There are a lot of entertainment channels but it's great to see people like you who are so creative and knowledgable and so helpful and teach technical stuff related to PIPING. You will always have our support to grow your UA-cam site
I am so happy that even at my age of69,I learn so many new things fm u.I salute you. This topic taught me something which I never imagined is possible. Look forward to more fm u.
Dear Sir, Thanks for sharing new information. My query is shall do you have experience of using this type of arrangement in Oil and gas(1. we use stud bolts ,2. Any issue in high pressure lines).
Sir, We have encountered same issue in current project. Project team decided to make hole in large dia meter flange respect to small dia flange. Kindly suggest this method is correct.
@@rajkumar-fz8jn in that case, gasket for large dia and small dia may not seat properly. It will be better to use a double studded adapter as I have explained.
@@gourisankarsamanta7670 sir, Thanks so much. Additional query often valve flange PCD and pipe flange pcd is not similar. How to ensure during procurement both flanges pcd are the same.
There are a lot of entertainment channels but it's great to see people like you who are so creative and knowledgable and so helpful and teach technical stuff related to PIPING. You will always have our support to grow your UA-cam site
I am so happy that even at my age of69,I learn so many new things fm u.I salute you.
This topic taught me something which I never imagined is possible.
Look forward to more fm u.
Nenu mi venu gopala rao ne . Mi piping video ani chustanu chala clear la untaci
I think we can also use adapters and crossovers for this purpose. Could you advise.
Legend of piping engineering 🙏🙏🙏🙏
nice explanation thanks.
I’ve never known about it. Very interesting.
Thank you Sir..!!
Very informative video.
We humbly request you to post atleast one short video per day on your UA-cam site as much as possible.
Very good video
Thanks
Dear Sir, Thanks for sharing new information. My query is shall do you have experience of using this type of arrangement in Oil and gas(1. we use stud bolts ,2. Any issue in high pressure lines).
It can be used in any piping irrespective of service because it is technically possible.
Sir, We have encountered same issue in current project.
Project team decided to make hole in large dia meter flange respect to small dia flange.
Kindly suggest this method is correct.
What would happen if make additional holes on a large dia flange
@@rajkumar-fz8jn in that case, gasket for large dia and small dia may not seat properly. It will be better to use a double studded adapter as I have explained.
@@gourisankarsamanta7670 sir, Thanks so much. Additional query often valve flange PCD and pipe flange pcd is not similar. How to ensure during procurement both flanges pcd are the same.
@@rajkumar-fz8jn during procurement we should purchase proper flange as per valve.
Today we are very happy to learn a new information about how to connect two different types of flange class rating in the PIPING