How to use AC 80-260V 100A PZEM-061 Active Power Meter

Поділитися
Вставка
  • Опубліковано 24 лип 2024
  • This video explains how to prepare and use one of the best AC Power meter that is Available in the market. The PZEM-061.
    **** Purchase this meter from ***
    Amazon Canada: amzn.to/3kT2AJi
    Amazon USA: amzn.to/3i3ULyA
    All other Amazon: amzn.to/3yiBsqM
    AliExpress: s.click.aliexpress.com/e/_AbSX3e
    Banggood: www.banggood.com/custlink/3mm...
    Click on a different section of the video:
    00:00 Introduction
    04:54 Wiring Explained
    07:05 Demonstration of power measurement
    13:17 setting and Power Alarm
    Download manual and other resources: robojax.com/L/?id=254
    Related videos:
    P06S-100 AC power meter: • Test Review of PUUCAI ...
    Wireless DC Power/Current Meter video review:
    • Juntek VAT4300 Wireles...
    Tutorial by Ahmad Shamshiri form Canada
    ****************************
    Arduino Step by Step Course (over 150 lectures) Starts here • Lesson 00 What is Ardu...
    ****************************
    If you found this tutorial helpful, please support me so I can continue creating contents like this. Here is PayPal link paypal.me/robojaxTV
    Follow me on Facebook robojaxTV
    Follow me on Twitter: / robojaxtv
    Follow me on Instagram: / robojax
    Tutorial by Robojax.com
    Get other projects code and learn Arduino
    robojax.com/learn/arduino
    *** AFFILIATE PROGRAM ***
    We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites.
    #robojax #robojax_meter
  • Наука та технологія

КОМЕНТАРІ • 133

  • @leighhardy9926
    @leighhardy9926 4 роки тому

    I just received my meter. Thanks for the great overview of the product.
    Your explanation was easy to understand.
    Thanks.

    • @robojax
      @robojax  4 роки тому

      You are welcome!

  • @thomaslevesque8996
    @thomaslevesque8996 4 роки тому

    thank you for your excellent instructions; the directions that came with the unit did not explain how to power the unit and you did so very nicely

  • @HasteFrankie
    @HasteFrankie 2 роки тому

    great video! any suggestions for a CT for more accurate measurements for smaller ampere applications? maybe under 20a?

  • @truesimplicity
    @truesimplicity Рік тому +1

    Excellent, clear and concise 👍🏻

  • @adamelkoumy5141
    @adamelkoumy5141 5 років тому +4

    Another great video by Jax :)

  • @davejohn255
    @davejohn255 2 роки тому

    Thanks , That is the way I thought it hooked up but it is good to be sure. I am using this to monitor a 12500 W Generator to tell how much I am using (In Watts). Mounting on the Service Panel of my house. It looks like since I have 2 legs each with 120V , I will need 2 of these, 1 for each leg. Totaling 240V. Than I would add the 2 Wattage readouts together to get the total draw/watts . It doesn't even look like both wires would even fit through the clamp.

    • @juansifuentes3917
      @juansifuentes3917 2 роки тому

      I just received 2 and will use them for the same purpose. I have a 13000 gen. Maybe you can answer me a question. I’ve seen different CT connections. Does the red wire from the CT go on the top connection or the black one?

  • @tirunanmuddukrishna
    @tirunanmuddukrishna 4 роки тому +1

    Excellent details your videos thank you very much sir.. I am india

    • @robojax
      @robojax  4 роки тому

      You are welcome. Ahmad from Canada

  • @echeverriaemilio
    @echeverriaemilio 22 дні тому

    Thank you for the excellent explanation ❤

  • @letsmakeinventions
    @letsmakeinventions 3 роки тому +1

    Thank you so much cor the video. You Rocks

  • @phongnguyen1434
    @phongnguyen1434 5 років тому +1

    Great videos, thanks so much!!!

    • @robojax
      @robojax  5 років тому

      You are welcome.

  • @okuri
    @okuri 4 роки тому

    Great explanation, thank you very much!

    • @robojax
      @robojax  4 роки тому

      You are welcome!

  • @minamatta6135
    @minamatta6135 2 роки тому +1

    sir, I didn't get the capacitor, my question is want it to measure the power consumed by an ac unit which have two motors and two big capacitors will it measure the power consumed by the unit, right or not
    please help and thank you for your great video

  • @astroid9087
    @astroid9087 2 роки тому +1

    Great demo 👍 🙏

  • @loamy
    @loamy 2 роки тому

    One of my favorite

  • @psudrat
    @psudrat 7 місяців тому +1

    Thank you very much for sharing

    • @robojax
      @robojax  7 місяців тому

      My pleasure

  • @entrend
    @entrend 5 років тому

    What is the maximum digit can the energy meter display? It shows reading in Wh, does it change to 1KWh after reaching 1,000Wh?
    If not, for instance, the max digit that can be displayed is 4, It can only then show 9999Wh, If so, does it reset to zero after reaching max???? Hope you can clarify. Thanks..

    • @robojax
      @robojax  5 років тому

      Hi, it will go to 9999kWh. The link to Amazon or eBay will shows the specs. Here is one of them www.amazon.ca/dp/B00YY1KOHA

  • @asadulhuq
    @asadulhuq 4 роки тому +1

    Excellent presentation.

  • @jimanddiana4103
    @jimanddiana4103 4 роки тому

    Thanks, very informative and complete. I would love to see you show this meter with split phase 240 volt. Like that of an electric dryer or range. Will it show 120V or 240V?

    • @robojax
      @robojax  4 роки тому

      you are welcome. it just measure the phase that is passing through the sensor. So you won't get the current value for more than one phase. Voltage doesn't matter.

  • @Captain_Spaulding_01
    @Captain_Spaulding_01 4 роки тому

    Nice job Sir. Thank you!

    • @robojax
      @robojax  4 роки тому

      You are welcome.

  • @ahmedsoffy581
    @ahmedsoffy581 3 роки тому +1

    perfect product

    • @robojax
      @robojax  3 роки тому +1

      what about tutorial?

  • @joshua43214
    @joshua43214 3 роки тому +1

    Thank you.

  • @timrosandick491
    @timrosandick491 2 місяці тому

    Good job. I want to use it to measure Kw over a period of time. Will it work for that purpose? If so, am I able to clear the "counter" and reset it for a measurement over a new period of time?

    • @robojax
      @robojax  2 місяці тому

      Yes you can and I have shown how to reset it.

  • @SodiumInteresting
    @SodiumInteresting 3 роки тому +1

    hi robojax, I am attempting to get reading from a 4 plug adaptor so as to measure the power consumption of anything I plug into it. I am in UK and the lead I want to test has 3 wires earth, neutral and live. so far I have cut the live brown wire and soldered on bullet connectors and heat shrinked tubes as you have on your positive wire so I can feed it through the current transformer coil. am I right in thinking I can now power the module if I attach positive to live and negative to neutral. I understand you explain what you've done well in the video but will this work how I'm doing it and is the capacitor a requirement for this use?
    I will appreciate if you can help me with doing this safely thankyou,
    Tom

    • @robojax
      @robojax  3 роки тому

      Hi, I can't explain it by writing better than video. So watch the video that. The capacitor it seems you've skipped the video. I used the capacitor to proof that the module actually is showing the Power Factor pf. You don't need any capacitor. This video has the word on the image "tested" and many produces don't do the pf. so It passed the test.

    • @SodiumInteresting
      @SodiumInteresting 3 роки тому

      @@robojaxthat is what I thought, I just wanted to check. your video is definitely the best could find on this module
      I assume everything else im doing is right. your power cable has only 2 wires
      I just ignore the earth wire and it is the same?
      lastly I bought the jst connectors and and wire tap connectors and I am still waiting for them to arrive... is a wire tap connector a good way for diverting modules power from the main cable?
      thankyou for your quick response and I apologise as I'm sure these are obvious questions

    • @robojax
      @robojax  3 роки тому +1

      for current measurement yes. you just need ONE wire to pass through this. Earth wire is for appliances for safety purpose.

    • @SodiumInteresting
      @SodiumInteresting 3 роки тому

      @@robojax thankyou

  • @techworld7988
    @techworld7988 8 місяців тому

    Hi sir,
    I am using dc meter to check how many volts and amps are coming from solar. The meter is working fine in daytime but in night it's showing solar charging symbol in my pwm charge controller(like reverse charging)
    Please help me on this

  • @mycinemax2653
    @mycinemax2653 4 роки тому

    Hi, in my understanding this device wont heatup if we use example 22000W (the max of this device), because its use the CT for calculate the usage right? and is this device can store the data if the power is cutoff? i want to use this to calculate kwh of my 3 3d printer each month to pay to my parent.

    • @robojax
      @robojax  4 роки тому

      it will not heat up to 100A. and yes it should keep the power but have not tested it.

  • @darryledunn4065
    @darryledunn4065 5 років тому

    if I was to use this meter with an SRC power controller ,would I pick up my power before or after the SRC controller

    • @robojax
      @robojax  5 років тому

      You should pass the power wire through this and then to any load you got. SCR is part of the load for this device.

  • @Ravisingh-ne4zy
    @Ravisingh-ne4zy 2 роки тому

    Thanks alot. But my meter showing wrong wattage and kwh running continue

  • @christophergutierrez2051
    @christophergutierrez2051 2 роки тому

    Will this meter display negative power readings , let’s say correct voltage sequence with the CT in reversed polarity

    • @robojax
      @robojax  2 роки тому

      No I will not work. I believe

  • @zainmeer3076
    @zainmeer3076 4 роки тому

    Hi jax .... i would like to know about the resistor smd R15 value which is in side just behind the inputs.

    • @robojax
      @robojax  4 роки тому

      I would have to check the device at home. I replied yesterday but don't know what happened, youtube did not save it.

    • @zainmeer3076
      @zainmeer3076 4 роки тому

      @@robojaxthnx for rply .... Please check it and tell me about the value of smd R15 of Pzem 061 version 5.0

  • @philmcandrews
    @philmcandrews 3 роки тому

    Is it OK to extend the coil connector wires on this setup?

    • @robojax
      @robojax  3 роки тому

      try it. use shielded wire so noise does not get into it.

  • @tomgreysk
    @tomgreysk 4 роки тому

    When I set the required voltage, the display will flash. So I want to ask if he has any signal or control output. Somewhere on the board.

    • @robojax
      @robojax  4 роки тому

      No output. It is the transformer that get the magnetic field and displys on screen.

  • @electricalinfohub1543
    @electricalinfohub1543 5 років тому

    Excellent

  • @roncarter2188
    @roncarter2188 2 роки тому

    So I bought this meter to use on my old variac. Do I have to use the magnetic ring to use this? Or can just use the ac voltage taps on the meter? Thanks for any help.

    • @robojax
      @robojax  2 роки тому

      May be you did not watch fully or you missed it. Of course you need it. Please watch again.

    • @roncarter2188
      @roncarter2188 2 роки тому

      @@robojax I watched the whole video, but I'm not using this meter hooked up in the same way that you demonstrated. The load is coming from my tube amplifier that I'm going to have plugged into the variac.

    • @robojax
      @robojax  2 роки тому

      To read the voltage we to calculate the power. We need a o connect the two wires. To read the current we need the current sensor (ring)

  • @angelohizon9497
    @angelohizon9497 3 роки тому

    Can i use this for 24/7 inside our breaker that is located outside of the house?

    • @robojax
      @robojax  3 роки тому

      tough question. contact manufacturer.

  • @mattmustin1860
    @mattmustin1860 4 роки тому

    I have same meter. Will it record more than 10,000 WAtt hours? My application requires more.

    • @robojax
      @robojax  4 роки тому

      you can go up to 4 digits. 9999Wh

  • @dontblameme6328
    @dontblameme6328 5 років тому

    Can you explain why you included the capacitor in your setup?

    • @robojax
      @robojax  5 років тому

      The whole video is about the capacitor. I just watched the video to see if I had forgotten explaining it. For sure have explained it. Watch the video and do not escape. I have spent more than a day making this video so you do not escape.

    • @erickaustin7162
      @erickaustin7162 4 роки тому +1

      escape = skip

  • @gerardgapin7792
    @gerardgapin7792 2 роки тому

    Vidéo en anglais mais traduction française. Bien expliqué mais les branchements sont peu montrés alors je rame...... merci

  • @dj_sorra8605
    @dj_sorra8605 Рік тому

    I need one for DC

  • @tavatchaiboonsook7249
    @tavatchaiboonsook7249 4 роки тому

    For this, if the display shows up at 9999kWh, will it be counted again? Or hold like that Do you have to press to reset yourself?

    • @robojax
      @robojax  4 роки тому

      that is 100MWh. Never tested but logic says it should reset and start from zero because new data has always more value than older data.

    • @tavatchaiboonsook7249
      @tavatchaiboonsook7249 4 роки тому

      Thank you

    • @robojax
      @robojax  4 роки тому

      you are welcome.

  • @MimariTasarm3DCepheCizimi
    @MimariTasarm3DCepheCizimi 4 роки тому

    Tnx

    • @robojax
      @robojax  4 роки тому

      You are welcome.

  • @user-rc8pd6ve5n
    @user-rc8pd6ve5n 4 роки тому

    thank yoooooooooooooooo

    • @robojax
      @robojax  4 роки тому

      you are welcome.

  • @fazrulirfan7856
    @fazrulirfan7856 3 роки тому

    Sir can this meter to measure from 12 vac?

    • @robojax
      @robojax  3 роки тому

      please read the title of the video if you have not watched it.

  • @salvatorehayes2753
    @salvatorehayes2753 4 роки тому

    So It Will Not Read Voltages Below 80 And Frequencies Below 45Hz?

    • @robojax
      @robojax  4 роки тому

      I have not tested it. We don't have any country to have home AC power below 110 V.

    • @salvatorehayes2753
      @salvatorehayes2753 4 роки тому +1

      @@robojax Ok Yea I Don't Think It Will. My Use For This Was To Measure The Live Output Of An Bass Amplifer. They Output AC Voltages From 0-80v For My Application, And 0-60Amps AC With Frequencies Ranging From 20-40Hz. It Would Be So Awsome To See Live Wattage Of My Amplifiers Durring Test Tones And Maybe During Music With Long Bass Notes.

  • @binoddas3048
    @binoddas3048 3 роки тому

    Sir I want this miter so I will how can apply .now I am saudia dammam

    • @robojax
      @robojax  3 роки тому

      Hello, you can use it anywhere in the world. it works from 80V to 260V. So there should not be any problem.

  • @DTomlinsonpiano
    @DTomlinsonpiano 11 місяців тому

    How do you TURN OFF the alarm if once set??

    • @robojax
      @robojax  11 місяців тому

      I don’t remember anything about this product but if I had shown how to turn it on or set it then you should turn it off by unsettling it.

  • @juliusvalentinas
    @juliusvalentinas 4 роки тому

    Is there calibration?

    • @robojax
      @robojax  4 роки тому

      No as far as I know. It is already set.

  • @mikakimi2558
    @mikakimi2558 4 роки тому

    what is the value of the capacitor?

    • @robojax
      @robojax  4 роки тому

      which capacitor? The round thing is CT (Current Transformer)

  • @X-electronics
    @X-electronics Рік тому

    Does it use with Dc current ?

    • @robojax
      @robojax  Рік тому

      It is AC only

    • @robojax
      @robojax  Рік тому

      Use this ua-cam.com/video/tgneN2hzRe0/v-deo.html or this 10A ua-cam.com/video/2FzceyhG37M/v-deo.html

  • @Anangfahruddin.
    @Anangfahruddin. 5 років тому

    If i use on inverter this meter is very hot.why?

    • @robojax
      @robojax  5 років тому

      It should not get very hot. "very" is not clear. If you are in area with 30°C room temperature, then if it gets 50°C or 60°C it should be normal.

  • @rcclubturkiye401
    @rcclubturkiye401 5 років тому

    15 m 37sec. Voltage 117v current 1.95 Amperes
    But power is 90.60 watt. why? (İn your video)
    117 Volt x 1.96 Amp. = 228 w
    15 min. 46 sec. 113 volt x 11,29 Amp = 1275 watt ...1279 watt may be.
    But ,why first power on ( level 1) 90,60 watt.
    I have same problem :-(

    • @robojax
      @robojax  5 років тому +1

      the value is from the last day. It saves the values. If you want to use it fresh, reset it. I have shown how to reset it.

    • @rcclubturkiye401
      @rcclubturkiye401 5 років тому

      @@robojax thank you

    • @rcclubturkiye401
      @rcclubturkiye401 5 років тому

      @@robojax but, I did not mean wh value. I mean instantaneous power. Note that when the heat gun is operated at the first level, the power (lower left) does not show the watts multiplied by volts and amps. but at full power at level 2 it shows real value. I don't mean the energy part at the bottom right. Please pay attention to the minutes and seconds that I mentioned in your video. because I am having the same problem with the hair dryer.

    • @robojax
      @robojax  5 років тому

      please type the time like 2:45 so I can click and watch it.

    • @rcclubturkiye401
      @rcclubturkiye401 5 років тому

      @@robojax 15:32 heater level 1, power value is wrog. ( w = v x ı )
      117 Volt x 1,96 Amp. = 229 watt.
      But this product showing 90 watt
      İt is wrong.I do not know why.
      why it shows. do you know why?
      15:40 heater level max. Power value is true.

  • @MicrofotovoltaicoOneWay
    @MicrofotovoltaicoOneWay 4 роки тому

    Minimum watt reading?

  • @edwinnagrampa8820
    @edwinnagrampa8820 5 років тому

    How much??

    • @robojax
      @robojax  5 років тому

      I have link to the store where you can purchase it. the link is in the description snag.gy/EG4O2l.jpg

  • @TheWilferch
    @TheWilferch Рік тому

    Why do you (multiple times), point to package label as model 061 but both times say verbally "016" ???.....I wouldn't be so picky but the backside label you show identifies 2 discrete models....one being 061 and the other 016...so you need to be mindful of this error. Also the large print on your vid at timeline 0:41 also says "016" but I think it's backwards here too. At timeline 1:23 you also point to the package label ( 061) and "say" 016......same at timeline 2:03, reversed numbers again. Otherwise....a very excellent review and report.

    • @robojax
      @robojax  Рік тому

      Yes. I have made so many mistakes. this video has take two or three days to make (I forgot how long) and when I get tired, I try to fish it. If product is shown, then that is valid. Sorry.

    • @TheWilferch
      @TheWilferch Рік тому

      No need to be sorry....my point was simply that in this case, there are indeed 016 models and 061 models, so to be clear for others viewing this. If that wasn't the case, and if it was only a slip-up, I wouldn't have brought it up.....nice job on the remaining details !!....cheers.

    • @DTomlinsonpiano
      @DTomlinsonpiano 11 місяців тому

      There could be a little dyslexia kicking in which is common, a lot of people have it, and it's no big deal.

    • @TheWilferch
      @TheWilferch 11 місяців тому

      @@DTomlinsonpiano ....as I said a few times already...no big deal in general.....but in this case there ARE 2 models....an 016 and 061, so it matters more in this case to somehow get it right.

    • @DTomlinsonpiano
      @DTomlinsonpiano 11 місяців тому

      Yup that makes sense about the 2 models.

  • @binoddas3048
    @binoddas3048 3 роки тому

    saudia Arabia have

  • @bhartiya_sanatan
    @bhartiya_sanatan 5 років тому +1

    Its a pzem 061 , not 016
    Every time you say 016

    • @robojax
      @robojax  5 років тому +1

      You are right. I am sorry can't fix it now. But the text is correct.

    • @bhartiya_sanatan
      @bhartiya_sanatan 5 років тому

      @@robojax ok, dont mind but video is useful and awesome.

    • @robojax
      @robojax  5 років тому

      Thank you.

  • @mosibplang3096
    @mosibplang3096 3 роки тому

    S W R meter

    • @robojax
      @robojax  3 роки тому

      what about it? this is not statement no a questions.

  • @elinesiopanelamedeiro9950
    @elinesiopanelamedeiro9950 2 роки тому

    Produzir

    • @robojax
      @robojax  2 роки тому

      produzir o quê?

  • @homedefenselawrence
    @homedefenselawrence 4 роки тому

    Hi there, The Robojax... I am not really good at electricity but I understand some basics of it. I just ordered one and it has been delivered to my house today. I have the very same model Peacefair PZEM-022 100A. My plan is to use it after my Circuit breaker which is 60A 220V here in the Philippines - so as to see all the readings of the entire house. Do you think it is applicable and can this meter sustain it if I connect it after the circuit breaker as a source of electricity in my house and having this device measuring the current, etc?
    Please give me feedback HWcave for I am expecting answer and thank you very much in advance. :)

    • @robojax
      @robojax  4 роки тому +1

      Yes it will work as this can measure up to 100A. the location either after the breaker or before will not affect the reading. Before breaker will show you the power is ON and that is it.

  • @asadulhuq
    @asadulhuq 4 роки тому

    A good presentation.