How to repair Zoje ZJ9513-G/02 Sewing Machine E09 Error | Zoje सिलाई मशीन की E09 ठीक करने का तरीका
Вставка
- Опубліковано 16 гру 2022
- Zoje direct drive zj9513-g/02 sewing machine controller repair. Machine run one two rounds and give error e09. some time it's run 1-2 hour and then show error.
Zoje सेलाई मशीन थोड़ा चलके बंद हो जाता है और error e09 दिखाया हे। कभी कभी 1-2 घंटा तक चलने के बाद error दिखाया हे।
Visit our website for pcb repair and buy pcb parts.
Our website:- www.techrepairwala.com/
Good information sir... TQ
Sir mere pas Shera ka machine he usme sevar moter he uski speed kam ho gayi hai or abhi usme error 9 batati hai kaya problem hogi
Very nice sir ❤🎉
Great man
جزاكَ اللّٰه خيرً
Good 👍
Aaisa hi mahine hai par moter nahi chal Raha hai app service dete ho keya
Nice video
Sir video bana do on circuit all components voltage check karna
Aayega video
Sir asp ke pass 74hc00D ic mil jaigi sir 100 ps bhej dena sir
Good job
Mobile number nahi diya
Thanks
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤
Hi thank you for your efforts.i'm asking about (supu f3) control box, no error but it doesn't run
Check padal connection and output voltage of padal sensor
Plis riplay❤❤❤❤❤🎉
Video banaye
Sir mai aap ko etana jada comment karte hai aap reply kyo nahi dete hai
I will try to reply
zjl9513-G/02 how to do error01please sir
Merhaba dostum. E20 arıza kodu ne anlama geliyor? Yardımcı olursan sevinirim
Ami bangla dhsi zoji machine free
Eror7❤❤❤❤❤❤❤❤❤
Machine lack hole e7 dekhay, r ta na hole diver IC change kore dekhun
@@Tech_Repair thank you vai ❤️❤️❤️❤️❤️
Sir ye card error 14 aa rha hai igbt ok hai ir ke baju me 3capicitar laga hai ispe 13 volt 13 volt 13 volt aa rha hai to next step kiya krun
Sensors check karo, sensor ka output voltage check karo, error E14 sensor ke bajay se ata hai
مفيش مترجم عربي
தமிழ் மொழியில்
Im Bangladhes
Banglate bolun
@@Tech_Repair appni bangali
Same modal display bilinking solution please reply
Smps section fault
@@Tech_Repair bana liya controler ko re scolding mara ho gaya
9100Bs pawar problem aloys vibio
ازي بتقايس فولت الموتور
Using a multi meter, check voltage between ground and u, v, w pin. In maximum speed voltage will be 1/3 of DC voltage, for example if DC voltage is 315v then each pin maximum voltage will be about 100v - 105v if the motor runs at full speed.
All pcv
?
Zozi E7 pcb aloys vibio❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤
Motor locked or IGBT shot
Bhai aap 1tar se voltage kaise check kar rahe hai yellow
Du tar hi hai, ak already GND pin par connect kiya huaa hai.
Bhai video banana on circuit par voltage chek karna all components ko please bhai
Taking model Tk-8860
Er-09 help please
Tell me Controller Box model number? Then I can find the exact cause of error-09.
Most probably it's happening due to "encoder phase detection error" .
Sir app number sand kardo
Whatsapp pa video sed kardo ga
Abhi to possible nahi hai, aap motor ka encoder disk ko check karo, or agar hall sensors laga huya hai to voltage check karo, sabi thik se kam kar raha hai yea nehi yea check karlo
ZJ9513-G/02
What is the problem of E14 falling in the machine ?
Check motor hall sensors, and sensor output voltages in pcb
Sensor cheng karo
Bhai bil ka err hai boss Q bebkof banate hu
Sir ji, 'Bil ka err' matlab? Or aap ko bebkof banake mereko koi faida nehi hai, Iss error 09 ko maximum time aise karke e repair kia jata hai... Agar aap koi dusra process pata hai to o vi sare kare, iss se mere ko vi kuch janne ko milega.
Assalamo alikum bhai ye machine me error 9 aa rha hai usme chek kiya to resistor or capacitar ka readin ok dikha rha hai but motor laga chek krta hun error 9 show krta bai kiya yah motor ka sensar se bhi hobsakta hai
Motor ka sath ak plate laga hua rayta hai, usme magnet laga hai rayta hai niddle position detection ke lea, wo disk agar na laga hoga, or niddle position detection sensor kharap hoga to error E09 ayega
@@Tech_Repair sir magnet laga hua sensar apna value theek dekha rha hai
Use pahle app ka vidio dekha tha to ye problem solve gya tha but esbar nhi ho rha hao
Sensor ke pass magnet lake value check kare, ar bina magnet laye value check kare. Bina magnet laye value karib 4v se upar hoga, sensor ke pas magnet lane par value 0v ho jayega. Maximum time yea problem resistance kharab hone par aata hai.
@@Tech_Repair insha allah try krta hun sir
Sir pls contact details
Jack F4 E1 aloys vibio ples❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤
Locked Motor, IGBT shot
Im igbt ceck is ok register ok ❤️❤️❤️❤️
@@mdjabet3956 change driver IC ( fan73892)
1 ta kotha boltam
Ki?
E 14 error same modal
Check sensor
@@Tech_Repair moter senser
Senser sahi tha fir bhi mai change kar Diya tha lekin e14 hi aa raha tha fir mai board me rasistor check Kiya to fault nikla fir mai change kar Diya to sahi ho gaya
@@electricalsidea9873 👍
bhai app apna number dedo bhai
Thora din
Sir ye card me error 15 kis chij ka hai
@@kalimbhaisewingmachine5508 E15 over current ke bajey se ata hai, maximum time IGBT kharab ho jane ki par.
Sir side penal ubt me qixing ka card me error 3 ka ka sulustion batate to aap ka sukrgujar rhun ga
@@kalimbhaisewingmachine5508 konsa model?