Generator Repairing Course Part # 15 [ Head Install Method ] ( Urdu / Hindi )
Вставка
- Опубліковано 9 вер 2024
- Video by : Zia ul fahad
Generator Repairing Course Part # 1 ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 2 [ Rotor And Stator Out ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 3 [ Carboreter Tappet cover Out Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 4 [Head Out Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 5 [ Camshaft And Piston Out Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 6 [ Flywheel, Battery Coil, Crankshaft, Governor Gear, Out Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator repairing courses part # 7 ( piston rings,crankshaft Details)(Urdu/Hindi)
• Generator repairing co...
Generator Repairing Course Part # 8 [ Connecting Rod Piston Rings Install ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 9 [ Piston Install Desi Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 10 [ Governor Gear Install Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 11 [ Crankshaft , Camshaft , Install Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part #12 [Battery Coil ,Self ,Flywheel Install Method](Urdu /Hindi)
• Generator Repairing Co...
Generator Repairing Course Part # 13 [ Rotor And Stater Install Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 14 [ Engine And Body Fit Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 15 [ Head Install Method ] ( Urdu / Hindi )
• Generator Repairing Co...
Generator Repairing Course Part # 16 [ Lgnition Coil Carburetor Install Method ] ( Urdu / Hindi)
• Generator Repairing Co...
Generator Repairing Course Part # 17 [ Governor Setting ] ( Urdu / Hindi )
• Generator Repairing Co...
Zia bhai ap se bohat kuch sekha he ap ka bohat shukria Allaha ap ko hamesha khush rakh he ameen.
Zia Bhai you have done the great job apki videos se bohat sikhne ko milta hay thank you
waqas.m. khan aapka adress aur mobile number mere ko WhatsApp kijiye
Fantastic job zia bhai ap ka explain krny ka style bht aala Hai Allah ap ko sehat kamyabi dy👍
Very informative. Nice way
zabardast...aapki aik hi video se me ne head fix ker dia ...Allah aapko khush rakahy
زبردست
Bahut hi badya vedio banaya ap ne Alhamdulillah
bht umda, kuch doubt bhi clear hue mere.
love from India
Very nice explanations
رحم الله والديك وفق الله في الدنيا والآخرة جعل الله جميع أعمالك في ميزان حسناتك وجمعنا في الفردوس الأعلى من الجنة اللهم آمين يارب العالمين يالله
Thanx 💖
nice Brother i m successful after watching your video
Good teacher
best video of tapping setting brother.
Best bro 👍
sr thank u ap zabardast asan vidio banate ho
Thanks for uploading another video
Good 🌹🌹🌹
Good job👍👍👍
Bahuta axh vodyo hai sar g
❤
Gracias por presentar videos como el que acabo de ver
four stroke engine 1)suction 2) compression 3)POWER 4) EXHAUST
nic
thanks zia bhai
Good work I love it
Thanks bro
Zabardas
Good Enough
Thanks
جيد جدا شكرا
Sir video boht achi hai laykin range maloom karni k cheez ka naam bataain
Is tool ko
feeler gauge
Bolty hn ya hardware ki shop sy mil jata ha
Online ma mil jata ha pr online thora mengha milta ha
Bht hi aala information. Mere generator ko abhi new piston lageae hain. Usky bad gas pr start b nhi hota and load pr blast krk band hojata hai. Kindly suggestion den.
How to findout the walve it's ok or replace. Vedio is very good Thanks.
very good
Nice
Nice explained, very helpful
AoA. Thanks for urs nice n beautiful post. Ager measserment strip na ho tu kis s fitting kren kis exray k paper s kam chal gaiga pl inform thus thnks jazakalla
Zia bhai bohat zabardast andaz main samjhate ho ap , ek problem hai Ganrater dhowa nahi se raha lekin oil bohat kam kar raha hai , 3 se 4 ghantay main 700 ml main se 300 ml kam kar raha hai , is Ki kya wajha ho sakti hai
Nice video
🌷🌷🌷🌷🌷
Good
sir nice
Zia Bhai apki videos dekh kr men apny Ghr ka generator khood theak karta hoon apki videos bohot atchi hen sekhny ko bohot milta Hy, jazakallah. Fault k bary men guide Karen plz, k ham faults ko kysy pakren or kysy unko theak Karen, apka phone numbers bhe share karden plz
Men apko subscribe kardeta hn notification k liye
Sir ji Hame gas Cricket ki setting karniy syga
Sttng up 15 maximum lock...
FITTING K BAD CONNECTIONS KA BTA DAIN
Asalam o alaikum zia bhai patrol avrege kum ziyada karne barai mai kuch batain
Start generator
Sir fly wheel ka wiring batao plz
Zia Bhai wall me se air nikal rahi he me Kya karo ab
Bhi 4.5 kwa ka dynamo kitna gak mila ga generator ka liya
Regards
GEO BROTHER
Thank you. Can you make a video for generator switching panel with circuit diagram.
Ok
Thank you.
Assalam o alaikum
Help me
2.5 janerator oil seel lagana ha
Kia motor nikalne k bad katora nikalna hoga ya bager nikale seel laga don.
5kb generator patrool settings
Good job
Tappet head ki gasket kitni ki milti hai?
Assalam.o.alaikum bhai m jb head cover k uppar jo breather pipe laga hota h wo filter main lagata hn to engine bethny lagta h q or filter foam bhe lagao to yahi condition hoti h....
Piston top par hony k sath sath presher point par bhi hona chaheya
Can I use the razor instead of the ruler for the purpose of the generator if it is not available and the percentage of the razor is measured?
Zia bhai ik msla ya ha k genratao par Pankko KO hawa km ha Kio haal bataen plz
Start generator 0.. 0 tak dpat hdup.. 2 mm dpat star tali star
Engine our yentinetar alag kaise karte hai
Choke last mai rkhny pr start hota hai choke musalsal hil kr Gen band hojata choke ek jagy pr rok nhi rhi hai problem halp
Choke ko tu mane hath Sy rok kr bhi dekha hai phr bhi Koch time mai band hojata hai hit up bhi hojata
Generator ke konsa wall bara hota h
Mike eangan
sir 12 ka pana lagegaa
Zia bhai Jo generator smoke zyada create krta ho us ka kia hal h
Bai ap boht axa samjate ho lakin kis nat bolt ko kon sa pana wagera lagta he plz wo sath sath bata diya karen
Sharafuddin Welcome to my UA-cam channal
G ma try karo ga new video ma ye sab bata dn
Ap ne tool ka b pocha ha to tool ap 2.5 k lye
8 , 10 ,12 num ka T pana le lo
Ye zyada use hoty hn
Is k ilwa kotti ka pora set milta ha choty wala ap ko 700 tak ma mil jay ga
Or 1 bada set b ata ha jo 1500 sy 2500 tak ma milty hn alag alag company k
Tappet/head waly area se oil drops araha hai
Any reason?
Salaam zia bhai mera genretor start nh ho raha.bus plug side se pataka marta h mera matlb blast ki awaz aati h.plz ap bataiye
Zia bhai mere generator ki kick back mar rahi he iss k bare me kuch bta sakte hen ap
kick back marny ki main waja camshaft ka theak sy kam na karna ha
2nd waja hoti ha valve ki setting out hona
pr valve sy itna khas fark nhi parta ha
ap valve ki setting karo jo valve silencers ki side pr ha
exhusa valve ki setting karo agar theak nhi hota to
ap cam new lagao
IN SHAA ALLAH
set ho jay ga
Yar half atomatic ki vedio h koi genrater kay
zia bahi jasco ka genrator 1.2 kv without self engine oil change kia th uss ka bad 5 minute chata hai or 1 sec ka lia white smoke data hai or smoke band ho jata hai oil kis grade ka genrator main dalna bata do plz
Sar Ek generator mein Shauk kholne per band ho ja rahi hai iska Kuchh solution bataen
EP 1000 generator carburettor setting speed kam Jyada Hoti Hai Air Screw set kaise kare
Generator ke switch ma car relay kasa lagata ha jis k zarya generator ko kahe or jaga sa pushbutton sa on karta ha
Mera generator bohut awaz kar raja hai gas bhi kha rahha hai bohut air start bhi late hota hai . me ne much din pehlay set kite that
block for generator 3.5 engin kitne ka hy
Asslam o allikum Zia bai
Bai jan muje 2.5 kva ka full tools batain plz jo easy ho use karne men mane ap ka course dekh liya he to men khud apne ganerator ka kam karon ga muqamal tool batai to men purchase karon shop se
Zia Bhai zabar dast video banae hai aap ka shop kyan pr hai
Assalam o Alaykum
Zia Bhai, New head install kia hay, lekin ab self bohat jam hogya hy, purany head pr bilkl sahi se self lag rha tha... Tappet bhi loose rakhe hein .. kya waja hoskti hy? Shukria
Apne head new install kya h tu kese pata chla tha apko k head khrb horaha h q k mujhe b machenic ne Kaha h k mere generator me head ki problem horahi h thori deir me generator off hojata h
@@muhammadkamran7924 yar valve gauge khtm hochuky thy, pressure nahi tha isi liye mene new head lagadia... Ab phir se 1 kick m start hojata hy
@@TheExcessivemhz Mera generator thori deir me bund hojata h tu me usi head ko bnwa lon ya new lekr lagaon kitne ka h
zia bhai menay speed bhi di hay or avr bh change karli current nhee araha . zia bhai stator men say jo wires arai hain kiya unkay connection samjha daingay ap ?
Bhai 1.2 kW ki bhi gauge itna hi hoga kya
What can cause the problem if the generator rope is hard to drag and the tapping was already set
Exhaust tappet too loose, tighten it by a bit
Sir Hamare genreter baar baar tepet rod se nikal gata .sir tel me about this problem
Ap tepet wala set new laga lo
100 tak ma mil jata ha
Zia Bhai mere generator ki speed change ni hoti ek Jaga ruk I rehti Hai Governor shaft ko hath se agay kro tb b ni hoti carburetor change krdia Phr b Thk ni hua Kia Masla hoskta ha usme
AoA zia bhai head gas kit top or Bottom m insulation tube lgana problem to ni krega???
Head ki gas kit ma tube ki zarorat nhi parti ha
Head ki gas kit moti hoti ha
Is lye jb head lagta ha to is ma gap ki koi gonjais nhi rhti ha
Shukria
Speed same rehti h Jb load daaalo to or Kam hojati Hai speed RPM badhte ni hn Kuch b krlo Gas per chalata Hu me gas kit B new laga K dekhli
پلگ والی تار میں کرنٹ نھیں اء رھا 5 کے وی ھے پورا انجن اءپ کی ویڈیو دیکھ کر بنا لیا ھے انجن میں پریشرھے
Jab Chauk Band Karke start kar raha hun Uske bad Chauk Khol raha hun to band ho ja rahi hai
Bhai yeh btao generator bilkul theak chal raha haagar ampare bohat lay raha hai
Zia Bhai Governor shaft Start hone k Bht dair bad Zara c move hoti Hai voltage 230 se 200 pe ajate hn load per
Ap governor new setting kr lo
Us k bad set ho jay ga
apnay switch connecton jesay batayr thay us tareekay say menay switch to set kardya wo ok hay. stator me say nikalnay waali wires ka nhee andaza mjhay .
ok ap mje mery WhatsApp pr wire ki pic send karo
ma dhkhta hn phr ap ko samjh dn ga connection ka
Bhai head se filter ki traf jo pipe jata he wo thora sa toot ker head k oper wale cover mai reh gaya he us mai double layer he agar ksi bhai ko malom he to plz mjhe bata de k wo kese baher nikal skte hn. Honda Generator he.
Ap us ki tens mat lo
Us ko engine pr koi fark nhi pary ga
Agar ap ko theak nhi lag rha ha to ap ye tappit cover he new le kar laga sakty ho
Salam.. Sir mene apne home generator K valve new banwa K lagaye To generator chal to raha hai lekin carburator ki chok band pe chal raha hai chok khol do to band ho jata hai.. ye kiya masla hai sir please bata den
Waalakumsalam
Uzair Ahmed Welcome to my youtube channal
Ap generator ko gas par chala rhy hn ??
agar gas par chala rhy hn to is ma 2 prbm hn gi
1st filter saaf nhi ho ga
ya
2nd gas kit sy gas kam pass ho rhe ho gi ya phr gas zyada pass ho rhe ho gi
agar ap petrol par chala rhy hn to phr ye prbm carburator ki safai na hony ki waja sy ha
Bhai honda gx 270 ki tapit ke gaze number kya hai
Kite mm hai
Zia bhai generator chowk py start hota hy but jese hi normal Karyn to band hojata hy plz guide
Faizi Ahmed Welcome to my UA-cam channal
Sorry ma busy tha is lye reply nhi kar saka tha
Ap mje whatsApp num par msg send kar deya karo
Only WhatsApp k lye num ha
+92 312 3902109
Agar gas par asa ho rha ha to ap filter ko saaf kar k lagao ya new filter lagao us k bad b asa ho to phr ap ko gas kit sy gas ka pressor thora sa zyada karna pary ga
Agar petrol par asa ho rha ha to ap carburator ki safai karo or filter ko b saaf kar k lagao ya new filter lagao is k bad set ho ga
Zia bhai aslam alikom genrator ki head ki andar do nat hi agar inmisi yek lose ho kya genretor start hoga?or hal kya hi
Wesy genrator chal jay ga
Agar presser theak rha to load aram sy chala le ga
Agar presser lek kar rha ho ga to ye ho ga k load full nhi uthy ga
Or is ka hal ye ha k new chori banwani parti ha
Lath waly sy
@@ZiaTvgenerator shokrya bhai
Assalam o alikum
Jo head k 4 nut hotay hain wo jis jga lgtay hain udr sy thread loss ho jai to wo new ban jatay hain or kidr sy?
Waalakumsalam
G bhai wo ban jaty hn
Or ye kam lath wala karta ha
Wo isi ne new thread bana de ga
@@ZiaTvgenerator lath kn?
lathe machine wala
Jo engine valve etc set kar k dety hn