How To Set Up ABB ACS355 AC Drive With A Standard Control Pad

Поділитися
Вставка
  • Опубліковано 25 гру 2024

КОМЕНТАРІ • 74

  • @leonardourlian2371
    @leonardourlian2371 3 роки тому +2

    Boa noite amigo eu tenho um ACS 355 220 v
    Instalado em um torno gostaria de saber se tem algum parâmetro que eu coloca pra aumentar o torque em baixas rotações

  • @AnkitPatel-mn1pv
    @AnkitPatel-mn1pv 2 роки тому +1

    How can I set torq parameters in the drive?

  • @santanainmexico
    @santanainmexico 7 років тому +1

    is possible to change the max/min input values for the analog input?

  • @nasardish4128
    @nasardish4128 5 років тому +2

    How to connect potentiolmeter &switch please vidio or diagram

  • @leonardourlian2371
    @leonardourlian2371 3 роки тому

    Good night friend I have an ACS 355 220 v
    Installed in a lathe I would like to know if there is any parameter that I use to increase the torque at low speeds.

  • @rami1612
    @rami1612 9 років тому

    In the settings here in video the drive follows the value u choose for "ref", will it work as variable frequency incase you use solar knowing that par 1103 is set to solar? thank you

    • @GalcoIndustrial
      @GalcoIndustrial  9 років тому

      Rami H The drive is still a variable frequency control, but when you set parameter 1103 to solar, the drive automatically adjusts the output frequency based on how much
      power the PV cells are producing. You cannot manually set the output frequency
      in this mode.

    • @rami1612
      @rami1612 9 років тому

      so wat i have to do with the "ref"? parameter 1103 already set to solar. and parameter 9904 is set on scalar frequency. could the problem be from the mitsubishi magnetic switch installed after the drive?

  • @أذكرالله-ف3ض
    @أذكرالله-ف3ض 4 роки тому

    How to connect the Abb ACS355 device to become automatic

  • @KAJEMIBNEARIF
    @KAJEMIBNEARIF 3 роки тому

    Reverse forward setting plz

  • @kalpeshhingu1195
    @kalpeshhingu1195 4 роки тому

    Dear sir. ABB ACS 800 Control display not start up. CDP 312 Penal V5. 30 showing

  • @KamalkannanK-c5k
    @KamalkannanK-c5k 17 днів тому

    Hi, we are using acs355-03e-12a5-4+n827 drive for solar pump.we encountered some unknown issue in the system.while on the switch, display getting on rotating with symbol.but after that there is changes in the display.

    • @KamalkannanK-c5k
      @KamalkannanK-c5k 17 днів тому

      After that there are no changes in the dusplay

    • @GalcoIndustrial
      @GalcoIndustrial  15 днів тому

      We will need to know what changes are happening to the display to begin to understand what could possibly be happening.
      The rotating symbol mentioned might be the symbol indicating that the drive is outputting current to the motor. It should be a rotating arrow that will either be spinning in the clockwise direction (representing forward movement of the motor) or the counterclockwise direction (representing reverse movement of the motor). Also, the line will be a dashed line until the drive reaches it reference point, then the line will become solid.
      please reach out if you have any further questions

    • @KamalkannanK-c5k
      @KamalkannanK-c5k 15 днів тому

      After switching on the system, it appears like the rotation I shared video earlier.what could be reasons for this type of display rotation.please suggest me how to proceed further.

    • @GalcoIndustrial
      @GalcoIndustrial  9 днів тому

      @@KamalkannanK-c5k please contact techsupport@galco.com or 800-575-5562 option 3 for further assistance

  • @epitome6991
    @epitome6991 5 років тому

    My abb acs355 showing fault f0004 plz help what should i do

  • @dilipsrinivas7149
    @dilipsrinivas7149 6 років тому

    Is there a way to run a 1 phase motor with ACS 355 drive ?

    • @GalcoIndustrial
      @GalcoIndustrial  6 років тому

      Generally speaking no. However we have run a single phase fractional HP motor on a VFD and it responded fairly well. You should also know that it was just a fan motor with no fan blade attached. Single phase motors are not intended to be run on a VFD. A Reduced Voltage Starter would be a more economical choice for a single phase application.

  • @Samsung-no8ff
    @Samsung-no8ff Рік тому

    What happens if F0028 fault appears on this screen

  • @arunbhatt5612
    @arunbhatt5612 7 років тому

    hii i want to set speed when i set it after 2 minuts stop abb 355...motor load 7.5

  • @tamilvanan1401
    @tamilvanan1401 5 років тому

    Rated frequency was 60hz at motor nameplate and same is set in the VFD but motor running condition frequency not increased more than 53hz ,can u tell what the problem

    • @GalcoIndustrial
      @GalcoIndustrial  5 років тому

      Most likely you have 1 of 2 potential problems. 1) Reference scaling; what are the settings in parameters 1103 to 1108. 2) The motor is at maximum load and the drive is in current limit.

  • @smallgoon
    @smallgoon 7 років тому

    How do we set the drive up for analog control from an analog input?

    • @GalcoIndustrial
      @GalcoIndustrial  7 років тому +1

      Simply wire up the speed pot to terminals 2, 3 and 4 on connector X1A. The drive is defaulted to this input. However you do have to make sure the drive is in remote mode. Look in the upper left corner of display on keypad to see if in remote, if not push the LOC/REM button to toggles modes.

  • @genbawindy
    @genbawindy 9 років тому

    I am setting a new parameter but when I press enter again it does not turn the paramater number back. How should I change the settings? is there a block setting to not change paramaters?

    • @GalcoIndustrial
      @GalcoIndustrial  9 років тому

      +Cengiz Oğuzer When you want to change a parameter using the standard keypad, once you select the
      parameter, you need to hold the ENTER button in for a few seconds until
      the word SET appears at the bottom of the display, next to the word PAR.
      Once you see this you can change the parameter to what you want, then push ENTER
      again to save it. You will need to do this each time you want to change a parameter.
      There is also a PARAMETER LOCK, parameter 1602, which prevents parameters frombeing changed from the keypad, this should be set to 1 which means
      unlocked. If it set to a 0, then it is locked and you need to go to
      parameter 1603 and enter 358 to unlock.

    • @genbawindy
      @genbawindy 9 років тому

      +GalcoTV Thank you very much. It was exactly how you described, it was locked. Now can change all.

  • @muaathe78
    @muaathe78 8 років тому

    Hi, may I ask what is the difference between ACS335 AND ACS150

    • @GalcoIndustrial
      @GalcoIndustrial  8 років тому

      +Muaathe Aziz the difference is power.
      The ACS355
      ◾0.37 to 22 kW/0.5 to 30 hp
      ◾Optimized design for cabinet installations saves space and installation time
      ◾Wide range of fieldbus adapters available offer flexible connectivity
      ◾Vector control capable of running both asynchronous motors and permanent magnet motors
      ◾Simple and visual sequence programming to make independent and repeatable operation sequences
      ◾Pre-defined application macros for quick basic setup
      ◾Unified height and depth of the IP20 product family simplifies wiring in cabinet installations
      The ACS150
      ◾Power range 0.37 to 4 kW/0.5 to 5 Hp
      ◾IP20 enclosure
      ◾Scalar control
      ◾Integrated user interface and potentiometer
      ◾Built-in brake chopper
      ◾Built-in EMC filter for 2nd environment

    • @brahimbrahim-ep7gd
      @brahimbrahim-ep7gd 4 роки тому

      I want to know this code F 0046

  • @MrSweetlove12
    @MrSweetlove12 7 років тому

    How to tke 24V from ACH550 drive?

    • @GalcoIndustrial
      @GalcoIndustrial  7 років тому

      Terminal 10 of the X1 connectors is +24volt output, terminal 11 is the 24volt common. If 11 and 12 jump together, then connect each digital input to the + output to activate each input.

  • @ameeralthalam1306
    @ameeralthalam1306 3 роки тому

    How i can buy one
    ACS150-01E-09A8-2
    2.2kw 3ph
    Input 220v
    Output 3 phase
    Me from iraq .. i need one .. How much with arrive to iraq ?

  • @miukumara9918
    @miukumara9918 7 років тому

    my abb acs 550 show in error not responding device,please guide me to correct it

    • @GalcoIndustrial
      @GalcoIndustrial  7 років тому

      OK well first of all what fault is it showing on display, or is there no power?

    • @miukumara9918
      @miukumara9918 7 років тому

      GalcoTV

    • @miukumara9918
      @miukumara9918 7 років тому

      before its shows fault code 29

    • @miukumara9918
      @miukumara9918 7 років тому

      now its shows "device not responding "

  • @rudyiskandarabubakar9362
    @rudyiskandarabubakar9362 9 років тому

    i'm getting fault F0035.What is wrong with it?

    • @GalcoIndustrial
      @GalcoIndustrial  9 років тому

      Rudy Iskandar
      Fault 0035 is OUTPUT WIRING, which according to the manual, the most common cause is
      the input power wires are connected the drive output. The input power wire should be connected to terminalsU1, V1 & W1 and the motor wires should be connected to terminals U2, V2 & W2.
      The other possibility per the manual is “Fault can be declared if the input poweris delta grounded system and motor cable capacitance is large.”

    • @mirarsheed2275
      @mirarsheed2275 6 років тому

      My fault is f0001. Please help

  • @norfazlimokri3598
    @norfazlimokri3598 6 років тому

    Why the voltage output just only reach 160v to 170v, how to set up the voltage back to 240v? The input voltage is 240v....anyone please advice...

    • @GalcoIndustrial
      @GalcoIndustrial  6 років тому

      Are you running at 60Hz? What are you measuring the voltage with?

    • @norfazlimokri3598
      @norfazlimokri3598 6 років тому

      Measuring by multimeter...the out put cameout with 150V

    • @Shorts.shorts.326
      @Shorts.shorts.326 5 років тому

      @@norfazlimokri3598 you will not get a correct voltage reading using a multimeter as it varies the frequency and torque in various startup and running stage

  • @brahimbrahim-ep7gd
    @brahimbrahim-ep7gd 4 роки тому

    I want to know this code F 0046

  • @baburaoalagundi2812
    @baburaoalagundi2812 5 років тому

    How sett RPM from Hz

    • @GalcoIndustrial
      @GalcoIndustrial  5 років тому

      It depends on which control mode you have selected in parameter 9904, SCALAR FREQ displays Hz, VECTOR SPEED or VECTOR TORQUE will read out in RPM.

  • @fairose1052
    @fairose1052 5 років тому

    I get alarm on display a20 10 what ll do

    • @GalcoIndustrial
      @GalcoIndustrial  5 років тому

      Here's what I found for your scenario, Motor temperature is
      too high (or appears to be too high) due to excessive load, insufficient motor power, inadequate cooling or incorrect start-up data.

    • @fairose1052
      @fairose1052 5 років тому

      @@GalcoIndustrial thanks for ur reply.
      How to reset the drive.

    • @GalcoIndustrial
      @GalcoIndustrial  5 років тому +1

      @@fairose1052 your welcome. Please don't hesitate to ask any additional questions, and let us know how it went.

    • @fairose1052
      @fairose1052 5 років тому

      @@GalcoIndustrial how to remove this alarm A 2010

  • @arunbhatt5612
    @arunbhatt5612 7 років тому

    abb acs 355 or 350 difference

  • @narayanadhikari3230
    @narayanadhikari3230 9 років тому

    Acs 355 drive show on monitar fault f1009

    • @GalcoIndustrial
      @GalcoIndustrial  9 років тому

      Narayan Adhikari If you're getting a fault 1009, it could be that the settings for parameter 9907 (Motor Nominal Frequency) or 9908 (Motor Nominal Speed) are incorrect. Recheck your nameplate to see if they match.

    • @mosesmfalanyombo7721
      @mosesmfalanyombo7721 8 років тому

      ACS550 DRIVE show a fault F0021,what is a solution?

    • @GalcoIndustrial
      @GalcoIndustrial  8 років тому

      Moses Mfalanyombo The manual says “Internal fault. Current measurement is out of range.”, this says that the drive is defective, you can try a couple of tests to confirm this.
      If you can run the drive and measure the current going to the motor and compare it to parameter number 0104, which is current. If there is a big difference between them, you have a problem with the drive. If they are the same, compare that value to the full load amps of the motor, if it is higher, you may have a motor on load issue.
      If you can’t run the drive, disconnect the motor and try to run it again. If it still faults, you have a problem with the drive. If it runs with the motor disconnected, look at parameter number 0104, it should be zero. If the value is not close to zero, you have a drive problem. If it is close to zero, you may have a motor or load issue. Try reconnecting the motor without the load connected to it and see if the drive faults. If it does, check your motor, if it doesn’t, check your load.

    • @Shorts.shorts.326
      @Shorts.shorts.326 5 років тому

      @@GalcoIndustrial either motor coil burned or Inverter failed

  • @ปราการสารีศรี

    ขอภาษาไทยใด้มั้ยครับ

  • @govindrajuyamparala787
    @govindrajuyamparala787 6 років тому

    How to reset

    • @GalcoIndustrial
      @GalcoIndustrial  6 років тому

      Use the stop button or cycle power to it.

    • @MohdNazim-xe3xv
      @MohdNazim-xe3xv 6 років тому

      @@GalcoIndustrial I need your WhatsApp no. I asked about abb drive
      That's my WhatsApp number. +919458547118

  • @ajazhaider5866
    @ajazhaider5866 7 років тому

    my drive show error 2010

    • @GalcoIndustrial
      @GalcoIndustrial  7 років тому

      This is a motor overtemp fault. Check the load on the motor, check the fan is not broken or block air flow. Running at low speeds for long periods of time can overheat the motor. If this doesn't help give us a call at 800-337-1720 and ask for an ABB product manager to assist you.

    • @Shorts.shorts.326
      @Shorts.shorts.326 5 років тому

      @@GalcoIndustrial also may be the the invertor temperature sensor damage

  • @ajazhaider5866
    @ajazhaider5866 7 років тому

    but I install a new

    • @GalcoIndustrial
      @GalcoIndustrial  7 років тому

      Then double check the group 99 parameters for correct motor data entered if you haven't already. This may not be a drive issue, the motor is getting to hot not the drive. Are you running at low speeds?

  • @ممحمدراضىنظرةمداللطاقهالشمسيه

    هل يوجد برمجه بالعربيه

    • @ameeralthalam1306
      @ameeralthalam1306 3 роки тому

      اتعبني البحث عن برمجه بالعربي ... لكانت المهمه اسهل
      المشكله ان الكتلوك غير معرب ايضا ...وحتما الوقوع في اخطاء

  • @v.gowthamgs7571
    @v.gowthamgs7571 4 роки тому

    Language problem ... explain tamil

  • @majiiidsaber7804
    @majiiidsaber7804 2 роки тому

    درد و بلات بخوره تو سر جو بایدن .