Boa noite amigo eu tenho um ACS 355 220 v Instalado em um torno gostaria de saber se tem algum parâmetro que eu coloca pra aumentar o torque em baixas rotações
Good night friend I have an ACS 355 220 v Installed in a lathe I would like to know if there is any parameter that I use to increase the torque at low speeds.
In the settings here in video the drive follows the value u choose for "ref", will it work as variable frequency incase you use solar knowing that par 1103 is set to solar? thank you
Rami H The drive is still a variable frequency control, but when you set parameter 1103 to solar, the drive automatically adjusts the output frequency based on how much power the PV cells are producing. You cannot manually set the output frequency in this mode.
so wat i have to do with the "ref"? parameter 1103 already set to solar. and parameter 9904 is set on scalar frequency. could the problem be from the mitsubishi magnetic switch installed after the drive?
Hi, we are using acs355-03e-12a5-4+n827 drive for solar pump.we encountered some unknown issue in the system.while on the switch, display getting on rotating with symbol.but after that there is changes in the display.
We will need to know what changes are happening to the display to begin to understand what could possibly be happening. The rotating symbol mentioned might be the symbol indicating that the drive is outputting current to the motor. It should be a rotating arrow that will either be spinning in the clockwise direction (representing forward movement of the motor) or the counterclockwise direction (representing reverse movement of the motor). Also, the line will be a dashed line until the drive reaches it reference point, then the line will become solid. please reach out if you have any further questions
After switching on the system, it appears like the rotation I shared video earlier.what could be reasons for this type of display rotation.please suggest me how to proceed further.
Generally speaking no. However we have run a single phase fractional HP motor on a VFD and it responded fairly well. You should also know that it was just a fan motor with no fan blade attached. Single phase motors are not intended to be run on a VFD. A Reduced Voltage Starter would be a more economical choice for a single phase application.
Rated frequency was 60hz at motor nameplate and same is set in the VFD but motor running condition frequency not increased more than 53hz ,can u tell what the problem
Most likely you have 1 of 2 potential problems. 1) Reference scaling; what are the settings in parameters 1103 to 1108. 2) The motor is at maximum load and the drive is in current limit.
Simply wire up the speed pot to terminals 2, 3 and 4 on connector X1A. The drive is defaulted to this input. However you do have to make sure the drive is in remote mode. Look in the upper left corner of display on keypad to see if in remote, if not push the LOC/REM button to toggles modes.
I am setting a new parameter but when I press enter again it does not turn the paramater number back. How should I change the settings? is there a block setting to not change paramaters?
+Cengiz Oğuzer When you want to change a parameter using the standard keypad, once you select the parameter, you need to hold the ENTER button in for a few seconds until the word SET appears at the bottom of the display, next to the word PAR. Once you see this you can change the parameter to what you want, then push ENTER again to save it. You will need to do this each time you want to change a parameter. There is also a PARAMETER LOCK, parameter 1602, which prevents parameters frombeing changed from the keypad, this should be set to 1 which means unlocked. If it set to a 0, then it is locked and you need to go to parameter 1603 and enter 358 to unlock.
+Muaathe Aziz the difference is power. The ACS355 ◾0.37 to 22 kW/0.5 to 30 hp ◾Optimized design for cabinet installations saves space and installation time ◾Wide range of fieldbus adapters available offer flexible connectivity ◾Vector control capable of running both asynchronous motors and permanent magnet motors ◾Simple and visual sequence programming to make independent and repeatable operation sequences ◾Pre-defined application macros for quick basic setup ◾Unified height and depth of the IP20 product family simplifies wiring in cabinet installations The ACS150 ◾Power range 0.37 to 4 kW/0.5 to 5 Hp ◾IP20 enclosure ◾Scalar control ◾Integrated user interface and potentiometer ◾Built-in brake chopper ◾Built-in EMC filter for 2nd environment
Terminal 10 of the X1 connectors is +24volt output, terminal 11 is the 24volt common. If 11 and 12 jump together, then connect each digital input to the + output to activate each input.
Rudy Iskandar Fault 0035 is OUTPUT WIRING, which according to the manual, the most common cause is the input power wires are connected the drive output. The input power wire should be connected to terminalsU1, V1 & W1 and the motor wires should be connected to terminals U2, V2 & W2. The other possibility per the manual is “Fault can be declared if the input poweris delta grounded system and motor cable capacitance is large.”
@@norfazlimokri3598 you will not get a correct voltage reading using a multimeter as it varies the frequency and torque in various startup and running stage
Here's what I found for your scenario, Motor temperature is too high (or appears to be too high) due to excessive load, insufficient motor power, inadequate cooling or incorrect start-up data.
Narayan Adhikari If you're getting a fault 1009, it could be that the settings for parameter 9907 (Motor Nominal Frequency) or 9908 (Motor Nominal Speed) are incorrect. Recheck your nameplate to see if they match.
Moses Mfalanyombo The manual says “Internal fault. Current measurement is out of range.”, this says that the drive is defective, you can try a couple of tests to confirm this. If you can run the drive and measure the current going to the motor and compare it to parameter number 0104, which is current. If there is a big difference between them, you have a problem with the drive. If they are the same, compare that value to the full load amps of the motor, if it is higher, you may have a motor on load issue. If you can’t run the drive, disconnect the motor and try to run it again. If it still faults, you have a problem with the drive. If it runs with the motor disconnected, look at parameter number 0104, it should be zero. If the value is not close to zero, you have a drive problem. If it is close to zero, you may have a motor or load issue. Try reconnecting the motor without the load connected to it and see if the drive faults. If it does, check your motor, if it doesn’t, check your load.
This is a motor overtemp fault. Check the load on the motor, check the fan is not broken or block air flow. Running at low speeds for long periods of time can overheat the motor. If this doesn't help give us a call at 800-337-1720 and ask for an ABB product manager to assist you.
Then double check the group 99 parameters for correct motor data entered if you haven't already. This may not be a drive issue, the motor is getting to hot not the drive. Are you running at low speeds?
Boa noite amigo eu tenho um ACS 355 220 v
Instalado em um torno gostaria de saber se tem algum parâmetro que eu coloca pra aumentar o torque em baixas rotações
How can I set torq parameters in the drive?
is possible to change the max/min input values for the analog input?
How to connect potentiolmeter &switch please vidio or diagram
Good night friend I have an ACS 355 220 v
Installed in a lathe I would like to know if there is any parameter that I use to increase the torque at low speeds.
In the settings here in video the drive follows the value u choose for "ref", will it work as variable frequency incase you use solar knowing that par 1103 is set to solar? thank you
Rami H The drive is still a variable frequency control, but when you set parameter 1103 to solar, the drive automatically adjusts the output frequency based on how much
power the PV cells are producing. You cannot manually set the output frequency
in this mode.
so wat i have to do with the "ref"? parameter 1103 already set to solar. and parameter 9904 is set on scalar frequency. could the problem be from the mitsubishi magnetic switch installed after the drive?
How to connect the Abb ACS355 device to become automatic
Reverse forward setting plz
Dear sir. ABB ACS 800 Control display not start up. CDP 312 Penal V5. 30 showing
Hi, we are using acs355-03e-12a5-4+n827 drive for solar pump.we encountered some unknown issue in the system.while on the switch, display getting on rotating with symbol.but after that there is changes in the display.
After that there are no changes in the dusplay
We will need to know what changes are happening to the display to begin to understand what could possibly be happening.
The rotating symbol mentioned might be the symbol indicating that the drive is outputting current to the motor. It should be a rotating arrow that will either be spinning in the clockwise direction (representing forward movement of the motor) or the counterclockwise direction (representing reverse movement of the motor). Also, the line will be a dashed line until the drive reaches it reference point, then the line will become solid.
please reach out if you have any further questions
After switching on the system, it appears like the rotation I shared video earlier.what could be reasons for this type of display rotation.please suggest me how to proceed further.
@@KamalkannanK-c5k please contact techsupport@galco.com or 800-575-5562 option 3 for further assistance
My abb acs355 showing fault f0004 plz help what should i do
Is there a way to run a 1 phase motor with ACS 355 drive ?
Generally speaking no. However we have run a single phase fractional HP motor on a VFD and it responded fairly well. You should also know that it was just a fan motor with no fan blade attached. Single phase motors are not intended to be run on a VFD. A Reduced Voltage Starter would be a more economical choice for a single phase application.
What happens if F0028 fault appears on this screen
hii i want to set speed when i set it after 2 minuts stop abb 355...motor load 7.5
Rated frequency was 60hz at motor nameplate and same is set in the VFD but motor running condition frequency not increased more than 53hz ,can u tell what the problem
Most likely you have 1 of 2 potential problems. 1) Reference scaling; what are the settings in parameters 1103 to 1108. 2) The motor is at maximum load and the drive is in current limit.
How do we set the drive up for analog control from an analog input?
Simply wire up the speed pot to terminals 2, 3 and 4 on connector X1A. The drive is defaulted to this input. However you do have to make sure the drive is in remote mode. Look in the upper left corner of display on keypad to see if in remote, if not push the LOC/REM button to toggles modes.
I am setting a new parameter but when I press enter again it does not turn the paramater number back. How should I change the settings? is there a block setting to not change paramaters?
+Cengiz Oğuzer When you want to change a parameter using the standard keypad, once you select the
parameter, you need to hold the ENTER button in for a few seconds until
the word SET appears at the bottom of the display, next to the word PAR.
Once you see this you can change the parameter to what you want, then push ENTER
again to save it. You will need to do this each time you want to change a parameter.
There is also a PARAMETER LOCK, parameter 1602, which prevents parameters frombeing changed from the keypad, this should be set to 1 which means
unlocked. If it set to a 0, then it is locked and you need to go to
parameter 1603 and enter 358 to unlock.
+GalcoTV Thank you very much. It was exactly how you described, it was locked. Now can change all.
Hi, may I ask what is the difference between ACS335 AND ACS150
+Muaathe Aziz the difference is power.
The ACS355
◾0.37 to 22 kW/0.5 to 30 hp
◾Optimized design for cabinet installations saves space and installation time
◾Wide range of fieldbus adapters available offer flexible connectivity
◾Vector control capable of running both asynchronous motors and permanent magnet motors
◾Simple and visual sequence programming to make independent and repeatable operation sequences
◾Pre-defined application macros for quick basic setup
◾Unified height and depth of the IP20 product family simplifies wiring in cabinet installations
The ACS150
◾Power range 0.37 to 4 kW/0.5 to 5 Hp
◾IP20 enclosure
◾Scalar control
◾Integrated user interface and potentiometer
◾Built-in brake chopper
◾Built-in EMC filter for 2nd environment
I want to know this code F 0046
How to tke 24V from ACH550 drive?
Terminal 10 of the X1 connectors is +24volt output, terminal 11 is the 24volt common. If 11 and 12 jump together, then connect each digital input to the + output to activate each input.
How i can buy one
ACS150-01E-09A8-2
2.2kw 3ph
Input 220v
Output 3 phase
Me from iraq .. i need one .. How much with arrive to iraq ?
my abb acs 550 show in error not responding device,please guide me to correct it
OK well first of all what fault is it showing on display, or is there no power?
GalcoTV
before its shows fault code 29
now its shows "device not responding "
i'm getting fault F0035.What is wrong with it?
Rudy Iskandar
Fault 0035 is OUTPUT WIRING, which according to the manual, the most common cause is
the input power wires are connected the drive output. The input power wire should be connected to terminalsU1, V1 & W1 and the motor wires should be connected to terminals U2, V2 & W2.
The other possibility per the manual is “Fault can be declared if the input poweris delta grounded system and motor cable capacitance is large.”
My fault is f0001. Please help
Why the voltage output just only reach 160v to 170v, how to set up the voltage back to 240v? The input voltage is 240v....anyone please advice...
Are you running at 60Hz? What are you measuring the voltage with?
Measuring by multimeter...the out put cameout with 150V
@@norfazlimokri3598 you will not get a correct voltage reading using a multimeter as it varies the frequency and torque in various startup and running stage
I want to know this code F 0046
How sett RPM from Hz
It depends on which control mode you have selected in parameter 9904, SCALAR FREQ displays Hz, VECTOR SPEED or VECTOR TORQUE will read out in RPM.
I get alarm on display a20 10 what ll do
Here's what I found for your scenario, Motor temperature is
too high (or appears to be too high) due to excessive load, insufficient motor power, inadequate cooling or incorrect start-up data.
@@GalcoIndustrial thanks for ur reply.
How to reset the drive.
@@fairose1052 your welcome. Please don't hesitate to ask any additional questions, and let us know how it went.
@@GalcoIndustrial how to remove this alarm A 2010
abb acs 355 or 350 difference
Acs 355 drive show on monitar fault f1009
Narayan Adhikari If you're getting a fault 1009, it could be that the settings for parameter 9907 (Motor Nominal Frequency) or 9908 (Motor Nominal Speed) are incorrect. Recheck your nameplate to see if they match.
ACS550 DRIVE show a fault F0021,what is a solution?
Moses Mfalanyombo The manual says “Internal fault. Current measurement is out of range.”, this says that the drive is defective, you can try a couple of tests to confirm this.
If you can run the drive and measure the current going to the motor and compare it to parameter number 0104, which is current. If there is a big difference between them, you have a problem with the drive. If they are the same, compare that value to the full load amps of the motor, if it is higher, you may have a motor on load issue.
If you can’t run the drive, disconnect the motor and try to run it again. If it still faults, you have a problem with the drive. If it runs with the motor disconnected, look at parameter number 0104, it should be zero. If the value is not close to zero, you have a drive problem. If it is close to zero, you may have a motor or load issue. Try reconnecting the motor without the load connected to it and see if the drive faults. If it does, check your motor, if it doesn’t, check your load.
@@GalcoIndustrial either motor coil burned or Inverter failed
ขอภาษาไทยใด้มั้ยครับ
How to reset
Use the stop button or cycle power to it.
@@GalcoIndustrial I need your WhatsApp no. I asked about abb drive
That's my WhatsApp number. +919458547118
my drive show error 2010
This is a motor overtemp fault. Check the load on the motor, check the fan is not broken or block air flow. Running at low speeds for long periods of time can overheat the motor. If this doesn't help give us a call at 800-337-1720 and ask for an ABB product manager to assist you.
@@GalcoIndustrial also may be the the invertor temperature sensor damage
but I install a new
Then double check the group 99 parameters for correct motor data entered if you haven't already. This may not be a drive issue, the motor is getting to hot not the drive. Are you running at low speeds?
هل يوجد برمجه بالعربيه
اتعبني البحث عن برمجه بالعربي ... لكانت المهمه اسهل
المشكله ان الكتلوك غير معرب ايضا ...وحتما الوقوع في اخطاء
Language problem ... explain tamil
درد و بلات بخوره تو سر جو بایدن .