I am a big proponent of properly matched systems, I have seen too many problems from mismatched systems because customers have tried to save money. When installing a mismatch system, always provide an option for a properly matched system as the recommended course of action, and provide a disclaimer with the mismatched option that there could be comfort issues that you are not responsible for and could have to be corrected at an additional cost.
Can you do a "Ductwork sizing basics" video for residential HVAC systems? Preferably for air handler/heat pumps? Im a fujitsu guy in NE Pennsylvania and can't seam to figure out the correct duct sizing, static, and cfm for ductwork on them compared to our good ole relaible furnace/ac split systems.
the solution to the blower speed/de humidification dilemma is to run 400 cfm per ton but use humidity control and slow down as needed on demand, getting the best of both
What sucks is nowadays you can't swap out a condenser and case coil (gas furnace) unless it meets the AHRI Reference sheet for your manufacturer you install.
What are your thoughts on replacing a ~14 yr old Goodman air handler with a newer Bryant premium variable blower air handler but leaving the Goodman condenser? I have a leak in the evaporative coil but the condenser is in great shape. The air handler is in a hallway closet and is very loud so looking to replace it with a quieter newer version rather than just replacing the coil if possible
I am a big proponent of properly matched systems, I have seen too many problems from mismatched systems because customers have tried to save money. When installing a mismatch system, always provide an option for a properly matched system as the recommended course of action, and provide a disclaimer with the mismatched option that there could be comfort issues that you are not responsible for and could have to be corrected at an additional cost.
I like Parker TXV kit. 4 valves and adapters take care of most jobs. Thank you for the info.
Size matters a lot when you’re dealing with an attic unit. TXV is imho the best all around performance. Good info
Great info! 🙌🏼 cheers brother
How do you calculate the replacement of a piston with a txv? And if a txv is so much better then wouldn't an electrical controlled txv be best?
Glad you still making video you are the OG
WOW 😮..... Just what I need to know Trane quality. Just bought Complete AC and Heating System RunTru By Trane. The a coil was Damaged and Returned
Can you do a "Ductwork sizing basics" video for residential HVAC systems? Preferably for air handler/heat pumps? Im a fujitsu guy in NE Pennsylvania and can't seam to figure out the correct duct sizing, static, and cfm for ductwork on them compared to our good ole relaible furnace/ac split systems.
the solution to the blower speed/de humidification dilemma is to run 400 cfm per ton but use humidity control and slow down as needed on demand, getting the best of both
What sucks is nowadays you can't swap out a condenser and case coil (gas furnace) unless it meets the AHRI Reference sheet for your manufacturer you install.
This could be relevant to me, as I try to deal with the undersized system we were sold.
What are your thoughts on replacing a ~14 yr old Goodman air handler with a newer Bryant premium variable blower air handler but leaving the Goodman condenser? I have a leak in the evaporative coil but the condenser is in great shape. The air handler is in a hallway closet and is very loud so looking to replace it with a quieter newer version rather than just replacing the coil if possible
I always have a matched pair
I’m glad around here 99% of stuff is furnaces in basements. Attic work sucks.
I charge extra for attics.
Good to know information.