Suction Pump Installation | Piping

Поділитися
Вставка
  • Опубліковано 5 січ 2025

КОМЕНТАРІ • 49

  • @djoudjou1214
    @djoudjou1214 Рік тому +1

    I liked your upscale page posts

  • @piping-cadtutorial
    @piping-cadtutorial 4 роки тому +1

    The video is very helpful. Thank you about information you provide.

  • @ibsarkhan3770
    @ibsarkhan3770 5 років тому +2

    Shouldn't we use 3D or 5D of spool for ecc red from suction?

  • @nags8482
    @nags8482 6 років тому +2

    Would have added more info on the piping alignment or allowable deviation in between piping flange and pump nozzle, allowable shaft deflection during buttoning up the flanges.... Grouting details would have given more details like grouting method, clearing of blow holes or defecting grouting, final grouting....

  • @kanthan4729
    @kanthan4729 3 роки тому

    We should open the discharge isolation valve to lower the load on the prime mover? right?

  • @GemmyHeart
    @GemmyHeart Рік тому

    Main products: sealing gasket,gland packing,PTFE/graphite/asbestos products, ceramic fiber products, high temperature heat insulation and fireproof material.
    Free technical support (sealing, heat preservation, heat insulation, fire prevention problems)
    All products 1 piece can also be customized, 30 years of service experience, fast and safe shipping anywhere.

  • @SRINIVASAMBADI
    @SRINIVASAMBADI 6 років тому +1

    What about cavitation formation when we use flat side bottom eccentric reducer in positive suction head.

    • @sowmantung6457
      @sowmantung6457 6 років тому

      Ihave the same Question relate to Esentric reducer

  • @drewhartley6472
    @drewhartley6472 5 років тому +2

    Please have just one background music reduced level during the dialogue and kill the other beat music it’s distracting from what otherwise is a very informative film 😎

  • @calonpresiden3468
    @calonpresiden3468 5 років тому +1

    Good animation

  • @الهاشميالعبيدي-ز9ف
    @الهاشميالعبيدي-ز9ف 6 років тому

    هل هونا ك مضخاط ضغط مركزي لها القدر على استخرج المياه مسافة 80 متر بئر جوفي

  • @moirah1234
    @moirah1234 8 років тому +1

    Very informative. Thanks

  • @jiarahat5302
    @jiarahat5302 8 років тому +1

    very good information thanks

  • @balyanharahap899
    @balyanharahap899 6 років тому

    at 2:55 how long the minimum pipe after reducer?

  • @MTA141
    @MTA141 4 роки тому

    Hi Technical Piping, i have a question: Why we should fit eccentric reducer, maybe can make avoid air pocket formation? Thanks a lot!

    • @ansarbaig7183
      @ansarbaig7183 2 роки тому

      Old practice advised to use Ecc bottom flat but latest engineering practice says to use Ecc top flat no metter whether tank is A/G or U/G in order to avoid flowing bubbles in pump.

  • @saudkw92
    @saudkw92 4 роки тому

    Why isn't an isolation valve recommended?

  • @lighttv3770
    @lighttv3770 4 роки тому

    Informative

  • @RT-kh8rg
    @RT-kh8rg 5 років тому

    How do I located the suction line and discharge

  • @Komeh_
    @Komeh_ 3 роки тому

    arent we supposed to use a minimum of 5D rather than 3D?? API 686 Specified a minimum of 5D, please clarify. thanks

  • @aditya05umrao
    @aditya05umrao 6 років тому

    In which plateform this video made?

  • @mantvtor8305
    @mantvtor8305 5 років тому

    please explain and make video vibration standard of pump

  • @SkYadav-po6jk
    @SkYadav-po6jk 6 років тому +1

    Good

  • @HalftoneCHANNEL
    @HalftoneCHANNEL 8 років тому

    without grouting between foundation and base you can expect excessive vibration and noise

  • @khalilahmad882
    @khalilahmad882 4 роки тому +1

    Gr8

  • @shaginpaul5488
    @shaginpaul5488 2 роки тому

    Brother please mention standards accordingly...for reference..

  • @cmmc116
    @cmmc116 7 років тому

    Hi, new subscriber here. A question. The 6% slope is absorbed for the inlet gasket?

    • @phiksit
      @phiksit 7 років тому +1

      You would have to make a angular / mitered fit up at the eccentric reducer to get your slope.

  • @naglp7981
    @naglp7981 7 років тому +1

    please tell me how to select size of pipe

    • @silambarasanveerachamy3453
      @silambarasanveerachamy3453 7 років тому

      Nag Lp it's depends on the pump nozzle size...

    • @nags8482
      @nags8482 6 років тому

      Pipe size selection is based on pump nozzle size, pump nozzle size is based on process flow and head requirements. Types of pump selections are different and need to consider process and site conditions

  • @rajkumar-tk8dz
    @rajkumar-tk8dz 6 років тому +1

    sir ,please make ur vedio in Hindi also

  • @dixonaloysius1366
    @dixonaloysius1366 6 років тому +3

    the background music is interpreting the voice

  • @هردلانحلنج
    @هردلانحلنج 7 років тому

    yes

  • @niyonsengaolivier563
    @niyonsengaolivier563 5 років тому

    please share your video to us

  • @artin4580
    @artin4580 2 роки тому

    inclining upwards 6mm for 100 mm is wrong in.
    it is 6 mm for 1000 milimeter

  • @ansarbaig7183
    @ansarbaig7183 2 роки тому

    I am piping designer and I have worked in JGC Japan. Please improve yourself as described below.
    1.Discharge piping on the nozzle is not good practice. Load on pump nozzle cause disturbance of pump alignment.
    2. Reducer with pump nozzle is not good. There should be 5d straight run between Reducer and pump in order to provide turbulence free flow to pump.
    3. There is to be Ecc Reducer top flat even if flow is from A/G tank.

    • @AliAhmad-df2sf
      @AliAhmad-df2sf 2 роки тому

      Hi
      How can I contact with you !!!
      Plz reply
      I want to ask couple of questions.

    • @ansarbaig7183
      @ansarbaig7183 2 роки тому

      @@AliAhmad-df2sf Can you ask the question at this panel. Please introduce your self too. I Don't mind to render my services.

    • @samueljebaraj4742
      @samueljebaraj4742 2 роки тому

      Why don't go for bottom flat bro for eccentric reducer ?? is there any standard reason in it ??

    • @ansarbaig7183
      @ansarbaig7183 2 роки тому

      @@samueljebaraj4742 Ecc B/F is an old practice. If you see American "piping guide" old version, there's same. However, the latest practice in most reputable companies like Technip, Bechtel, Florabia, JGC, Aramco & Adco is to keep Top flat as latest practice. The reason is to avoid bubbles generation in the upper cavity of reducer. The RPM of pump is 3000 or sometimes more, even the little quantity of bubbles attack the pump impeller like bullet which reduces the life of pump. Moreover bubble causes noise and vibration too. Piping Designing is a vast field, however Designing around pump is most easy and simple. If you are keen fully interested, we can share our views on every type of piping Designing in future.

    • @ansarbaig7183
      @ansarbaig7183 2 роки тому

      @@AliAhmad-df2sf how do you like to contact me?

  • @sovereignjocker2556
    @sovereignjocker2556 3 роки тому +1

    Kindly try to avoid this background music. So annoying and not able to listen to your explanation.

  • @neerajpokhriyal7958
    @neerajpokhriyal7958 Рік тому

    copy

  • @mantvtor8305
    @mantvtor8305 5 років тому +1

    good animation