Vacuum ka process or electric Trane Chiller ma Kese karty dosra Oil separator ma Oil jab kam ho jai to compressor ko oil kaha se ree fill karengay or ketna karangy?
Boss 1 ans to do mjhe ap r 22 ka suction pressure 60 to 65 hi q Hota h 100 q nhi Hota or high pressure per chiller q trip Hota h or high pressure kis Waja se Hota h
Q ki higher the pressure, higher the temperature agar pressure 100 kar diya to cooling nahi hogi, kyki evaporator ka temperature badh jayega. 2) Condenser chock hone se system high pressure pe trip hota hai, ya water cooled condenser me scaling ki wajah se.
Sir Reynold company chiller kya kya Karan se Thanda nahin Ho Raha hai sar please ismein bataiye kyunki yah unit mein ismein pani ka temperature 42 degree tha aur jab chillar unit mein in hota hai to uska temperature kam hona chahie kyunki iska pahle 20 degree Tak aata tha aap bhi 42 degree ja raha tha temperature 42 degree batata hai isliye please sar iska kya machine mein क्या-क्या Karan ho sakta hai jo Kam nahin kar pa raha hai
Hallo sir Thanks for you [ IN Hibited by External source Waiting for bas communications ] The is problem in chiller trane What is the probability of this problem???? Tat means it Waiting for signal for you BAS "building Automation system " that's what tells it to run or you can run it off local that will run off temperature not on off signal for BAS system What about the solutions
Aap se sahi se samjhaya unki location and there work ko explain kiya. ❤❤❤
ua-cam.com/video/jzi4sGJo1iM/v-deo.htmlsi=ldKtZooTtpG9gRRu
Really Helpful Information For Us Thanks
Great job brother, keep it up 😊
Good Examplen HVAC Chillers 10 Safety Device 100% Thank you
Hi abul gani how areyou
Bhut achchha hai bhut aasani hui samjhne main..
ua-cam.com/video/jzi4sGJo1iM/v-deo.htmlsi=ldKtZooTtpG9gRRu
Sir very powerful teaching dete he aap 👍
ua-cam.com/video/jzi4sGJo1iM/v-deo.htmlsi=ldKtZooTtpG9gRRu
Great bhai jaan bahut hi achchha vedio hai 🙏👍
ua-cam.com/video/jzi4sGJo1iM/v-deo.htmlsi=ldKtZooTtpG9gRRu
Useful information ❤brother and thank you for your valuable sharing information to us
SIR daikin ka challir h usme mchenicl lwo pressure svich ka alarm aa rha h
To 50se niche hoga to alarm ⏰bajta hoga preassur thik karaw
Boss your. Wau of teaching is super ❤️
Thank u sir for best information
Very nice n informative video.Thanks.
Really very excellent explanation
Nice chiller safety
Very good explanation
Thanks for sharing
Glad it was helpful!
This is Really Awesome knowledge.
Thank you for your feedback
Thanks good information
Pressure relief valves kiya kaam hai HVAC me kahan fiting hote hain
Sir Actuator kitne tarah ke hote hai kaise kam karte hai kinta volt se kam krta hai plz iske upar ek video bnaiye
Or vav ka bhi
Kaun sa category uded karu bhai
Vacuum ka process or electric Trane Chiller ma Kese karty dosra Oil separator ma Oil jab kam ho jai to compressor ko oil kaha se ree fill karengay or ketna karangy?
very nice procedure video
Daikin ka chiller hai .. oli level switch ka alarm ata hai daily..??
Cooling tower me water ka temperature check Karo,kafi Kam hoga
Thank you sar 👍sar yese or video seyar sar
Thanks bro Good video 👍🏻👍🏻
Hloo..sir Chiller ka pm karne ke liye kitna time lagta hai??
Depends on system capacity .
Super information 👍
Thank you sandip
Good Explanation very Thanks sir
Hello sir
Kirloskar ka chiller hai to uska 2nd compressor chalu nahi hotay to kya kare
Sir Trane Electric Chiller ko vaccum kese kartay ha?
Sir please boliye accha Institute chiller plant ka kahan hai aur age bhi Aisi related main yah sab kam sikhana chahta hun
Well explained,Thanks for the information
Your welcome
Sir fild me kaise pata chale ga ki compressor ke pumping down hai iska uper akto vedio baniya sir ❤️🙏
Okay sir
Very good sir 👍
Thankyou
Sir 3 phase water chiller ka wiring diagram par video banaye.
Ye wiring google youtube kahin nahi h
Ok sir
Nice video sir 👍
Very good bro
awesome Explanation
Sir Daikin ka Chillar ka low discharge superhit Jaane per kya karna chahie sir please bata do sar
Cooling tower temp 85f se above hona chahiye and chiller run karne se pehle cooling tower fan run mat karo and set point temp 48 f tak rakho
Bro chiller water flow loss and condenser water flow loss what is the reason chiller alarm?
Nice work
Sir plants operating system ke uper videos banoo 🙏
Bhai ek video VSD chiller par banayein, aur electrical side par kuch knowledge dein.
Okay sir thanks for your feedback.
Good explain
Bahut badhiya ji
thanks vai from jeddah
Your welcome.
Nice jankari sir ji
Thank you
Hii sir Rheem company ki ac hai fan ki ispeed hai karne par compressor ban hojata hai keya problem h
Thank you sir
Thanks for information
Your welcome sir
Really informative video 👌
Thanks
Excellent dear
Very helpful video
Thank you so much for your feedback
Where installed relief valve in chiller
Good explain bhae
Superb 👌
Thank you
Sir Refrigeration ka prasaure kitna hona chahiye
Good explanation sir thanks
Very nice🙏🙏 thank you so much..
Your welcome
Sir expansion valve ko command kanha se milta hai
Very knowldgable
What is the compressor ratio of the Reciprocating compressor sir eska answers Kay hai
Looking forward for more informative videos
Chillar ma kon kon si gas usa hoti hai
ua-cam.com/video/eMBN7AgeciA/v-deo.html
Sir
Chiller me R 22 hi kyu dali jati
32 ya 410 kyu nahi
Please reply me ⚘⚘⚘⚘⚘⚘⚘
Because of high pressure.
Nice information sir
Thank you
Make a virtual training also for this
HP aur LP switches individual circuit ko trip karwatay hain.
Lp aur dp switch kahan lagayajata
Chiller par video banaye plz 2 Ton
Boss 1 ans to do mjhe ap r 22 ka suction pressure 60 to 65 hi q Hota h 100 q nhi Hota or high pressure per chiller q trip Hota h or high pressure kis Waja se Hota h
Q ki higher the pressure, higher the temperature agar pressure 100 kar diya to cooling nahi hogi, kyki evaporator ka temperature badh jayega.
2) Condenser chock hone se system high pressure pe trip hota hai, ya water cooled condenser me scaling ki wajah se.
good information sir
How to find H.P , LP and safeties are oky performance?
Manually increase pressure in system and check whether it trips on HP and manually decrease pressure to check LP
Thank you very much
good video sir ,
Sir agr hvac related koi wtsp group hai to plz add me or share the grouop link 🙏🙏
Nice sir ji ❤️
Cn possible to explain chiller control diagram stap by stap air cooled York yciv model or 30 gx carrier
I will try.
Nice sir 👍👍👌👌
Thank you
Low temperature ka alarm kyo aata hai
Thank you sir ji
So nice of you
Modern device to protect chilers please
Bhai phase alarm my hota hai iska ans do na
Nice
Thanks
Ye sab to thik hai but kitna pressure hona chahiye ye nhi btaya
Sir chiller low set me trip hotahe
Yes
Sir Reynold company chiller kya kya Karan se Thanda nahin Ho Raha hai sar please ismein bataiye kyunki yah unit mein ismein pani ka temperature 42 degree tha aur jab chillar unit mein in hota hai to uska temperature kam hona chahie kyunki iska pahle 20 degree Tak aata tha aap bhi 42 degree ja raha tha temperature 42 degree batata hai isliye please sar iska kya machine mein क्या-क्या Karan ho sakta hai jo Kam nahin kar pa raha hai
Check chilled water outlet sensor
Chillar ma kon ko sa comparasar usa hota hai
Loved it.
Anti cycle me trip ho to kya kar e
Hallo sir
Thanks for you
[ IN Hibited by External source Waiting for bas communications ]
The is problem in chiller trane What is the probability of this problem????
Tat means it Waiting for signal for you BAS "building Automation system " that's what tells it to run or you can run it off local that will run off temperature not on off signal for BAS system
What about the solutions
Good 👍👍
Excellent
Petra package unit coming 1 alarm A055
So wonderful
Sir mujhe chillar ka working nhi samjh aata hai
We will make a video on this topic.
Good 👍
Thanks u sir
Nice vedio
Thank you🙏
Thanks
Great!