How DG deep sea controller working | How to do wiring from deep sea controller to DG

Поділитися
Вставка
  • Опубліковано 22 сер 2024
  • What is deep sea controller and how it is working and why it is used in diesel generator and how to do wiring terminals connection from DG to DSE controller also explained in this video. So please watch it completely to get full idea.
    For more about electrical engineering please subscribe to our channel Electrical Mastar
    How DG is working click here :
    • DIESEL GENERATOR WORKING
    How DG starter solenoid is working click here :
    • HOW Diesel Generator S...
    How to do DG periodic maintenance click here :
    • How to do diesel gener...
    Electrical Switch Gear basics
    • Electrical Switch Gear...
    How Cathodic protection system working |Types |Application
    • How Cathodic protectio...
    How soft starter works | Wiring diagram of soft starter | Uses & Advantages of soft starter
    • How soft starter works...
    How Diesel Generator LOP sensors working | How to connect sensor to pressure gauge & DSE controller
    • How Diesel Generator L...
    How to Download & Install DSE controller software for Diesel Generator
    • How to Download & Inst...
    #DSEcontroller #DGcontroller #Deepseacontroller #DGtoDSEcontrollerwiring
    #DeepseacontrollerWiringDiagram

КОМЕНТАРІ • 148

  • @zenebehagos3537
    @zenebehagos3537 9 місяців тому

    you are a real electrical engineer sir Go a head, we will follow u intendedly

  • @emalrahmatzada1452
    @emalrahmatzada1452 2 роки тому

    Very clearly explained sir, really a great job, and thank you very much

  • @gopalk1977
    @gopalk1977 3 роки тому +1

    very good training i am waiting for more video

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thank you Mr. Gopal and keep support us 🙏🙏🙏🙏

  • @sandebrian5659
    @sandebrian5659 Рік тому +1

    Great

  • @shaneefh926
    @shaneefh926 2 роки тому +1

    Great class sir thanks a lot, u can also add a practical video also so it will be more informative

  • @user-er6mf2mh7p
    @user-er6mf2mh7p Рік тому

    Really helpful sir and easy to understand.
    Thank you...

  • @AdemMohammed-de8db
    @AdemMohammed-de8db 2 місяці тому

    Thanks sir Good Explanation

  • @nilankafernando5493
    @nilankafernando5493 3 роки тому +1

    thanks my friend

  • @prasadk7884
    @prasadk7884 4 роки тому +1

    This video most help for me ....thanking you sir.....and one more request please provide sedmac GC1211 controller software for me, we r facing lot of problems due to with out software...

    • @electricalmastar
      @electricalmastar  4 роки тому +1

      Thanks for your comments Mr. Prasad, let me check that software and let you know
      Thanks

  • @mohameddeik9556
    @mohameddeik9556 3 роки тому +1

    Keep it going this usefull video ..appload the next concepts for the deapsea electronics and configration software.

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments and deep-sea configuration video has posted in our channel please check this link
      ua-cam.com/video/4fFWw-ArKdA/v-deo.html
      Keep support our channel
      Thank you

  • @richieuntaran8530
    @richieuntaran8530 2 роки тому

    Nice video sir, sir the pin no. 30, 31 is n.c this use for contactor of main power and then the 32,33 is n.o for contactor of generator. Thanks sir

  • @dulcemachel1335
    @dulcemachel1335 4 роки тому +1

    And with you don't mind you could make a video talking about EMCEP and DSE ...

  • @mbwanaali6278
    @mbwanaali6278 3 роки тому +1

    Nice engineer

  • @senthilrasu3892
    @senthilrasu3892 2 роки тому

    Sir very nice to explain. We help oil pressure sensor fault comming .
    How can we by pass please. Thank u

  • @zenebehagos3537
    @zenebehagos3537 4 місяці тому

    superb video

  • @qatarcreationdohaqatar5708
    @qatarcreationdohaqatar5708 3 роки тому +1

    Hi, how are you? I have a dse 6110 mpu 4.1 which only looks green on the display and I can't see the parameters and I would like to be able to adjust that

  • @bishwajeetpatra1588
    @bishwajeetpatra1588 Рік тому

    Thanks a lot Sir. It was an extremely informative session. It cleared several of my doubts. I have a doubt regarding Deep Sea controllers. Can it be used for governing the speed of the Engine and adjusting the voltage of the AVR ? Please advice.

  • @tstechnicalsawant8505
    @tstechnicalsawant8505 4 роки тому +1

    Thanks sir for explanation i really like, but can you please explain how to connect rs232 and external start and stop

    • @electricalmastar
      @electricalmastar  4 роки тому

      Thank you for your comments , i will make separate video for RS232 connection and external remote start operation very soon.
      Kindly support our channel
      Thank you
      Electrical Mastar

  • @manirajumasavarapu1128
    @manirajumasavarapu1128 2 роки тому

    Super explained sir.

  • @muruganbhai699
    @muruganbhai699 2 роки тому

    i clearely understanad

  • @surafelasefa272
    @surafelasefa272 14 днів тому

    Cool

  • @chrisivardsouza1623
    @chrisivardsouza1623 3 роки тому +1

    Sir can you make a video DSE and ECM wiring

  • @1stoppowertech756
    @1stoppowertech756 Рік тому

    Sir
    I Wish to convert cat 250kva control to deepsea. Which model i should choose. Need synchronization also. Pump with atuator. Plz help.

  • @yerooftolee5565
    @yerooftolee5565 Рік тому

    May you explain me from where we can take and wire for 30 & 31 as well 32 & 33 using contactor and glass relay

  • @faiyadali8522
    @faiyadali8522 3 роки тому

    Good morning, very nice explained,I want to also,, explained in Hindi language,, hope you are cooperate with us.

  • @dsadzaglishvili
    @dsadzaglishvili 2 роки тому

    Please tell me how U connect fuel shut off solenoid?
    Can i make parallel connection with primer fuel pump line?
    EST solenoid not going on

  • @tamim.talukder
    @tamim.talukder Місяць тому

    please tell me how i am engine start and stop another push button switch.

  • @mb9932
    @mb9932 2 роки тому

    does the 6110 have a set of dry contacts that can carry 2amps at 240 volts

  • @SubodhKumar-qj4lq
    @SubodhKumar-qj4lq 2 роки тому

    Hello sir, excellent explained by you. Sir in 250 kva DG DSE pin number 10,11 and 12 used for health indication. 10 for green light, 11 for yellow and 12 is red. Problem is when switching on exciter supply that time green light must glow but it is not working. At pin 10 need O/P 24V but it is missing. What are may be possible cause ? Pin 10 to indication lamp wiring is fine. DG is working only health warning light not working. DSE is 7320 mkii

  • @user-qp5md3bh2v
    @user-qp5md3bh2v 8 місяців тому

    Hello. how to turn on the ignition without starting the engine ? DSE 7320

  • @moctarndiaye995
    @moctarndiaye995 3 роки тому +1

    thanks for your sharing. Please is it possible to have a PPT of contrôlers DSE73XX with DSE890 MKII.

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments and sorry I don't have the ppt for that now.
      Thank you

  • @milindgacche8925
    @milindgacche8925 3 роки тому +1

    Dear Sir,
    Please give information about
    Down load the program in controller

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments dear and dse downloading video as already i posted in our channel you can check here
      ua-cam.com/video/KGfpaEBvxic/v-deo.html
      Keep support our channel
      Thank you 🙏

  • @AnasAl-Dhafiri
    @AnasAl-Dhafiri 3 роки тому

    Many thanks

  • @fishamenbere2084
    @fishamenbere2084 3 роки тому

    Thank you so mach

  • @jjr897
    @jjr897 2 роки тому

    Do you have to use the SCR magnetic pick it up for the controller to work. Or can It pick up frequency from generator alternator?

  • @shanmalik7095
    @shanmalik7095 Рік тому

    Bhai humare pas generator hai alternatior moro back side se jal gai Hai Jahan 2 wire lagi hoti hai D+ AND B+ Or mein Saudi Arabia Rehta Hun or bohat jagah se motor doondh raha hun kahin nai mili or kia alternatior motor ko 3 wire lagana zaruri hai ground Jahan D+B+ wire lagi ho pls muje batana humara jenrotr just crank start leta Hai 3 bar bad mein wo started to failed aata hai kia ye problem alternatior motor jalne ki Waja se hai ya koi or masla Hao muje batana pls meij kia kron I'll wait ur answers Humara generator 7320 kaii hai pls

  • @richieokello2162
    @richieokello2162 2 роки тому

    Hello thanks can u plz guide on electrical interlock and how 30 to 33 are connected on the magnetic contactors

  • @michaelherrera5562
    @michaelherrera5562 2 роки тому

    How can we by pass the low level coolant alarm or disable ? that causes the generator to shut down without using software.

  • @avisheshsingh2644
    @avisheshsingh2644 2 роки тому

    good day sir i need to knw how can i find
    the wire to start a generator

  • @afifamrulloh6975
    @afifamrulloh6975 Рік тому

    Hi sir, the generator could be auto start or on if the power system off

  • @y2ye
    @y2ye 2 роки тому

    sir would you like to explain to us, where is the pin used for Remote start function please?

  • @mwanawahakaemmanuel7232
    @mwanawahakaemmanuel7232 2 роки тому

    Thanks alot

  • @mohammedabdulhadi7312
    @mohammedabdulhadi7312 3 роки тому +1

    Can I use the analog input signals for the ddc panel

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments and yes you can give analog input signal to dse panel
      Thank you keep support us

  • @florenciochirruque3324
    @florenciochirruque3324 3 роки тому +1

    Electrical master please help me with the wiring diagrams of HGM6100N-RM
    REMOTE CONTROL MODULE

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments let me try for your request
      Thank you

  • @MrNandu32
    @MrNandu32 2 роки тому

    Nice..

  • @sabastinsabz8813
    @sabastinsabz8813 3 роки тому

    Hello can you explain why emergency symbol appear on screen and shutdown the genset when the switch does not engaged

  • @goswamishab5263
    @goswamishab5263 Рік тому

    Pls conduct a class on calibration of this module

  • @AbdulkabirMohammed-ou9fm
    @AbdulkabirMohammed-ou9fm Рік тому

    Good evening, pls I would like to get that control model shown

  • @jrabot2035
    @jrabot2035 Рік тому

    Hello sir do you know how to install software of smartgen control?

  • @user-fu8ie4ze4c
    @user-fu8ie4ze4c 2 роки тому

    thank you

  • @yashargarayev4552
    @yashargarayev4552 Рік тому

    hi. which icon in conroller mean DG running (DG started) ?

  • @kkmaungwin1
    @kkmaungwin1 3 роки тому +1

    Hello...
    For DSE 7320MKII
    Can you please explain oil pressure input (Type: DC6M-2) & coolant temp; sensor (Type: KAIZHOU) how can I set the input value for the shutdown alarms? Thank you

    • @electricalmastar
      @electricalmastar  3 роки тому

      Hi thanks for your comments and for oil pressure and coolant temperature set values you can get it from DG manual

  • @kevster297
    @kevster297 3 роки тому +1

    Hello, how to wire if 3 phase 3 wire no neutral wire?

  • @ahmedwaleed6886
    @ahmedwaleed6886 3 роки тому +1

    Welcome to you and we welcome this good and wonderful channel as wonderful as you are and I hope that you will accept me a new subscriber or a friend of yours and I have a question. And it is ... Does this scheme apply to all models of old and modern dpc screens and the same way of entering and adjusting them manually. How do we get all the old and new dpc programs and are there any One program for it deals with all versions of dpc screens. A thousand thanks and more success, waiting for you to respond with impatience.

    • @electricalmastar
      @electricalmastar  3 роки тому +1

      Thank you so much Mr. Ahamed for your kind words, and yes one software is can able to support all type of dse controller but based on model type its having different functions. For that you need to check your des model catalogue .
      Thank you & keep support our channel

  • @TanveerKhan-bk7sq
    @TanveerKhan-bk7sq 2 роки тому

    Hi dear can you share auto start video

  • @dlewis4647
    @dlewis4647 2 роки тому

    Can you bypass the sensor alarms and still crank engine?

  • @TrisnaWijaya
    @TrisnaWijaya 4 роки тому +1

    hello sir, could you explain what protection we must use when phase angle is different between main bus and DG when syncrone?

    • @electricalmastar
      @electricalmastar  4 роки тому

      Thank you for your comments Mr. Trisha vijaya,
      For synchronization of DG and main supply you can use deep sea controller module 8610 which is having all protection for synchronization.
      For more about synchronization watch this video ua-cam.com/video/dtIwx2zkiS4/v-deo.html

  • @diselgeneratormohsinhayat4722
    @diselgeneratormohsinhayat4722 2 роки тому

    Pls update esm perkins disel series 1300 clustemar conochan pls knolage for all ecm pls 🙏

  • @amkamboj
    @amkamboj 3 роки тому

    Hello Sir
    Can you explain the wiring of PS0500 Cummins

  • @maithemabbas2275
    @maithemabbas2275 10 місяців тому

    ❤❤❤

  • @ChetanJadav1990
    @ChetanJadav1990 3 роки тому +1

    Please help me I have dse 6120mk// showing low oil pressure sender fault in the events log , tried to run genset manual it's not working engine lube oil solenoid shutting off the fuel valve genset stopped working??

    • @electricalmastar
      @electricalmastar  3 роки тому +1

      Thanks for your comments and low oil pressure means chance for oil level may get low or check coolant level is it okay, and finally check sender unit faultiness. This out of 3 option may be chance for gender stopped
      Thank you keep support our channel

    • @ChetanJadav1990
      @ChetanJadav1990 3 роки тому +1

      @@electricalmastar thanks 😊

  • @m.santhanakrishnan990
    @m.santhanakrishnan990 3 роки тому

    thank u

  • @athullamuthunayaka4572
    @athullamuthunayaka4572 9 місяців тому

    Which wire conect reset?

  • @patrickolofia9127
    @patrickolofia9127 3 роки тому +1

    Could you elaborate more on the input 18,19 and 20? I have connected to the DSE 7410 through modem, however I could not able to get pass connecting to module. Do I have to run connect input for this before I can be able to connect to module?

  • @marlontaroma4590
    @marlontaroma4590 3 роки тому +1

    Hi electric master. I have 3x125kva jcb generator failed to sync. The current version of the dse8610mkii is V4.1. I do all the same configuration of this 3 units but still failed to sync. Can you give me some tips boss.thanks

    • @electricalmastar
      @electricalmastar  3 роки тому +1

      Hi
      Thanks for your comments and for sync or parallel operation please check this video it could be helpful for you
      ua-cam.com/video/dtIwx2zkiS4/v-deo.html
      Thanks keep support us

    • @marlontaroma4590
      @marlontaroma4590 3 роки тому

      @@electricalmastar sure. Appreciate. One last thing do I need to update the firmware from V4.1 to 5.1. since I try so many times.thanks a lot

    • @electricalmastar
      @electricalmastar  3 роки тому

      Try for the update may be it will work

  • @josephaoun1088
    @josephaoun1088 3 роки тому

    Hello sir, i have 4 generators running it's been a while. Suddenly, one of the generators doesn't syncronize with others and doesn't get on bus. How should i find what's wrong? What should i check? Thank you

  • @stevenaua9611
    @stevenaua9611 Рік тому

    Deep sea 7510 in AUTO/Manual in runs few seconds it cools down and stops. Why is it doing that?

  • @Manoj_0341
    @Manoj_0341 4 роки тому +1

    Explain about analogue inputs,outputs and digital input and output

    • @electricalmastar
      @electricalmastar  4 роки тому

      Thank you for your comments Mr. Manoj, i will make separate video for input and output configuration
      Keep support our channel
      Thank you

  • @deepthipathiratne6964
    @deepthipathiratne6964 4 роки тому +1

    Please explain how can we parallel CAT 500 Kva EMCP 4.2 controller with deep sea 8610 two sets with main supply

    • @electricalmastar
      @electricalmastar  4 роки тому +1

      Thank you for your comments Mr. Deepthi Pathiratne,
      i will make separate video for DG parallel running with DSE controller
      Keep support our channel
      Thank you

    • @deepthipathiratne6964
      @deepthipathiratne6964 4 роки тому

      @@electricalmastar Sorry, In my case it should be CAT EMCP 4.1 with DSE 8610 and 500 kva dual generators

    • @Manoj_0341
      @Manoj_0341 4 роки тому

      Sir for your kind information if you want synch with main utility then you need DSE 8620

  • @hassanjaber5159
    @hassanjaber5159 8 місяців тому

    please i am seeking for electrical engineer specialist in synchro panel

  • @varadarajanu
    @varadarajanu 4 роки тому +1

    Sir our deep model 7110 problem generator start after 5 mint's solenoid will come stop position ?what's the reason

    • @electricalmastar
      @electricalmastar  4 роки тому

      Thanks for your comments, I think it's problem with stop solenoid coil check it
      Thank you

    • @chubaid3557
      @chubaid3557 3 роки тому

      which alarm show on deep sea may any safety active any input output active there thats why

  • @Skallvideos-hp4ww
    @Skallvideos-hp4ww Рік тому

    Sir, it would have been nice to explain this video in Hindi language too..

  • @rahmatali-zq3jl
    @rahmatali-zq3jl 2 роки тому

    Hello sir sadmack gcu bord repayer hoga

  • @povphanith963
    @povphanith963 3 роки тому +1

    HELLO TEACHER

    • @electricalmastar
      @electricalmastar  3 роки тому

      Hi thanks for your comments and keep support our channel

  • @bluestar6248
    @bluestar6248 2 роки тому

    Can I explain DG645 location of hours sensor

  • @rejisongeorge6144
    @rejisongeorge6144 Рік тому

    How to check RS485 port working

  • @parvejmallick2831
    @parvejmallick2831 3 роки тому

    Sir, i want to know the connection for hours run in this controller

  • @raufkhan159
    @raufkhan159 3 роки тому +1

    I got a massage on DSE controller (6110MHII AUTO START) Ramp up, Safety on delay & waiting for delay. even though the generator is running and given voltage. could anyone tell me why all these massages showing on display.

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments and those msg are inbuilt configuration for safety of device

  • @etiennewandonga1986
    @etiennewandonga1986 2 роки тому

    Thanks
    Anyone knows how to remove the pin on the module?

  • @mantashanabil6619
    @mantashanabil6619 3 роки тому +1

    Perking Engine genararator How to Case lockout Alaram

    • @electricalmastar
      @electricalmastar  3 роки тому

      Hi
      For lockout alarm and all protection relay system has linked with trip circuit that's why when DG get trip lockout relay also get activated
      Thank you

  • @yunasseble8570
    @yunasseble8570 3 роки тому +1

    I got problem with my module was blank unable to reading anything,, any idea sir?

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments
      There is some option called factory reset you can try that one

    • @johnwilliamsawatey6365
      @johnwilliamsawatey6365 3 роки тому

      How can I reset a forgotten password?

  • @hajiamjadali7170
    @hajiamjadali7170 2 роки тому

    How to clear the fault alarm

  • @aldwinrichieortiz7634
    @aldwinrichieortiz7634 2 роки тому

    Hello sir. Can u pls send me a clear schematic diagram of controller to dg.. Thanks

  • @teodoricoromero3648
    @teodoricoromero3648 3 роки тому

    Sir can i request the full conection between ats to genset diagram including battery charger... Thank you

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments sir, and check this Link it may be help you your query
      ua-cam.com/video/17FyXFWRT34/v-deo.html
      Thank you

  • @varadarajanu
    @varadarajanu 4 роки тому +1

    Sir deep sea 7110 model connection same ,

  • @sellakkannupalaniyappan634
    @sellakkannupalaniyappan634 Рік тому

    Hi adeco fault and ECU red mean

  • @kouamefrancoiskouassi6413
    @kouamefrancoiskouassi6413 Рік тому

    Chaque carte électronique modèle APM

  • @lazy_monster_gamerz
    @lazy_monster_gamerz Рік тому

    Does anyone know what is AR and GFR in controller ?

  • @AhmadAli-tl1im
    @AhmadAli-tl1im 3 роки тому +1

    AhmedAli Abro

  • @sijuem
    @sijuem Рік тому

    Where we connect ATS connection

  • @teodoricoromero3648
    @teodoricoromero3648 3 роки тому +1

    Single pole only

  • @3umaransara894
    @3umaransara894 2 роки тому

    bro how to sketchual it ?

  • @shaneefh926
    @shaneefh926 2 роки тому

    Wht is the difference between this and amf, ats

    • @rahulkumarkushwaha1235
      @rahulkumarkushwaha1235 2 роки тому +1

      Amf- auto mains failure ( when mains supply will cut off, diesel Generater will be start automatically)
      ATS ( auto transfer switch)
      When Genset will start it will give load supplies from mains to DG

  • @Imrankhan-rc1xi
    @Imrankhan-rc1xi 3 роки тому

    Dse 7320 controller not updating running hours and stop time the stop signal open close 3-4 times.

    • @electricalmastar
      @electricalmastar  3 роки тому

      Hi Mr. Imran thanks for your comments and if DSE controller not count running hour then reset or reconfigure it then it will work . And if Gen set get continuous trip then check the alarm details in the event page and rectify it
      Thank you

  • @arctonengineering6316
    @arctonengineering6316 3 роки тому +1

    I want to know config swith

    • @electricalmastar
      @electricalmastar  3 роки тому

      Hi
      For switch configuration i have posted another video you can check in the playlist
      Thanks

  • @ritusubodhsharma417
    @ritusubodhsharma417 3 роки тому

    Hello Sir I Want To Know MSc Data Failure Dse8610

  • @vuongvan4788
    @vuongvan4788 3 роки тому +1

    rewe dse6120 đi and

  • @manoranjan4598
    @manoranjan4598 3 роки тому +1

    Hindi plz

  • @bash1338
    @bash1338 3 роки тому

    Please English version is needed for your non Indian speakers

  • @RiazKhan-rl1sl
    @RiazKhan-rl1sl 3 роки тому +1

    Sir this is forget 56 57 58

    • @electricalmastar
      @electricalmastar  3 роки тому

      Thanks for your comments
      Those pins are not required for this module and it's based on module configuration
      Thanks