Combi Boiler with Two Heating Zones, 230V Switching

Поділитися
Вставка
  • Опубліковано 21 січ 2025

КОМЕНТАРІ • 187

  • @simonelson7043
    @simonelson7043 10 місяців тому +6

    A fantastic yet simple explanation of multiple heating zones.
    Many thanks John from all learning this.

  • @mattfreeman3058
    @mattfreeman3058 4 роки тому +38

    Probably the best explanation of wiring zones valves I have heard

    • @MrErnogoldfinger
      @MrErnogoldfinger Рік тому

      I was really impressed too. The marker drawing/diagram was basic but very effective

  • @farukm7627
    @farukm7627 10 місяців тому +2

    Thank you for a most thorough but concise and informative explanation JW.

  • @solidus784
    @solidus784 4 роки тому +12

    I'm a sparks and I know this stuff inside out and I'm still watching these vids says a lot for the channel.

  • @saqibch5896
    @saqibch5896 4 роки тому +12

    JW - is by far the most concise teacher. ( Thank You John W. For this Great Video )

  • @tonyenrico9350
    @tonyenrico9350 6 місяців тому +1

    At last!!! Thanks be to God and you. I can't believe I found exactly what I needed after more than one week being searching every day. Just as a no native English speaker very hard to catch up your fast speaking. Thank you

  • @satsumo
    @satsumo 2 роки тому +1

    The best video going when it comes to understanding the wiring of a 2-port valve. Who would have thought brown doesn't go to brown!?!! Thank you :)

  • @leecrook6918
    @leecrook6918 2 роки тому +4

    Clear, concise and straight forward explanation. Best one on YT. 👍🏼

  • @markjhorsley
    @markjhorsley 4 роки тому +3

    This helped me understand what was going on in the wiring centre, disconnect my old stat (at both ends) and add in a hive receiver next to the centre - great video, thanks

  • @andrewcross8892
    @andrewcross8892 4 роки тому +3

    Amazing. I’m a sparky and still benefited greatly from your explanations and delivery. Thanks.

  • @keithminnican2386
    @keithminnican2386 Рік тому +2

    Brilliant tuition and video John, very well presented and animated, best on the internet, helped me instantly, thank you!

  • @50shadesofgrade
    @50shadesofgrade 4 роки тому

    John ward - Aka - JW - is by far the most concise teacher and greatest electrician on the net.
    Anytime im stuck - JW - pulls me from the muddy waters.
    Thanks JW 1UP

  • @thomasevans8944
    @thomasevans8944 3 роки тому

    most easiest to understand explanation of wiring controls ever

  • @mickyd6139
    @mickyd6139 3 роки тому +1

    John, you're explanations are superb. Really first class stuff. The paxman like delivery is a bonus too :-) . Thanks.

  • @newgamer85
    @newgamer85 4 роки тому +2

    I love your vids. Trying to be a sparky for many years even tho passed out NVQ 1-2-3 2010. Could not get proof of work done as lack of interest from sparks if your over 19 slave labour rate.
    Sorry for rant. Anyway your vids are so good and helpful for some one who has little time on the tools but still interested in staying relevent.
    You really are a valuable source thank you.

  • @willcpfc4720
    @willcpfc4720 2 місяці тому

    Absolutely fantastic. Easily the best diagram and explanation . 👍🏻

  • @all4heatinggaslimited40
    @all4heatinggaslimited40 2 роки тому

    Thank you John
    For explaining how to zone on 230 volts.

  • @209jtyler
    @209jtyler Місяць тому

    Thank you so much for this video! Really helped me when it’d confused myself which the wires!

  • @michaelgallagher999
    @michaelgallagher999 3 роки тому +2

    Thanks for this video, it completely helped me wire 2 zones to a combi!

  • @andynelmes5133
    @andynelmes5133 4 роки тому

    Am a plumber but just couldn’t find a good diagram for adding underfloor heating to Combi with two zone valves and modern 230v programmable thermostats.... thank you, after five mins watching, my brain clicked into gear... the wiring diagrams I had still don’t make sense but it’s all working now thanks to you...

    • @vladimirstafasani4630
      @vladimirstafasani4630 3 роки тому

      Hi Andy,
      I am looking for the same thing connecting underfloor heating to combi but not sure how to do it. I would very appreciate it if you could let me know how you did it. Many thanks

  • @muradkhan6787
    @muradkhan6787 9 місяців тому +1

    Excellent information

  • @Benzz90
    @Benzz90 2 роки тому +1

    Excellent explanation, I have never worked with a boiler or any electrical wiring other than dashcams and the odd splice into a car live wire for some 12v power.
    After watching your video, I was able to setup zone 1 of my Hive Dual Zone heating to replace my current thermostats, took me around 40mins including stripping/trimming cables, now I just need to cable tidy and then do the second one!
    Really appreciate this video and diagrams, very informative and right to the point.
    Hive wanted £175 for this install, all I need is a little trunking but the rest is neat so i'm happy! :) - Anyone reading this comment thinking of having a go, just make sure you invest in an electrical tester to make sure the switch is isolating the circuit correctly as explained in this video, better safe than barbecued!

  • @happyeaster3311
    @happyeaster3311 3 роки тому

    This could be sold as a training video!!! Thanks JW!

  • @jambai1712
    @jambai1712 4 роки тому +1

    Brilliant very professional and well set out. Best one on UA-cam keep it up 👍👍

  • @marvasika2964
    @marvasika2964 4 роки тому +1

    Amazing. Great clear and thorough video. Thank you

  • @derekhenderson3405
    @derekhenderson3405 Рік тому

    Excellent video. Just what I needed.

  • @TheLife0025
    @TheLife0025 2 місяці тому

    Hello. How can we connect boiler to wiring centre if it is on a distance in the middle of the house with manifold.? Do we need a long wire.?

  • @Aliens4world
    @Aliens4world 2 роки тому

    Understood up to the part of connecting first three wires brown blue earth. After that is become complicated. Also which wires to use 1.5mm2 ???

  • @donone7686
    @donone7686 9 місяців тому

    Dose the same principle apply if your second zone is underfloor heating?

  • @robinstokes5179
    @robinstokes5179 4 роки тому

    Very clear explanation / description. No programmer is shown in this. Not often mentioned in various explanations available (which often show a HW. cyl stat); is that most /all combi systems have no HW cylinder or stat & the boiler supplies HW on demand. I assume a combi's HW output is triggered by an internal flow valve; you turn tap, water flows, flow switch operates, boiler fires. All that is needed are the zone stats to fire the CH as shown in your video plus a timer/programmer to automate CH. The HW side of the programmer is unnecessary in this set up.

  • @Glund1991
    @Glund1991 9 місяців тому

    Having an issue with our central heating system. I have a brand new thermostat, and dual zone heating. The heat pumps both work as I can wire them each to the upstairs thermostat which works but I cannot get the downstairs thermostat to call for heat even though it ‘clicks’ when turned up.
    Any ideas what this could be?

  • @raydaveyrd
    @raydaveyrd 2 роки тому

    If I wanted to move a radiator from one heat zone to the other and the radiators share a wall with pipes inside. Can I just daisy chain or will I need the floors up...

  • @ZafarKhan-qh1zi
    @ZafarKhan-qh1zi Рік тому

    You are a great teacher 🎉🎉🎉

  • @eduardocampos2022
    @eduardocampos2022 3 роки тому

    John, you are the best 👏🏼👏🏼👏🏼👍🏼

  • @ivandrozd8262
    @ivandrozd8262 4 роки тому

    Well explained. Thank you John, you're could be a good training teacher!

  • @zaksystems
    @zaksystems Рік тому

    Can you add the open therm wiring for one of the valves in a 2 zone system

    • @pineappleroad
      @pineappleroad Рік тому

      As far as I know, opentherm would not be possible with a multi-zone system, as opentherm takes over control of the boiler (opentherm is a digital connection that goes straight to the boiler from the thermostat)

  • @mihaivilceanu9887
    @mihaivilceanu9887 2 роки тому

    Thank you very much, you’re the best !!! Very good explanation and made a lot of sense.

  • @AB-oc5lj
    @AB-oc5lj 4 роки тому +1

    Excellent as always! Thank-you.

  • @dumma56
    @dumma56 Рік тому

    Great video, very clear. The issue I have at a client's property is that the wiring centre is at the opposite end of the house from the boiler and where the new Hive reciever would be. Currently there is only a 3 core and earth from the boiler/reciever area to the wiring centre which leaves me 1 core short. Would it be possible to supply the L,N and E to the pumps locally at the wiring centre ( fused down ) and use 2 of the cores in the existing 3 core and earth plus the earth as the switch cores? this would mean that there would be 2 circuits at the wiring centre. I would clearly label this at both ends but Im just wondering if it is ok or a total no no? Thanks in advance.

  • @MetalAlz
    @MetalAlz Рік тому

    How would I remove the second zone? We have a very small second zone in our bedroom and ensuite that we do not use as the thermostat makes a big CLUNK when it turens on or off and wakes me up! I'd rather have the entire house come on and off together.

    • @jwflame
      @jwflame  Рік тому +1

      Find the brown wire for the zone valve in the wiring centre and connect it to the brown wire for the other zone valve. They will then both work together from the same thermostat.

  • @dontthinksosomehow
    @dontthinksosomehow 3 роки тому

    Had to wire a combi to a cylinder as well as central heating through 2 x2 ports 10 years ago, what a head scratcher that was, had to run it through a relay switch if I remember correctly.

    • @JasperJanssen
      @JasperJanssen 2 роки тому +1

      Should basically just be the same only with three zones instead of 2. Unless you want hot water priority, (ie if hot water is demanded then heating is off). In that case you’d do something fancy with the NO and NC contacts of the hot water thermostat contact. Specifically, the power that goes to the heating side of the system should be on the NC side of the hot water thermostat, so the whole heating side turns off when the water is demanded.

  • @iiiiiiicurtisiiiiiii
    @iiiiiiicurtisiiiiiii 3 роки тому

    Could you connect the grey and brown wires together at the 2 port valves, and then ditch the perm live to the valve? You would still have the ability to switch on the boiler with the postition switch within the valve, however it would be fed from the programmer not the main live. You would then only need 3Core + Earth cable

  • @StevenSummers-on6uy
    @StevenSummers-on6uy 2 роки тому

    Hi John I have a Greenstar combi CDI with comfort 11 RF installed, following your diagram to the letter.
    everything plumbed and wired.
    Looking at the boiler wiring I find that LS is linked to LR so I am now stuck as when to put the orange wires from the 2 port valves.

    • @jwflame
      @jwflame  2 роки тому

      The link is removed, the orange wires connect to LR.
      The link is there so that the boiler will run all the time when heating is selected on the front panel, it's intended for testing purposes only when the boiler is installed.

  • @markjhorsley
    @markjhorsley 4 роки тому

    Just what I was after - great vid

  • @asifk159786
    @asifk159786 Рік тому

    Great video. I'm wiring ideal vogue what changes would I need to make for the set up to work?

  • @sauliusban
    @sauliusban 3 роки тому

    Based on this can you add Unvented cylinder instead ?

  • @delliestheelephant350
    @delliestheelephant350 2 роки тому

    On a 2 zone combi system. Could both valves be removed and pipe work bridged where the valves are removed and a simply receiver and stat be added directly to the boiler for call for heat without altering any other pipework?

    • @jwflame
      @jwflame  2 роки тому

      Yes, it would just end up as a standard combi boiler installation.

  • @darrenharley6150
    @darrenharley6150 4 роки тому

    Will the central heating thermostat be able to switch an external heating pump on directly aswell as the boiler. I have a combi boiler and I think the internal heating pump is not powerful enough to pump water around the house. I want to put an external pump in the system but need it to be controlled so it turns on and off and not powered all the time. Looking at the circuit diagram on your video, instead of having zone valves can the thermostat control the external pump the same I.e when thermostat is turned to required temperature the pump starts.
    Thanks

  • @arturasd570
    @arturasd570 Рік тому

    Brilliant explanation 👏

  • @danh5052
    @danh5052 Рік тому

    Do the end switches “make” if you have no power and simply push over the lever to manually open the valve?

    • @jwflame
      @jwflame  Рік тому +1

      No. The manual lever only opens the valve partially, should only be used when filling or draining the system.

  • @hamaadrana6191
    @hamaadrana6191 Рік тому

    Hi great help you are!
    If I had an underfloor heating pump how would I wire it in? If it’s 3 core without it being on all the time?
    Thanks

    • @jwflame
      @jwflame  Рік тому +1

      E&N to the earth and neutral terminals. L to the switched output of the thermostat (3 in the diagrams, also the same as the brown valve wire), so the pump only runs when heat is required for that zone.

    • @hamaadrana6191
      @hamaadrana6191 Рік тому

      @@jwflame thanks mate

  • @tombola9445
    @tombola9445 8 місяців тому

    Hi JW, On pin 9 when both stats call for heat, why doesn't the voltage from both valves either add to create 440v assuming they are in phase or cancel to 0v if there's a 180deg phase shift introduced, with the first point being most likely.

  • @RobinWhistles
    @RobinWhistles 3 роки тому

    I've a buffer thermal storage tank. I need to turn on a load when top stat drops to 45c and not turn off until bottom stat reaches 50c. Can anyone tell me what device I need to do this? tia

  • @dezire8470
    @dezire8470 23 дні тому

    Would this still be the same if it’s an S plan. Except from having a programmer, separate hot water valve and a cylinder stat?

    • @jwflame
      @jwflame  22 дні тому

      Yes, any boiler can be connected to S plan or any other arrangement. Only difference is that some combination boilers do not have a 230V switched input so a relay or alternative wiring arrangement will be required. For those with 230V inputs, it's exactly the same.

    • @dezire8470
      @dezire8470 22 дні тому

      @@jwflame okay thanks. We’ve got some heating issues Mine is just a regular S plan system boiler. With hot water and heating valves But I live above a pub which has multiple heating zones and multiple 2port valves also. They come from one boiler

  • @arinb12
    @arinb12 Рік тому

    John! How might this work if i then introduce a 3 way zone valve for hot water in if we were using a system setup?...

    • @jwflame
      @jwflame  Рік тому

      It doesn't. No one should be installing new Y plan / 3 port valves, they are only suitable for a system with hot water and a single heating zone, nothing else.
      To add more zones or a hot hot water cylinder, it's another thermostat and a 2 port valve.
      Other videos covering those: ua-cam.com/play/PLVsHvs2Suqmr5HtxgbInR4bXmH0kLseWc.html

  • @gilbertlufc
    @gilbertlufc 10 місяців тому

    Excellent explanation. Thank you.

  • @hutchrp
    @hutchrp Рік тому

    Currently considering switching to tado smart heating. Have ESI wiring centre plug and play in at the moment (new build). Need to swap to a more analog wiring centre. 2 zones. Combi. Will this work?

  • @jimmyclark8229
    @jimmyclark8229 2 роки тому

    Hi , I have this system , I have 2 ESI programmable room stats . I would like to put open therm connected to my system , any idea what would be involved to do this , thanks

    • @pineappleroad
      @pineappleroad 6 місяців тому

      Opentherm with multiple thermostats is not possible to do unless they are wireless ones that share a single receiver (as opentherm uses digital communication between the thermostat and boiler, and it isn’t designed to allow multiple thermostats, with wireless thermostats, only 1 wireless receiver can be connected to the boiler using opentherm, and you cannot wire a second thermostat/reciever up without getting strange behaviour, such as the boiler only running when BOTH thermostats are calling for heat, or the boiler only responding to one thermostat, or perhaps even the boiler showing error codes and/or not responding to either thermostat)

  • @rpspivey
    @rpspivey 3 роки тому

    Fantastic explanation JW thank you so much.

  • @norris5353
    @norris5353 11 місяців тому

    Hi John, just what I was after, Great, Thank you. Same principle as your diagram etc but one circuit will be radiators, the other will be for UFH in a single zone. I'm just a bit confused as to where the return pipe would fit into this as 2 separate circuits? Would I need a third 2 port valve for the UFH return and just two 2 port valves on the flow side, one for UFH and one for Rads as per your diagram? Kind regards, Paul

    • @jwflame
      @jwflame  11 місяців тому

      The return pipes just join together, no valves required.

    • @norris5353
      @norris5353 11 місяців тому

      @@jwflameTHANKYOU! I did consider that but won't UFH return interfere/mix with Rad return as that's on different circuits with diff pressures? So in a nutshell, the same as your diagram? Cheers, Paul

  • @andreiturcan9692
    @andreiturcan9692 2 роки тому

    Hi, I have this type of set up on my system. But I cannot control zone two independently. Boiler receives the signal, the burner starts and goes off quickly. Valve 2 is opened but I have no flow inside radiators. CH flow is hot but CH return is cold. But when zone 1 calls for heating both zones are heating. Any clues?

    • @jwflame
      @jwflame  2 роки тому

      If this is a new problem then most likely is a blockage or air lock on zone 2 somewhere.
      If it's always been like that then incorrect pipework is also possible.

    • @andreiturcan9692
      @andreiturcan9692 2 роки тому

      It has been always like that.

    • @andreiturcan9692
      @andreiturcan9692 2 роки тому

      The idea is that from boiler outlet when zone 2 asks the water doesn’t leave. It is cold. Only when zone 1 kicks in outlet is hot straight away

    • @andreiturcan9692
      @andreiturcan9692 2 роки тому

      And wire 9 is always live. But boiler is not working

  • @eumesmo-kd1tr
    @eumesmo-kd1tr 4 роки тому +1

    I really enjoy your work, BR

  • @7dayplumbingservices195
    @7dayplumbingservices195 2 роки тому

    Brillant video , thanks . I am in a process of connecting an UFH ( zone 1) and radiator system (zone 2) I am using 2 2port valves as the UFH is only 1 large room , 2 hive thermostats , I am struggling to understand where to wire the UFH pump . any videos of yours available on that subject ?

    • @jwflame
      @jwflame  2 роки тому +1

      For a single UFH zone, the pump is wired to the thermostat switched output, so it runs at the same time that the valve is open. Terminal 7 or 8 in the diagrams in the video.

    • @7dayplumbingservices195
      @7dayplumbingservices195 2 роки тому

      @@jwflame many thanks it makes perfect sense

  • @celotexsurfer6127
    @celotexsurfer6127 Рік тому

    Great video, one question if one zone is an underfloor zone with an additional pump would you take the sw live from the zone valve?

    • @jwflame
      @jwflame  Рік тому +1

      UFH pump is connected to the thermostat for that zone, so it only runs when that zone requires heat. Thermostat 3 in the diagram, which is also the brown wire for the valve.

  • @teocalvin5873
    @teocalvin5873 3 роки тому

    Sir, what type of cables be used in boiler electrical wiring, please. Thank you.

    • @jwflame
      @jwflame  3 роки тому

      Heat resistant PVC flex, 0.75mm² would be the usual choice. 3,4, or 5 cores depending on what is being connected.

  • @rizdean9530
    @rizdean9530 4 роки тому

    Very clear and professional video. I have a couple of questions pls. 1) which brand wiring centre would you recommend for Hive, and 2) I am trying to understand how the bypass will be installed (or what it looks like pls in a setup). Thank you ever so much

  • @1000hillas
    @1000hillas 4 роки тому

    Brilliant John.
    Great video. Thanks

  • @VipPatel-x8r
    @VipPatel-x8r 4 місяці тому

    The boiler I’m connecting to doesn’t have a switch live just 2 connections for thermostat it’s a baxi duotec

    • @jwflame
      @jwflame  4 місяці тому

      See this video for connections to that type of boiler: ua-cam.com/video/nOQ8ZEhSLDI/v-deo.html

  • @MrMickrobo
    @MrMickrobo 3 роки тому

    Hi sorry to be i bit cheeky John I'm stumped I have been searching for a wiring dia. for a system with Keston c40 with two switched live, one for heating and other hot w. I had an oversized cylinder made up with a solar coil and heating coil high and low immersion bosses and used it in an extension I built so have two cylinders now, I have two heating zones two-pipe and underfloor with Danfos radio linked stats with their own timers built-in, I want all four zones independent and I am ok with two programmers, any idea where to look for guidance, been in the heating industry for 30 years but pulled a blank on this one. I'm retired on ill-health for some years so out of touch with colleagues to draw from, any help will be appreciated Cheers Mike R.

  • @rodgerq
    @rodgerq 3 роки тому

    Excellent video, well explained!

  • @Duggy171
    @Duggy171 29 днів тому +1

    excellent video, thanks

  • @matthewhantschar8408
    @matthewhantschar8408 3 роки тому

    Is it possible to have a 24v thermostat connected to the zone valve controlling the radiators and a 230v stat connected to the zone valve controlling the u/floor heating on the same combi boiler?
    It’s a valliant combi.
    I’m pretty sure I can but just wanted some reassurance 😁

    • @jwflame
      @jwflame  3 роки тому

      If the 24V thermostat just uses 24V for power and has volt free contacts, then it could be used, the thermostat contacts would switch the 230V for the zone valve as in the video.
      If the thermostat switched output is also 24V, then it would would require a relay with a 24V coil, the 24V thermostat would power the relay coil and the relay contacts would switch the 230V power to open the valve.
      In both cases the thermostat would require a 24V supply from somewhere.

    • @matthewhantschar8408
      @matthewhantschar8408 3 роки тому

      @@jwflame thanks for the reply, keep up the great work 👍🏻

  • @kevinmchugh5229
    @kevinmchugh5229 9 місяців тому

    Thanks Dude. Love your vids.

  • @kevalpatel5685
    @kevalpatel5685 2 роки тому

    Thank you for lovely explanation really helpful video

  • @henri7753
    @henri7753 Рік тому

    As this is a combi boiler, what happens to DHW when there is no heating demand and the boiler is off?

    • @jwflame
      @jwflame  Рік тому

      Combi boilers should be left powered all the time, it will wait in standby until a hot tap is opened.
      If it's switched off at the front panel or has no power, then there will be no hot water.

    • @henri7753
      @henri7753 Рік тому

      @@jwflame I'm confused. I thought your wiring diagram applied to a combi boiler as per the title?

    • @jwflame
      @jwflame  Рік тому

      @@henri7753 Yes, it applies to combination boilers. Those which heat water on demand when a hot tap is opened. There is no external wiring or controls for the hot water.

    • @henri7753
      @henri7753 Рік тому

      @@jwflame I had misunderstood the Switched Live in the diagram, I thought when there was no power to SL, then the boiler was off.
      So the wiring for combis is exactly the same as for system, except that the hot water cylinder is missing here (but could always be added)?

  • @stephenrenshaw7288
    @stephenrenshaw7288 2 роки тому

    Hi if one zone was underfloor heating what would pump be wired to?

    • @jwflame
      @jwflame  2 роки тому +1

      UFH has it's own pump, which for a small single zone would be connected to the thermostat for the UFH.
      For larger installations with multiple zones, the UFH pump is connected to a dedicated controller/wiring centre for the UFH together with the thermostats and zone actuators.

  • @mrluke19862
    @mrluke19862 2 роки тому

    Hi Quick Question , If Zone 2 was a UFH system ( pump & Actuators ) would i attach their 230v Power To point 8 ? on the diagram . So they would switch off when the Hive is turned off ? .
    Would this also work if Zone 1 and 2 was on at the same time and i turned off the UFH/Zone2 ( would the Pump and UFH turn off ) ( I assume they wouldnt be getting any power from the orange ? )

    • @robday3968
      @robday3968 2 роки тому

      I have the same question.

    • @mrluke19862
      @mrluke19862 2 роки тому

      @@robday3968 Rob , I converted my single zone to dual zone ( UFH and Radiators ) last weekend . From my UFH wiring i had a Brown & Grey wire ( Brown Sleeve ) . These both connected to point 8 on the diagram . This then meant the pump and actuators turned off with the zone . My setup was using two Hive thermostats .

  • @adamtambe5871
    @adamtambe5871 3 роки тому

    Spot on explanation really helpful

  • @sk83rboy00
    @sk83rboy00 3 роки тому

    Will this work with valiant ecotec plus 832 Combi boiler? It has connections ‘RT’ next to ‘LNPE’ inside this boiler. The RT connection has 2 terminals though? This is a 2 zone system with the Drayton 230v ZA5 2-port valve. I am also installing 2 thermostats, they are the danfoss TP5001M 230v with V/F output. I am right in saying the switch line to the thermostat will connect to normally open contact? Great video by the way, any advice would be appreciated!

  • @stephenc9131
    @stephenc9131 2 роки тому

    Where would you wire the pump in this diagram

    • @jwflame
      @jwflame  2 роки тому

      Nowhere, a combination boiler has the pump as an internal component.

    • @stephenc9131
      @stephenc9131 2 роки тому

      @@jwflame thanks John. I should of said mine is a condensed boiler.
      In addition I have two 2port valves s plan zones. Heating downstairs is one zone and heating upstairs is the second option. If I leave both valves closed or the switches on the wall off, the boiler once on, it just heats the water. Is there any diagram available to wire my hive to my system as I’ve tried to describe

  • @Aliens4world
    @Aliens4world 2 роки тому

    Thx so much…i was searching for this…

  • @CsöszakiHoszivattyu
    @CsöszakiHoszivattyu Рік тому

    Just find this video very good explanation. I wish someone make video about 2 zone heating with 2 pump or more with Relay to stop backfeed one for other. Always confuse me that systems 😂

  • @mister_cjw
    @mister_cjw 3 роки тому

    This is really good. Thank you.

  • @DavidWilliams-ce2er
    @DavidWilliams-ce2er 2 роки тому

    Fantastic video, thank you. Would it be possible to use a 3 port valve instead of two 2 ports?

    • @jwflame
      @jwflame  2 роки тому +1

      Not without extra components and thermostats which had both on and off connections.
      3 port valves were designed decades ago for one type of installation - a hot water cylinder and a single heating zone.
      They are of little or no use for anything else.

  • @Wolves260ldn
    @Wolves260ldn 3 роки тому

    hi John. thanks a lot, helpful stuff. The plumber has attached an extra Wilo Para pump to the zone 1 side (to help with underfloor heating). Would I attach the live (of the pump) to number 9 in the wiring centre? (the pump only has L,N and E) That way, it would come on when called for by thermostat receiver 1? or is the incorrect? anyway else could help too? thanks

    • @jwflame
      @jwflame  3 роки тому +1

      No, if connected to 9, that pump will run when the boiler is on regardless of which thermostat is used. If it's for zone 1 only, connect it to 7, which is the switched output of that thermostat only. Numbers refer to the diagram in the video, your installation may have a different arrangement.
      The UFH pump should be part of a manifold with a mixing valve, so it only pumps water for the UFH, and nothing else.

    • @Wolves260ldn
      @Wolves260ldn 3 роки тому

      @@jwflame thanks a lot 👌🏻

  • @Skelton1996
    @Skelton1996 8 місяців тому

    Is there no programmer used with combi boilers?

    • @jwflame
      @jwflame  8 місяців тому

      There can be, however most recent installations would have a combined timer/thermostat. Older ones usually had a timer built into the boiler itself with an external thermostat.
      However entirely possible to have a separate programmer/timer and thermostat wired external to the boiler as shown here: flameport.com/electric/central_heating/combination_boilers_programmer.cs4

  • @davidjenkins9842
    @davidjenkins9842 2 роки тому

    Another excellent video...

  • @martinh7693
    @martinh7693 3 роки тому

    Will this working with wireless receivers/thermostats??

  • @errickmagar3928
    @errickmagar3928 4 роки тому

    Diagrams and instructions are very precious and clear I wonder if there are any possibilities of wiring zone valve and 3 port motorised valve in a single wiring centre. While I was on unvented course the instructor told me we could wire two different valves but I like to know how. It will be very grateful if you could made such video please?
    Thank you JW

    • @jwflame
      @jwflame  4 роки тому +1

      www.flameport.com/electric/central_heating/heating_wiring_Y_plan_unventedHW.cs4

    • @errickmagar3928
      @errickmagar3928 4 роки тому

      @@jwflame cannot thank you enough for that Sir.

    • @millomweb
      @millomweb 4 роки тому +1

      It'd be better with ONE 3-port valve instead of 2 two-port valves. Quite possibly in upstairs downstairs case, heating on both likely not necessary. If they are both needing heat, another switch is required to allow the 3-port valve to return to its mid position.

  • @mikearthur2586
    @mikearthur2586 2 роки тому

    brilliant explanation. thank you.

  • @vladimirstafasani4630
    @vladimirstafasani4630 3 роки тому

    That’s a great video thank you. Would it be the same for underfloor heating zone valve instead of two central heating zone valves? If so how would I connect the pump wiring?
    Many thanks

    • @jwflame
      @jwflame  3 роки тому +1

      The valve is the same. If it's just a single zone, the pump is wired to the switched output of the thermostat, the same terminal as the brown wire to the valve.
      For systems with multiple UFH zones, a separate UFH controller would be used, which will have connections for the pump, actuators and thermostats.

    • @vladimirstafasani4630
      @vladimirstafasani4630 3 роки тому

      @@jwflame thanks very much John much appreciated

  • @olinqua1
    @olinqua1 2 роки тому

    Great clear video, but,What about the programmer on this same layout ?

    • @jwflame
      @jwflame  2 роки тому

      If you want a separate programmer the switch contacts for it connect between terminal 1 and 2 instead of the link. Could also be a timer built into the boiler. Thermostats would then be basic types with no time settings.
      Better to have programmable thermostats and no separate programmer/timer as that allows independent control of each zone, rather than the old ways of 'it's 6pm so turn the heating on'.

    • @olinqua1
      @olinqua1 2 роки тому

      Ok thanks, so do away with the programmers, I run the heating 24hrs anyway as I’ve go u/f heating downstairs. I wondered why it’s not included as every system I’ve seen has a programmer

    • @olinqua1
      @olinqua1 2 роки тому

      Also I need to wire in the U/F pump, should it go in with the zone valve orange wires
      Thanks, I guess your a very busy person
      I’m a builder and Had 2 sparkys trying to work on my C/H wiring but still not correct

    • @jwflame
      @jwflame  2 роки тому

      UFH pump is wired to the thermostat switched output (brown valve wire) so thermostat on = valve open and UFH pump on. If it was connected to the orange, it would run all the time the boiler was on even when UFH was not required.
      Alternatively a dedicated UFH controller can be used.
      If you use thermostats only and no programmer, the thermostats should be programmable types so different temperatures can be set for different times of the day, typically lower overnight or when the property is not occupied.
      Programmer and separate thermostat is the old method, where heating was only used for certain times and not at all for others.

  • @Stevo3032
    @Stevo3032 4 роки тому

    John. Could you please explain what a dry contact is please? Thanks in advance

    • @jwflame
      @jwflame  4 роки тому +4

      Switch contact that doesn't have any voltage connected to it.
      Like the thermostat contacts in this video before the link between L and 1 was installed.
      Also called 'volt free'.

  • @tinytonymaloney7832
    @tinytonymaloney7832 4 роки тому

    Hey JW, due to building works at home I am having to use the immersion heater now to heat water for about 5 months.
    Is it cheaper to leave it on permanently being controlled by its start or only use the immersion on demand.
    Has anybody ever carried out a proper study on this with real figures and temperatures??

    • @jwflame
      @jwflame  4 роки тому +1

      It's cheaper to switch on when hot water is required, as when the water is hot, the losses from the hot water cylinder are greater, as the temperature difference between the water and the outside environment is also greater.
      The saving will be largest with an old, poorly insulated cylinder where hot water is only required for a certain time each day, so most of the time the cylinder is cold.
      However with a modern well insulated cylinder the losses are small, and if large amounts of hot water are required (so the water is hot most of the time), then the difference between heating when needed and on all the time is insignificant.

  • @rowles13
    @rowles13 4 роки тому

    Excellent explanation.

  • @ShadowzGSD
    @ShadowzGSD 4 роки тому

    just what i am about to do, one for the kitchen and bathroom and one for the rest, only need the kitcen and bathroom most of the time as wood burner does the rest.

    • @millomweb
      @millomweb 4 роки тому

      It'd be better with ONE 3-port valve instead of 2 two-port valves. Won't need an automatic bypass for pump overrun and means only need to wire one valve in.

  • @Hobsltd
    @Hobsltd 3 роки тому

    Mate you a legend

  • @Razz60
    @Razz60 4 роки тому +1

    Thankyou very much very well explained

    • @millomweb
      @millomweb 4 роки тому +1

      It'd be better with ONE 3-port valve instead of 2 two-port valves.

  • @mister_cjw
    @mister_cjw 3 роки тому

    This is a great overview. One thing that's always confused me (as a lay person), is the circuit route (thermostat -> wiring board -> boiler) carrying the actual power for the boiler itself? Or just enough power to 'activate' the boiler, which then draws running power from an independent connection?

    • @jwflame
      @jwflame  3 роки тому +1

      The thermostat is just an on/off signal to the boiler. Also note that this wiring is intended for gas or oil boilers, so the electrical power used is only for the pump and controls, typically under 100 watts.
      Electric boilers do exist, they would have a separate high power connection for the heating elements, with the thermostat wired as here, just for on/off control.

    • @mister_cjw
      @mister_cjw 3 роки тому

      @@jwflame Thanks. I actually forgot it's gas combustion that's heating the water, not electricity!

    • @wittywoo9559
      @wittywoo9559 Рік тому

      ​@jwflame hi do you have a video on a combi boiler with ufh manifold & room stats

  • @alessboland5280
    @alessboland5280 3 роки тому

    Hi John, great video can you help on external 3 channel programmer to Worcester gas
    Thanks
    John