Thank you Sir. But how to plot by make x-axis is Varray and y-axis is Iarray or Parray like in this video. I have tried but the x-axis still in time series. Can you show the method? Thank you
Sorry I missed this point in this video. Thanks for highlighting. You can change the x-axis in the Simview or Graphs window. Search for 'Axis' tab at the top of Simview window. Then select: Axis -> Choose X-axis Variable -> In the dropdown list choose VArray.
It is required when you are simulating shading conditions. If you are working with uniform irradiation, then it is not required. It doesn't have anything to do with PSIM.
@@ahsanmehmood9229 Thank you sir for answering my question. I am trying to simulate the condition when PV system is shading so could you help me with those data of the bypass diode?
In the event of partial shading,how can I add methods to mitigate shading such as bypass diode or a micro inverter and check the different outputs using the software?
Sir you have used no of cell as 36 but in the data sheet that you have shown in the video has no of cell 72 ,in case of 36 cell array the efficiency of cell is coming out to be 35%. So how we can get 300 W Power with 36 cell?
That is a mistake...Number of cells should be 72. You can adjust resistance parameter to adjust maximum power as I have also explained this in the video.
@@ahsanmehmood9229 i made a multilevel inverter with a battery source on psim working, then i replaced the battery with PV + capacitor and the diode also worked
i wanna ask something, i can't press the 'Solar Module (Physical Model)' in utilities in PSIM. can you explain why and can you give me a solution for solve the problem? thanks
@@ahsanmehmood9229 okay thankyou sir. anyway why do you use a capacitor as a load in your system? is there possible to use a resistor as a load in the pv array simulation?
Can you do a video on how to change the irradiance, temperature, and load automatically with the simulation time.... Like at t=1 i=800 t=27 load =200 At t=2 i= 500. T=32 load=50 Automatically
Thank you Sir. But how to plot by make x-axis is Varray and y-axis is Iarray or Parray like in this video. I have tried but the x-axis still in time series. Can you show the method? Thank you
Sorry I missed this point in this video. Thanks for highlighting.
You can change the x-axis in the Simview or Graphs window. Search for 'Axis' tab at the top of Simview window. Then select: Axis -> Choose X-axis Variable -> In the dropdown list choose VArray.
Why is the current and power becoming 0 after 2 sec of simulation? Is it a series configuration?
AOA SIr,
How a voltmeter is measuring Power and Current of the Output?
Can you fo a simulation of a boost converter using incremental conductance in psim
Sure!
Hello sir, I want to ask why when I simulate 50 solar cells the application will close automatically? Can you give me a tutorial?
Sir, I would like to ask about your bypass diode parameter since I can't find any information Psim diode require to insert. Thank u, sir
It is required when you are simulating shading conditions. If you are working with uniform irradiation, then it is not required. It doesn't have anything to do with PSIM.
@@ahsanmehmood9229 Thank you sir for answering my question. I am trying to simulate the condition when PV system is shading so could you help me with those data of the bypass diode?
The method to create partial shading in PSIM is given in this video. Just watch the video carefully.
In the event of partial shading,how can I add methods to mitigate shading such as bypass diode or a micro inverter and check the different outputs using the software?
Watch my other videos, maybe you could find your answer.
How did you choosed the value of Capacitor?
Randomly.
There is no science behind it.
You can choose any value.
thank you very much for sharing
sir where to find that electrical characteristics datasheet
From Google, by writing the model name of real solar panel you are using.
Sir in my psim software I am unable to click on solar modules physical system
Download and install cracked/registered version of PSIM from internet.
Excellent. Can you demonstrate how P&O gets trapped in local minima
Sure!
Sir you have used no of cell as 36 but in the data sheet that you have shown in the video has no of cell 72 ,in case of 36 cell array the efficiency of cell is coming out to be 35%. So how we can get 300 W Power with 36 cell?
That is a mistake...Number of cells should be 72.
You can adjust resistance parameter to adjust maximum power as I have also explained this in the video.
sir, why there is no outpun in my psim simulation?
Have a cracked version of PSIM.
@@ahsanmehmood9229 i made a multilevel inverter with a battery source on psim working, then i replaced the battery with PV + capacitor and the diode also worked
but when i remove the capacitor and diode on the PV, there is no output
why sir?
does it really have to be capacitors and diodes on PV
i wanna ask something, i can't press the 'Solar Module (Physical Model)' in utilities in PSIM. can you explain why and can you give me a solution for solve the problem? thanks
Do you have a registered version of PSIM?
@@ahsanmehmood9229 i think i have the demo one
You need to install registered version.
@@ahsanmehmood9229 okay thankyou sir. anyway why do you use a capacitor as a load in your system? is there possible to use a resistor as a load in the pv array simulation?
Capacitor has been used only for I-V curve scanning. If you don't need I-V curve, then you can use any other load.
Can you do a video on how to change the irradiance, temperature, and load automatically with the simulation time....
Like at t=1 i=800 t=27 load =200
At t=2 i= 500. T=32 load=50
Automatically
Sure, but it will take few days.
@@ahsanmehmood9229 ok
Video has been been uploaded.
Can you please give me this simulation file
You can follow the steps mentioned in the video to create your own file.
Dear Sir I need our help in Fault detection in PV array. Sir can you provide me your email?