LASTO-LRB Type Testing acc. to EN 15129 for CE Certification

Поділитися
Вставка
  • Опубліковано 31 бер 2011
  • Type Testing performed in two full-scale LASTO®LRB Isolators according to the European Norm EN 15129. The testing was carried out at EUCENTRE in Pavia, Italy.
  • Наука та технологія

КОМЕНТАРІ • 11

  • @carlosmendezg
    @carlosmendezg 12 років тому

    @Drafty01 Hi, thank you very much for your comment. mageba Lasto®LRBs are designed and tested to withstand several earthquakes. The use of lead with 99.9 % purity, and high quality rubber ensures that the performance of the isolators will be optimum even after being subjected to several earthquakes. The LRB are designed to withstand the maximum seismic condition of the project, in terms of force and displacement, which are usually earthquakes with high magnitude (> 7).

  • @Roma43534
    @Roma43534 10 років тому +5

    Some questions:
    What happen with the high frecuency energy from the earthquake? Rubber only damps low-medium frecuencies...
    What happen when the deflection is higher than expected in radial direction and brings down the dampers?
    What happen when temperature under structure increases up to 60ºC? This is common and rubber suffers a big damage under this range of temperature for ages
    The rubber dampers have shelf-life a very much shorter that building structures. So, what happen when the build is 20 years old and a earthquake comes?
    What happen when the differential stabilization under the building try to lean or incline the structure? How can a vertical damper stop a catastrophic horizontal displacement?
    It looks marvelous, because this very simple test can support anything... but not the damper.
    My friend, reality is harder than we think...

    • @lotconvosotros1668
      @lotconvosotros1668 6 років тому

      Si miras la estructura del aislador, es muy fácil cambiarlo, los tornillos se quitan y listo. La estructura es muy simple y barata, dos placas de acero y una masa de goma. Puede cambiarlos mucho antes de que se agote su vida útil. De hecho, funciona como los neumáticos de tu auto, cambias los neumáticos antes de que se vuelvan peligrosos. PLOP!

  • @guN_Ners
    @guN_Ners 6 років тому +3

    Canon music.... ;)
    Thnks for video..

  • @restymorales320
    @restymorales320 Рік тому

    Can I use this video for an educational presentation?

  • @Drafty01
    @Drafty01 12 років тому +2

    How many earthquakes of its rated performance would this system endure before failure. I'm from New Zealand, (also known as the Shaky Isles). In Christchurch, there are 3-4 magnitude 3 - 4 every day, with magnitude 5 & sometimes 6 every few months.

  • @professorbland
    @professorbland 11 років тому +4

    why not use skrillex for the soundtrack instead?

  • @havehalkow
    @havehalkow 10 років тому +2

    what's the name of the soundtrack, please?

  • @rayudu.gudipudi6009
    @rayudu.gudipudi6009 5 років тому

    May I know that equipment