Control Panel Build Series Part 17: Wiring Power Distribution

Поділитися
Вставка
  • Опубліковано 23 лип 2024
  • Get the FULL video transcript here: www.rspsupply.com/education/a...
    Want to see similar products to those featured in this video: www.rspsupply.com/c-620-cable...
    Check out our full line of Industrial Hardware on our website: rspsupply.com
    Additional Links -
    Website:
    rspsupply.com/
    Engineering Page:
    rspsupply.com/engineering/
    Panel Fabrication Page:
    rspsupply.com/panel-fabrication/
    Procurement Services Page:
    rspsupply.com/procurement-ser...
    Manufacturers Page:
    rspsupply.com/manufacturers.aspx
    Panel Fabrication Page:
    rspsupply.com/panel-fabrication/
    Panel Hardware:
    rspsupply.com/c-34-panel-hard...
    Enclosures:
    rspsupply.com/c-1618-enclosur...
    Terminal Blocks & Connectors:
    rspsupply.com/c-1635-terminal...
    Cable Wire & Assemblies:
    rspsupply.com/c-620-cable-wir...
  • Навчання та стиль

КОМЕНТАРІ • 58

  • @silenzzio
    @silenzzio 6 років тому +2

    Now you are getting to the real deal 👍

  • @ucar_technology
    @ucar_technology 10 місяців тому +1

    Thanks for sharing. I love wiring control panels.

  • @rehannazgulkhan8020
    @rehannazgulkhan8020 4 роки тому +1

    Useful RSP supply
    Education
    Series

  • @American_Made
    @American_Made Рік тому +8

    Why not use ferrules on your wire ends?

    • @MRBenchwork
      @MRBenchwork 5 місяців тому +1

      I'm a Newb and that was my first question too. Seems like a no brainer.

  • @farajali9170
    @farajali9170 6 років тому +4

    at the moment I'm practicing at one of the automation companies and I think I'll get the job because of your videos.

    • @RSPSupply
      @RSPSupply  6 років тому +2

      Thanks. We're glad they are helping

  • @zivgruber8036
    @zivgruber8036 5 років тому +25

    There should really be terminal crimps on all the wires being screwed down

    • @muhammadmajar6011
      @muhammadmajar6011 4 роки тому +2

      I'd also noticed that , even with bigger wire gauge you need terminals and a crimp

  • @petrutarabuta5617
    @petrutarabuta5617 3 роки тому

    Thanks!

  • @ivangheorghe7794
    @ivangheorghe7794 2 роки тому +2

    Why I didn,t saw any ferules at the end of the wires?

  • @imraanmkuya8625
    @imraanmkuya8625 4 роки тому +4

    WHY YOU DONT USE BOOTLACE FERRULES IS THERE ANY PARTICULAR REASON

  • @kashifnazir4634
    @kashifnazir4634 2 роки тому

    Sir, what mm2 of wire is use for plc , contractor, relay and supply in panel (SWG)?

    • @1337Invis
      @1337Invis Рік тому +1

      That is determined by your fuses/circuit breakers. 20A 2,5mm2 14A 1,5mm2...

  • @MryoungbloodCity
    @MryoungbloodCity 5 років тому +4

    I really wish you could have done this video slower with more of a walk through.By that I mean which wire goes where and comparing it to the drawings so that we could better understand why your putting each particular wire here and there. love you videos though!

    • @RSPSupply
      @RSPSupply  5 років тому +2

      See our Control Panel Build Series. It shows how to plan, layout, install hardware, all wiring and testing.

    • @MryoungbloodCity
      @MryoungbloodCity 5 років тому +2

      @@RSPSupply thanks I'll check that out!

  • @magicplaykz
    @magicplaykz 4 роки тому +1

    Why are tips not used?
    The cable cross section is large.

    • @RobShreds
      @RobShreds 3 роки тому +1

      I’m glad I wasn’t the only one thinking this ✨Ferrules✨

  • @brynsparks
    @brynsparks 3 роки тому +1

    Why is the Phoenix contact plugtrab upside down?

    • @nickr753
      @nickr753 27 днів тому

      They are wiring the AC distribution consistently with line side on top and load side on the bottom, and I'll bet they incorrectly assumed that the PLUGTRAB is "directional" -- a look at the schematic diagram says that it's not; it's actually a parallel device, not a serial one.

  • @urhuck1eberry
    @urhuck1eberry 6 років тому +5

    4:20 ferrules

    • @biglouATLien
      @biglouATLien 5 років тому +1

      they are sooooo cheap lol

    • @trabadix
      @trabadix 4 роки тому

      @@biglouATLien lol x2

  • @GroupGangPresent
    @GroupGangPresent 2 роки тому

    What you are wiring at 3:09
    What is the use of it?? What is the name?
    Please someone help

    • @pieguy2
      @pieguy2 2 роки тому +1

      It is a relay. The manufacturer is Phoenix Contact. 2900304 is the part number of you want to look at the data sheet.

  • @jamiemcclung3601
    @jamiemcclung3601 4 роки тому +2

    No crimps?

  • @allenvincent4141
    @allenvincent4141 5 років тому +17

    A power screwdriver is not the tool to use when wiring a panel. You have more of a chance of over-tightening and damaging components.

    • @singerkgreen
      @singerkgreen 2 роки тому +3

      My Milwaukees allow for setting exact torque settings.

  • @rollformerfabricator2433
    @rollformerfabricator2433 4 роки тому

    Good control pane engineer

  • @salarbadeel4471
    @salarbadeel4471 2 роки тому

    👍👍

  • @soksong4726
    @soksong4726 3 роки тому

    한국의 장비배선도 이렇게 바꿔야 합니다
    지금처럼 단자를 사용하면 실수가 너무 많이 발생합니다

  • @anirbansasmal4942
    @anirbansasmal4942 2 роки тому

    Modicon plc bro

  • @IceyJunior
    @IceyJunior 4 роки тому +3

    Can you teach the wiring more technically? In details.

    • @JoshOntko
      @JoshOntko 3 роки тому

      Yes, please, I concur. I realize there are details unique to the various voltages, and plans, but it would be great to mention what gage wire, THHN vs MTW etc, how to test out the circuits, how much distance you use on your wire way and the components, the names of the tools etc.

  • @Randriekus_TestPilot
    @Randriekus_TestPilot 2 роки тому

    why is he not using cable shoes ?

  • @Mamooshiiii
    @Mamooshiiii 2 роки тому

    cable shoes may help

  • @PelagoA
    @PelagoA 3 роки тому +3

    You made another nice video (ua-cam.com/video/qUMyFbhy92c/v-deo.html ) where you explain why it is important to use wire ferrule terminals, and in this video they are not being used! Not even being mentioned I think?!

  • @nesargent
    @nesargent Рік тому +2

    You should really be using ferrules. And ditch the screw gun, even if the torque is set low.
    Good work other than that.

  • @alvarodiaz945
    @alvarodiaz945 10 місяців тому

    ... And the ferrules?????

  • @tobystahl6144
    @tobystahl6144 4 роки тому +5

    The conversation really has nothing to do with the specific video Talk about the steps and penal functions that the election is working on an not safety hazards

  • @andressilva2402
    @andressilva2402 2 роки тому +1

    All I learned was fire hazard and be careful 🤦‍♂️I need a walkthrough with the schematics.

  • @Buciasda33
    @Buciasda33 4 роки тому +6

    120 - 240V and he talks about safety... Weakness disgusts me.
    3:36... always use insulated terminals / pins for stranded wires. Never push stranded wires like that.

    • @trabadix
      @trabadix 4 роки тому +1

      I see that, and that method are very bad, stranded wire without terminal.

    • @leandrogerardo9521
      @leandrogerardo9521 4 роки тому +2

      Bootlace ferrule.

  • @mohdazril8964
    @mohdazril8964 3 роки тому

    better use ferrule

  • @trabadix
    @trabadix 4 роки тому +5

    Las terminales en cables de múltiples hilos es normativo, es una regla, y poner cables de arriba hacia abajo o similar es mala idea, lo ideal es seguir el diagrama comenzando por la distribución de poder, despues las etapas de protección, despues el control de entrada/salida, etc,... Bueno, por lo menos asi me enseñaron cuando diseñaba para ABB... Lo diría en inglés pero les hago un favor haciéndoles intentar aprender un idioma nuevo a quien solo habla/escribe en ingles o cualquier otro idioma lol

  • @azeemahammed8646
    @azeemahammed8646 4 роки тому +1

    Use solid ware from safety point of view rather stranded

    • @johnschroeder3072
      @johnschroeder3072 3 роки тому +1

      Can you explain how that would be safer.

    • @azeemahammed8646
      @azeemahammed8646 3 роки тому

      @@johnschroeder3072 it could avoid loose contact at the terminal side,so that the fire incident can be avoidable !

    • @johnschroeder3072
      @johnschroeder3072 3 роки тому +1

      @@azeemahammed8646 The better option would be to use flexible stranded wiring and to use boot lace ferules on the end to keep the wires together in the terminal. This would end up with better surface contact, less sensitivity to vibration and less likely that the conductor will break.

  • @djnugz2511
    @djnugz2511 Рік тому

    There's so many bad choices in this video lol. No ferrules, service loops, etc. Never seen someone use a power tools on components like that.... I would never

    • @USA__2023
      @USA__2023 Рік тому

      My first time hearing about ferrules. I probably would have used them if I knew about them. It's crazy but I usually go back to a new control and re torque all of the connections. Service loops, you bet....