22. ABB ACS880 Master Follower Configuration

Поділитися
Вставка
  • Опубліковано 30 лис 2024

КОМЕНТАРІ • 30

  • @UaeAjaiShukla
    @UaeAjaiShukla 2 роки тому

    Great work ....I was looking this video from last 1 year . May God bless you .

  • @bhaskarpatnaik434
    @bhaskarpatnaik434 Рік тому

    Nice sir,its very useful &important video ,sir I request for using of user defined macro using run different rating motors in different modes

  • @adaptine
    @adaptine 9 місяців тому

    Thanks for the video. How would one best control the follower in "emergency" in case there is an failure with the master?

  • @RicharGeovannyChuquiChicaiza
    @RicharGeovannyChuquiChicaiza 5 місяців тому

    Excellent explication..

  • @peterufrancess9344
    @peterufrancess9344 3 місяці тому

    十分感谢

  • @АдхамжонМамаджонов

    Thanks! can you will show programming drive ACS880 in automation builder, FSO safety settings and so on. That would be cool

  • @nitinmaind8967
    @nitinmaind8967 2 роки тому

    Sir aap ke videos bahut helpful hai .
    I request you plz make video on master slave and load sharing application

    • @averageengineer4266
      @averageengineer4266  2 роки тому

      Load sharing is possible when the follower is configured as a torque follower. I have explained this in the video

  • @denishpatel8830
    @denishpatel8830 2 роки тому

    EXCELLENT EXPLANATION.....Can you simulate stall protection of ACS 880 drive??

    • @averageengineer4266
      @averageengineer4266  2 роки тому

      Motor stall function is available under fault function. You can define max current limit expected during motor stall ,and define the stall speed and stall time.

    • @denishpatel8830
      @denishpatel8830 2 роки тому

      @@averageengineer4266 thank you for your reply...

  • @thakernayl1692
    @thakernayl1692 2 роки тому

    Hello, great work, thanks. I have question for you, I worked with m/f but I got vibration! could you tell me which of the modes gives less vibration (Torque or Speed control)

  • @sanathkumar2562
    @sanathkumar2562 2 роки тому

    Thanks for sharing your knowledge

  • @sushildhariwal8694
    @sushildhariwal8694 2 роки тому

    Good Explanation...Thanks

  • @huntersama1686
    @huntersama1686 Рік тому +1

    Hello, thank for your videos they are very helpful! However, i have a small issue with the M/F config, which is that the Follower doesn't recieve the Master's used speed reference even though i made the same configuration (PLC not included). Some help would be very much appreciated !

    • @averageengineer4266
      @averageengineer4266  Рік тому

      Hi, does the follower get the start command from master?

    • @huntersama1686
      @huntersama1686 Рік тому

      @@averageengineer4266 Hi, no the follower doesn't get any information.

    • @averageengineer4266
      @averageengineer4266  Рік тому

      Not sure what went wrong, you could check the d2d link

    • @huntersama1686
      @huntersama1686 Рік тому

      I've tried it with new drives (ACS880 ZCU 12) it didn't. It worked with two orhers (ACS 880 ZCU 12L)

  • @sajjadgolchin768
    @sajjadgolchin768 2 роки тому

    thanks.

  • @UaeAjaiShukla
    @UaeAjaiShukla 2 роки тому

    Are you providing any off line training for the ABB DCS / PLC / Drives .??

    • @averageengineer4266
      @averageengineer4266  2 роки тому

      Never done training bro, i just make video when i get time.., thx

  • @paulrajesh42
    @paulrajesh42 Рік тому

    In our project we are using two acs880 vfds in master-follower configuration. We are facing a problem that sometimes(not always) even master is stopped the slave still keep running. We switced master to slave and slave to master as well but still some time this happens to the slave again. Yet we do not have any idea what the problem is. Could you please advice what is the problem?

    • @averageengineer4266
      @averageengineer4266  Рік тому

      Can u share drive parameter backup

    • @deviprasadpattanaik4634
      @deviprasadpattanaik4634 Рік тому

      What have you observed?

    • @deviprasadpattanaik4634
      @deviprasadpattanaik4634 Рік тому

      In acs800 master slave configuration,Sometime slave run in negative direction even if master is running in forward direction.Here slave is torque follower of master.During this time we have observed slave goes to negative torque where as master torque is positive.

  • @revappabellakere9522
    @revappabellakere9522 6 місяців тому

    Sir how to communicate 2 drive in drive composer

  • @UaeAjaiShukla
    @UaeAjaiShukla 2 роки тому

    Is it possible to configure Master follower , without using D2D link ???

    • @averageengineer4266
      @averageengineer4266  2 роки тому

      D2D link is available on all acs800 drives. Other option is to use additional fdco card and use fiber optic cable for communication