Freightliner century Coronado Columbia fixing my bunk blower motor not working .

Поділитися
Вставка
  • Опубліковано 4 лис 2024

КОМЕНТАРІ • 20

  • @weasel884
    @weasel884 2 роки тому +1

    This video is extremely informational very well done

  • @ewright7739
    @ewright7739 2 роки тому +1

    Thanks your video saved me. HVAC breaker fuse was burnt out.

  • @1notsop
    @1notsop 9 місяців тому

    Thanks a lot bro great info I took the fuse out and put it back in and it started working 😊

  • @TruckerMike089
    @TruckerMike089 Рік тому

    Hey thank you so much for this video. I'm having similar issues but I don't believe it's my fuse. The fan doesn't come on at all so either the motor is bad or I don't have enough pressure in the system. I would have never known about that fuse box right behind the seat. Good running out there for you partner

  • @hamburgerhoover208
    @hamburgerhoover208 4 роки тому +3

    Thanks bro I’m on it tomorrow 👍

  • @Davefromwisconsin
    @Davefromwisconsin 8 місяців тому

    I’ve had three different freightliners in the last 18 years where the bunk blower stopped working. Every time it was the PDM, which is the fuse box in the b-pillar. They had water damage from rain water leaking into the cab. If someone knows where to seal it so it won’t leak that would be appreciated but now after replacing the last one I put it in a ziplock bag and installed the screws from the inside of the bag and so far it’s been two years trouble free.

    • @yosthamsandoval2034
      @yosthamsandoval2034 5 місяців тому

      Would you have power going to the blower before changing the PDM? Trying to figure my blower problem out

  • @mitchellestepp9947
    @mitchellestepp9947 4 роки тому +2

    Very helpful. Thank you

  • @wsg12097
    @wsg12097 3 роки тому +1

    Thanks very helpful

  • @Omarfure
    @Omarfure 3 роки тому

    thank you so much great tips

  • @aem4279
    @aem4279 2 місяці тому

    Is the same for the front

  • @wsg12097
    @wsg12097 4 роки тому +1

    Thanks man👏👏👏

  • @moebenjeddou782
    @moebenjeddou782 3 роки тому +3

    Next time lower your seat all the way down and u will be able to open the fuse box door without unscrewing

  • @virgiliofabian
    @virgiliofabian 2 роки тому

    Thank you 😊

  • @sariamohammed1852
    @sariamohammed1852 3 роки тому

    Thank u bro.

  • @MrPollocan
    @MrPollocan 4 роки тому

    What was your problem ? Because mine blows for a little and then stops.

    • @moemoe-qs6bi
      @moemoe-qs6bi  4 роки тому +1

      It cold bee seized blower it mit bee getting hot !!!! You cold switch the front blower and install in bunk if it runs fine you mit need a new blower also clean the filter mit help...

  • @r2rmusic762
    @r2rmusic762 3 роки тому

    I dont have power to muy ac compresor have u had that issue

    • @moemoe-qs6bi
      @moemoe-qs6bi  3 роки тому +2

      If the system doesn't have proper pressure you could lose power to ac compressor