Rietveld Refinement of X-ray Diffraction Data Using FullProf Package - Part I

Поділитися
Вставка
  • Опубліковано 22 жов 2024

КОМЕНТАРІ • 248

  • @hectorgperez
    @hectorgperez Рік тому +1

    My Chi2 improved tremendously, thank you for the tutorial.

  • @avinnamishra6777
    @avinnamishra6777 3 роки тому +3

    Our Xpert is now Online. Grt

  • @santanusamai1758
    @santanusamai1758 11 місяців тому +1

    Thank you so much, sir, for this great tutorial.

  • @avery-ryanansbro7432
    @avery-ryanansbro7432 Місяць тому

    Hello, thanks for this tutorial. On the off chance you are still answering questions about this, is FullProf capable of multiphase quantitatvie analysis? The software I used for my school has been taken away and replaced with a software that consistently overfits data to the point that it cannot be used and I am trying to learn Fullprof to complete my paper. Before, I used RIR analysis to analyze a multiphase sample with cifs I saved to my computer, but Fullprof is not able to read the space groups from this. When I put in some space groups manually, I am told the spacegroups I insert do not exist (even though I am taking them directly from the CIF files and they are identical to what is on something like COD). Do you have any advisement on how to get past this issue?

  • @UdayKumar-gc3br
    @UdayKumar-gc3br 5 місяців тому

    Thank you for the video. You have negative y-coordinate (atomic position) for Oxygen, you kept that value as it is throughout whole refinement. Why didn't you consider that one? Can we visualize the unit cell with your refined atomic position?

  • @shahfahad1854
    @shahfahad1854 19 днів тому

    Thank you sir, how I can create IRF file for my sample. My sample is MOF

  • @sehreishabrar492
    @sehreishabrar492 2 роки тому +5

    Hello sir, can you explain how to do refinement for material whose CIF file is not available such as 4 to 5 elements high entropy material

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      Your question is hypothetical. Kindly give the name of the different phases in your samples so that I can suggest how to go for refinement. If your cif file is not available first go for indexing and find the lattice parameters. Then see all the possible space groups of the examined material reported in literature. This may be temperature dependence data or pressure dependent data. Check the PE loop. That will also check whether the space group is centrosymmetic or not. I am taking a example here. BaTiO3 is a prototype ferroelectric. It has R3m, P4mm, Amm2 and pm-3m space group possibilities. What ever you dope or how you prepare the sample it will be in this space group only. The best fit is your space group. I hope this is helpful. I can not write a lot here so sorry for that.

  • @adeelanaz9818
    @adeelanaz9818 2 роки тому +2

    I want just refining graph that you create ,so where's I can ?

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Please ask your question with more precisely.

    • @adeelanaz9818
      @adeelanaz9818 2 роки тому

      I can solve this issue and successfully rietveld( BiFeO3) XRD.Now I am working on (SrBi4Ti4O15) but facing different error when I am running like,no reflection found,there is an error in your input file , please tell me about that issues

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      Check the intensity file and make sure that you have put the correctly wrote space Group.

  • @dpkchemistry9379
    @dpkchemistry9379 2 роки тому +1

    Sir, it was great tutorial. Thanks a lot

  • @mohammadalterawe4037
    @mohammadalterawe4037 2 роки тому +2

    how i can get the XRD data file (observed data) for the FeSb2 powder sample .
    Or, is the data export from the cif file considered observed data?

    • @satyanarayantripathy
      @satyanarayantripathy 2 роки тому

      Your question is not clear. The observed data is xrd data collected from diffractometer and calculated value if from cif file.

    • @mohammadalterawe4037
      @mohammadalterawe4037 2 роки тому

      @@satyanarayantripathy Thank you, that's what I want

  • @Subhashree_Subudhi
    @Subhashree_Subudhi Рік тому

    Thank you for the Informations... can we use Rietveld refinement analysis for thin film samples..?

    • @physicsdoneright
      @physicsdoneright  Рік тому

      The thin film xrd backgrounds are very noisy. You can simulate a xrd graph to find the peak position. I will not recommend doing rietveld refinement for thin film xrds.

  • @VeerPutraMikku
    @VeerPutraMikku Рік тому +1

    Hello! Sir i have tried every possible video on the youtube to refine my data, and the least value of chi 2 is still not less than 8. Can you please do my refinement?

  • @RitikRoshanTripathy
    @RitikRoshanTripathy 3 місяці тому

    Average apparent size cannot be calculated (no size broadening)!
    Possible reasons: (1) The broadening of reflections is resolution limited
    (2) No size parameter has been refined
    (3) The resolution function is not properly given
    this issue generation on doing in fullprof. Another thing is that after following your steps, my chi-square does not decrease to near 1. It stays 68. I tried refinig atomic positon but On doingit doesn't proceed
    how to resolve this issue??
    Another issue I am getting with doing gsas , I face a issue no reflection in the pwdr limit i do not get. I this it becomes after refining which leads to unrelaistic histogram scale factor and zero off set.
    what are ur views
    can i get ur contact??

  • @nancyjangra3055
    @nancyjangra3055 2 роки тому +1

    Thanku sir for such a great information but i have some doubt.......How to make IRF file

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      To make a IRF file you need to run a standard sample in the XRD diffractometer. You can take standard as LaB6. Run this sample in the machine and collect the information like two theta, fwhm, peak shape parameters. Check one of the example file in the FullProf and put your own data for LaB6 measurements. Enter the IRF file when you convert cif to PCR.

  • @dedukahopkinsinstitute8063
    @dedukahopkinsinstitute8063 Рік тому

    I have two quiries plz sir do reply
    1) i dont have that third file which u were talking about . I have cif file and my xrd and copied the intensity and made a new dat. File.
    1)I am getting cycle 1 and chi2 :558 . .
    How to proceed from here

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Increase number of cycles and start refining parameters in the list given in PPT. Anyways your question is very general. Kindly be specific.

  • @sushiljoshi9655
    @sushiljoshi9655 2 роки тому +1

    How can we do refinement for the compound whose cif file is not available

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      This a crucial case. Do the indexing. It will suggest a structure and lattice parameters. Then run the data in expo to find probable space group. Next do a polarization measurements to understand the space group is centro symmetrical or non centosymmtrical. Compare your structure with similar compounds. At end see the fitting with lowest chi2 of the each space group.

    • @sushiljoshi9655
      @sushiljoshi9655 2 роки тому

      @@physicsdoneright
      Is this possible to use 2 cif file for 1 compound, by the combination of two

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      @@sushiljoshi9655 yes. That is basically done for dual phase refinement. You can have even 3 cif files. That's the beauty

  • @neekitashah9209
    @neekitashah9209 2 роки тому +1

    Sir i am doing refinement of my sample but at doing refinement of atomic position its show conver. Not yet reached... Pls help

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Tell me the sample name. I hope you have not correctly put the atomic position. Download the cif and then import. Please mail me with the problems you are facing. Satya

  • @HuggumsMcgehee
    @HuggumsMcgehee 2 роки тому +1

    How would you handle a doped sample? It's very common to dope BiFeO3 with a number of different things and their aren't free CIFs for everything.

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      If you want to dope a element at A site of B site of the BiFeO3, add the element in the atom information with the atomic positions of A site or B site depending upon the size of the atom/ Ion. foe example if i want to dope Lanthanum in BFO then i will use Bi atomic position of BFO for La. This procedure can be done if the lanthanum substitution dies not change the structure of BFO. You can use same R3c. But if the substitution of La changes structure, then you have to go for dual phase refinement. foe example, 15% of La doping drives the crystal symmetry to rhombohedral and Orthorhombic dual phase. So, I have attached 2 papers link for your reference. Please read, if you have any problem mail me.
      aip.scitation.org/doi/abs/10.1063/1.4916927?ver=pdfcov&journalCode=jap
      DOI:10.1088/2053-1591/abdd50.
      Enjoy.
      Regards
      Satya

  • @dpkchemistry9379
    @dpkchemistry9379 2 роки тому +1

    Dear Sir, why 2 theta peak position is not copied in CIF file?

  • @thangamaalikad7790
    @thangamaalikad7790 2 роки тому +1

    Sir I couldn't import data file in full proof suite, what to do?

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      Kindly check in PCR file what is the number below "job". If this is not zero make it zero. Alternative, you can name you data file and PCR file same name. Just check.

  • @roshinigurram3971
    @roshinigurram3971 2 місяці тому

    Hello sir, how are you telling that at 9.50 sec while you are running the fullprof software you mentioned that it doesn't converged or something...what does it mean and how you are telling that I mean under what basis?... Please reply

    • @physicsdoneright
      @physicsdoneright  2 місяці тому +1

      Please read the output lines during each cycle run. It's written there

  • @Eyiedaartandcraft
    @Eyiedaartandcraft 7 місяців тому

    Sir yah app nay 2theta ki values khud sa add kii hain ..?

  • @mubeenjakati7495
    @mubeenjakati7495 Рік тому +1

    How , can I download spectra of given sample after refinement

  • @vidhishukla3033
    @vidhishukla3033 2 роки тому +1

    does the atomic position of each atom changes significantly while doing the refinement?

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      All atoms will not change sign. It may be possible that few atomic position may change sign.

    • @vidhishukla3033
      @vidhishukla3033 2 роки тому

      @@physicsdoneright sir actually the fractional coordinate values changed significantly, like : 0.5 changed to more than 0.6

  • @mayssabrahim8419
    @mayssabrahim8419 2 роки тому +1

    and why you chose 15 for cycles of refinement ?

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      You can start minimum with 10. The choice of this number basically depends on the convergence of the profile fit. You will know it after 2 to 3 cycles of run.

  • @D4Hstudygroup
    @D4Hstudygroup 8 місяців тому

    When we click on RUN Full pruf after making PCR file we didn't get any FP file

  • @deepayadav1562
    @deepayadav1562 Рік тому +2

    I need to estimate error in unit cell parameter, please help

    • @physicsdoneright
      @physicsdoneright  Рік тому +2

      The error in lattice parameter is only active when the refinement tick is active in the box. To see the error, first refine and then check in the output file or sum file.

    • @jeet9402
      @jeet9402 Рік тому

      @@physicsdoneright sir i need a help…i have created a separate data file that includes 2 theta min , max , intensity…but whenever we browse the xrd data file then its not showing in that folder…folder shows empty…i can not select any xrd data file..plz help me

    • @jeet9402
      @jeet9402 Рік тому

      @deepa mam u can also suggest something regarding this?
      sir i need a help…i have created a separate data file that includes 2 theta min , max , intensity…but whenever we browse the xrd data file then its not showing in that folder…folder shows empty…i can not select any xrd data file..plz help me

    • @physicsdoneright
      @physicsdoneright  Рік тому +1

      Please make sure that it is in dat format

  • @dollyparekh8513
    @dollyparekh8513 2 роки тому +1

    Sir, if I choose Occupancies unrecoverable divergence reached how to solve this?

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Fix it as per the multiplicity of the site. Check the multiplicity number in cif file

    • @dollyparekh8513
      @dollyparekh8513 2 роки тому

      Thank you sir

  • @alhassana.sallau9574
    @alhassana.sallau9574 2 роки тому +1

    Thank you sir, Am trying to refine a synthesized sodium silicate crystal xrd pattern against a cod 2106900 reference phase in fullprof and am get warning!! The fractional coordinate in almost the H exceeds 1.2!.
    Please is there a way i can remedy the warning as the refinement won't converge. While having a high chi^2 value of 13.9

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Kindly mail me your data with the exact chemical formula and how you synthesized the sample. I will run it and let you know.

    • @alhassana.sallau9574
      @alhassana.sallau9574 2 роки тому

      @@physicsdoneright thank you sir, ii have sent you an email with the required files

  • @qaisali2087
    @qaisali2087 Рік тому

    Thank you very much for this tutorial. Can we convert PCR file to CIF file? I have seen an option for that, but am not fully aware of the process. And what if we have multiple phases in the pattern, can we get multiple phase information in PCR file while doing peak search and keeping the numbers less than 20, which is recommended to create PCR file via FullProf?

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Thank you for your questions. 1. Certainly, you can convert PCR to CIF from the output option menu. But that file format is not in the standard format as per COD or other databases. If you want to create the CIF file please see the formats of databases. 2. Yes you can do multiple phase refinement and you can get the percentage of each phase. Kindly see my video for the rietveld part ii which is basic for dual phase or multiple phase. I always recommend to create PCR files from CIF files. If you will edit other PCR files to create your own sample PCR then some of the hidden parameters will have non zero value inside and the pattern will not converge to low rp or two values. I am happy to answer your question.

  • @divyam6864
    @divyam6864 Рік тому

    Thank you so much for this tutorial, I have a problem with my refinement of YBCO, The refinement won't converge and I'm having a chi^2 value of 0.145E+04

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Read some papers before running the package.. atleast the manual

  • @pavithram6611
    @pavithram6611 9 місяців тому

    If i didn't get CIF file for particular composites means what can do ?

  • @ankitlabh
    @ankitlabh 2 роки тому +1

    Hi, do you also know if it runs on MacOS? I have tried but everything works except loading background file and running the fullprof which generated that red colored data and fitted profile. Strange, but do you have any idea how to solve it?

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      I have no idea with Mac OS run of fullprof.

    • @louie6730
      @louie6730 10 місяців тому

      i'm running it on MacOS via wine-crossover. it works just fine

  • @patnayakunitulasirao4524
    @patnayakunitulasirao4524 3 роки тому +1

    thank you for giving good information sir about me
    but we doped different materials like (NBT-BT-BFO ternary phase diagram)
    how to arrange the atom position, please explain me

    • @physicsdoneright
      @physicsdoneright  3 роки тому

      Okay. I understood you question. NBT is R3c or Cm depending on Polling. BT is p4mm and BFO is R3c. So if you have ternary phase then you need a simultaneous 3 phase refinements. Yes that would interesting to see. Go to the phase in rietveld and add all 3 phases separately. Then refine.

    • @physicsdoneright
      @physicsdoneright  3 роки тому

      I have uploaded a video for Doped sample. You can check how to select atomic positions.

  • @yuziksphysics4034
    @yuziksphysics4034 2 роки тому +1

    I am doing your all step sir but my chi2 6.5 and please help sir how I can proceed for next?

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Tell me your Rp, Rwp, Rexp values. Tell me your how your took data means step size and data scan rate and range. Check in the SUM file that model is satisfactory or not.

    • @yuziksphysics4034
      @yuziksphysics4034 2 роки тому

      Rp45 Rexp 25 Rwp 50

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Peaks are not fitted well. If you have completed all the refinements then i guess that your data collection may be creating problems. All XRD data are not eligible to make rietveld refinements. You need to take step size 0.01 min, slow scan rate 1 degree per min and range 10 to 90. You can still report with chi2 with value 5 but R paramo must be below 6 at least.

  • @AbhayaPrasadaMohapatraph20d035

    What does it mean by converge? I did not get that. You repeated three times and finally told it is now converged. Can you please tell me how to know whether it is converged or not? Thank you for this insightful video.

    • @physicsdoneright
      @physicsdoneright  Рік тому

      It's written on the screen at the end of each run. When each run is conducted by changing a parameter and then parameter will reach its optimum value, it will show that convergence is reached.😊

    • @AbhayaPrasadaMohapatraph20d035
      @AbhayaPrasadaMohapatraph20d035 Рік тому

      @@physicsdoneright Thank your for your response. Still did not find the converge term in the screen. Sorry for that. Can you please send the screenshot by highlighting this? Thank you.

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Check time scale 7.30: it is showing normal end.
      Check 9.49: it's showing convergence yet not reached.

    • @abhayamohapatra2292
      @abhayamohapatra2292 Рік тому

      @@physicsdoneright Ok, Thank you. I will check and let you know. Thank you very much.

  • @ankitaduttachowdhury3204
    @ankitaduttachowdhury3204 Рік тому +1

    Hello sir, please let me know where from can I get the example BFO_DataFP since it is not available in website/example bundle.

    • @JJResearch-md4cp
      @JJResearch-md4cp 4 місяці тому

      This is the same file that you saved under the name ‘data.data’. I observed that there was an error in saving it with the ‘.data’ extension instead of the correct ‘.dat’ extension.

  • @Deepikasharma-et2do
    @Deepikasharma-et2do Рік тому

    Thank you so much sir, it was very helpful but I still have some doubt, can you please make a video on how to refine the data if there will be shifting of hkl peaks to right and to left with doping.

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Check my paper on Materials Science and Engineering B 294 (2023) 116511

  • @thiyagarajselvaraj9359
    @thiyagarajselvaraj9359 3 роки тому +1

    If doping, how to find the exact sym and wyck positions of newly dopent material? Can we choose ramdamly or any other else?

    • @physicsdoneright
      @physicsdoneright  3 роки тому +1

      Dear Selvaraj, Kindly specify the exact compound and dopant that you are using. This is a general question. In the example video, the material was R3c space group BiFeO3 and its a perovskite. If I do a rare earth doping it will put chemical pressure at A site means Bi site. But substitution at Fe site do not introduce structure change. and the structure changes to R3c to dual phase R3c+Pnma. These are my papers for reference.
      1. aip.scitation.org/doi/abs/10.1063/1.4916927
      2. iopscience.iop.org/article/10.1088/2053-1591/abdd50/meta.
      Thus, please specify you sample and dopant so that I can suggest space group for you.

    • @physicsdoneright
      @physicsdoneright  3 роки тому

      I have uploaded a video on effect of doping and how to select atomic position. You can check.

    • @thiyagarajselvaraj9359
      @thiyagarajselvaraj9359 3 роки тому

      @@physicsdoneright thanks sir, mine is R-3 and R-3m

  • @Mustafa2015
    @Mustafa2015 3 місяці тому

    Sir, how to get an IRF FILE FROM REFINEMENT

  • @suchendraspoetrylane6256
    @suchendraspoetrylane6256 2 роки тому +1

    Hello Sir,
    Thanks for the video .
    I am trying to do reitveld refinement for my sample . But after doing all the steps when I start the refinement , I am getting an error like "error on intensity file, check your instrument parameter parameter". please kindly suggest me regading this.

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      This problem is due to step size or spacing issue. The input file format is wrong.
      Please check the steps as follows
      1. Line 1: initial 2theta then space then step two theta then space final 2 theta.
      example: 20.00 0.02 79.88 (Note: Check your data. It may be up to 4 digit after decimal.)
      2. Line 2: paste the intensity value
      Save in filename.dat

  • @sreelakshmi6376
    @sreelakshmi6376 Рік тому

    For me after running, the blue colour is showing as straight line only instead of xrd graph. Also cycle 1 chi 2 : 00 is mentioned please identify the problem?

  • @AkashKumar-qf3bq
    @AkashKumar-qf3bq 2 роки тому +1

    Sir, how to resolve invalid character in a numeric field
    After this error all data in profile and atoms got swept

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Yes, I can understand your problem. This problem usually happens but I don't have a scientific suggestion for this. I copy the folder to some other place before running the fullprof.

  • @JyotiYogiraj
    @JyotiYogiraj 5 місяців тому

    sir my elements are co zr fe o i am unable to find out CIF File for theses

  • @MA-ff9th
    @MA-ff9th 2 роки тому +1

    How do you know convergence is not reached during run

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      The displayed value of Rp and Rwp and chi2 at the end of refinements will decide the experiment data has converged to theory or not. Always check SUM file generated at output.

    • @MA-ff9th
      @MA-ff9th 2 роки тому

      @@physicsdoneright can you please explain in detail because I am new to refinement. Please.

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Please call me over phone. My details available at info.

  • @harshini3964
    @harshini3964 5 місяців тому

    Sir, even though the cycles for refinement is given 15, only 1 cycle is running for me. I have tried so many times. What might the problem. Could you please explain it.

  • @a.....k.....520
    @a.....k.....520 3 місяці тому

    Hello sir, can you explain how to do refinement for material whose CIF file is not available such as 6 elements how make the CIF file phase name and lattice parameter is know how to make the cif file plz help me how manual make Cif file

    • @physicsdoneright
      @physicsdoneright  2 місяці тому

      Tell me your sample chemical formula. Your question is not clear

  • @sasankpattnaik81
    @sasankpattnaik81 2 роки тому +1

    Can you provide us the IRF file format or instruct how to create it

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Thanks for asking. To create data for IRF file you need to take a data for LaB6 in your diffractometer where you have taken your sample data under examination. Then from the xrd data of LaB6, find 2theta, Lorentzian shape and Gaussian shape parameter. Then keep the data in the format shown in rietveld example file. And finally run in the software

  • @fakharshahzad4809
    @fakharshahzad4809 18 днів тому

    sir cycles set ni ho rhy 15 krta hn dobra 1 ho jata ha \

  • @amritapathak5913
    @amritapathak5913 10 місяців тому

    Thank you sir for the video. However, even after following each step it's not running for my case. Everytime it's showing, job interrupted and pattern 1 not found.

    • @physicsdoneright
      @physicsdoneright  10 місяців тому

      Check the job is set 0

    • @amritapathak5913
      @amritapathak5913 8 місяців тому

      The job is set to 2, so should I make it 0? And also there are two patt# showning@@physicsdoneright

  • @sramesh2062
    @sramesh2062 3 роки тому +1

    I want do size and strain analysis for CeO2, will you tell how to prepare IRF files, if possible please send model file. After refinement, using winplotr, I have generated IRF_HG. IRF_Hl, and IRF_Hpv. Using these files I have plotted in Origin, is this procedure is ok or not.

    • @physicsdoneright
      @physicsdoneright  3 роки тому

      You can take any file format described in the fullprof examples files. To make a IRF file you need to run a standard sample like LAB6 in the same Diffractometer where you have take that XRD data of the sample and replace the lorentzian and gaussian components in the IRF file format and run the sample in full prof. Or you can do the BREADTH package which is much advanced for size strain (i have another video uploaded for that)

    • @sramesh2062
      @sramesh2062 3 роки тому

      @@physicsdoneright Thanks for the information

  • @amartyasau9968
    @amartyasau9968 Рік тому

    cant fix the value of individual isotropic thermal parameter to positive value.alwayas one value become negetive .what to do.

    • @physicsdoneright
      @physicsdoneright  Рік тому +1

      See the literature report value of thermal factors of the particular elements for the compound. And fix the value. Do not refine it. The thermal factors should be a positive value because it is the displacement in angstrom square.

  • @chandrashekharjoshi5120
    @chandrashekharjoshi5120 2 роки тому +1

    Could anyone tell me how can I get cif file for rare earth doped ferrites

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      www.crystallography.net/cod/
      rruff.geo.arizona.edu/AMS/amcsd.php
      materialsproject.org/
      icsd.fiz-karlsruhe.de/authorization/demoAccount.xhtml;jsessionid=5C7DA6584A48E1C66BBE61F51153FBC2

  • @paulinanowakowska7744
    @paulinanowakowska7744 2 роки тому +1

    I keep doing the analysis as in your video and always getting "error on intensity file, check your instr parameter". Do you have any idea how to fix it? (My Ins = 0)

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      Please make sure you have prepared the intensity file in correct way. The intensity file must have intitial 2theta then space then step 2theta then space final 2theta. Then enter and paste all the intensity data. I hope your step size is not written properly. Note: First try to run the intensity file data in winploter, then run in full prof.

    • @ashwina5472
      @ashwina5472 2 роки тому +1

      I also faced the same problem.Instead of uploading dat file we can upload .xrdml file by choosing PANalytical in the format.That helped for me

    • @paulinanowakowska7744
      @paulinanowakowska7744 2 роки тому

      @@physicsdoneright it was a problem with .dat file indeed, thank you!
      Now I'm facing a problem with refinement - it is quite good (chi2=32), but one peak does not appear in it. (If I manually increase the scale it appears). I'll be grateful for any tips from you.

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      This is a technical issue. Unless i know the structure, XRD data and space Group, i can not comment on your question.

    • @paulinanowakowska7744
      @paulinanowakowska7744 2 роки тому

      @@physicsdoneright is it possible to reach you via other platform?

  • @2210kaustav
    @2210kaustav Рік тому

    Yobs - Ycalc is a almost flat line (less than 200 points diff and major peak intensity is around 18000) yet Chi2 value is around 10, what can be the reason/reasons for this, Sir?

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Kindly paste the output of sum file in the rietveld output

  • @physicswiras6950
    @physicswiras6950 Рік тому +1

    Sir what is the need of IRF files

    • @physicsdoneright
      @physicsdoneright  Рік тому

      In theory xrd profiles are not broadened but due to crystallite size, strain and dislocation or due to experimental part, peak shapes broaden. So we need a instumental file that accounts for the broadening not resulted from the sample it's self. It's optional in fullprof. If you want to calculate crystallite size or strain from full prof, you may need that file. I can not write more here. Please see literature

  • @NaeemaNaeem-s6t
    @NaeemaNaeem-s6t 9 місяців тому

    Hlo sir, hope you are Fine. Sir, in atomic scale parameters my software did not refine it. It shows the conv is not reached... I tried so many times but it only shows conv is not reached kindly guide me what should I do now... If I have to change the parameters or any other process then tell me how can I do. Thanks and regards

    • @JayEaster-ky1gq
      @JayEaster-ky1gq 7 місяців тому

      Hi,
      I had the same issue and tried increasing the number of refinement cycles (iterations) to 30 and then 50. Convergence usually reached before 50 cycles in each case. I hope this helps.
      Best.

  • @chiranjitchaliha5318
    @chiranjitchaliha5318 Рік тому

    Is it really necessary for the v value of FWHM parameters to be negative sir?

  • @ayanroy9185
    @ayanroy9185 2 роки тому +4

    Thank you for the tutorial video.... It's very helpful for the seeker like us ... Also due to elaborative explanation regarding each parameters it is unique for the refinement procedure...
    Btw I have a question regarding IRF file ... How can I get the IRF file???
    Is there any issue if I used the IRF file of LaB6, given in example file.... If possible can I get your email ID???

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      Hello, take a xrd data of LaB6 from the same diffractometer from which you have taken your samples data. It is a property of the instrument. You can't use the lab6 file available in the example file of the installed software.

  • @soniaahlawat9130
    @soniaahlawat9130 Рік тому

    Good morning sir..... If unrecoverable divergence occur what should we do??

  • @mayssabrahim8419
    @mayssabrahim8419 2 роки тому +1

    Please how we determine the values of B ?

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      You can start the refinements from 0.1 to the optimized refined value. You can also check previous refinements single crystal data of your samples. Note that B values not to be negative.

  • @nandanm8199
    @nandanm8199 10 місяців тому

    I am getting the error of reload .pcr file, if I click yes or No, nothing is coming afterwards. what could be the issue

  • @dpkchemistry9379
    @dpkchemistry9379 2 роки тому +1

    Sir from where we can get IRF file?

  • @nabasmitasaikia6415
    @nabasmitasaikia6415 2 роки тому +1

    Sir how can we find CIF file for La0.75Gd0.25FeO3?
    Pls help me sir

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      materialsproject.org/materials/mp-542920/. This is for LaFeO3 which is a pnma structure. You can you add one atom for Gd with same atomic position as La.

    • @nabasmitasaikia6415
      @nabasmitasaikia6415 2 роки тому

      Sir, where you get the value of range?
      You write in the notepad before copy intensity values

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      I did not understand your question. Please write in mail with detailed question.

  • @AnkitAnkit-po3gy
    @AnkitAnkit-po3gy 10 місяців тому +1

    hi, wht if we dont know the phase

    • @physicsdoneright
      @physicsdoneright  10 місяців тому

      This method is a structural refinement process that means you need to have a reference model. If you don't know the phase try to find the space group from various structural determination software.

    • @AnkitAnkit-po3gy
      @AnkitAnkit-po3gy 10 місяців тому

      ITS DIFFICULT BUT THANKS
      @@physicsdoneright

  • @shahbazkhan7249
    @shahbazkhan7249 Рік тому

    Can you explain why use tch axial input instead of pseudo voigt?

    • @physicsdoneright
      @physicsdoneright  Рік тому

      The TCH pseudo-Voigt profile function (Thompson, Cox and Hastings, J. Appl. Cryst. 20, 79 (1987)) is used to mimic the exact Voigt function and it includes the Finger‘s treatment of the axial divergence (L.W. Finger, J. Appl. Cryst. 31, 111 (1998)). I took it with an aim for crystallite size and strain calculations.

  • @raufabid1925
    @raufabid1925 Рік тому

    Hello Sir,
    I have followed same steps as you have followed, I have encountered an error of too many position please help me out.

  • @2210kaustav
    @2210kaustav Рік тому

    Estimated values of Figures of Merit: goodness of fit (χ2), profile residual (Rp),
    weighted profile residual (Rwp), expected weighted profile residual (Re) and
    background corrected reliability (R) factors (cRp, cRwp, cRe) where to get these values?

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Check the output file or SUM file

    • @2210kaustav
      @2210kaustav Рік тому

      @@physicsdoneright okay sir, but which ones are the background corrected Reliability factors? cRp cRwp and cRe values

  • @JitendraPPH
    @JitendraPPH Рік тому

    Dear Sir,
    I m doing all the steps according to you…but it shows the singular matrix errror…
    i need urgent of this…can i send u cif file and raw data file?

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Dear, do not refine all the parameters at same time. If refining a parameter gives you singular Matrix then keep it fixed with its CIF file value. people often get singular Matrix dialogue box in u,v,w and occupancy refinement. Keep them fixed.

  • @AsifKhan-kc2rg
    @AsifKhan-kc2rg 2 роки тому +1

    Greetings sir, hope u will b fine sir. Sir i am not abel to find any data neither in COD nor in ACD can u plz help my
    My system is Yb2NiMnO6

    • @physicsdoneright
      @physicsdoneright  2 роки тому +2

      Okay. The structure is a combination of 2 crystallographic phases. P21/n and R-3c. Try this dual phase.

  • @manjupriya6574
    @manjupriya6574 6 місяців тому

    sir how to make IRF file?

  • @lekshmi833
    @lekshmi833 2 роки тому

    Sir, after doing cif to pcr, in the pattern section I have tried to upload my data file. But it keeps showing the cif file I have uploaded earlier.

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Please make your question clear.

    • @lekshmi833
      @lekshmi833 2 роки тому

      @@physicsdoneright Sir, I have a DAT file. So without using CIF file downloaded from COD, I directly browse my data file in the pattern section and I have entered the values of lattice parameter, B, X, Y, Z, Oct and angles in the refinement section. After saving this, I have tried to run fullprof. But it keeps showing some error..

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      @@lekshmi833 please make sure 1. U, V, W parameter 0.06, -0.05, 0.08 put its starting value, 2. Then make sure you have chosen the right peak profile and shape

  • @ANJALIBHATTACHARYYPHD
    @ANJALIBHATTACHARYYPHD Рік тому

    Sir When I am going to run after inserting the intensity data, It is showing too many points..
    Can you please help Sir..

    • @physicsdoneright
      @physicsdoneright  Рік тому +1

      Mail me your data. Let me have a look. I think step size is very very small.

    • @ANJALIBHATTACHARYYPHD
      @ANJALIBHATTACHARYYPHD Рік тому

      @@physicsdoneright Sir can you give your Email-id please.

  • @VeerPutraMikku
    @VeerPutraMikku Рік тому

    Is chi 2 value of 5.25 acceptable for research paper?

    • @physicsdoneright
      @physicsdoneright  Рік тому

      5.25 is allowed. if and only your data quality is extremely high with low Rp, Rwp, Rexp factors

  • @devarshivyaskshitij1599
    @devarshivyaskshitij1599 8 місяців тому

    how to download irf file?

  • @bhagyashrigaykwad1274
    @bhagyashrigaykwad1274 2 роки тому

    Dear sir, could you please tell me the permissible value for Rp, Rwp and Rexp for reporting in a paper

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      www.cambridge.org/core/journals/powder-diffraction/article/r-factors-in-rietveld-analysis-how-good-is-good-enough/17439A1F889B689C495549A234D53682

  • @KULDEEPSINGH-hl6oe
    @KULDEEPSINGH-hl6oe 2 роки тому +1

    Thanks, sir for the nice and valuable video, I need the Al2Mn2O7 compound atomic position for Rietveld refinement please provide me if possible.

    • @KULDEEPSINGH-hl6oe
      @KULDEEPSINGH-hl6oe 2 роки тому

      or provide me cif file, I search COD but not able to find that.

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      _cell_length_a 8.181 _cell_length_b 8.181 _cell_length_c 8.181 _cell_angle_alpha 90 _cell_angle_beta 90 _cell_angle_gamma 90 _cell_volume 547.544 _exptl_crystal_density_diffrn 4.120 _symmetry_space_group_name_H-M 'F d 3 m' loop_

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      _atom_site_label
      _atom_site_fract_x
      _atom_site_fract_y
      _atom_site_fract_z
      _atom_site_occupancy
      Mn 0.12500 0.12500 0.12500 0.89000
      Al 0.12500 0.12500 0.12500 0.11000
      Al 0.50000 0.50000 0.50000 1.00000
      O 0.26550 0.26550 0.26550 1.00000

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      Try this one.

    • @KULDEEPSINGH-hl6oe
      @KULDEEPSINGH-hl6oe 2 роки тому

      @@physicsdoneright Sir, compound belongs to monoclinic and space group is P2/m

  • @richabharti9705
    @richabharti9705 Рік тому

    After doing all the steps i am not able to run the program

    • @jewelthomas1097
      @jewelthomas1097 10 місяців тому

      I too had this problem. The problem was with my antivirus deleting some important files after scanning for the virus. If u have an antivirus, try refining once before scanning or add FullProf files to ignore list.
      Hope your issue will be resolved.

  • @priyaDharshini-gb7yb
    @priyaDharshini-gb7yb 3 місяці тому

    i have biggest doubt in dat file making

  • @riyadawn181
    @riyadawn181 2 роки тому

    Hello sir.. thank you for the tutorial.. I am following the refinement process 10-12 runs, but still my chi2 value is 333 and the graphs r not converging. Is there any process to resolve it?

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      Please send me you data with cif file. I will run and let you know. Mail me

    • @riyadawn181
      @riyadawn181 2 роки тому

      Ok.. sure Sir

    • @kashmireducationpoint3668
      @kashmireducationpoint3668 2 роки тому

      @@physicsdoneright the cif file of my sample is not available and i got the chi square 177 which taking the hypothetical data what can i do now

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      Tell me the sample chemical formula exactly.

    • @kashmireducationpoint3668
      @kashmireducationpoint3668 2 роки тому

      @@physicsdoneright will u please send me ur mail id

  • @sitaramarajus1
    @sitaramarajus1 2 роки тому

    Helo, Can you please share a video how to plot 3-D graphs of Reflection loss

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      That's easy with origin. You really need a video on that??

  • @RitikRoshanTripathy
    @RitikRoshanTripathy Рік тому

    How to do if CIF file not available

  • @megharana5670
    @megharana5670 8 місяців тому

    how to get irf file

  • @raufabid1925
    @raufabid1925 Рік тому +1

    Can you do for me my sample is La Sr Mn O3

    • @physicsdoneright
      @physicsdoneright  Рік тому

      It's a easy structure. R3c or pnma may be. You can easily get the CIF file.

  • @gvishnumurthy1704
    @gvishnumurthy1704 Рік тому

    Good Morning Sir .How to download IRF File sir.

    • @physicsdoneright
      @physicsdoneright  Рік тому

      IRF is called an instrumental resolution file. You need to create that file. You need to take xrd data of Si or LaB6 in the same diffractometer where you have taken the xrd data of the sample to be refined. Kindly check my 2 videos in the playlist, how to create IRF files.

    • @gvishnumurthy1704
      @gvishnumurthy1704 Рік тому

      @@physicsdoneright thank you sir

  • @kaushiksanyal4744
    @kaushiksanyal4744 2 роки тому

    where do you obtain IRF file?

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      I have answered this many times. Please read other comments.

  • @gaargie
    @gaargie Рік тому

    If job is not zero then??

  • @minakshipadhy6689
    @minakshipadhy6689 Рік тому

    Hello sir I have mailed you regarding my problem please sir help me

  • @priyaDharshini-gb7yb
    @priyaDharshini-gb7yb 3 місяці тому

    i need tutorial for dat file making

  • @sakshithakur8927
    @sakshithakur8927 2 роки тому

    Hi Sir.. Please mention ur mail id. I didn't found that on ur profile. I need to learn this software... I am having issue while puting pcr file b4 refinement

    • @sakshithakur8927
      @sakshithakur8927 2 роки тому

      @@physicsdoneright Sir need to know one thing, in the intensity file, u have written 0.02 value, where does it come from?

    • @physicsdoneright
      @physicsdoneright  2 роки тому +1

      It is the step size of 2theta

  • @DorothyLewis-j6e
    @DorothyLewis-j6e Місяць тому

    Kutch Tunnel

  • @sarojs.1999
    @sarojs.1999 Рік тому

    Sir can u please help me in this regard..i tried watching this video but facing some problems to do it.. can u please provide email id to reach u... For my research it's urgent

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Email id is given in the channel enquiry page.

    • @sarojs.1999
      @sarojs.1999 Рік тому

      Sir unable to find ur email id ..i tried...can plz send here for few minutes

    • @sarojs.1999
      @sarojs.1999 Рік тому

      @@physicsdoneright thank you Sir

  • @JitendraPPH
    @JitendraPPH Рік тому

    sir whats your email

  • @AQLILI
    @AQLILI Рік тому

    Dear Dr. I followed all the steps but the lowest chi2 value I could get is 6.8. And I don't know how to proceed. Could you please help me? My material is cubic BaTiO3.

    • @physicsdoneright
      @physicsdoneright  Рік тому +3

      You can refine the following parameters such as anisotropic thermal factors, use of IRF file, different background files, peak asymetry. I note that if your rp, rwp, rexp are still less than 10, you can still report higher chi2 values even 5 or 6. If your data quality is very high means the data has been taken in very slow scan and step size 0.01, you may also get higher chi2. Poor data often gives low chi2.

    • @AQLILI
      @AQLILI Рік тому

      @@physicsdoneright Thank you Dr for the reply. I will try per your suggestions.

  • @nikhilmn9687
    @nikhilmn9687 Рік тому

    Sir i am getting "Error on intensity file, check your instr parameter " what to do sir plz tell me sir

    • @physicsdoneright
      @physicsdoneright  Рік тому

      Check that the spacing between initial 2theta, step and final2theta.

    • @nikhilmn9687
      @nikhilmn9687 Рік тому

      I checked sir
      It schould be one spacing right sir??

    • @nikhilmn9687
      @nikhilmn9687 Рік тому

      @@physicsdoneright any other mistake ?
      How to rectify it sir plz tell sir i am fedup with this error from long time

  • @sabashahin_
    @sabashahin_ 2 роки тому +1

    How to find IRF file?

    • @physicsdoneright
      @physicsdoneright  2 роки тому

      I have answered this question many times in the comments.

  • @haidersaleem3854
    @haidersaleem3854 Рік тому

    Sir, my pcr file on job column is not zero it is 2, whenever i load the pcr file it shows error what is the possible error

  • @laxmikantbanaj3485
    @laxmikantbanaj3485 Рік тому

    how to find irf file ?