  • @MrHeHim
    @MrHeHim 2 роки тому +4

    Should note, many of those UPS's aren't built for sustained loads longer than the battery they come with can do. Reason is because most come without fans for cooling.. but! yeah, i would still probably do this for fun too. Just be safe 🙂

  • @KuntalGhosh
    @KuntalGhosh 2 роки тому +4

    This looks like a 600va ups so it should draw some 350-400w from the battery at full load and that equals around 30amp. So i hope u have atleast 15ah of Lifepo4 cells to sustain the discharge and add a fan cus this new battery will run this ups for much longer than the older leadacid so it will heat up a lot and might die.

    • @VippoTech
      @VippoTech  2 роки тому

      No it's just 150w ups

    • @KuntalGhosh
      @KuntalGhosh 2 роки тому +1

      @@VippoTech it says 360w/600va right on the sticker 😂

    • @manurkgs
      @manurkgs 2 роки тому +2

      @@VippoTech No.. normal desktop computer UPS is 360watts..i think, you don the experiment in 360 watt (500/600va) ups..🙏. By the way, you didn't revealed the result!! The back-up time, the charging etc .

    • @EmilePolka
      @EmilePolka 2 роки тому +1

      while this is true but some UPS actually have a hard limit of their uptime regardless of the battery charge level. majority of entry level APC UPS have a hardlimit of 15mins uptime even if the battery's charge is still good. I know these because my APC UPS basicalyl just refuse to turn on for at least 30minutes after it shutoff from battery mode even if the battery is barely discharged.
      though some APC UPS dont have this limit on some of their UPS designed for router modem and landline usage, also almost all UPS with external battery support dont have uptime limit, but to be honest these UPS have robust circuitry and fan builtin anyway.
      so yes, as long as your using APC UPS, you will be fine. Else, cheap UPS from market should take caution using this kind of battery.

    • @KuntalGhosh
      @KuntalGhosh Рік тому

      ​@@EmilePolkai am using 12ah 25.6v pack in br1000g-in and it runs it as long as the battery is above 21v. 300w load runs for 50min. That model of ups is made for external battery & can run pretty much indefinitely because it uses a totally different smps type inverter that runs cooler and have proper heatsink.
      I tried this battery on a bx1100 and at 100w it ran for 3hours. At 600w it ran for 5mins before the transformer melted and i had to cutopen the transformer to replace the thermal fuse. It works at 300w for 45min and the ups does not shut off after set time. And it is one of the cheaper 600w ups's although i do not recommend buying one.
      I bought that for 6000₹ new and it was a waste of money, with original battery it could not run my pc at idle for more than 15mins & while gaming it would give up after 2mins which is not enough to exit game and shut down.
      I bought the br1000g from a used scrap dealer for 2000₹ without battery. It has some scratches but it was working fine . I cleaned it up and made this Lifepo4 pack with 16 6000mah cells. Now at idle i can use the pc for over 2hours. And while gaming it goes for more than 40mins which is enough to even finish the game and average power cut in kolkata does not even last for 30mins. So 12ah is the sweet spot. The cells were 5000₹ from robu back in 2021. It has been running for 2 years now & have not lost a single minute of backup time. The bx1100 now powers router onu and tv with another 12ah 25.6v Lifepo4 pack. It runs the tv for over 4 hours. Lifepo4 is a game changer and cheaper than leadacid. It should be more popular.

  • @satyajitO3Wall
    @satyajitO3Wall Рік тому +6

    Lead Acid full charge resting voltage is 12.8V, while 4S LiFePO4 full charge resting voltage is 13.6V.
    Now does this UPS charge the LiFePO4 battery fully to 13.6V, or it will stop charging when it detects that the battery has reached 12.8V?
    In your video there is no connection between the BMS and UPS, so the UPS still thinks that the battery it is connected to is a LEAD ACID battery. It will not fully charge your LiFePO4 battery to it's max capacity of 13.6V.

    • @VippoTech
      @VippoTech  Рік тому

      Check inverter specs
      It will 14.4v
      Not 13.6

  • @ryoheilui1639
    @ryoheilui1639 Рік тому +1

    why does voltage drop from 13.5 v to 13.1 v in less than 10 minutes when I am discharging the UPS with only 50w load? what volts appear on your end while using the UPS battery

    • @VippoTech
      @VippoTech  Рік тому

      It's because your battery pack be unbalanced

  • @dondattler7085
    @dondattler7085 Рік тому +1

    I'm Not a fan of wrapping my Lifepo4s or Li-Ions, due to lack of cooling. But if this is a low amp/watt ups It should be fine! I also like to have a little space between the cells, also for cooling.

    • @VippoTech
      @VippoTech  Рік тому +1

      This is very low power ups
      And you are absolutely right 👍

  • @MrRajeevsundar
    @MrRajeevsundar 2 роки тому +2

    ls it meant for duff & Dump technicians ?

    • @VippoTech
      @VippoTech  2 роки тому

      Thanks for your such valuable complement

  • @patelvimal3591
    @patelvimal3591 Рік тому +1

    I tried the same but got one problem, my ups works normally on this battery if its already on and give backup after power cut, but if there is already power cut from grid then i can not start the ups iven if battery is fully charged.
    I need grid power to wakeup the ups
    I dont understand this problem help me

    • @GAMING.CHHORA.2010
      @GAMING.CHHORA.2010 Місяць тому

      The ups will not turn on when there's is no grid try removing cables from behind of ups it doesn't start on load without grid

    • @patelvimal3591
      @patelvimal3591 Місяць тому

      @@GAMING.CHHORA.2010 the other ups of same brand is turning on with battery without grid supply, nd recently i uodate the ups with lithium phosphate and sometimes it turns on without grid and sometimes it need grid power of 3 to 4 minute before turning on, then it works normally.

  • @ayanthegreat1462
    @ayanthegreat1462 2 роки тому +2

    Full charge open circuit voltage of this battery?

  • @spruzzo_man
    @spruzzo_man 2 роки тому +1

    Hi, I have similar UPS, my answare is this: can I replace the lead battery with similar Lion battery that it have BMS circuit inside?

    • @VippoTech
      @VippoTech  2 роки тому

      Offcourse

    • @Mnkmnkmnk
      @Mnkmnkmnk Рік тому +1

      You can't replace with Liion batteries because the voltage is quite different. LiFePo4 batteries are the only sort-of suitable drop-in replacement for 12v lead acid batteries.

  • @vijaydas9747
    @vijaydas9747 Рік тому +1

    is it still working

  • @Scat.original
    @Scat.original 9 місяців тому +1

    Excellent, Thank you

  • @swapniljoshi9997
    @swapniljoshi9997 2 роки тому +3

    BMS ampere?

  • @KyawLynnTun
    @KyawLynnTun 10 місяців тому +1

    LifePo4 external charger is better in this and you should install exhaust fan to release heat

  • @manojevtechnology
    @manojevtechnology 2 роки тому +1

    UPS inverter change karana padega ya nahi ?

    • @VippoTech
      @VippoTech  2 роки тому

      Nhi krna padega

    • @rajeshkannoly
      @rajeshkannoly 2 роки тому

      Tho low voltage cut off hogaya tho kese kaam karega...
      Reset switch lagaana padega na ?

    • @KuntalGhosh
      @KuntalGhosh 2 роки тому

      @@rajeshkannoly no. When the ups is plugged in it will provide some voltage initially to the bms and that will activate it. But the problem is ups might fail the self test period when battery is fully discharged. So in this sort of application it's better to not use a bms and only use a cell balancer..let the ups handle cutoff voltage of charge and discharge cycle. And use apc ups they have good charge and discharge controller. I have one 20yr old 500va apc unit still running 24x7 since day one and it has never once puffed any battery. From the original csb to currently a cheap frontech battery. I replace the battery every 2-3yr .. and now planning on 12ah or 18ah Lifepo4 replacement.

  • @Jobinfo4u
    @Jobinfo4u 2 роки тому +1

    Bms kitne ampere ka hai?

  • @debjit4418
    @debjit4418 Рік тому +2

    Absolutely not poasible for apc ups... i have change my battrry with 12 vlt 18mah battery. When battery drain it gives good back up..but during off load when battery charging ups chaging ling get red and tak tak sound comes constantly and chaging light comes to red and green after 8 sec constantly... when battry full charged this apc ups acting like something suspicuous... so i could not run lifepo4 12 volt battery to apc ups ..i need lead acid only...

  • @alloutmotivation8289
    @alloutmotivation8289 2 роки тому +1

    Sir mujhe v same battery chahiye ups ke liye. With old battery

  • @birmal_brian_344
    @birmal_brian_344 Рік тому +1

    Sir hm bhi 12v 12ah ka battery lagaye but Mera ups sayad charge nhi kr pa raha he..
    Ek bar charge khatam ho jane ke bad wo band ho jata he aur charge bhi nhi leta ..
    Ab kya kare..?

    • @VippoTech
      @VippoTech  Рік тому

      Disconnect kar do
      Phir reconnect karna chalu ho jayega

    • @birmal_brian_344
      @birmal_brian_344 Рік тому

      @@VippoTech LiFePO4 battery he, fir bhi reconnect krne se bhi charge nhi kr pa raha h..
      transformer ka charging capacity badhana hoga kya..?
      Pichla battery 12v 7.4ah lead acid ka tha..

    • @AvinashVSharma
      @AvinashVSharma Рік тому

      It needs minimum 4amp current to charge the lithium Iron battery. That is the reason it is not charging it

  • @anushkaaneek07
    @anushkaaneek07 2 роки тому +1

    Ups to 0.7amp se charge karta hai, kai aiya battery charge hogi, may be not

  • @manojevtechnology
    @manojevtechnology 2 роки тому +1

    Excellent, cell cost ky he ?

    • @VippoTech
      @VippoTech  2 роки тому

      Brand new cell 175/- per piece

    • @someshdey7431
      @someshdey7431 2 роки тому

      @@VippoTech kaha se kharida

  • @12villages
    @12villages 4 місяці тому +1

    Charging voltage of lead acid and lfp wont match.

    • @VippoTech
      @VippoTech  4 місяці тому

      Watch latest post your. Answer

    • @12villages
      @12villages 4 місяці тому

      @@VippoTech ok

  • @MobileRepairKing2847
    @MobileRepairKing2847 2 роки тому +1

    Price sir

  • @watwi9030
    @watwi9030 2 роки тому +1

    Is it 3c cell?

  • @sachinnejarproduction2775
    @sachinnejarproduction2775 2 роки тому +1

    But Lithium and others batteries charge and discharge current different

    • @VippoTech
      @VippoTech  2 роки тому

      It's lifepo4 battery and it's best replacement of lead acid battery

  • @mtechelectricvehicle1944
    @mtechelectricvehicle1944 2 роки тому +1

    👌👌👌👌

  • @Divyansh099
    @Divyansh099 2 роки тому +1

    Bike k liye bAttery banake bAtaye

  • @Pari973
    @Pari973 Місяць тому +1

    Cells wolt

  • @bubundhar
    @bubundhar Рік тому +1

    abe kuch load chalake dikhao

    • @VippoTech
      @VippoTech  Рік тому

      No

    • @bubundhar
      @bubundhar Рік тому

      @@VippoTech kyun? phir pata kaise chalega iska power

  • @patelvimal3591
    @patelvimal3591 Рік тому +1

    I tried the same but got one problem, my ups works normally on this battery if its already on and give backup after power cut, but if there is already power cut from grid then i can not start the ups iven if battery is fully charged.
    I need grid power to wakeup the ups
    I dont understand this problem help me

    • @devharish4368
      @devharish4368 9 місяців тому

      Because battery voltage is high

  • @patelvimal3591
    @patelvimal3591 Рік тому +1

    I tried the same but got one problem, my ups works normally on this battery if its already on and give backup after power cut, but if there is already power cut from grid then i can not start the ups iven if battery is fully charged.
    I need grid power to wakeup the ups
    I dont understand this problem help me

    • @VippoTech
      @VippoTech  Рік тому

      Don't know exactly
      Might be because of bms
      Mine battery will work properly

    • @patelvimal3591
      @patelvimal3591 Рік тому

      How much ah bms u r using

    • @patelvimal3591
      @patelvimal3591 Рік тому

      20 ah lipo4 bms, with i ball nirantar ups 621i

    • @patelvimal3591
      @patelvimal3591 Рік тому

      Amd wich bms u t using?