Design of 2 way slab using Etabs Tutorial - Direct Design Method

Поділитися
Вставка
  • Опубліковано 9 лис 2024

КОМЕНТАРІ • 25

  • @EngineeringLearningPlatform
    @EngineeringLearningPlatform  5 років тому +3

    Watch "How to Design of 2 way slab using Etabs Tutorial - Direct Design Method"

  • @awadheshkumarmaurya2818
    @awadheshkumarmaurya2818 2 роки тому +1

    Best tutorial in Utube on slab modelling. But I did,nt find till the slab modelling & design one way simply supported (slab edge not restrained on wall/ beam) on brick wall.

  • @theprobattleknight4185
    @theprobattleknight4185 5 років тому

    Nice video for detailing and design of rcc slab on etabs tutorial - Thumbs UP!!

  • @rafiullahsultani9723
    @rafiullahsultani9723 Рік тому

    Hi
    I hope you are fine and doing well.
    Mashallah i apperciate you leacture really i learned too much thing but i thing i need those excels shets if you guide me how i can get those it will be your pretty contribution

  • @aqsaneaz7904
    @aqsaneaz7904 3 роки тому

    very helpful video. Great platform to learn.

  • @atiqahmadjan9175
    @atiqahmadjan9175 5 років тому +1

    thumbs up bro! I Have one question how to know that the load applied to the slab are correctly transfer to the beam ? can we design the slab beam and column in the same project?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 років тому

      yes but in different runs as when designing beam and column we need to take slab as membrane, and when designing slab we take as shell thin type and also apply construction load on ground floor.

    • @atiqahmadjan9175
      @atiqahmadjan9175 5 років тому

      @@EngineeringLearningPlatform Thanks for your kind remarks. I would add another question why we can't use shell-thin and apply load on it(shell-thin) and then design everything in the same project? as the shell-thin cant transfer the load to the beam accurately?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  5 років тому

      @@atiqahmadjan9175 shell thin is no doubt realistic, but membrane condition is rather conservative.

  • @nicolasmarie4398
    @nicolasmarie4398 5 років тому +1

    Hi. What do you mean by Framing: Intermediate Moment Resisting Frame? Can I use metric equivalent, do simply supported solid 2-way or 1-way slab on beam and use BS 8110 code using Etabs? For simply supported slab, how should the beam dimension be considered as for example 425x150 means the height of 425 include thickness of 125 mm. for slab and 300 for the web of the beam with each element being cast at different time (hence simply supported) and 150 is the width of the beam. Thanks for those precision.

  • @aqsaneaz7904
    @aqsaneaz7904 3 роки тому

    Sir, if span in both direction are not same then we have to take L/4 for the shorter one?

  • @Mohsinbagban
    @Mohsinbagban Рік тому

    Can you do make one for 2 way slab with ratio greater than 1?

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  Рік тому

      Sorry what do you mean

    • @Mohsinbagban
      @Mohsinbagban Рік тому

      @@EngineeringLearningPlatform
      I am working on a project. It has multiple 2 way adjacent slabs of varying Lx and Ly.
      I have assigned Edge releases M=0 & T=0.001 to all edges for effect of Simply supported.
      Used strip method for analysis.
      Strip A for short span and Strip B for Long span of slab for every individual slab.
      In local axis of slabs, I have given 90° wherever short span is along Y axis.
      After analysis, I am seeing slab moments max in Strip B (long span) rather than in Strip A (short span).
      I tried multiple stuff but it just doesn't go right..

    • @Mohsinbagban
      @Mohsinbagban Рік тому

      @@EngineeringLearningPlatform In short, I'm getting more My > Mx

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  Рік тому

      Don't release moments ofcourse@@Mohsinbagban

    • @Mohsinbagban
      @Mohsinbagban Рік тому

      @@EngineeringLearningPlatform Whether I release moment or not, the answer is same. I get My>Mx.
      The middle strip width I consider is
      0.5L + 0.5R =1m

  • @dilipngangom4198
    @dilipngangom4198 4 роки тому

    What is the load combination of long term deflection in Indian code?

  • @hariasssss
    @hariasssss 5 років тому +1

    Please post video shear wall design and detailing.

  • @engwahidkohistani5638
    @engwahidkohistani5638 4 роки тому

    Hi this method is very long time get how can design direct methods design please add in chenal