AC Compressor makes noise when turns off

Поділитися
Вставка
  • Опубліковано 11 гру 2024

КОМЕНТАРІ • 146

  • @rj.parker
    @rj.parker Рік тому +49

    Probably back emf generated by fan rotation hitting compressor. Can be fixed with double pole contactor with fan hot moved to bottom. Isolates fan from compressor.

    • @Garth2011
      @Garth2011 Рік тому

      Looked like an ECM fan motor. Same applies?

    • @HVACRDUDE
      @HVACRDUDE Рік тому

      Winner winner. 🏆

    • @brunoshvac2578
      @brunoshvac2578 Рік тому +12

      That is not an ECM fan motor on that unit. The it’s definitely a known issue. With TRANE/ American Standard units going back to 2020 16 SEER units and 14 SEER. Seems like we are getting more calls about this on newer units now. We’ve had about 4 this summer so far. Their is a bulletin about this from AMS/ TRANE engineering department. It’s been mentioned already. Change to 2 pole contactor and move run winding for fan motor to L2 from T2. Same way all Carriers come factory wired. Engineering dept states it’s a back EMF issue.

    • @countryfriedhvac
      @countryfriedhvac Рік тому

      Thanks for the learning! I’ll try this next time I run up on this issue

    • @throttlebottle5906
      @throttlebottle5906 Рік тому +1

      yeah, back EMF from one or the other, probably compressor/cap combo hitting the fan motor, that would make the higher pitch bang, especially since it's hooked to giant noise emitters (the top and blades). compressor is generally a dull low tone thump.

  • @jamesvojir8988
    @jamesvojir8988 Рік тому +17

    It's caused from the fan motor. Disconnect the compressor and it'll still make the noise upon shut down. Usually only does it when the pad is not on regular ground but on rocks or cement. Tighten the fan mounting bolts as tight as you can by hand and put vibration pads on all 4 corners of the unit. It's worked every time.

  • @nikcook2340
    @nikcook2340 Рік тому +10

    Nice timing with the hand tap on the downstairs condenser!

  • @TheBaum1
    @TheBaum1 Рік тому +14

    Dam for the money you have to spend on these units, it really shouldn’t make any unusual sounds or vibrations cycling through a shut down sequence ? that would probably indicate a less than optimal life span of trouble free usage down the road? It’s like buying a new car with a bad bearing in the engine, it’s all good until it runs out of the manufacture warranty down the road and then it’s on your dime. Just change out anything & everything in that unit under the factory warranty… until it sounds right. make it run like the other unit next to it does. Kinda hard to tell a customer that “oh it’s ok that’s normal”, when you have a comparison unit sitting right next door and it’s working without the issue.. When you’re retired and done and that unit kicks the bucket down the road , their in for more downtime and aggravation..

  • @joeyf504327
    @joeyf504327 Рік тому +10

    there is another youtube tech who installed Carrier and had the same customer complaint. A loud bang when turning off. He installed a delay timer to turn the fan off a few seconds after the compressor shutoff. It worked well. The noise was completely gone. Just an anomaly that the one specific unit resonated when turning off. Staging the shutdown solved it

  • @Straycurrent
    @Straycurrent Рік тому +7

    Although there may be some back emf factor with these units causing the fan to jerk, I believe the actual clunk can be coming from a loosening of the fan blade shaft bolt. I observed this happening with an Am Std Silver Series CU about two years ago. The noise started like the sound of these units and gradually worsened over a week or two. It eventually resulted in the fan blade falling off the shaft and damaging the compressor discharge line as well as the blade itself. .

  • @jeromes58
    @jeromes58 Рік тому +3

    Your customer should hear my water furnace compressor at turn off. 14 years old and it has hammered at shutdown from day one. Still running fine. Great videos Ted

  • @chatrkat
    @chatrkat Рік тому +2

    Nice to see a pair of new Trane condensers setting side by side.

  • @stress_headache
    @stress_headache Рік тому +2

    You service some absolutely beautiful homes.

  • @elBusDriverKC
    @elBusDriverKC Рік тому +6

    I hear Copeland scroll compressors on Lennox units shut down hard all the time like that. Just a lot of mass moving around then all of a sudden stops.

  • @lonewanderer9872
    @lonewanderer9872 Рік тому +2

    Forever grateful for your a videos, first summer as a service tech and you ans your videos have helped so much. I see so much wrong in a majority of homes I work home , super neglected and i get overwhelmed. I end up at your channel, thank you sir!

  • @khakiswag
    @khakiswag Рік тому +3

    Normal. My XR14 has been doing that since day 1. Running trouble free for 8 years and no problem handling the 100 degree days we’ve been having.

  • @wtgkb8
    @wtgkb8 Рік тому +4

    My American Standard has that compressor shutdown rattle too, but hasn't been an issue for the 9 yrs I've had it make that sound

  • @Big-Rouge
    @Big-Rouge Рік тому +5

    I had a Trane 5 ton unit installed in my new construction 8 months ago and it has the same loud noise when the unit shuts off! The unit runs great and really cools my house in southwest Louisiana. It has been really HOT and Humid down here this summer too!

  • @danwittels5542
    @danwittels5542 Рік тому +12

    I've never seen a Goodman do that! 😅

    • @c.blakerockhart1128
      @c.blakerockhart1128 Рік тому +2

      Goodman high static heat pumps with scroll compressor is louder than that is.

    • @criticalw88
      @criticalw88 Рік тому

      “Dad-gum Goodman”!

  • @zeldamoore8371
    @zeldamoore8371 Рік тому +1

    My trane has noisy shut off too. Almost 3 yrs old now & no issues. Just different from other brand I had

  • @lucidphysics7891
    @lucidphysics7891 Рік тому +1

    ive been working with newer compressors. the ones i learned on in school dont necessarily make that noise because they are older units to be trained on. on the case with the newer compressors, they all stop like that. i just worked on a year old system and when i pulled the disconnect it make that exact same noise. its a manufacturing issue as far as im concerned.

  • @davidspade7654
    @davidspade7654 Рік тому

    Always honest and professional love it brother ❤ not every call is a win but we stay professional consistently finished my last call as a recall was out there last week for annual maintenance she calls us today saying system is down come out right away she explained to me she had a pest control out there two days ago the pest control guy left the power off in the crawl space which killed power to the unit always feels good to be Superman flipping switches

  • @sknight0391
    @sknight0391 Рік тому +2

    The good ol' 410A jolt. 😎👍

  • @Eddy63
    @Eddy63 Рік тому +1

    Good little vid Ted ... Thx

  • @Gaming04-z69
    @Gaming04-z69 7 днів тому

    Upstairs unit shutdown: 2:20
    Downstairs unit startup: 2:39
    Downstairs unit shutdown: 3:36

  • @camac57
    @camac57 Рік тому +2

    Mine makes the same noise. Same unit. Six years old. No problems

  • @mattmishoe157
    @mattmishoe157 Рік тому +2

    As I was watching intently and turning the volume up, I got scared I was gonna get a full screen scary face and scream from back in the day. 😂

  • @quaarjet
    @quaarjet Рік тому +2

    The smaller unit seems like the compressor shut off bump is louder.

  • @frankchris07
    @frankchris07 4 місяці тому

    I like your videos and steven lavimoniere you 2 make great material to watch.

  • @stevekline5608
    @stevekline5608 Рік тому +2

    My Trane is doing same thing. My Tech said if I installed a soft start it would reduce the start up and shut down noise. It didn't help at all. Did I get scammed?

  • @Sesamestreet9080
    @Sesamestreet9080 Рік тому +1

    Carriers have problems with scrolls when they shut off they make a thud sounds it’s because a valve is worn inside the compressor

  • @mikenonameneeded3485
    @mikenonameneeded3485 Рік тому +1

    I have the same 4 ton Trane XR. Installed 2015. Mine makes the same noise. No worries here.

  • @XGamesJ6
    @XGamesJ6 Рік тому +1

    I often get a whistling sound from my system after it satisfies. I assume it's the pressure equalizing in the lines/coils.

  • @Channel-cm7yc
    @Channel-cm7yc Рік тому +1

    Scroll unloading is what it sounds like to me? My Amana does the same exact thing and it’s 10 years old and has always done it.

  • @mariachurch9275
    @mariachurch9275 Рік тому

    I have a 2023 amer Stan silver that started doing this 4 wks after install. The installer tells me its normal with the new compressor design. I wish they could do something to quiet it down. It runs quiet and the entire system with blower installed. It’s going to get used a lot in Az. Kicker is if the rotary designed compressor wears out the entire compressor needs replaced. 10 year warranty I hope has me covered if it happens.

  • @pya102
    @pya102 Рік тому +2

    We have a Trane installed in 2018 and makes the same noise. If you find the cause/remediation please share. It’s mostly a mild annoyance.

    • @c.blakerockhart1128
      @c.blakerockhart1128 Рік тому

      Sadly it is just the sound they make on shut down. The compressor becomes torqued in one direction while running and the sound is the compressor immediately releasing the torque.

  • @jeffsworld2
    @jeffsworld2 Рік тому

    I have a new 3 year old system, not a Trane, that does the same thump. Mine is more at start up. I questioned it as well and was told that all the new style compressors will do this, clutch noise I believe

  • @unorthodoxridez
    @unorthodoxridez Рік тому +1

    Do you think that the compressor could be loose and when it torques on shutdown that it moves slightly? That definitely doesn't sound good (acceptable) on the first unit especially if it's new. I'm not in the business but as a consumer if I paid to have that put in I wouldn't want it to sound like that.

  • @j.rcoker9051
    @j.rcoker9051 Рік тому +1

    My Rheem does the same thing as the smaller one...always has and actually sometimes its louder.

  • @erinm9534
    @erinm9534 Рік тому +1

    Good job ted❤😂🎉

  • @cyberlight22
    @cyberlight22 Рік тому

    That was funny right as you touch the second unit turned on Great video

  • @Paul-IE-Repairs
    @Paul-IE-Repairs Рік тому

    that sounds like normal the valve noise. When the compressor stops there is still head pressure and motor will shutter back and forth a few cycles until the opposing forces equalize and the motor stops in a neutral position.

  • @robalexander7348
    @robalexander7348 Рік тому +1

    Ted, Please don't oil that squeeky hinge on your work van, we all look forward to that squeek when you arrive at the next job, and open the door 😀 👍 Au

  • @hvacjay3201
    @hvacjay3201 Рік тому

    Had this issue and trane sent me a 2 pole contractor and I was skeptical but it did work. No more noise on shut down.

  • @clintgray1623
    @clintgray1623 Рік тому

    Looks like the installers could turn some of the units 90 degrees to allow for easier service, the control panel and service area, if heat pump would be a lot easier to service

  • @gregnettles3677
    @gregnettles3677 Рік тому +1

    I have the same 4 ton unit does the same thing had it installed in 2017 zero issues

  • @joeshearer1247
    @joeshearer1247 Рік тому +35

    Its that fan thump noise I can make it stop doing that with a double pole contactor

    • @ChingusTheOneAndOnly
      @ChingusTheOneAndOnly Рік тому

      Joe knows , I remember that video

    • @danwittels5542
      @danwittels5542 Рік тому +1

      That's interesting, maybe Ted will try that, I'd like to know if it works.

    • @jasonshearer1870
      @jasonshearer1870 Рік тому

      Yup, you should make a video on that

    • @lucidphysics7891
      @lucidphysics7891 Рік тому +1

      sure would love for you to show me, I always want to learn how to get a customer off my back lol. please make a video on your solution to prove your hypothesis.

    • @bills6946
      @bills6946 Рік тому +6

      I only install double pole contactors when they need replacing

  • @irisbaez1972
    @irisbaez1972 Рік тому

    I bought a brand-new Amana 4 ton, and it does the same noise at stop. I thought was the fan blades, but I stand closed to the compressor and I hear from there and it feel like clan,clan,clan when is stop. it looks like the compressor when it stop. Maybe cause its bran new and the piston inside do that.

  • @nekochristmas
    @nekochristmas Рік тому

    I just got a brand new Rheem 5-ton 19seer installed and the compressor makes a chattering sound when it turns off, hopefully that's normal operation 😅

  • @onenikkione
    @onenikkione Рік тому

    We had a Trane 5 ton installed in Jan 2021and ours makes a rattle/noise when it shuts off.

  • @chetmyers7041
    @chetmyers7041 Рік тому

    2:16 Smaller unit switches off with clunk. 3:33 2nd unit makes no thump sound.

  • @uxwbill
    @uxwbill Рік тому +3

    That definitely doesn't sound unusual to me.

  • @cthomaspac
    @cthomaspac Рік тому +2

    The scroll compressor , upon shutdown will make that noise . It's the pressure in the system that actually pushes the scroll backwards for a brief moment. It is Totally normal. On the trane csha scrolls (15 ton) upon shut down they actually turn bakwards for up to 2-3 seconds. Take is easy bro.

    • @ronaldclark8187
      @ronaldclark8187 Рік тому

      That sounds like the reasonable explanation.
      The early type rotary used to tick while equalizing.
      Back EMF,resonance,moving loads around.IDK about that shyt.

    • @HonestyHVAC
      @HonestyHVAC Рік тому

      Yeah idk what everyone is talking about the fan making the noise, bigger scroll compressors do it unmistakably so that’s probably why I know it’s the compressor

  • @WayneBain
    @WayneBain Рік тому

    I have one that makes 10-12 knocks on shutdown. Sounds like someone threw a handful of rocks at it. My service company ordered me a new compressor (scroll) but said to wait until the old one failed as it was working perfectly and using no more electricity than a new one. That was three years ago and it still works perfectly just noisy on shutdown. I don't know if it is a rattling seal or what but pressures are perfect. I just knew it would throw in the towel a long time ago but it has not.

  • @tc7922
    @tc7922 Рік тому

    Compressor sounded fine on shut down… sounded like the fan motor to my ear … I have had the same complaint from customer that has a Trane package unit.

  • @Garth2011
    @Garth2011 Рік тому +2

    Interesting...if those were mine and under warranty...I would for sure be communicating with Trane ! Yes very minor but NOT really normal so Trane should correct it. By the looks of previous comments, maybe it should have a dual pole contactor?

  • @fatalberti
    @fatalberti Рік тому +1

    had my compressor on my new 2021-22 trane unit go out at 13 months. original compr indicated made in louisiana. replacement was proudly made in china. maybe pandemic conditions resulted in reduced quality control on new trane. but if a trane laid down after a year can you expect any mftr to be reliable?

    • @applianceman6009
      @applianceman6009 Рік тому

      Trane does not use Chinese compressors. Some have LG compressors, and those are made in Korea. Most include an Alliance, and they are still made in Louisiana from what I have seen. Maybe yours was a certain batch.

  • @myHVAClife
    @myHVAClife Рік тому +1

    We get those calls all the time, nothing wrong. Just homeowners! Sounds fine to me.

  • @mistervacation23
    @mistervacation23 6 місяців тому +2

    Mine makes a thump sound when it shuts off is it serious?

  • @krishnakandula6587
    @krishnakandula6587 4 місяці тому

    My Lennox unit purchased last year does this. A little more louder in fact. Would it impact the functionality or lifetime of the system ?

  • @SteveM-426
    @SteveM-426 Рік тому

    I have a Goodman that makes those sound like a mouse with slippers! LOL!

  • @kristinetibbits5873
    @kristinetibbits5873 4 місяці тому

    Mine is new. Makes a gun shot noise when turning on and off. I wish mine was as quite as these 2 you filmed

  • @eddiee2371
    @eddiee2371 4 місяці тому

    I would first check the mounting of everything. If it were a car, i'd check the motor mounts. With this, i'd go for the fan, compressor and even the unit itself. Trane may have left out a rubber bushing.

  • @watermanone7567
    @watermanone7567 Рік тому

    Are the compressor mounts o.k. and not split. I use to see this on some refrigeration units. Thanks

  • @wmalden
    @wmalden Рік тому

    My 2014 Bryant 3 ton makes the same noise on shutdown. No problems. Normal.

  • @damonried1720
    @damonried1720 11 місяців тому

    Yes, the noise may be normal, however, what is CAUSING the noise? Is it from 'fluid shock' when a valve shuts closed suddenly?

  • @fastzombie1
    @fastzombie1 Рік тому

    Even the Copeland scrolls make that hissing noise when they shut down.

    • @davo912
      @davo912 Рік тому

      open you listen ears..it was no hissing noice

  • @The.Lone.Wolf.
    @The.Lone.Wolf. Рік тому

    Backpeddling or back spin upon shut down mine does that too it's a scroll compressor kinda annoying but what're you gonna do....

  • @powerstorke03
    @powerstorke03 8 місяців тому

    Do you ever have issues with the scroll coming apart in the compressor?

  • @kadeemhall6602
    @kadeemhall6602 4 місяці тому +1

    So noone is recognizing that bruh got lost in his own home.

  • @mattluongo7763
    @mattluongo7763 Рік тому +1

    That was the fan motor, not the compressor.

  • @dimbag1
    @dimbag1 Рік тому

    Need to put some W D 40 on that door hinge giving chevy a bad name big Ted.

  • @DanTheManIOM
    @DanTheManIOM 6 місяців тому

    should a newly installed compressor make noise on start up ? like cavitation or a "rod knock" on start up ? I'll have to record it, BUT, I am not getting the same idiot who came out the last time. Yes, coincidently I had a FIRE in my fuse panel starting at the AC circuit breaker WHILE he was here working on the unit.

  • @United_HVAC_and_Fans
    @United_HVAC_and_Fans Рік тому

    Some people amaze me

  • @Ageehvac
    @Ageehvac Рік тому

    The Hvac G.O.A.T

  • @jameskoch7780
    @jameskoch7780 Рік тому

    Hi Ted do you know or have talked to Curts the HVAC GUY?

  • @FB-111A
    @FB-111A Рік тому

    I have two carrier units that makes a similar noise on start up. Both units were installed when the home was constructed in 1999. They continue to perform effortlessly in the humid Louisiana climate.

  • @hvacrefrigeration5204
    @hvacrefrigeration5204 Рік тому

    Never seen that too, should call to tech support to get some opinion about it.

  • @Perly53
    @Perly53 Рік тому

    My next door neighbors newly installed Trane makes a loud clunk every time it shuts off. It doesn't seem normal to me.

  • @c.blakerockhart1128
    @c.blakerockhart1128 Рік тому

    That's just the way a scroll compressor sounds. It's spring loaded from the sound of it.

    • @davo912
      @davo912 Рік тому

      problem is it didn't do it when it was new did it? Only because it's a Trane does he think its ok.

  • @adriancressy8363
    @adriancressy8363 4 місяці тому

    that's just a little normal rattle from the compressor shutting down

  • @BurtBartlow
    @BurtBartlow Рік тому +1

    Scroll compressor. That's what they do.

  • @normandriscoll3320
    @normandriscoll3320 Рік тому

    Normal sound for a rotary compressor. Their valves behave differently for a reciprocal compressor, and this is perfectly normal.

    • @joshmc4328
      @joshmc4328 Рік тому

      I for one do not believe it's normal, maybe with these two-stage compressors nowadays but it is definitely not normal on a basic compressor, I would like to find a way to drop down to first stage before shut down, I can tell the difference in sound from first to second stage, I have a f****** geothermal unit and as loud as f*** in the house... makes you want to run and go look and make sure you ain't got no lines blown off an flooding your house...lol

  • @MOAONAABE
    @MOAONAABE Рік тому

    my carrier is 2 years old and it clunks when it kicks off, and it clunks when it turns on. it replaced a trane i installed in 1990

  • @austinanderson32
    @austinanderson32 Рік тому

    Have a American standard which almost a year old. It does the same thing also

  • @joeduck348
    @joeduck348 Рік тому +1

    Omg. Good luck with comment sir 👍

  • @timcastilo6962
    @timcastilo6962 Рік тому

    Holy moly put some WD-40 on your van door hinges 😂

  • @Austin23191
    @Austin23191 Рік тому

    I added a compressor blanket to my AC yesterday and it cut down on the noise considerably.

  • @garrettrush1467
    @garrettrush1467 Рік тому

    Completely normal. However you would think nowadays they would make even basic compressors quieter. They have the technology just don’t want to spend the money.

    • @111000100101001
      @111000100101001 Рік тому

      Sadly for customers the mfg keep trying to cut cost out and keep function. Notice how much lighter a same capacity, new compressor is vs one from 15yrs ago?

  • @rcpasc1948
    @rcpasc1948 Рік тому +1

    My 4 ton does that.

  • @rubberman2006
    @rubberman2006 Рік тому +1

    Hate to see his electric bill having 2 units cooling that house.

  • @krob08
    @krob08 Рік тому

    Trane has got be one of the best ACs out there.

  • @roynewling6599
    @roynewling6599 Рік тому

    I had one do that it was the rubber grommets on the anchor bolts

  • @Ageehvac
    @Ageehvac Рік тому

    I had a damn goodtime on a trane system with a bad recip the other day....

  • @finallyanexpert.301
    @finallyanexpert.301 Рік тому

    I usually have to be standing around 15 feet away to isolate the compressor vs fan sounds but from the video it sounds like something is missing from the functionality of something 🤷🏻‍♂️ if they donate that unit to my not for profit conditioned space laboratory I could send them some stickers or maybe a hat

  • @mikeniehaus7872
    @mikeniehaus7872 Рік тому

    My Trane XR makes the same noise. It is only a year old.

  • @hvacwonders7081
    @hvacwonders7081 Рік тому

    What are they talking about? That wasn’t that loud shutting down

  • @OnusBones
    @OnusBones Рік тому +1

    Any possibility the compressors are loose on their mounts, and just need to be tightened down a little?

    • @HVACRDUDE
      @HVACRDUDE Рік тому

      😅😅😅😅😅 wow

    • @c.blakerockhart1128
      @c.blakerockhart1128 Рік тому

      Not very likely. They are torqued at the factory. Occasionally that may be the case, but not very likely. It is the sound that a scroll compressor makes when shutting down. The noise could actually be reduced by loosening the bolts just a little, but make sure to dab a bit of rtv across the bolt to prevent it from backing out more.

  • @ntsecrets
    @ntsecrets Рік тому

    Play a video of a Goodman turning off and he will feel better

  • @Kartertheblackmamba
    @Kartertheblackmamba 7 місяців тому

    Sounds fine lol. They just don’t understand how their units work…

  • @TheBrad605
    @TheBrad605 Рік тому

    My brand new ac unit makes same noise when it shuts off.

  • @alanwagen
    @alanwagen Рік тому

    My neighbors Trane makes the same noise.

  • @negan454ss
    @negan454ss Рік тому

    Scroll compressor are noisy on shutdown

  • @noahholt482
    @noahholt482 Рік тому

    She makes a lot of noise when satisfied ey