Hikvision Intercom DS-KD8003 IME1 Lock wiring diagram. Electric &Magnetic lock & 2 lock connection

Поділитися
Вставка
  • Опубліковано 21 лип 2024
  • Hikvision Intercom DS-KD8003 IME1 Lock wiring diagram. Electric &Magnetic lock & 2 lock connection.
    0:00 Intro
    00:11 Electric Lock Wiring Diagram
    05 :10 Magnetic Lock Wiring Diagram
    09:25 Dual Lock Wiring Diagram
    11:18 Enable Door 2 via Batch Tool
  • Наука та технологія

КОМЕНТАРІ • 89

  • @elimgoz
    @elimgoz 2 роки тому +7

    Great guide.
    Much easier to understand than the official manual, thanks.

  • @kennyvandewiele9883
    @kennyvandewiele9883 Місяць тому +1

    Do i need to setup this or enable

  • @aliwahabi6876
    @aliwahabi6876 11 місяців тому +1

    Thank you so much, you have given me a great solution. so much helpful and very well explained.

  • @michaelrodriguez1244
    @michaelrodriguez1244 Рік тому +1

    Muchas Gracias. Many Thanks :)

  • @S7EVE_P
    @S7EVE_P 11 місяців тому +2

    Thanks for this, really helpful

  • @JaimeRamirez-zr3oh
    @JaimeRamirez-zr3oh 9 місяців тому +2

    Para una distancia de 80 mts que aconsejan
    Gracias por la información

  • @kaluischannel173
    @kaluischannel173 2 роки тому +1

    your video is a big help for me.

  • @user-re5yl4sj4f
    @user-re5yl4sj4f Рік тому +1

    The door station has 4 alarm inputs. I know that 1 can be used for the button that opens the gate. How to connect and use the other inputs (e.g. open gate or wicket sensor) to be able to read/receive it on the internal monitor. or in the hik connect app?

  • @faocisco
    @faocisco 2 роки тому +2

    Good explanation.
    Any idea on how to unlock the door using face comparison using the KD8003 connected to a NVR?

    • @adshikvision
      @adshikvision  2 роки тому

      ua-cam.com/video/epvcm3pPYbg/v-deo.html&ab_channel=ADSHikvisionTech
      iDS-7604HQHI/M1/FS Cheapest dvr also you can use any 2mp camera for face comparison

  • @smusyk2859
    @smusyk2859 Рік тому +2

    We've been installing these now for over a year now & believe me I had no idea u could get power from the outdoor station for locks, we always use external psu, great explanation though, any idea how to adjust lock time, as some locks just need a 2second trigger, thank you!

    • @adshikvision
      @adshikvision  Рік тому

      Use ivms4200 software to adjust lock duration

  • @harmz83
    @harmz83 2 роки тому +1

    Hello @ 9.25 can the no touch button get 12V red & black from the intercom device - connect to 12V and GND? I don’t understand why there is a need for an additional power supply. Also with this config - does the touch button open both locks or just one? Please confirm. Thanks

    • @adshikvision
      @adshikvision  2 роки тому

      lock 1 only you can connect exit button

  • @amrsalem6930
    @amrsalem6930 2 роки тому +2

    Would it work for DS-KD8003-IME1/NS?

  • @user-ow5xj6gx1l
    @user-ow5xj6gx1l 5 місяців тому +1

    Thank you for the detailed video! where do you set up the second lock? you show how you enable it but do you do it from the control panel ?

  • @RomanSliva
    @RomanSliva 9 місяців тому +2

    Loop 12V to GND? :-) 12V to COM

  • @fabiogameiro8816
    @fabiogameiro8816 8 місяців тому +1

    Will it work with DS KIS101-P exterior Module to avoid having an additional 12V power unit for door lock?

  • @markopraprotnik7824
    @markopraprotnik7824 Рік тому +1

    Great, thank you! I finally made it working! The guide wasn't much help.

  • @josemota4702
    @josemota4702 2 роки тому +1

    Good job. It is possible do the same, without power supply, on the DS-KV6113-WPE1?

  • @alphak8526
    @alphak8526 9 місяців тому +1

    Sir i installed kis 602 to s-200el i connected as you shown but lock not opening it just touches the relay with low force and if use adapter it doesnt work at all...please help sir iam requesting you

  • @drszantosi
    @drszantosi 2 роки тому +2

    Thank you so much for this great tutorial!

    • @adshikvision
      @adshikvision  2 роки тому

      You are so welcome!

    • @drszantosi
      @drszantosi 2 роки тому

      @@adshikvision Dear friend! I alredy installed the complete system and it works fine. Now i'd like to connect an additional EXIT button to open the same electric lock. My object is to control the same lock with more Exit buttons. I figoured out , that the "No touch" Exit buttons's yellow line is an NC contact. I tried to connect both Exit buttons to the same connector (AIN3) but it won't work....If i connect the buttons in 2 diferent inpunts (AIN3 and AIN4) than i hear the relays noise but unfortunately the AIN4 button opens the NO2/NC2 contacts. What do think, how is it possible to install and connect 2 exit buttons? Thx
      Here you can watch my setup: ua-cam.com/video/DOAROtT1BPc/v-deo.html&ab_channel=drszantosi

  • @McGafferTV
    @McGafferTV 2 роки тому +1

    is POE enough to hold the mag locks i thought you would need a 12v power supply input to the external door station???

    • @adshikvision
      @adshikvision  2 роки тому +1

      its depend upon your poe switch performance. most of the installer using this method but they are not facing any issue.

  • @randalejupp
    @randalejupp Рік тому +1

    Hello, great video! What lock do i have to use at 1:30? I have installed a 10-24V AC/DC (effeff 118e500 a71) lock. does this work?

    • @adshikvision
      @adshikvision  Рік тому

      Device will share 12V only. but your lock 10-24V AC/DC (effeff 118e500 a71) you need to additional adaptor for lock

  • @joaquincosiansi3344
    @joaquincosiansi3344 6 місяців тому +1

    What intercom model allows you to put two locks?

    • @adshikvision
      @adshikvision  6 місяців тому

      DS-KD8003IME1 and DS-KV8113wme1

  • @theobserwatorz88
    @theobserwatorz88 9 місяців тому +1

    What about DS-KD8003-IME1(B)/Surface ?

  • @jaskiranbrar2235
    @jaskiranbrar2235 5 місяців тому

    Thank for you this video- I tried using the DS-KV6113-WPE1 2nd Gen IP Villa Door Station to provide power to door strike but did not work. Does this only work with the Gen2 DS-KD8003-IME1? Is it because this KD8003 has a 12v power output?

    • @adshikvision
      @adshikvision  5 місяців тому

      Dear DS-KV6113 will not share power to lock..

  • @lemansmatze
    @lemansmatze 2 роки тому

    Hey ADS Hikvision Tech. The 12VDC Port you connected to COM is an 12VDC input. Hikvision officially says, you should not connect your door opener there. Now i can see you connecting the door opener there in your video and it works. We have customers who destroyed their door stations by doing that. Do you have an answer?

    • @adshikvision
      @adshikvision  2 роки тому +1

      Thanks for your comments.
      hikvision officialy not declare.
      This is a tricks, if you are a professional technician please follow this.
      otherwise use as usual lock connection.

  • @sparent1
    @sparent1 10 місяців тому +2

    hi, I performed the same installation as yours... but I have problems opening the door, I don't have the voice that says door open doesn't say anything, then if I try to open the door with the DS-KH8350 -WTE1 the screen freezes but the door is opened but without voice.

    • @adshikvision
      @adshikvision  10 місяців тому

      Update both device firmware

    • @sparent1
      @sparent1 10 місяців тому

      I updated to the latest firmware, it still gives me the same problem, as soon as I try to open the electric lock the ds-kh8350-wte1 locks out and for a minute I can't view the external station and the door open item says nothing. get resolved

    • @sparent1
      @sparent1 10 місяців тому

      Now everything works, I only have a problem when they ring and answer and as soon as I open the door after a few seconds the call stops. You can change this setting to last longer. Thank you

    • @TommyScrew
      @TommyScrew 9 місяців тому

      @@sparent1 Hi, how did you manage to solve this? I have same issue and it seems, like there is spike current, which drains power from mcu and therefore causes to reboot the outdoor unit. Will experiment with serial capacitors

    • @TommyScrew
      @TommyScrew 9 місяців тому

      So today I managed to solve this. After I checked my electric strike, it had wrong V/A ratings. I included some resistors in serial to it and now I can open gate even without external power, using just POE from switch. I have KD8003-IME1

  • @adamtopol581
    @adamtopol581 2 роки тому

    Hello, is it possible to do same on DS-KV8213-WME1. I try without sucess - where can be mistake?... Just opening dor no dor button needed.

    • @adshikvision
      @adshikvision  2 роки тому

      for dual lock you need to enable lock 2 option in intercom tab.pls watch video till end. watch 11:51

  • @loicbisson8258
    @loicbisson8258 2 роки тому +1

    Did it work with the ime2 (2 wire) because i have no voltage betWeen 12v and grd

    • @adshikvision
      @adshikvision  2 роки тому +1

      NO

    • @loicbisson8258
      @loicbisson8258 2 роки тому

      @@adshikvision thx, and do you know why i cannot connect to the interface with ivms 4200(v3.6.+) i have root only the port 8000 but when i click on the setting button only a white screen appear, (its work in local network but not in distance)

  • @user-rk9oq9qj2i
    @user-rk9oq9qj2i 2 роки тому +1

    هلا اقدر اوصل قفل الباب الى الشاشه بدل الجرس الخارجي

    • @adshikvision
      @adshikvision  2 роки тому

      no, its very difficult. لا ، من الصعب جدا

  • @petrotawa
    @petrotawa Рік тому +1

    Thanks for guide, but please help me:
    I have 2 doors to operate, one is electrical lock 12V and second is gate (without current needed).
    If i use the 12V from 8003 unit it sometimes works and sometimes not (suspect lack of current for electric lock)
    So i want to connect electric lock with external 12V adapter to COM & NO1.
    But for gate i have to use connection without any current. If i connect to COM & NO2 i can damage gate el. card due to 12V from electric lock. Do You understand me? 😮😅

    • @Jo3_Black
      @Jo3_Black Рік тому

      The relays on the door station are volt-free unless you use a separate power supply or make a bridge between 12V and COM whicg does not affect lock 2 connection

  • @lukaszbrodowski5086
    @lukaszbrodowski5086 Рік тому

    I connected the electric lock without DC, as shown in the video. And how to connect the gate which is 24v, can you help?

    • @adshikvision
      @adshikvision  Рік тому +1

      for 24 v lock u need to connect Adaptor + connect to lock +
      Adaptor - connect to intercom outdoor COM
      intercom outdoor NC connect to lock -

  • @seanbugeja
    @seanbugeja Рік тому +1

    so this model doesn't need a separate 12V PSU just to unlock the door?

  • @user-fd8hd6ii7o
    @user-fd8hd6ii7o 10 місяців тому

    Thank you. Can you tell me which electronic lock you are using?

  • @yemgaire9741
    @yemgaire9741 3 місяці тому +1

    can open slaliding gate

  • @palacx
    @palacx Рік тому +1

    Really nice guide :) could you please help me out with connection of standard push button for opening? I mean situation with standard button for exit which you need to press - is also required to connect 12V adaptor? Thank you

    • @adshikvision
      @adshikvision  Рік тому

      Use only AIN3 & GND

    • @palacx
      @palacx Рік тому

      @@adshikvision Thank you for quick answer :) I have one additional question about potential risk due to failure of electric lock to avoid damage of hikvision outdoor unit. Do you have any experience with fuse implementation to electrical circuit? I have electric lock with 12 V DC, 0,24 A ...12 V with 50 Ohm. Could you please suggest what kind of fuse would be the best to secure hikvision unit and where to implement to circuit? Thank you

  • @jayonspeed557
    @jayonspeed557 2 роки тому

    At 1:15 its a loop from 12V to COM right? Thanks for posting, its been a huge help.

  • @786kasimbk
    @786kasimbk 2 роки тому

    Tanks

  • @liononice17
    @liononice17 Рік тому

    Hi,
    I have a electronikal door, not mechanical. there are 2 wires withalready 12V on the door.
    If one of them touch the other, the door open automatically.
    How can I do this with my hikvision doorbel, could you please help me.

    • @adshikvision
      @adshikvision  Рік тому

      you can integrate outdoor to that 12v power

    • @liononice17
      @liononice17 Рік тому +1

      @@adshikvision thank you very much, which slots can I use?
      Com+No1?
      My outdoorstation is KD8003

    • @adshikvision
      @adshikvision  Рік тому

      @@liononice17 yes

    • @liononice17
      @liononice17 Рік тому

      @@adshikvision ♥️

    • @ardabeyazoglu
      @ardabeyazoglu Рік тому

      hi, i have the same situation. could you tell me how you accomplished this? where did u connect those two wires that have 12v ?

  • @TimePass-fw8zu
    @TimePass-fw8zu Рік тому

    After outdoor restart , door not open?

    • @TimePass-fw8zu
      @TimePass-fw8zu Рік тому +1

      Electric lock without using adopter i connect but not working after tic sounds come outdoor intercom will restart same connection i did (12v to com, grd to door -, no1 to door+) electric lock is 12 v but im use 12v adopter it works properly. Maybe you understand what i wrote sorry for my english Cumunication😊

    • @adshikvision
      @adshikvision  Рік тому

      check video again
      if u r using poe power u need to make a loop

  • @luispaulojavecaritas913
    @luispaulojavecaritas913 4 місяці тому +1

    Sorry, model DS-KV8413-WME1(b)

    • @adshikvision
      @adshikvision  4 місяці тому

      No option to share power to lock

  • @sparent1
    @sparent1 Рік тому +1

    Good job. It is possible do the same, without power supply, on the DS-KV8113-WME1(B)?

    • @adshikvision
      @adshikvision  Рік тому

      No Dear..

    • @sparent1
      @sparent1 10 місяців тому

      if I can only power the electric lock with the poe switch. Thank you