Hello. I may you help with that. It comes from the first Op. Amp. (U2) which is doing the amplification of the signal coming from the heater. You can see the U2(OP), they just changed the name in the interactive analysis. That signal is our control signal which is basically the temperature we want to achieve and which is getting substracted from the reference.
Temperatura ambiente 25°C Thremal resistance to ambiente 0.1°C/W Oven Time constant 10sec Heater Time constant 1sec Temperature coefficient 0.01V/°C Heating power 0.4kW
Intente replicar su simulacion, sin embargo no puedo, despues de una ganancia Kp de 10, el sistema ya no se vuelve mas oscilatorio. Luego pase a descargar su archivo y volverlo a poner en sus valores iniciales e igual no lo pude replicar.
SOS grande... Hasta que encuentro algo desente y bien explicado
Muchas gracias por tu aporte, es de gran utilidad.
MUy bueno la practica con la teoria.
Muito bom,gostei demais, muito bem explicado😮
buenas noches como conectaron la grafica o como le hicieron porque a mi el horno cambia de temperatura pero no muestra la grafica
Tengo una pregunta que tipo de sensor de temperatura usaron uno analógico o digital ?
Deberían bajar el valor de los capacitores y aumentar las resistencia, previene corriente mas chicas y mejora las impedancia de los OP.
Que OPAMP utilizo?
De cuanto amperes, utiliza??
En que versión de proteus trabajaron ?
La pregunta que se me ocurre es: porque no usar un arduino nano de tres dolares para el circuito??
¿Puede decirme de dónde proviene la temperatura en la ventana de análisis interactivo? ( i from vietnam and i want to discover this project)
Hello. I may you help with that. It comes from the first Op. Amp. (U2) which is doing the amplification of the signal coming from the heater. You can see the U2(OP), they just changed the name in the interactive analysis. That signal is our control signal which is basically the temperature we want to achieve and which is getting substracted from the reference.
Hola, podrías comentarme que valores has colocado en los ajustes del horno?
Temperatura ambiente 25°C
Thremal resistance to ambiente 0.1°C/W
Oven Time constant 10sec
Heater Time constant 1sec
Temperature coefficient 0.01V/°C
Heating power 0.4kW
Una disculpa, no había revisado el canal
Jale el opam U2 su medidor ala tabla de análisis i no me sale porq
Intente replicar su simulacion, sin embargo no puedo, despues de una ganancia Kp de 10, el sistema ya no se vuelve mas oscilatorio.
Luego pase a descargar su archivo y volverlo a poner en sus valores iniciales e igual no lo pude replicar.
Eso me pasa a mi también, porque sucede?
@@oscarjesusquispeyaco7388 disculpen cual es la solucion?
use un micro