It will open with a failed igniter, but only briefly. Once the circuit board has not received a signal back from the flame sensor for more than a couple of seconds after opening the gas valve, it will close the gas valve and attempt to light again. Usually they will try 3 times before locking themselves out.
what about the burn leakage along the front of the burner tubes. DID YOU CLEAN OUT THE "basement" of the furnace closet and a new air filter? Just things not explained four us non-HVAC guys...
We love watching your videos in class. Leads to great conversations and expands our knowledge base.
Great to hear!
Good job Curtis, a nice easy one for a change 👍 Au
Only takes a couple extra minutes to pull and clean the flame sensor while you're at it.
Love watching this guy as I am going through my year long hvac school program helps out a lot!
Thanks for the video. Stay safe out there.
You bet
Great easy fix. Well deserved!
Please get a head lamp. Time saver. Every where you look there will be light
Let's buy one for him
Nice work Curtis.
Good job curtis
Good video 😀
Thanks 😁
Those wires are a service call at 2am on a Saturday night. On that burner section.
Great repair curtis 👍✌️
Thanks 👍
Well done Curtis 👏
Thanks
Great job Curtis.
Thanks
Nice video as always I like your videos
My understanding is the gas valve will not open until the board gets verification that the hot surface igniter is operational.😮
It will open with a failed igniter, but only briefly. Once the circuit board has not received a signal back from the flame sensor for more than a couple of seconds after opening the gas valve, it will close the gas valve and attempt to light again. Usually they will try 3 times before locking themselves out.
@ I don’t agree.
@@5metalacid1correct
Don't sneeze! 😎👍
Good video
Thanks
Nice job
Thanks!
NO Heat Call in November in Sunny Georgia ? We had 72 in St. Louis today (11/18/24) and it was Not a Record. 🤔😬👍
I’m in Augusta & it’s been in the 50’s every night this week
👍👍👍
You find it easier to work on furnaces or air conditioning units?
The same
a gas pack is a/c with a boiler apparatus all I have to do is check for cooling and heating disect from there
Did you have that part on your truck or did you go to the supply house to get it.
Had to go get it
Did you replace the filter?
Yes
Gas flex connector runs thru furnace cabinet around inducer, is this common practice down south?
No
Those wires around the burners was making me very nervous
hoping it’s a gas valve according Ted cook
with heat strips duct heater
what about the burn leakage along the front of the burner tubes. DID YOU CLEAN OUT THE "basement" of the furnace closet and a new air filter? Just things not explained four us non-HVAC guys...
Yes, and yes.
Hi bro
Hello
@ what up
@@jamierushingjust working
don’t touch it