The diagram is not followed, base on the diagram the "Y" Line 2 from the main contactor is going on the "B" which is Line 3 of the Delta contactor where the actual wiring is R-R, Y-Y, B-B. In the diagram is R-R, Y-B, B-Y.. The actual wiring has no Delta connection, correct me if I'm wrong
Aapke video ki wiring, diagram ki wiring se match nhi kr rhi h. Main cotactor se delta contactor ke liye di gayi taping me phase sequence change hona chahiye. For example: R Y B to Y B R
Mere pas 2hp 3phase ki motor lgi hai machine pr kpre dhone wali woh abhi wapda pr chlti hai automatic system lga hai reverse forward k lyee ab mujhe. Yeh malom krna simple wapda input vfd me lgado or motor reverse forward k lyee vfd to trip nhi krwga naa ???
Thank you very much U don't understand the language but demonstration is good. Next video 📷 suggest you edit it with English words while explaining it in Hindu
1 issue ha is wiring me. pls check it again...Look at delta connection, U1-U1 me lg raha ha connection, jbkeh u1-w1, u2-v2 and v1-w2 hony chahey thay, explain pls
Bhai RYB phase jab current pass hoga tb tho direct Delta me chala jaiyega na Q ki line diya hua hai Mian Contactor se phle kaise hoga tora pls bata dijiye??
Sir maine gulf me 2 moter wala painal dekha hai jo pahle sab ek sath chalte hain fir step by step chalte hain , maine jahan bhi repair kia single kar diya 2 samajh me nahi aaya
Sir mujhe aapki ye video achi lagi but isme aapne ye bhi bataya hota ki kaise pahale star conection chalta hai uske bad delta ka kaise Kam karta hai ye nahin bataya
The wiring and the drawing do not match : On the drawing two wires are swapped between main contactor and delta contactor but on the actual wiring nothing is swapped.
Sir,aapne ke drawing me aor practical me thoda farak hai kionke,mcb aur main contactor ke beach se delta ke upar ke side jo wira jare aor aap ke practical difrant hai sahi kaonsa hai batana
Star Delta Starter Power Connection with Wiring diagram by Ever_Green_Electrical
Kindly like Comment and Share video
Thanks
Good
Wiring diagram to sahi hai but connection sahi nhi hai
Kya Main contactor wali supply U2, V2, W2 ma da sakta hy
Bhai super bhaut accha video tha
Pura wiring samajne aagahe
Bahut shukriya bhai thank you
For this video
Thanks
Samjhane ka tariqa zabardast hai, mashallah
Thanks
Nice
Simple explained 👍
(Love from punjab india)
Very nice sir ji apka video bahut accha laga
Bahot hi asaan shabdon me samjhaya hai.
Thank you sir you teach this very simple method,❤️
Thanks
How to get your phone number or what app number
Love from Indian Electrical community.
Thanks
The diagram is not followed, base on the diagram the "Y" Line 2 from the main contactor is going on the "B" which is Line 3 of the Delta contactor where the actual wiring is R-R, Y-Y, B-B. In the diagram is R-R, Y-B, B-Y.. The actual wiring has no Delta connection, correct me if I'm wrong
Yes i agree with you i am confused also
Ur correct 👍
Right
He made a mistake in the schematics but the actual wiring job is correct, though it ought to go with a timer.
Bhai power wiring bilkul sahi aap motor ke terminal par dhyan se dekho, delta connection ban rha hai
Aapke video ki wiring, diagram ki wiring se match nhi kr rhi h. Main cotactor se delta contactor ke liye di gayi taping me phase sequence change hona chahiye.
For example: R Y B to Y B R
Yup
ua-cam.com/video/HWB-igFyamI/v-deo.html
I don't understand your language but I just get it what you mean, I think you are right Bro.
You said it
You are right brother.
وعليكم السلام
Thanks sir ji nice Video
Thanks
Sir ji please Whatsapp Number par msg karo
Mujhe aap se bahut urgent baat karni hain
Star delta ke baare mein
00966530948970
Very good explanation
Grate explaination salute, valueable video, very informative .
sir thank you so much. You made this topic so easy. thanks
Thanks
Bina relay nahin lagana hai star delta operate karna bataiye mujhe bahut jaruri hai❤❤
Wonderful 😌
Really very good
Please make more videos related to electrical machines
thank you for teach very nice method
Very nice job keep it up
Good luck 🍀
Thank you ❤️ good information
Great!!!
and your every information are learnable
Thanks
Zabardast sir 👍
super information
Thanks
Very nice vedio sir
Thanks
Excellent work👍
Thanks
Thanks for the video sir very important
Excellent video
Thanks
Very very thanks sir
Excellent explanation good
Thnk u sir ❤️
Thanks bhaii jaaaaan
Good job
Excellent description
Good informition this video
🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔🤔
Good work
Thanks every green
Thanks
Thanks sir God bless you
Please make video on reverse forward starter...
Very great
Very nice view
Very good information
love you sir g
Mere pas 2hp 3phase ki motor lgi hai machine pr kpre dhone wali woh abhi wapda pr chlti hai automatic system lga hai reverse forward k lyee ab mujhe. Yeh malom krna simple wapda input vfd me lgado or motor reverse forward k lyee vfd to trip nhi krwga naa ???
Achi video ha
great job. .keep going
thanks
Thanks
Goodest bhai
Thanks uh sir
Very good
Nice video
Thanks
Thank you very much
U don't understand the language but demonstration is good.
Next video 📷 suggest you edit it with English words while explaining it in Hindu
आपकी ड्राइंग में एक कमी लग रही है की आपने y फेस y से उठाकर b फेस में लगाया है
Nice 👍
his invention is such an invention that will be a milestone for the Star delta contactor. UA-cam : (Amazing Contactors)
1 issue ha is wiring me. pls check it again...Look at delta connection, U1-U1 me lg raha ha connection, jbkeh u1-w1, u2-v2 and v1-w2 hony chahey thay, explain pls
Thanks
Bahi g jo diagram me tar lagai star contactor waise phr practical me b lagatey q confusion pehlaa rahy
सर कृपया दिखाए आटोमेटिक पैनल की बायरिग डायग्राम जनरेटर ओर पॉवर स्पल्लाई
Sir 3phash moter ke liye use hota hai ya 1sigal phase ke liye use hota hai
beautiful
Super
As per drawing and connection there r two cable showing in motor..am I right?
I need the equipments to do a project work.
So please help me.
How may I help you..
Sir olr delta me lagega na
Nice
Sir kya delta me bhi OLR lagaya ja sakta hai
Bhai RYB phase jab current pass hoga tb tho direct Delta me chala jaiyega na Q ki line diya hua hai Mian Contactor se phle kaise hoga tora pls bata dijiye??
Sir maine gulf me 2 moter wala painal dekha hai jo pahle sab ek sath chalte hain fir step by step chalte hain , maine jahan bhi repair kia single kar diya 2 samajh me nahi aaya
Mery channel pay video hy dekh lo
Sir mujhe aapki ye video achi lagi but isme aapne ye bhi bataya hota ki kaise pahale star conection chalta hai uske bad delta ka kaise Kam karta hai ye nahin bataya
Good
Bhaia mujhe thora doubt ho ra ha, star ka niche ka jo 3 phase thora change hoga as per circuit diagram hisab se, like red to blue
bht acha kia hai lkn cobtactir or timer energize k lia nhi btaya,jo main point hai
good
Thx
Super explain bro🥰🥰🥰
Sir g time relay kis ka oper lagany Hain g
❤❤❤❤
Is it On-Timer or Off-Timer?
Please give urgent reply
Please make control connection. I need control connection...
I will upload soon...
Plz make control video I need control video of star delta connection..
The wiring and the drawing do not match : On the drawing two wires are swapped between main contactor and delta contactor but on the actual wiring nothing is swapped.
👍👍👍
Please mention the breaker and contactor rating for 10 hp or 15hp motor.
16 A or above ratings
why OLR Connected Main contactor only? How to know full load amps
Brother timer k circuit ka btaya e ni or interlocking ka b ni
Aapne main contactor ka yellow phase delta contactor k blue phase m diya huaa h or yellow phase blue phase m diya h
Really good, but please do in English if you can,
Ok thanks for your feedback
Isn't this English??
Sir,aapne ke drawing me aor practical me thoda farak hai kionke,mcb aur main contactor ke beach se delta ke upar ke side jo wira jare aor aap ke practical difrant hai sahi kaonsa hai batana
Bhai es me timer or over load really k connection to btay nai ap nay
Sar aap Dhyan den aapane a diagram mein Main Kaisa connection kiya hai aur practical Mein Kaise connection kar rahe ho
Mazbot video mata easy tani Jadid control video, ana reed talim hada tani video
I will upload soon this video...
Sir Esme oto swich kese lgaye
Sir single fuse starter ki wiring ka video banao
Ok
I want video full control wireing want
This will not be working properly. Need to change position of phase in Delta contact
Diagram wiring connection wiring se match nae kar rahi he,
Jab aap star Or delta contactor ko interconnect kar rahe ho waha masla he.... Gor farmaiye
Aap diagram mein alag wiring.draw ki hai..aur practical mein alag ki hai sir confusion hai..pls clarify it
System with time k sath runing krna chahiye the ye power ka kaam hai ese hi ni buaht dangerous hota hai complete kre is video ko
Sir control wiring ka video banao
Ok
Hii sir i want to talk with you
Sir aapne NO NC PUSH BUTTON AUR TIMER KA CONNECTION NAHI KIYA HAI YE SAHI SE KAAM NAHI KAREGA PLS CLEAR KIJIYE