      Hi sir, what is the control methodology to control the fans of the air cooler chiller based on load ?
      Also what is general control methodology to for controlling the compressor of air cooled chiller based on load ?

  • @1991elliot
    @1991elliot 6 років тому +13

    Some great videos Paul. One thing that is not mentioned here is regarding the size of the heat exchanger - because it is sized for the peak load, when running at part loads the flow still goes through the same heat exchanger but at lower velocities. Reduced velocities equate to lower Reynold's numbers (a measure of how turbulent the flow is) - the higher the Reynold's number the better the heat transfer and hence efficiency. If the Reynold's number is low enough the flow is laminar and there is a significant reduction in performance. Hence operating at part loads causes a loss in efficiency as the heat exchanger is essentially oversized. This can also cause the heat exchanger to foul up more quickly as the particles that cause fouling can drop out more easily and stick to the surface of the heat exchanger. The only way to improve this is to have multiple heat exchangers that can be brought online as the load increases - however this is not always an option with space restrictions so the design of the heat exchanger is fundamentally important in that respect.

  • @senthilkumar84
    @senthilkumar84 4 роки тому +6

    This is one of the best educational channel for engineers. Your explanation along with graphics makes it easier to understand. It is very difficult to picture something in your mind when you have no idea about how it looks like, that is where your video makes a difference. Very practical. Thank you from a sincere engineer

  • @EngineeringMindset
    @EngineeringMindset  5 років тому +1

    Learn how to *CALCULATE CHILLER SAVINGS* here: ua-cam.com/video/YMwb3-N_Lu8/v-deo.html

  • @engineerforengineers3272
    @engineerforengineers3272 4 роки тому +2

    Sub cooling can be done for both water and air cooled chillers ...for power saving

  • @suhailaakram742
    @suhailaakram742 3 роки тому +2

    What are the pros and cons of increasing the chiller's flow rate? by increasing the chiller flow rate, it'll produce more cooling water.

  • @maboto6969
    @maboto6969 4 роки тому +2

    hello,
    big thanks on all the great videos you post. they are a huge help.
    is there an option that you will do a video or a series of videos about
    humidifiers and how they work ?

  • @daledozerx2920
    @daledozerx2920 5 років тому +13

    i work for Johnson Controls, i love the videos i tell my guys to check out alot of your vids it helps train alot of these younger guys

    • @Dattp51
      @Dattp51 Рік тому

      We have johnsons york chillers, please guide us in order to reduce the ikw/TR of chiller

  • @DecimalZer0
    @DecimalZer0 6 років тому +2

    You do amazing videos, thank you!! The animation in your videos, showing the moving lines representing flow, what program are you using?

  • @yuvarajc8951
    @yuvarajc8951 6 років тому +2

    Super keep doing in Chiller topic pls

  • @mizbahant4430
    @mizbahant4430 2 роки тому

    Thank you for this nice work

  • @actionwoman2477
    @actionwoman2477 2 роки тому

    I love your videos deeply love

  • @adamnelson5056
    @adamnelson5056 4 роки тому

    Have you covered absorption chillers?

  • @marinavillaverde7299
    @marinavillaverde7299 5 років тому

    Excellent video!! Thanks

  • @abedalkhatib76
    @abedalkhatib76 3 роки тому

    What is the difference in energy savings with using VFD on compressor vs van guides?

  • @R0yL33
    @R0yL33 2 роки тому

    how bout spraying water on condenser?

  • @DavidHarsant1
    @DavidHarsant1 6 років тому +1

    is there a video out for setting up danfoss hvac drives especially one that goes into all the settings and software settings? ive seen some but not all of them are that helpful.

    • @EngineeringMindset
      @EngineeringMindset  6 років тому

      Not on this channel, but I will pass your message on to them

    • @danfossdrives
      @danfossdrives 6 років тому +1

      Hi and thanks for reaching out. Unfortunately we don't have one overall video for setting up VLT HVAC Drives. Here is a general video: ua-cam.com/video/kM362qeTTew/v-deo.html and you've probably seen videos such as this one: ua-cam.com/video/JQYk0Pm_NyM/v-deo.html. You can read more about the product on our website: www.danfoss.com/en/products/ac-drives/dds/vlt-hvac-drive-fc-102/. Please don't hesitate to reach out to your local sales office for further assistance: www.danfoss.com/en/contact-us/contacts-list/?filter=type%3Adanfoss-sales-service-center. Kind regards.

  • @abhimat
    @abhimat 6 років тому +1

    What is the difference between free cooling and economiser cooling? Are they just the same...

    • @musaalamleh365
      @musaalamleh365 4 роки тому

      they are the same

    • @slamatarik712
      @slamatarik712 4 роки тому

      An economiser cooling is a free cooling process using a heat exchanger

  • @navinsingh3674
    @navinsingh3674 3 роки тому

    Hi sir its my request plz upload all these videos in Hindi.
    Like all related with chiller.

  • @Samara200M
    @Samara200M 2 роки тому

    How much of the chiller efficient

  • @AH-mj1rd
    @AH-mj1rd 6 років тому +2

    These standard manufacturers of chillers are not efficient. We have a new carrier unit chiller and the power consumption is horrible. We purchased an chiller from a refrigeration company that designed it from scratch, and its consuming half the electricity of the carrier unit. Plus it was about 30%cheaper than the carrier unit

    • @EngineeringMindset
      @EngineeringMindset  6 років тому

      They are efficient but only if sized correctly and controlling properly. Of course having anything custom made is going to be better than a one size fits all.

  • @abhimat
    @abhimat 5 років тому

    Does EC (air-cooled chiller) fans retrofit at condenser improve the efficiency significantly where the normal non-EC fans used have staging feature?

    • @EngineeringMindset
      @EngineeringMindset  5 років тому

      Potentially, because of the fan affinity laws. Check out fan calculation video. If your chiller is logging the fan data then you can calculate it.

  • @joan780
    @joan780 3 роки тому

    Try tun for

  • @InspiringlyPositive12
    @InspiringlyPositive12 2 роки тому

    👍👍👍

  • @zjeepgozweeln
    @zjeepgozweeln 3 роки тому +3

    Cooling tower fans do not consume a lot of power compared to the chiller compressor(s). I don't like a single condenser water set point (i.e. 80F/27C), because it often makes the chillers work harder unnecessarily, killing your COP. I prefer targeting 5F(3C) above the outside air wet bulb temperature with a 55F(13C) low limit. This strategy works in every climate, dry or humid.

  • @ioanberende9651
    @ioanberende9651 6 років тому +5

    Amazing quality and professional explanations,

  • @MalcolmMurray43
    @MalcolmMurray43 2 роки тому +1

    Typo @7:16? Full load set point should be 27C/80.6F

  • @german8438
    @german8438 4 місяці тому

    Very good report.Thi´s help me so much. Many thanks.👍

  • @BRWDJP
    @BRWDJP 6 років тому +2

    Please do a VFD video please . Love your channel keep up the good work

  • @yuvarajc8951
    @yuvarajc8951 6 років тому +1

    It's very useful and pls explain the EXV

  • @بوفارسبونورا-ص7ه
    @بوفارسبونورا-ص7ه 6 років тому +1

    W done

  • @MDSHAHID-KHAN
    @MDSHAHID-KHAN 3 роки тому

    Your video are really amazing. Can you please a video on chemical dosing for Condenser water & chilled water. your work is highly appreciated.

  • @jesusomarplascenciafrias8878
    @jesusomarplascenciafrias8878 4 роки тому

    Please.It explains the loss of efficiency of chillers and other systems due to maintenance factors.

  • @autonable
    @autonable 6 років тому +1

    Thanks for your videos! Do you have any extra information or videos on how to go about utilizing a chiller sequencer? Is this similar to lead/lag, or can I program the chillers to run at specific loads instead of just on/off.
    We have two chillers of different capacities, so each has different efficiencies at different loads.

    • @EngineeringMindset
      @EngineeringMindset  6 років тому +1

      Not currently. Best option is contact a supplier or your BMS specialist

  • @samrios3934
    @samrios3934 Рік тому

    This is stellar 💯

  • @shanemurphy9688
    @shanemurphy9688 2 роки тому

    You 575

  • @glanntellis6678
    @glanntellis6678 5 років тому

    Chilled water reset and condenser water reset will only work if vfd is there in the system right?

    • @EngineeringMindset
      @EngineeringMindset  4 роки тому

      VFD Video is now live! here: ua-cam.com/video/yEPe7RDtkgo/v-deo.html