Sir agar chiller me koi parts kharab hogiya to use ham kaise find ot kare sir kish chijke or kaise please sir
Maixmum cheejo ka alarm aa jata hai display pe mere dost .. baaki kuch aor problem hoti hai to noise karne lagta hai chiller ya start hi nahi hoga .. wo apko khud se dekhna hoga saare components ko ... Sukriya
Maximum surge tab hota hai jab apka load ya high pressure jyada ho .. us condition me aap pahle cooling tower ka water level and fan condition check kare ... aor ye dekhe ki kitne ahu ya fcu chal rahe hai ... Ye check kare apko fault mil jayega
Mai residential field kam krtahu ya ahus or fcu units ni rehtey only cassette units rehtey so chiller 7.2 ya .3 deg pe surge krna chalu hojata or ishe chiller ko chalaye toh wo 6.5 per aake cut off leta or maximum surge low load pe hi karta hai , so thanks for the answer 😊👍
Sir I have requested you plz one question NRV valve used in chiller piping line in supply ya return line used NRV because interview questions asking me but I am given ans return line but not accepted interviewer
Ji ha bilkul ... Lekin agar samne vala poochle kaise shefty karega to .. aap bata sakte hai ki back water pressure ko impeller tak nahi aane deta hai 👍
Your way of explaining is very easy, we can understand easily...
Thank you very much for compliment 👍
Vowww sir excellent video NRV concept clear very easily style.❤
ji sukriya apka
Jis kisi ko bhi koi bhi interview HVAC field se deni ho to plz C4 chiller ki vedio dekh lo life me success ho jaaoge insallah
Bahoot sukriya ji apka 💐👍 my heart is very happy to see your comment 🤗
Bahut ache se samjhate ho bhai
Ji bahoot sukriya
Bhut easy way se samjhate hai app 👍👍👍👍
Bahot badhiya samjaya
thank you dost 👍
Thanks jankari dene ke liye sukriya
👍👍
Thank u so much sir aisi chhoti badi cheeze ka ubdate dete rahiye thank u
ji jarur 👍
Sir aapke jaisa interested video kisi bhi channel par nahi milta hai aapka sabhi video mai watch karta hu sir bahut hi interested videos banate hai ❤❤
thank you dost ....for loving and supporting 💐🙏
Superb Sir Ji
jii ...thank you 👍
Thnx guru ji 🙏
Explain is very well
Sukriya ✨
Thanks sir
Nice information sar ji jaise sar mceel laga de bhi ruk jayega na sar
Wakime sir aapka vodeo se hvac team ko bahut sport milta hai sir mai bhi bahit kux silha hu sir !Sir agar chiller me koi parts kharab hogiya to use ham kaise find ot kare sir kish chijke or kaise please sir
Maixmum cheejo ka alarm aa jata hai display pe mere dost .. baaki kuch aor problem hoti hai to noise karne lagta hai chiller ya start hi nahi hoga .. wo apko khud se dekhna hoga saare components ko ... Sukriya
Sir plz York chiller ke sabhi alarm aur safety per seperate video bnaye🙏
Sir plz put information according to Instrument.
Ji ok jaise hi time milega .. will make your vidio thank you 👍
Ye mera instagram id hai agar apko koi questions poochna hai to pooch sakte hai any time 👉 kgufran195
Bhai aap full HVAC daigam ke ek video banaiye jis me parmary pump and secondary pump dono show kijiye ga
Ji jaise hi time milega ham jarur add kar denge
❤
♥️
Sir conection nhi abhi tak nhi bataye h sir door switch ke aur demper aur limet swich ke conection btaiye please
160 TR ke chiller me kitne gas aayegi
❤️❤️❤️🌹🌹🌹🌹❤️❤️❤️
Sukriya
Sir NRN ko gate wall bhi to bol skte h
nahi bol sakte
gate valve ka work alag hai
nrv ka work alag hai
Sir, Can you explain this information in English
Sar ji lo section pressure बार-बार kyon aate rahata hai
Gas ka pressure check kiya .. ??
Sir appsajhate ho yad rahta hai
bas aap log samjh jaate hai ....hamari mehnat vasool ho jati hai 🤗🤗
Jab chiller surg kare toh usse off karna chahiye ya jab tak cut off ho tab tak running me rehna chahiye.
Maximum surge tab hota hai jab apka load ya high pressure jyada ho .. us condition me aap pahle cooling tower ka water level and fan condition check kare ... aor ye dekhe ki kitne ahu ya fcu chal rahe hai ... Ye check kare apko fault mil jayega
Surge agar low load pe ho tab off karna chaiyee chiller ko .. aor agar high load pe surge hoga to apka fault check karna hoga ... 👍
Mai residential field kam krtahu ya ahus or fcu units ni rehtey only cassette units rehtey so chiller 7.2 ya .3 deg pe surge krna chalu hojata or ishe chiller ko chalaye toh wo 6.5 per aake cut off leta or maximum surge low load pe hi karta hai , so thanks for the answer 😊👍
Ji bilkul ।। But apke chiller pe shayed kam load hai jiske vajah se surge pe aa raha hai ।।। Agar aisa hai to aap apne chiller ko 75 % load pe chaliye
Or chiller pe kuch effect padhega kya ? While surge
Sir I have requested you plz one question NRV valve used in chiller piping line in supply ya return line used NRV because interview questions asking me but I am given ans return line but not accepted interviewer
Pump ke outlet line use hota hai aor chiller ke Inlet line me use hota hai mere dost ... 👍
@@c4chiller9984 🤗🤩yes
Aese bol sakte h ki nrv pump ka sefty h...
Ji ha bilkul ... Lekin agar samne vala poochle kaise shefty karega to .. aap bata sakte hai ki back water pressure ko impeller tak nahi aane deta hai 👍
@@c4chiller9984 👍
Gufran bhai Instagram par reply nahi kr rahe , is everything alright?
Jitne TR ka chiller hoga utni hi has uske under aayegi
650 gram se 700 gram gas charge hoti hai 1 tr me
Hi my brother I'm mechanical engineer and I am fresher I did HVAC certificate course I need a job please help me
Ji ye mera instagram id hai aap ispe contact kariye 👉 kgufran195
NRV vs DPCV?
Kya questions hai apka ??
Sir ji plz mujay what's up num do
dost ye mera instagram id hai apko Jo poochna hai yaha pe pooch sakte hai ...id 👉 kgufran195