Hello, Yes, the wet bulb at the return duct and dry bulb by the condenser ambient temp, I took them separate and then on min 4:05 I input them manually. Im sorry it was not clear. Now I have two extras testo 605i bluetooth thermometers which it makes it way easier. Thank you so much for your comments. I have 3 more videos where I use the whole 6 probes.
Hello Clark. Yes. Testo designed them specifically for that. One for the suction and one for the liquid line. Every probe has an identity , say 318. When you do the set up on your phone you select fsay 318 for the suction line and place a blue label on that. And then you allocated the liquid line with its ID and put a red sticker as well. After that you are to place the probe with the blue label on the suction line, and red to the liquid line. Testo now a day have an array of this probes to measure anything you think of. ie; Temp. press. humidity, rfm, velocity , wet and dry bulb, static so an and o forth.
Great video. I'm considering purchasing these devices in a kit to evaluate the status of my AC units. Very useful information
Great video Fella! Nice and clear info...
Thanks for the info!
MY pleasure ! Please dont forget to like and subscribe!!!
Where the dry and wet bulb values came from?did you measured separetly and manual imput the values or the sofware aproximates it?
Hello, Yes, the wet bulb at the return duct and dry bulb by the condenser ambient temp, I took them separate and then on min 4:05 I input them manually. Im sorry it was not clear. Now I have two extras testo 605i bluetooth thermometers which it makes it way easier. Thank you so much for your comments. I have 3 more videos where I use the whole 6 probes.
@@alexthehandyman3494 Thanks for the answer.
Can either be used on the suction and liquid line?
Hello Clark. Yes. Testo designed them specifically for that. One for the suction and one for the liquid line. Every probe has an identity , say 318. When you do the set up on your phone you select fsay 318 for the suction line and place a blue label on that. And then you allocated the liquid line with its ID and put a red sticker as well. After that you are to place the probe with the blue label on the suction line, and red to the liquid line. Testo now a day have an array of this probes to measure
anything you think of. ie; Temp. press. humidity, rfm, velocity , wet and dry bulb, static so an and o forth.
@alexthehandyman3494 thanks for the speedy reply.
IOS app, how can I choose refrigerant? I don't see any option to choose the refrigerant.
What apps you use?
"Smart Probes" is Testo apps
Was 410 or r22
R22 in the beginning and R410A at the end