  • @lawrenceflynn8245
    @lawrenceflynn8245 8 місяців тому +1

    where is that purple wire going? I need to know

    • @IndRepair
      @IndRepair  7 місяців тому

      It will go to a connection to the battery don't have this mower still here to check sorry

    • @lawrenceflynn8245
      @lawrenceflynn8245 7 місяців тому

      @@IndRepair Thanks so much

  • @CSERepair
    @CSERepair 2 роки тому +2

    I hope you can respond , but I’m having the same issue! ECV740 kohler replaced stator and flywheel because magnets came loose.
    Did testing and from the middle insert on the rectifier to ground/battery I get 0 . Do I definitely have a bad rectifier? Because if I juice pack jumó the battery it turns on but slowly after about 5 mins dies off.

    • @IndRepair
      @IndRepair  2 роки тому +1

      Hello there! Yes this would cause the unit not to start again because the battery keeps going dead. Once you jump it again it starts and runs for a while yes?

    • @CSERepair
      @CSERepair 2 роки тому +1

      @@IndRepair yup considering it’s a brand new battery aswell, I can jump it as many times , it will just end up shutting off after the battery drains.
      Thank you!
      I appreciate your quick response, Looking forward to seeing new content

    • @IndRepair
      @IndRepair  2 роки тому

      Good job!! Thanks for watching!!

  • @SARDOG
    @SARDOG Рік тому

    My rectifier black connector is melting. Ordered a new one. 1999 Craftsman riding mower. Good times.

    • @IndRepair
      @IndRepair  Рік тому

      Sure is fun times! Thanks for watching!

  • @jasonmelancon8096
    @jasonmelancon8096 5 місяців тому +1

    Just went through this with a Kawasaki. Found out that I fried the voltage regulator with a jump starter.

    • @IndRepair
      @IndRepair  4 місяці тому

      Definitely see it a lot. Remove a jump pack or cables soon as a mower starts to prevent this from ever happening

    • @justafig
      @justafig 2 місяці тому

      Ya stripped them out. You should have hand tightened them going into the housing.

    • @justafig
      @justafig 2 місяці тому

      ​@@IndRepairread my post mechanic lol

    • @IndRepair
      @IndRepair  2 місяці тому

      Not stripped, both tightened up good