How to repair ? Troubleshooting of Solenoid Valve ( SV ) in Water Purifiers or RO System
Вставка
- Опубліковано 24 лис 2024
- Troubleshooting of Solenoid Valve ( SV ) in Water Purifiers or RO System.
How to solve a problem in Solenoid Valve in Water Purifier System.
सर आपका वीडियो देखकर मैंने अपना sv सही कर लिया। आपका बहुत बहुत धन्यवाद
@@sumitkatiyar1728 Thanks
Thanks for video.... water filter companies are big scam... If you compare original product cost then 4 Wheeler se bhi inka repair costly hai... Technicians to lootne ke liye besabar hai... Thanks
Thanks
@@SatyaNeer ईस sv को water dispenser मे इस्तेमाल् कर सकते हैं क्या ? pump के alternate मे !!>water bottle उलटी रहेगी > इतने कम pressure मे solenoid work करेगी ?
required in one project > input signal will be for 1 second only)
@@anandjoshi8554 Why not, at least try
Thanks for this information....
You saved my time and money 💰💰💰
My filter has issue in and out water flow after watching this video i cleaned and now its working .....
Great👍
I must say that you have explained it VERY VERY well. Short yet completely covered. Thanks a lot for making such a nice video!!
Thanks for support
@@SatyaNeer Hi Satya, I have one question. Hope you can help me with it. I have Kent RO that stopped working few days ago. After the water started flowing from Solenoid Valve, I noticed that the pump is leaking. There are many videos suggesting that the pump head can be replaced, but unfortunately on one sales them in market. All technicians suggested to replace pump - common practice to earn money.
Anyways, my apartment is on 5th floor in a 11 floor building, and water pressure is sufficient. I by-passed the pump and RO is working without pump. Would you suggest that this approach is Ok, or will it impact the RO (filters etc.) in the longer run? I guess the only impact right now is that the tank fills a bit slower.
@@priyarastogi5675
1.The same PUMPHEAD can be replaced.
2. New Pumps are also not very costly now a days.
3. Normally 60-70 PSI working pressure is required for membrane.
4. You can check incoming pressure with pressure gauge available in market for liquid application
ro filter me sv tik tik kar raha hai iska kya solution karen
@@cartoonista2019 Please check power supply is working or not, sometimes power supply keeps doing on-off due to Malfunction.
Solenoid valves usually work or are stepped completely, this problem related to power supply I think.
Bahut hi badhiya tareeke se samjhaya aapna, thank you
Thanks
Very easy and helpful video sir ji
Thanks and welcome
Khup chhan sangitale. Best.
Sir apka video dekhkar ghar par hi value sudhar liya.
@@Tuljara Great job
Practical, informative and simple. Thanks❤❤
Welcome 🎉
Very nice and very useful vedio in sort tnxxxxxxxxx
Thanks
Very nicely explained. It would b better if actual working shown by giving supply. Also include voltage / current capacity of solenoid. Is it is possible to REWIND d pump of Kent ( Primo ) brand RO Filter. Mechanic has replaced the complete motor .
@@sureshkolekar4108 Sir there are always scope left for improvements. Winding is not feasible but the pump head can be changed if available!
बहुत ही अच्छा । मैने भी क्लीन किया था पर छोटे छेद को साफ नही था।
Thank You
Good one. I learned something today.
Great👍
Thanks a lot plzzzz Jo mere comments pad rhe hae plz is video ko like nd subscribe kree ek dam real cheez btai inhone
Thanks
Very good information bhrata shree.
Thanks
You explained well . Thanks a lot .
After cleaning SV can we check it by giving DC supply of voltage ? How much voltage does SV have ? If , it is of 12 V then , then , can we check it's coil and piston by giving voltage of 8 battery cells of 1.5 volt each ?
Hello Sir
1. Depending on Solenoid Valve if it is DC operated or AC operated you can supply power accordingly.
2. Normally all manufacturers mention supply details on SV that either it's DC or AC and their operating voltage.
3. You can make battery arrangements also to make desired power that meet particular requirements of power.
@@SatyaNeer ok . Thanks sir for ur quick and valueable suggestions.
Thanks Satya it worked for me!
Great! Thanks for feedback
Very useful vedio thanks 👍
Welcome 😊
So helpful for ro repair by self
Thanks
❤Thank you so much...
Try karunga...
Welcome
Thanks for this video, my sv output pressure was very low and the filter was not working. After cleaning it's fixed.
Thanks
i did clean i got the same problem again water is not filling you faced this? after few hours
@@JaySharma45353 Please check pre filter also, that may be required to change.
Good and very informative... 👍
Actually I have also bought Water purifier aqua fresh. But all time problem coming from SOV side. It has chocked. I need to clean after 7 days. Can you give solution.
Thanks 🙂
Nicely explained....
Thanks
Thank you So much Bhai 😊good job
Welcome
Good explanation 🙏🙏
Thanks
Best video...so helpful
Thanks
Good explanation 👏
Thanks Dear
Thnx bhia kasam sa 2000 ka fatka lagna sa bach gaya aj ma
Welcome 🎉
Thanks for this helpful video
Happy to help
Aaj local technician ne ye valve replace kiya uska valve itna cheap tha original AO smith wale se still he charged 500rs
Sir mere yaha shubah ek bar aur Sam ko ek bar Pani ata hai to aise me jab inlet me Pani nhi ho tab valve ka supply pure din chalu rahe to valve khab hoga ya nhi?
@@beenitprajapati2124 Can heat and burn
Very good sir ji
Thanks
Nice/ thanks very much 👍
Welcome🎉
Mere filter ka sv me tak tak tak tak sound araha hai thodi thodi der me
Aur heat horaha hai kya clean karne ki jarurat hai ya naya lena hai
Ya adopter me fault hai
Hello Sir, regular On-Off problem related to Power Supply.
Sir mere pass Kent ka pearl ro h...usme do solenoid valve lage h....kya wo dono ek jaise hein ya alag alag hein
Please share image of product, probably they should be same
@@SatyaNeer check kr Lia sir dono sv hi h ...bs shape alag h aur andr se thoda different....ek auto flush circuit se juda h ...
Mera rubber nikla hi nahi fat gaya 😅😂😂 can I buy only housing?
Kya ise air ke liye use kr sakte h
No
Best High quality 3/8 Sole Noid valve konsa he.?
20 Nos Riquarment he pkz reply
Please visit www.satyaneer.com
Helpfull.. thanks
Thanks
Very helpful
Thanks
Actually I have also bought Water purifier aqua fresh. But all time problem coming from SOV side. It has chocked. I need to clean after 7 days. Can you give solution.
Yes Sure, Please check and tell me the position of the SV in the filter, means sequence of filters and SV
@@SatyaNeer there are only one line filter before SOV and all arrangement after SOV. There is no any other SOV. Is there any sequence of 2 hole which is present in diaphram?.
@@upendrakumar-uw9el Sir there might be carbon problem from inline or some mudd getting into SV.
Mera uv model SV hai ( not RO) 24V ka
Heating issue hai usme aur pani flow bhi thik se nhi ho rha.
Aur jitna ho rha hai woh warm water milta hai.
Please check for any blockage and clean, if not solved then replace.
Thanks bro👌🏼👌🏼👌🏼
Thank You
Kitna saal tak life time raheta hai ?
@@Thoughtreal844 Nobody can tell life.
Hi. Mr. Satya .
I purchased Acqua guard some 8 years ago . Used it for some 25 days and stopped using it after that . But , after some 1 year , I started it . But , it didn't dispensed water even after a beep sound .
I called technician . He checked it , opened SV , cleared membrane but , it didn't work . He said that , he will have to carry unit with him to get checked at his home and if there is a problem in PCB it will need repairing by technician . Estimated cost he gave , was about Rs 2000 to 2300 .
I denied bcoz I hadn't use it even for a month after purchase .
But , after four or five days I started my Aqua guard to check , if it is working or not . At my surprise , it is dispensing water well .
Is that OK ? Or not ?
Can I start using it again ?
Plz reply .
Sir if water is coming out then keep using, after all the water is coming from filters. Just check if the system is running on and off properly and if needed just replace the filter cartridge as it is recommended to change once in a year.
@@SatyaNeer thanks sir .
I checked it some 4 to 5 times .
It works well . When I power it ON Red light starts after some 15 seconds orange light starts and after some 35 to 40 seconds , green light starts and water is dispensed after a beep sound . Is it OK ?
How to check membrane ? Plz guide.
Thanks a lot again for quick reply .
What can be the cost of two filters , membrane ? My model is ," Aqua guard -- Crystal plus ".
@@deshbhaktdeshwasi2975 System seems ok as per process, for filters please connect with Aquaguard Service center and use original filters only.
@@SatyaNeer OK . Thanks for ur valueable suggestions .
❤❤
@@SmileSmile-kc5jt Thanks
Gud bro
Welcome🎉
Very nice
Thanks
SV k dono terminal se jo wire connected (adaptor se aari) hai. Dono mein current hai ... Samjh mein nhi aara kya karu.
Other units are connected in same way and working fine
Uski vajah se circuit ni complete hora aur solenoid nhi chl ra
It's DC or AC
@@SatyaNeer SMP se jo taar aati hai, jis se iske dono end connect hote...dono mein current aa ra Sir.
DC hai
@@ArshdeepSingh.. If both side current then SMPS is faulty
@@SatyaNeer lekin SMP k sath jo baki cheezein connected hai, woh Sahi chl ri hai.
Sare filtering units work kr re... Ab main SV ko hi hta diya aur direct connect ki supply filter ko toh it's working.
Kuch samjh ni aara
This solenoid valve is not working frequently because more water pressure, so if I remove this Sv and turn on my tap manually before switching on purifier. Is it ok?
Perfectly fine
@@SatyaNeer I did It, thank you so much.
Sir mera ma waste water drops ma aa rha hai aur ro tank ma water fill nhi jo rha aur ro ma vibration sound nhi aa rha to kya sv problem hai plzz reply
Hello Sir,
Follow steps for troubleshooting
1. By pass pre filters and connect input water direct into Solenoid Valve
2. From the Solenoid Valve connect to the water Booster pump.
3. From Booster Pump give connection to the Membrane.
Now check if water is coming or not.
A. If water is coming then sediment carbon filters are faulty, replace them.
B. If water not coming then remove solenoid Valve and try directly with booster pump, check if water came then ok otherwise pump or membrane or both may be damage.
Thanks
My valve is working fine but when it's ON the water coming out is in drops. How to get more water flow ?
Clean your Valve and check direct water.
@@SatyaNeer thanks I'll check
Kya ham isa direct electricity sa chla sakta ha
Depends on product to product, some product can run on AC and some can run on DC
Thank you for your reply 🙏🙏
@@SanjayKumar-io3nr Welcome🎉
Using same valve but there is leakage when valve at off condition i have also tried after cleaning it but still it is leaking water .. kindly help its my fyp and it is not working
Seems some o Ring Problem, please check
same problem face today , i will try to make.
I hope it will solve
What is the use of solenoid valve in uv uf water filter?....
Solenoid Valve is an electrical driven device that is used to turn on and off water supply in the system.
Thank yoy...
Welcome
Hello sir mera wala pani band hi nahi kar raha he. Khali button press karne se tick tick sound kar raha he
Sir if cleaning is not working, then time to change
@@SatyaNeer ok i will check
Thank you
Welcome Sir
Thanks 👍🏻🤩🤩
Thanks for appreciation
Exclusive
Kent company ko sikha dijiye sahab
Thanks
Thanks
Welcome
Filter chal raha hai but red light not glowing, what is the problem
Question is not clear
Aquasure का DX flow माडल काम कर रहा है पर स्विच बंद करने के बाद भी पानी गिरते रहता है साथ ही stating में रेड लाइट भी नहीं जलता है
@@BabluSharma-gl7bb Sir generally if solenoid valve is faulty leakage or continue flow problem appear.
Where available spare.
www.satyaneer.com
Thx
Welcome
thank
Welcome
Where do i buy this
Hello Sir, there are 2 different sizes available. 1/4" and 3/8" which type you require.
@@SatyaNeer i only want that electronic part. Dont want pipe. How much for that?my washing meachines electronic part damaged
@@SatyaNeer do you have courier service
@@SatyaNeer why electronic part damaged. Can i fix?all holes are clear
@@njan1242 Dear Sir, Non Standard Power Supply or Internal Leakage can damage coil, In that case you need to change your SV.
hi, can someone please translate, i'm having a problem with my solenoid too??
What is the problem?
@@SatyaNeer I have two solenoids of 12v, the first with no pressure and the second has a 0.02-0.8Mpa. both of them pass the water with no flow just some drops. and sometimes the first one passes the water without giving it a voltage.
now, I don't know if the solenoid always needs outside pressure or mine is broken??
@@radiamoon2395 Hello, If possible open your product and check piston mechanism it may be dirty or some deposits may be there inside the piston. If electric coil is working all problem should be solved by cleaning only.
Pls reply....
Check Power Supply
@@SatyaNeer thanks I ll check
Thanks Bro
Welcome
Thanks bro
@@jasvindersinghjasvindersin4024 Welcome
Thank you
Welcome
Thank you
Thanks