Earth Resistance Measurement

Поділитися
Вставка
  • Опубліковано 7 жов 2024

КОМЕНТАРІ • 26

  • @belaoram5994
    @belaoram5994 9 місяців тому

    Thanks sir.. explanation is good

  • @prasnthvarma9253
    @prasnthvarma9253 3 роки тому +2

    Good job sir

  • @sureshmt2467
    @sureshmt2467 Рік тому +1

    Nice explain

  • @vmohankumar7528
    @vmohankumar7528 3 роки тому +3

    Thanks sir 🙏🙏🙏

  • @sriharihari3028
    @sriharihari3028 4 місяці тому

    What the earth resistance value should be... Its less than3 ohm

  • @ProtonSapien
    @ProtonSapien 3 роки тому +4

    Excuse me Raja Sir, a doubt,
    Although you're fixed the electrodes equidistantly, why the value of resistance keeps oscillating? Whether we are able to arrive at a stationary point there?
    I couldn't make out it.

  • @karthik.r1981
    @karthik.r1981 Рік тому

    Super sir

  • @janardanbagkar5153
    @janardanbagkar5153 2 роки тому

    Thanks sir .

  • @kaleeswaranarumugam6658
    @kaleeswaranarumugam6658 2 роки тому

    Thank u sir.

  • @harishpoola4286
    @harishpoola4286 3 роки тому

    Good explanations sir

  • @nasruddinsiraj4083
    @nasruddinsiraj4083 Рік тому +1

    It's not stops eat right.....

  • @tsivaramakrishna8941
    @tsivaramakrishna8941 2 роки тому +1

    Sir what is the diameter of the two electrodes

    • @30mAkills
      @30mAkills Рік тому +1

      Diameter and depth of spikes are not that important. Can use 8 mm steel rod of about 200 mm long like screwdriver.

  • @sheesh1706
    @sheesh1706 2 роки тому

    Why did you short E1 and P1?

    • @30mAkills
      @30mAkills Рік тому

      4 pole meter is for measuring soil resistivity which is different subject. For testing earth pit resistance, we have to convert it to 3 pole by jumpering or linking P1 and C1.

    • @sheesh1706
      @sheesh1706 Рік тому +1

      ​@@30mAkillsCan you recommend some reading matter on the subject

  • @sandranagamuneiah8142
    @sandranagamuneiah8142 3 роки тому

    Thanks sir

  • @solastygunplay
    @solastygunplay Рік тому

    I need it please

  • @rajutitanium417
    @rajutitanium417 3 роки тому +2

    In that meter, one is 10 ohm and 100 ohm what does it mean

  • @rajutitanium417
    @rajutitanium417 3 роки тому +1

    This reading 13 & 16 having any unit

  • @soubhagyanaik4414
    @soubhagyanaik4414 2 роки тому +1

    Sorry Sir, kindly speak Slowly and Clearly english language. Why reading is always variable

  • @30mAkills
    @30mAkills Рік тому +1

    Sorry uploader. Your method is absolutely incorrect as the spike spacings are not as per Fall of potential method.
    You didn't mention the depth of the earth electrode under test.
    You didn't tell whether the earthing system is energized or not.
    You didn't mention the ideal resistance value.
    Shows you don't have practical knowledge. Earthing is done for safety reasons. Don't please misguide.
    That log book tabulation is wrong.
    35 k views and nobody has pointed out the mistakes because they don't know. We real testers won't reveal the proper method. This is the reason that nobody (domestic and commercial services) check their earth pit resistance value.
    You didn't tell about RCCB and TT earthing system.