Bro you are too good , keep it up ...... Home Distribution box sy heavy koad ko separate kasay karay if agar ap small inverter laga rahay geun ( 1.2 --2.5 etc)is pr banaye video
Asif bhai isi tarah aik achi video banana, jis mey solar distribution box se main ghar aor rooms ke breaker tk supply kaisy karna hay, matlab solar DB aor ghar ka mc box kaisy connect karna hy, is se confusion dooor ho jaega
why cant we use 9 plates of 585w (just 1 more than 08 plates), keeping in mind that output load shouldnt cross 4kw. 9 x 45v = 405vdc that still is under range. The maximum out PV can produce is 5265 (which is only 265+ watts). Also 70% over all efficiency of enitre system with panels) . I am using 585w 06 plates and it only draws maximum PV watts 2.45Kw out of 3.5kw plates
bhai mera fronus ka inverter h . charging cso pr ki hui h wese sub mode h lekin din mein wapda breaker off krtay hn. plz guide kr dein k sha 6 bajay k baad jb wapda b on kr detay hn tb b batery drain hina shurru ho jati h 54 se 52 ya 51 pr a jati h phir jb maghrin mein solar khatm hota h tb charge honay lg prti battery . aesa q h .
OSO par kardain sirf solar say charge hoga Inverter best setting ki video dekh lain inshallah saray maslay solve hojaingye Inverex inverter setting Guide: ua-cam.com/video/1vaRcA0AqBI/v-deo.html
32 communication error hai Lithium battery ki wire disconnect Hoti Hai To Aata Hai Aur Agar Lithium battery Nahin Hai To fir battery ki setting sahi se Karen Inverex inverter setting Guide: ua-cam.com/video/1vaRcA0AqBI/v-deo.html
1. Why 20 amp dc breaker for 13 amp pv? It should be 15 amp. 2. Why 17 amp MACB when household Wapda give maximum 40 amp. It should be 40amp circuit breaker.
ماشاءاللہ عزوجل بہت زبردست انفارمیشن دی ہے لیکن بھائی جنہوں نے دیسی ہینڈ میڈ انورٹر لیے ہیں وہ کیسے سیٹنگ کریں۔ میرا 10kv کا انورٹر ہے اس پر 2کولر فین 1واٹر پمپ اور 5سیلنگ فین بیک وقت چل جاتے ہیں مگر دوسرا فریج جب بھی on کریں تو ٹرپ کر جاتا ہے جبکہ 1فریج اور پمپ ایک ساتھ چل جاتے ہیں مگر 2فریج اکٹھے نہیں چلتے
السلام علیکم۔۔۔۔ آپ نے 585 Jinko پینل کے 45 وولٹ کیلکولیٹ کئے ہیں جبکہ ڈیٹا شیٹ میں voc 51.1 volt اور ایمپیر 13.76 لکھے ہیں. میرے 5.6 kw انورٹر کے Max PV Array open circuit volt 450 Vdc ہیں ۔ آپ سے پوچھنا ہے کہ کیا میں Jinko 585 کے 10 پینل سیریز میں لگا سکتا ہوں. Wattage کے اعتبار سے 6000 واٹ کی PV انپٹ input دے سکتے ہیں. انورٹر ماڈل۔ solarmax Orion PV 6000
Voc jab hota jab koi load na ho, load anay kay bad volt 45 hojate hain, par phir bhi 10 panel 45 kay hisab say bhi nhi lagana chahiye 450 banayg, ap parallel series try karain agar max Ampere ziayada hain tu
Voc jab hota jab koi load na ho, load anay kay bad volt 45 hojate hain, par phir bhi 10 panel 45 kay hisab say bhi nhi lagana chahiye 450 banayg, ap parallel series try karain agar max Ampere ziayada hain tu
@@TechnicalAsif747 Inverter Isc Pv is 27A. If used parallel it will also reach to maximam. I think 9 panel option will be safe and better. What you suggest
بہترین. اللہ آپ کو جزائے خیر دے. آمین
Ameen
khush rhin love u
جزاک اللہ خیر
Jazakallah
Thanks a lot
Bro you are too good , keep it up ......
Home Distribution box sy heavy koad ko separate kasay karay if agar ap small inverter laga rahay geun ( 1.2 --2.5 etc)is pr banaye video
Inshallah
Asif bhai isi tarah aik achi video banana, jis mey solar distribution box se main ghar aor rooms ke breaker tk supply kaisy karna hay, matlab solar DB aor ghar ka mc box kaisy connect karna hy, is se confusion dooor ho jaega
MashaAllah, very informative video. 👍👍 Kindly do make a video on Its upper version inverter 6kw
As soon as possible
Inverter k error code ki bhi vedio banay thanks good work
Thanks for recommendation
Nice bhot achi videos
Thanks
good
Thanks
Please ye bhi bta den k Kia
Solar ya Battery Source k connection ko Breaker k ooper waley portion me input den ya ???
Assalamoalikum sir 20kw grow watt on grid ki wiring box ky sath zaror tayyar krin aur 10 kw grow waty ky lye bhi
Aoa, aap software konsa use karte ho...kindly reply kar den
Very good practically defined.
Lakin aap ne cables/wires ka nhi btaya kahan konsa or kitne mm ka wire use kerna hai
Will make video on that
@@TechnicalAsif747 brother pls breaker DB box may konse wire use honge bata den. Mje coming Saturday solar system install kerwana hai.
veyron2 4 kw pr 580 watts ke maximum kitny pannel install kr skty hen?
inverter ky sticker pat sub detail hr cheez ki bhi tayyar krin
Assalam Valecum Dear ap complete solar installation kartey hai. City Karachi
Please rply with details?
Mppt ky meaning bhi btain ky ye kya hota hi
Pv sa inverter tak 70 fit fasla hu tu Kitna mm ka DC wire istamal kare 4kw k Lia
سر اگر آپ سے کوئی یہ کورس سیکھنا چاہیے تو آپ سیکھا سکتے ہیں ؟؟
Aslam o alaikum bhai
Asif bhai inverex veryon 1.2 pey 1 ton inverter ac chala saktay hai?????
Nhi
2.5 inverter per kya kuch chala sakte hain pls
1 ton Inverter AC, 1 inverter fridge, 4 fans, 4 lights
Inverex veyron II 2.5kw can run: ua-cam.com/video/CAIzWwcHybM/v-deo.html
why cant we use 9 plates of 585w (just 1 more than 08 plates), keeping in mind that output load shouldnt cross 4kw. 9 x 45v = 405vdc that still is under range. The maximum out PV can produce is 5265 (which is only 265+ watts). Also 70% over all efficiency of enitre system with panels) . I am using 585w 06 plates and it only draws maximum PV watts 2.45Kw out of 3.5kw plates
سلام
وعلیکم اسلام
I solar app ka masala hal ho gaya hai ya nahi please sir reply me
Confirm Nahin lekin Kafi Logon Ka Chalna shuru ho gaya hai aap bhi try Karen
bhai mera fronus ka inverter h . charging cso pr ki hui h wese sub mode h lekin din mein wapda breaker off krtay hn. plz guide kr dein k sha 6 bajay k baad jb wapda b on kr detay hn tb b batery drain hina shurru ho jati h 54 se 52 ya 51 pr a jati h phir jb maghrin mein solar khatm hota h tb charge honay lg prti battery . aesa q h .
OSO par kardain sirf solar say charge hoga
Inverter best setting ki video dekh lain inshallah saray maslay solve hojaingye
Inverex inverter setting Guide: ua-cam.com/video/1vaRcA0AqBI/v-deo.html
apni video ka voume thora oncha rkhin aur proper treeqy sy new comer ko bhi smjhain
Same inverter h error 32 de rha h any solution?
32 communication error hai
Lithium battery ki wire disconnect Hoti Hai To Aata Hai
Aur Agar Lithium battery Nahin Hai To fir battery ki setting sahi se Karen
Inverex inverter setting Guide: ua-cam.com/video/1vaRcA0AqBI/v-deo.html
1. Why 20 amp dc breaker for 13 amp pv? It should be 15 amp. 2. Why 17 amp MACB when household Wapda give maximum 40 amp. It should be 40amp circuit breaker.
ماشاءاللہ عزوجل بہت زبردست انفارمیشن دی ہے لیکن بھائی جنہوں نے دیسی ہینڈ میڈ انورٹر لیے ہیں وہ کیسے سیٹنگ کریں۔ میرا 10kv کا انورٹر ہے اس پر 2کولر فین 1واٹر پمپ اور 5سیلنگ فین بیک وقت چل جاتے ہیں مگر دوسرا فریج جب بھی on کریں تو ٹرپ کر جاتا ہے جبکہ 1فریج اور پمپ ایک ساتھ چل جاتے ہیں مگر 2فریج اکٹھے نہیں چلتے
Jee handmade inverter ka yeh issue hai ap use hi vendor say karwa saktay hain setting agar wo karat tu
Jee handmade inverter ka yeh issue hai ap use hi vendor say karwa saktay hain setting agar wo karay tu
السلام علیکم۔۔۔۔ آپ نے 585 Jinko پینل کے 45 وولٹ کیلکولیٹ کئے ہیں جبکہ ڈیٹا شیٹ میں voc 51.1 volt اور ایمپیر 13.76 لکھے ہیں. میرے 5.6 kw انورٹر کے Max PV Array open circuit volt 450 Vdc ہیں ۔ آپ سے پوچھنا ہے کہ کیا میں Jinko 585 کے 10 پینل سیریز میں لگا سکتا ہوں. Wattage کے اعتبار سے 6000 واٹ کی PV انپٹ input دے سکتے ہیں. انورٹر ماڈل۔ solarmax Orion PV 6000
Voc jab hota jab koi load na ho, load anay kay bad volt 45 hojate hain, par phir bhi 10 panel 45 kay hisab say bhi nhi lagana chahiye 450 banayg, ap parallel series try karain agar max Ampere ziayada hain tu
Voc jab hota jab koi load na ho, load anay kay bad volt 45 hojate hain, par phir bhi 10 panel 45 kay hisab say bhi nhi lagana chahiye 450 banayg, ap parallel series try karain agar max Ampere ziayada hain tu
Ya sirf 9 panel Laga lain
@@TechnicalAsif747 Inverter Isc Pv is 27A. If used parallel it will also reach to maximam. I think 9 panel option will be safe and better. What you suggest
Wapda input breaker should be 27 A?
Inverter's input limit is 27A, so yes close to 27A