Quantity Calculation of Shuttering Material for Slab and Beam | Step-by-Step Guide 🔥

Поділитися
Вставка
  • Опубліковано 8 вер 2024
  • Quantity Calculation of Shuttering Material for Slab and Beam | Step-by-Step Guide 🔥
    🟢 𝐅𝐨𝐫 𝐨𝐟𝐟𝐥𝐢𝐧𝐞 𝐓𝐫𝐚𝐢𝐧𝐢𝐧𝐠 / 𝐨𝐧𝐥𝐢𝐧𝐞 𝐥𝐢𝐯𝐞 𝐬𝐞𝐬𝐬𝐢𝐨𝐧 𝐨𝐫 𝐚𝐧𝐲 𝐚𝐬𝐬𝐢𝐬𝐭𝐚𝐧𝐜𝐞 𝐲𝐨𝐮 𝐦𝐚𝐲 𝒄𝒂𝒍𝒍 𝒐𝒓 𝑾𝒉𝒂𝒕𝒔𝑨𝒑𝒑 𝒂𝒕 +𝟵𝟭𝟵𝟳𝟭𝟭𝟭𝟱𝟱𝟱𝟴𝟱
    🔴𝐅𝐨𝐫 𝗥𝗲𝗰𝗼𝗿𝗱𝗲𝗱 𝐬𝐞𝐬𝐬𝐢𝐨𝐧
    𝐃𝐨𝐰𝐧𝐥𝐨𝐚𝐝 𝐑𝐞𝐢𝐧𝐟𝐨𝐫𝐜𝐞 : 𝐂𝐢𝐯𝐢𝐥 𝐄𝐧𝐠𝐢𝐧𝐞𝐞𝐫𝐬 𝐥𝐞𝐚𝐫𝐧𝐢𝐧𝐠 𝐚𝐩𝐩.
    👉𝐀𝐧𝐝𝐫𝐨𝐢𝐝 𝐚𝐩𝐩 𝐥𝐢𝐧𝐤 : bit.ly/425ebrk
    👉𝐖𝐞𝐛/𝐏𝐂/𝐋𝐚𝐩𝐭𝐨𝐩 𝐋𝐢𝐧𝐤: web.reinforceqs...
    👉𝐌𝐲 𝐢𝐧𝐬𝐭𝐢𝐭𝐮𝐭𝐞 𝐚𝐩𝐩 𝐟𝐨𝐫 𝐈𝐎𝐒 𝐥𝐢𝐧𝐤: apple.co/3HFwBqo
    Org code : avywj
    📧 Email : reinforceqst@gmail.com
    🌐 Website : www.reinforceqst.com
    -----------------------------------------------------------------------------------------------------------------------
    As a civil engineer, accurate quantity calculation of shuttering material for slab and beam construction is essential to ensure the success of your project. In this video, we will provide you with a step-by-step guide on how to calculate the quantity of shuttering material required for your construction project.
    We understand that as a civil engineer, you require precise and detailed information. Therefore, we will provide you with easy-to-follow examples and illustrations that will simplify the calculation process. We will also cover common mistakes to avoid when calculating shuttering material quantity, including overestimating or underestimating the surface area and not considering the spacing of the supports.
    By the end of this video, you will have a thorough understanding of how to calculate the quantity of shuttering material required for slab and beam construction. This knowledge will enable you to plan and execute your construction project effectively, saving costs and avoiding unnecessary delays.
    So, if you're a civil engineer looking to enhance your knowledge and skills, this video is a must-watch. Don't forget to hit the like👍 and subscribe💖 button for more informative videos like this one!
    ============================================================
    Follow Us on; Facebook : / reinforceqstpl
    Instagram : / reinforce_qst
    Twitter : / reinforce_qstpl
    #reinforce #civilengineering #construction #calculation #quantity #shuttering #material #slab #beam #stepbystep #quantitysurveyor #training

КОМЕНТАРІ • 27

  • @ReinforceInstitute
    @ReinforceInstitute  Рік тому

    🟢 𝐅𝐨𝐫 𝐨𝐟𝐟𝐥𝐢𝐧𝐞 𝐓𝐫𝐚𝐢𝐧𝐢𝐧𝐠/ 𝐨𝐧𝐥𝐢𝐧𝐞 𝐥𝐢𝐯𝐞 𝐬𝐞𝐬𝐬𝐢𝐨𝐧 𝐨𝐫 𝐚𝐧𝐲 𝐚𝐬𝐬𝐢𝐬𝐭𝐚𝐧𝐜𝐞 𝐲𝐨𝐮 𝐦𝐚𝐲 𝒄𝒂𝒍𝒍 𝒐𝒓 𝑾𝒉𝒂𝒕𝒔𝑨𝒑𝒑 𝒂𝒕 +𝟵𝟭𝟵𝟳𝟭𝟭𝟭𝟱𝟱𝟱𝟴𝟱
    🔴𝐅𝐨𝐫 𝗥𝗲𝗰𝗼𝗿𝗱𝗲𝗱 𝐬𝐞𝐬𝐬𝐢𝐨𝐧
    𝐃𝐨𝐰𝐧𝐥𝐨𝐚𝐝 𝐑𝐞𝐢𝐧𝐟𝐨𝐫𝐜𝐞: 𝐂𝐢𝐯𝐢𝐥 𝐄𝐧𝐠𝐢𝐧𝐞𝐞𝐫𝐬 𝐥𝐞𝐚𝐫𝐧𝐢𝐧𝐠 𝐚𝐩𝐩.
    👉𝐀𝐧𝐝𝐫𝐨𝐢𝐝 𝐚𝐩𝐩 𝐥𝐢𝐧𝐤: bit.ly/425ebrk
    👉𝐖𝐞𝐛/𝐏𝐂/𝐋𝐚𝐩𝐭𝐨𝐩 𝐋𝐢𝐧𝐤: web.reinforceqst.com/
    👉𝐌𝐲 𝐢𝐧𝐬𝐭𝐢𝐭𝐮𝐭𝐞 𝐚𝐩𝐩 𝐟𝐨𝐫 𝐈𝐎𝐒 𝐥𝐢𝐧𝐤: apple.co/3HFwBqo
    Org code : avywj
    📧 Email : reinforceqst@gmail.com
    🌐 Website : www.reinforceqst.com

  • @shayemahmad4213
    @shayemahmad4213 Рік тому +2

    Best channel for civil engineering students. Thanks u sir for explaining in such details

  • @swarupchandanandanand808
    @swarupchandanandanand808 Рік тому +4

    Annealed wire also called in technical word
    Outstanding explain sir ❤❤❤❤❤❤

  • @dhirajshinde3977
    @dhirajshinde3977 Рік тому +2

    Thank you sir

  • @vishnushau
    @vishnushau Рік тому

    Bahut badiya super 🙏

  • @rupeshkumarpajiyar8252
    @rupeshkumarpajiyar8252 Рік тому

    Sirji please make videos on different pile tests like O-Cell test,PIT test, PDA test etc. It will be very informative

  • @saquibahmed911
    @saquibahmed911 11 місяців тому

    Thanks

  • @nasar737
    @nasar737 Рік тому +1

    Sir beam bottom me extra 15% add q kre wo to slab flat ara me hi include h

  • @kaushikc235
    @kaushikc235 4 місяці тому

    Is PCC shuttering quantity to be consider in billing as per IS 1200?

  • @RKAliKhan025
    @RKAliKhan025 Рік тому

    Good

  • @battlewithdestiny5327
    @battlewithdestiny5327 Рік тому

    Sir please make video on MIVAN shuttering

  • @johnsmith-tm1dk
    @johnsmith-tm1dk Рік тому

    Apparently, as per your analogy, you seem to have considered the consumption quantity of nails as 400 grams per ply board? Please review 🙏

  • @mdshahbaz9006
    @mdshahbaz9006 Рік тому

    Technical name for Binding Wire is "Tie Wire or Annealed Wire".

  • @bbpillai5800
    @bbpillai5800 10 місяців тому +1

    Sir, aap slab ka ply calculate nahi kiya

  • @babukh1022
    @babukh1022 8 місяців тому

    Sir what about column size ,we have to deduct na?

  • @rahulhatkar9554
    @rahulhatkar9554 Рік тому

    Sir Quantity of batten value should be 20.88 Cub m

  • @pandeyanurag5145
    @pandeyanurag5145 Рік тому

    Ji sir ji

  • @navjotsemwalallinone2569
    @navjotsemwalallinone2569 Рік тому

    Sir ager beam ka size different ho tu tbi bhi 30% hi liya jayega kya sir

  • @gangeshkumar2126
    @gangeshkumar2126 Рік тому +1

    Sir Slab props ke liye .9x.9 ku kiye h
    Props ka c/c distance .9m hota h na
    But ye to Area ho gya .9x.9
    Please explain me sir.

    • @mdshahbaz9006
      @mdshahbaz9006 Рік тому

      Bhai agar only slab ki baat karenge to hum slab area consider karte hai jiske wajah se 1 Vertical Ms Props kitna area cover karega wo nikalte hai. That's why props spacing is multiplied.

  • @kaunho2437
    @kaunho2437 10 місяців тому

    Where is slab flat area for fly board? 226m2

  • @navjotsemwalallinone2569
    @navjotsemwalallinone2569 Рік тому

    Sir slab concrete me kitne % beam liya jata h sir

  • @ajaychaudhari6934
    @ajaychaudhari6934 Рік тому

    Slab ke liye Ms props spacing 0.9×0.75 m hoga kyu ki Ms plate ki size 0.75×0.6 hai ....aapne 0.9 × 0.9 bataya hai

    • @zahidahmad6882
      @zahidahmad6882 Рік тому

      Spacing btw the props should be 0.9m under slab, so the area that prop will cover will be 0.9*0.9

  • @beebhu052704003
    @beebhu052704003 6 місяців тому

    Specifications of MS Channel

  • @amitprabhat531
    @amitprabhat531 Рік тому +2

    Thank you sir

  • @ANVIRAJ123
    @ANVIRAJ123 Рік тому

    Good