Kaeser air compressor service

Поділитися
Вставка
  • Опубліковано 15 кві 2020

КОМЕНТАРІ • 52

  • @astc593
    @astc593 3 роки тому +3

    Very professional and somehow relaxing to watch!

  • @nengjuju4274
    @nengjuju4274 3 роки тому

    Setelah menonton video ini...
    Teringat lagi waktu bekerja di perusahaan di bandung...
    7 bulan yg lalu...
    Sekarang saya d rumah kan... 😃
    Saya sebagai operator + maintenance...
    Semua pekerjaan di lakukan sendiri dari mulai perawatan sampai memperbaiki nya...
    Tp kalo sudah masalah overhul ya sama teknisi dari luar perusahaan...
    Tipe mesin nya yg saya pegang..
    Kaeser As47...AT47... Dan BSD 72
    Saya sangat senang dengan produk kaeser... Simpel tapi jarang rewel mesin nya... 👌👌
    Pokok nya mantap... 👍👍
    Sukses kaeser

    • @user-hf6cg5oc3e
      @user-hf6cg5oc3e 2 роки тому

      BSD 72 alarm air discharge temperatur apa masalahnya mas,,,,,padahal sudah bongkar auto Valve bypas

  • @eliveltonnascimento1866
    @eliveltonnascimento1866 Рік тому

    Fiz esse mesmo serviço hoje 👏👏👏

  • @MMM_2031
    @MMM_2031 2 роки тому

    Which style of male air fittings do those couplers use?

  • @yumnarudi9654
    @yumnarudi9654 Рік тому

    Rekomendasi untuk oli banng

  • @mnairengineering1985
    @mnairengineering1985 Рік тому

    Good job

  • @mdnuralom2751
    @mdnuralom2751 Рік тому

    গুড

  • @radenara8759
    @radenara8759 Рік тому

    Bos kalau oli keluar dari valve elektrik pas idle kenapa ya

  • @loganthanos5036
    @loganthanos5036 2 роки тому

    We need more

  • @senukavege3930
    @senukavege3930 2 роки тому +1

    I'm dismantling the screw of CSD 105 Kaeser compressor. Please do you have another video that continue where this one has stopped?

  • @BaljinderSingh-xd5se
    @BaljinderSingh-xd5se Рік тому

    The oil separator change

  • @swooshkrusty
    @swooshkrusty 3 роки тому +2

    Hello! I did maintenance on Kaeser sk 15 and after that when I started my compressor again the check valve is activated ( back pressure valve ) If you have time could you please explain what I did wrong .

    • @ibey01
      @ibey01 3 роки тому +1

      Did you open the ball valve on the vent valve?

    • @BobJons
      @BobJons 2 роки тому +1

      В чем проблемы?

    • @garretthoward13
      @garretthoward13 Рік тому +1

      Minimum pressure valves dont activate. Solenoid valves activate and that would be your loading valve.

  • @amusementtechnician3676
    @amusementtechnician3676 Рік тому

    Nice

  • @713ROBLO
    @713ROBLO 2 роки тому

    So I have a question I have a keaser Diesel compressor so when I let it run for 10-15
    sec and when I start to load it, it shuts down do you know what can cause that?

    • @cjworks6668
      @cjworks6668  2 роки тому

      check the internal pressure build up maybe no

  • @garretthoward13
    @garretthoward13 Рік тому

    Just had to call out a blown cooler on friday for this exact unit. Not a fan of this unit. They love to puke up oil from the inlet valve whenever a power outage occurs or if the unit is turned off while loading.

  • @rezayudistira1911
    @rezayudistira1911 4 роки тому +2

    very nice 👍

  • @martinbaria8584
    @martinbaria8584 2 роки тому

    Good day . I have a compressor kaeser ask 35 T screw type. How to fix oil leak at air filter? Please help thanks

  • @LukmanHakim-lg6ui
    @LukmanHakim-lg6ui Рік тому

    Klau tulisan alarm apa masalahya

  • @barrycalvert8219
    @barrycalvert8219 2 роки тому

    We need someone this good in West palm area. The Schmucks from Compressor Works, other than their top 2 techs are worthless, sign off, and are gone

  • @Dkosnica
    @Dkosnica 11 місяців тому +1

    How do you drain oil from up there ?

    • @ToxiicZombee
      @ToxiicZombee Місяць тому

      I watched this whole video just to figure out how to drain the oil and the one thing I wanted to see wasn't on here

  • @ukgupta1068
    @ukgupta1068 3 роки тому +3

    What's a problem of ADT

    • @lucadhaloiti9718
      @lucadhaloiti9718 3 роки тому

      @@cjworks6668 que tal si desea le puedo ayudar

  • @UmairKhan-lr7qb
    @UmairKhan-lr7qb 3 роки тому +2

    Dear sir,
    I hope you are well in covid situation. I need your valuable guidelines regarding kesar screw compressor.
    I am facing the problem with my kesar screw compressor sxc4 for more than a week.following are the malfunctions noted during operation.
    a. air receiver should hold 12 bar pressure while working, where as it is holding only to bar of pressure during operation.
    b. On turning off the system, air receiver should retain all of its pressure until it is intentionally drained through shut off valve. Now it is automatically drained out trough condensat drain line on turning off the system.
    c. System has three air reservoirs which normally have 9.8 bar pressure.Now all the three reservoirs have only three bar pressure, and on turning off the system all the three reservoirs are automatically draind out through compressor condensate drain line.

    It is noted that sigma control display is not showing any fault message.
    It is humbly requested that kindly indicate the probable fault in the system.

    • @PigFucker-hs8ct
      @PigFucker-hs8ct 3 роки тому +1

      simple: shut the condensate drain valve and reservoir outlet valve then observe the cut off pressure and time.check suction filter for clogging and intake valve opening.

    • @erickangel6478
      @erickangel6478 3 роки тому +1

      Check for leaks in your pipelines, and test the system closing all the recervoir outlets, then you´ll be able to find if the leak is in any part of the tanks or if it is located in a pipe connection or in any of the machines that uses compressed air. Tell us how it is going.

    • @mnairengineering1985
      @mnairengineering1985 Рік тому

      check intake valve fully open or not

    • @mnairengineering1985
      @mnairengineering1985 Рік тому

      May be intake valve seal required to be changed

  • @rajashiraz9335
    @rajashiraz9335 2 роки тому

    today i dismanteld this type of compressor keaser same modle and i done my job only 30 minute. take care

    • @huppagaming480
      @huppagaming480 3 місяці тому

      Jhut to thoda limit me bol le bhai

  • @erickangel6478
    @erickangel6478 3 роки тому +2

    Why did you remove the airend lid?

    • @olivierbenoit8986
      @olivierbenoit8986 3 роки тому

      To change the seperator cartridge kaeser compressor are made like that

    • @erickangel6478
      @erickangel6478 3 роки тому

      ​@@olivierbenoit8986 You must be mistaked, I said, Airend lid, I din´t say separator tank lid

    • @olivierbenoit8986
      @olivierbenoit8986 3 роки тому +1

      My bad, I read to fast haha! I thought the exact same thing this step was really useless

    • @erickangel6478
      @erickangel6478 3 роки тому

      @@olivierbenoit8986 Ok bro, don´t worry

  • @garretthoward13
    @garretthoward13 Рік тому

    Why you dig into the air end to do a service?

    • @cjworks6668
      @cjworks6668  Рік тому

      Just replaced the gasket

    • @filip6665
      @filip6665 7 місяців тому

      Sorry for bothering you, but if you can give me some troubleshoot infos regarding airend high temp., well, when compressor is enough cooled down it starts normally and working good but when stops and if I need to start it right again it is triping due to high airend temp then need to wait again for couple of hours more in order to cool it down to be available to start again.What can be the issue?
      Thank you in advance!

  • @kompresorairteknologi
    @kompresorairteknologi 2 роки тому

    Screw Compressor Problem Oli keluar dari Airend Screw ke Filter udara (Kondensasi) Terlalu Banyak Unloading, My Video : ua-cam.com/video/zRytf2qNwWo/v-deo.html

  • @mateovelarde8657
    @mateovelarde8657 Рік тому

    Lo más malo en compresores qué conozco asta ahora

  • @BobJons
    @BobJons 2 роки тому

    Рукожоп.