How to Repair an LJX Rotary Joint & Cantilevered Syphon

Поділитися
Вставка
  • Опубліковано 3 сер 2024
  • This video shows the removal, repair, and re-installation of the Kadant Johnson LJX rotary joint and cantilevered syphon. Specifically designed to retrofit critical rolls on the single facer, the LJX rotary joint and syphon system is a heavy-duty, robust combination engineered to deliver maximum heat across all board combinations and enhance safety around the single facer.
    Disassembly & Repair Instructions: bit.ly/3aJakqG
    Learn more: fluidhandling.kadant.com/en/p...
    Chapters:
    00:00 Introduction
    00:37 Step 1 - Release residual pressure in the system
    00:45 Step 2 - Remove the hex nuts
    1:07 Step 3 - Bend tab outward and loosen the retention nut
    1:26 Step 4 - Remove the hex nuts
    1:37 Step 5 - Horizontal syphon pipe removed
    2:11 Step 6 - Remove the quick release nipple flange
    2:28 Step 7 - Disassembling rotary joint
    2:49 Step 8 - Remove the retention plate
    3:06 Step 9 - Inspect and replace potentially damaged parts
    3:48 Step 10 - Begin to reinstall the parts
    4:28 Step 11 - Alignment of keyways
    4:51 Step 12 - Slide the quick-release nipple flange
    5:08 Step 13 - Assembly of horizontal pipe
    5:46 Step 14 - Place a new metal gasket
    6:00 Step 15 - Install the rotary joint and syphon assembly
    6:20 Step 16 - Slide the nipple into the journal flange recess
    6:53 Step 17 - Check the rotary joint components for alignment
    7:11 Step 18 - Tighten the retention nut
    7:27 Step 19 - Reinstall the head using the gasket
    7:54 Step 20 - Install hex nuts
    8:28 Step 21 - Slide a spacer
    8:51 Step 22 - Connect the piping
    Subscribe Now! ua-cam.com/users/subscription_...
    Let's Connect
    LinkedIn - / kadant-inc-
    Instagram - / kadantinc
    Twitter - / kadant
    Facebook - / kadant
  • Наука та технологія

КОМЕНТАРІ •