British plugs with built-in surge arrestors. (With schematic.)

Поділитися
Вставка
  • Опубліковано 23 січ 2025

КОМЕНТАРІ • 382

  • @interstat2222
    @interstat2222 5 років тому +4

    These are by PMS, Hong Kong company called PMS Ming Kee. They've been making plugs in the UK since at least the mid 80s but the company is 40 years old. You used to find them in market stalls but they've proven to be good quality and widely available under own brands such as CPC, Morrisons etc and found on many small appliances. The design hasn't changed since the 80s and they're generally one of the better plugs on the market (although they’re using cheaper plastics as time goes on).
    Before PMS started doing this surge version in the 2000s, WG/Volex (in the 80s/90s) made a UK made surge protected plug like this.

  • @LND3947
    @LND3947 5 років тому +26

    I love how simple it is, and the way it uses off-the-shelf standardised parts, like the spring loaded pins
    Thanks for the video Clive :)

  • @ewozniak5228
    @ewozniak5228 5 років тому +87

    D is disk type (size in mm) K is Tolerance +-10%

    • @flow5718
      @flow5718 5 років тому +7

      Thanks!

    • @uzaiyaro
      @uzaiyaro 2 роки тому

      Ditto! Thank you very much!

    • @godfree2canada
      @godfree2canada 11 місяців тому

      D for Dont need no fuse ;-)

  • @jfan4reva
    @jfan4reva 5 років тому +2

    I remember back in the early days of PCs, someone wrote a column about adding MOVs to power strips to add surge protection. Within a month, most U.S. Radio Shack stores were completely out of MOVs. Soldering in 3 MOVs was simple, easy and effective, but I don't recall anything about adding thermal fuses. Unlike now, surge protected power strips would cost upwards of $50-$75, and were difficult to find because they were 'commercial' products.

  • @nickf3242
    @nickf3242 5 років тому +2

    Always love when Big Clive is surprised by a tear-down. "That's quite cleaver." Such a simple video but yet still entertaining. I'm getting more and more jealous from not having regular 240 volt here in the US.

  • @PaulFisher
    @PaulFisher 5 років тому +10

    These seem like they are pretty good as surge protectors go, apart from their lifetime being fairly short if your lines are noisy. Most cheap surge strips I see in the States only bridge LN (no LG or GN), and many lack any kind of indicator of whether they are still actually providing protection. That this one also seems well-built and cleverly engineered is a bonus.

  • @ecospider5
    @ecospider5 5 років тому +2

    I do like surge protectors that don’t shut off when they stop protecting. I have never met a non electrical person that pays any attention to the light going out. But the beauty of this design was that they didn’t have to interfere with the existing plug design. I wonder if they could add a buzzer when it stops protecting. This would also help when the plug is out of site behind a piece of furniture.

    • @anononomous
      @anononomous 5 років тому +1

      I'd concur with that. I wonder how many surge protectors in use are actually providing protection any more. I seen a fair few that aren't. People just tend to assume the wouldn't work at all if that was the case.

    • @ecospider5
      @ecospider5 5 років тому

      I have found the surge protectors that offer an attached device warranty are the ones that will shut off when they stop protecting. I’m constantly checking family and friends computers to verify they’re plugged in to a proper surge protector. Since I’m going to be the one that has to replace their power supply. They are always so confused that I tell them their surge protector did not protect them when they were plugged into one that didn’t shut off.

  • @papaalphaoscar5537
    @papaalphaoscar5537 5 років тому +3

    There are actually MOV's with series thermal fuses integrated into a single package. Littlefuse makes them, makes layout and design or adding protection to an existing circuit very simple.

    • @AlexLaw_Qld
      @AlexLaw_Qld 5 років тому +3

      and this is why I read the comments, knowledge is power.

  • @EsotericArctos
    @EsotericArctos 5 років тому +1

    I like the image the camera you used on this video has given. It's a crisp clear focus, but a slightly warmer picture, yet the white is still a nice, clear white.
    Sound is good too.

  • @martinwinfield2935
    @martinwinfield2935 5 років тому +1

    Thanks Clive, great clear explanation as usual. Nice that you will look at some of the more overlooked items that we have around the house.

  • @webchimp
    @webchimp 5 років тому +5

    I've had one of those on my computer power lead for many years, just realised I've never checked it see if the MOVs are still OK. It doesn't have the neon so no obvious outward indicator it's still working.
    edit: had a quick look, it's a similar design but the components are potted.

  • @111chicane
    @111chicane 5 років тому +2

    That's a great improvement over the standard plugs! I'd love to see this in US plugs too.

  • @thesewalkamongstus8367
    @thesewalkamongstus8367 5 років тому

    You've just given me another project to add to the list! I am busier now that I am retired than ever when I worked for a living!! Top work Big Clive!! hahaha!

  • @SeanBZA
    @SeanBZA 5 років тому +2

    Got a 33D00061 unit, which is rated for 480VAC. 470VAC will not clamp most small pulses, but will do big ones. you only need 2 thermal fuses, as they only need to disconnect 2 out of the 3 wires at most for the unit to not work.
    I have made many DIY versions, using a single MOV, 275V, inside a standard 16A plugtop, as they do work well to clamp spikes. The MOV units tend to fail short circuit and trip the breaker, but here the breaker is 20A, not a 32A one used in the UK, where you instead use fuses in the plug instead. Not sure which system is safer overall, both have pros and cons.

  • @hene193
    @hene193 5 років тому +17

    I absolutely love the mic in this camera! So soft and bass heavy 😍

  • @Koishichan
    @Koishichan 5 років тому +6

    I must be missing something. The standard plug base connects the cable of your device directly to the outlet through the fuse. How does the additional PCB bit do any protecting if it can't actually break any connection?

    • @davepusey
      @davepusey 5 років тому +15

      It doesn't break the connection, it just sits in parallel with the load and shunts any excess supply voltage to earth.

    • @Koishichan
      @Koishichan 5 років тому

      Dave Pusey, Ah ok. Thanks for explaining.

    • @jammin023
      @jammin023 5 років тому +4

      @@davepusey Thanks. I feel like, unusually for Clive, the video was rather lacking in explanation for how it actually works.

    • @plasmatorque4318
      @plasmatorque4318 4 роки тому

      @@davepusey Since there is a thermal fuse in series with the MOV, it would probably blow the thermal fuse and protect the MOV during a surge. The connected device will still be connected to the outlet without any protection.

  • @cannotbeleftblank6027
    @cannotbeleftblank6027 5 років тому +4

    For some reason the picture is sharp on the right side but unfocused elsewhere. It's quite apparent with the notebook in view.

    • @Petertronic
      @Petertronic 5 років тому

      This is a common anomaly on phone cameras

  • @YTANDY100
    @YTANDY100 5 років тому

    one reason for incorrectly wired sockets is the fact that different makers put the connections were they like so if someone goes to b+q or some such and gets nice new shiny sockets , switches off the power and removes old socket and fits new socket they will just fit the wires same as old socket which may have L + N opposite way round , when they plug something in to test it works , job done :-)

  • @spektrum33
    @spektrum33 5 років тому +19

    I like the technical term you use 🤔. It may go boing 😉...

    • @LeifNelandDk
      @LeifNelandDk 5 років тому +2

      - but that's ok ;-)

    • @cdl0
      @cdl0 5 років тому +1

      Big Clive must be a Scot. The English would say "fatang". :-)

  • @paulaj2829
    @paulaj2829 5 років тому

    i have used one for 20yrs now & never had a problem.. very interested in your video..

  • @Leonard_Smith
    @Leonard_Smith 5 років тому +8

    Re: Audio / Video equipment. Sometimes older is better. and this video is an example that shows that to be true.
    Onwards towards 1 million subscribers!

  • @vijendrashirodkar9247
    @vijendrashirodkar9247 5 років тому +1

    Clive i was thinking that why they are not using 10d371k mov.voltage will not go above 370v.

    • @Monkeh616
      @Monkeh616 5 років тому

      Because with 10% tolerance a non-trivial number will conduct every cycle, and even those which don't will have short lives.
      Plus, the greater energy dissipated will cause more heating of the MOV and shorten their lives even further.

  • @ElmerFuddGun
    @ElmerFuddGun 5 років тому +2

    British plugs are just soooo huge. Glad Canada uses the small 120V plugs! :-)

    • @SeanBZA
      @SeanBZA 5 років тому +3

      Yes, so easy to grab the live conductors as well. No wonder the standard method to remove is to pull out by the cord, because the plug is small, there is no sleeved end and of course the sockets have no switches to disconnect them either.

    • @ElmerFuddGun
      @ElmerFuddGun 5 років тому +2

      @@SeanBZA - Yet as a Canadian I never hear about anyone touching the live connector. They aren't hard to pull out but true that some people are lazy and grab the cord. They take the abuse. 120V is great for the vast majority of items and we have 208 and 240V for the big stuff. We do have switched sockets but they are usually just for a lamp outlet on the other side of the room. Don't need it otherwise.

  • @GrahamDenison
    @GrahamDenison 5 років тому +1

    There used to be fridge power loss alarm plugs that used a similar construction.

  • @petehiggins33
    @petehiggins33 5 років тому +3

    It occurs to me that if you just plugged one of these into the sockets at each end of a ring main, then it should provide reasonable protection for everything else plugged into that ring. There's no need to actually wire them into any appliances unless you're short of sockets.

    • @Monkeh616
      @Monkeh616 5 років тому +2

      Remind me where the end of a ring circuit is again?

    • @leexgx
      @leexgx 5 років тому

      @@Monkeh616 end of the house and start of the house, I guess having one plugged into each room would work as well, the more you have more likely they adsorbed the spike over each spd
      but generally they more effective if they are before the device that is been supplied like an extension cable with all your electronics plugged into that (or in the consumer unit as is starting to happen )
      Belkin with there surge master line socket and 4-8 way extension leads having doing it for a very long time

    • @petehiggins33
      @petehiggins33 5 років тому

      @@Monkeh616 The two ends of a ring main are the first socket and the last socket going clockwise or anticlockwise in the southern hemisphere.

    • @Monkeh616
      @Monkeh616 5 років тому

      @@petehiggins33 First socket from where? It's a ring. And yes, I appreciate you mean the first one along the run from the CU. These really only provide very, very basic protection, though.

    • @petehiggins33
      @petehiggins33 5 років тому

      @@Monkeh616 Clearly it would be better to fit a proper surge protection device like this tinyurl.com/r8a2vpf in the consumer unit but they are expensive and should only be fitted by an 'electrician'. But if you were thinking of using these relative cheapies to protect a couple of appliances then my suggestion would give the same level of protection to all the sockets on the ring for the same cost. You need to use two because the transient will travel in both directions around the ring and the suppressors will only protect sockets downstream of the wiring.

  • @Peter_S_
    @Peter_S_ 5 років тому +1

    The color temperature of that camera looks very nice. It's an inviting warm with nice balance however the focus on the other hand seems a hair dodgy. It's sharp as can be in the upper right but the left 1/3 of the image seems quite soft, especially toward the bottom.

    • @davidworsley7969
      @davidworsley7969 5 років тому

      FFS-It's a neon indicator !- Sheech !!

    • @Peter_S_
      @Peter_S_ 5 років тому

      @@davidworsley7969 Too much coffee, lad. I was referring to the picture quality. Did you get enough sleep?

    • @davidworsley7969
      @davidworsley7969 5 років тому

      @@Peter_S_ You were ?....Well.....Who'd have thought ? ZZZzzzzzzzzzzzzzzzzzzz.

    • @Peter_S_
      @Peter_S_ 5 років тому +1

      @@davidworsley7969 When is the last time you saw a neon indicator that had a sharp image in the upper right but the left 1/3 of the image seems quite soft? Doesn't add up.

    • @davidworsley7969
      @davidworsley7969 5 років тому

      @@Peter_S_ You woke me up to ask me that ? Where is your humanity ?

  • @RubenKelevra
    @RubenKelevra 5 років тому

    Very crisp sound with good bass. Keep this setup.

  • @RomanoPRODUCTION
    @RomanoPRODUCTION 5 років тому

    Clever analysis dear Clive

  • @joehole1947
    @joehole1947 5 років тому

    The connection is pogo pins or spring loaded pins, they are becoming more popular with electronic manufacturers as the board connection is just pads ecthed into the circuit design and no cost in parts so the programming connector or test connector is pushed against a set position and makes the connection.

  • @zx8401ztv
    @zx8401ztv 5 років тому +15

    Go on swap the tops so you have two tone plugs :-D

  • @tomgeorge3726
    @tomgeorge3726 5 років тому +1

    Hi Clive, great video.
    The reason for the thermal fuses in contact with the MOV, would possibly be because when MOVs fail, they do as a short and usually split open.
    So at sometime they probably get hot, the fuse is to prevent the smoke an flame from occuring.

    • @aaronbrandenburg2441
      @aaronbrandenburg2441 5 років тому

      Yes that is correct.
      Once I saw a surge protector after lightning strike catch fire a little while afterwards.
      Not at my place somewhere else.
      Use the fire extinguisher on that one.
      Also nice user image I see your fan of Lego.
      On what Minifigures did that come from I'm sure it's an hodgepodge of them.
      Are you with adult fan of white girl like me?

  • @JessicaFEREM
    @JessicaFEREM 5 років тому +5

    picture quality is fine, but zoomed in a bit blurry. softer than it should be

  • @twocvbloke
    @twocvbloke 5 років тому +1

    Pretty neat design, especially the way it utilises a standard plug... :)

  • @ElectraFlarefire
    @ElectraFlarefire 5 років тому +1

    If you have some spare tops, you can replace them when they get damaged.
    Also; I thought they often used LEDs because if you get a spike big enough to destroy the LED, then there is a good chance that the protection has failed?

    • @aaronbrandenburg2441
      @aaronbrandenburg2441 5 років тому

      You may have a point there but it's probably because the car me and stuff but I don't know anyone that guy comments on that?

  • @K-o-R
    @K-o-R 5 років тому +7

    Interesting, so not an in-line protective device, but more like a voltage-detecting shunt?

    • @bigclivedotcom
      @bigclivedotcom  5 років тому +8

      Yes. Just shunts transient spikes.

    • @gromett
      @gromett 5 років тому +3

      @@bigclivedotcom Would they protect against a nearby lightening strike? Is so I will buy a few for my computers etc.
      Excellent video, thanks Clive.

    • @millomweb
      @millomweb 5 років тому

      @@gromett Are you asking if the computers will be fine after the house has been vaporised by a lightning strike ?
      I suspect the first thing you should do is assess the likelihood of a strike.
      This could be an interesting consideration for when I next trim the trees.

    • @YTANDY100
      @YTANDY100 5 років тому +3

      @@millomweb
      he did say nearby strike :-)
      but it would be impressive if the house was blown to bits and the computer was standing there good as new :-)

    • @teardowndan5364
      @teardowndan5364 5 років тому +1

      @@gromett Power line surge suppressors alone won't save you, you need proper grounding so surges don't travel through alternate paths such as AC->PC->HDMI->TV->STB->coax. For higher value equipment, I'd rather have a better-rounded surge suppressor with in-line chokes (ex.: Tripp-Lite isobar) to soften transients and give its multiple 20Dxxx MOVs a better fighting chance against whatever is left.

  • @MalagasOnFire
    @MalagasOnFire 5 років тому

    Need to check if there is a shucko F type with MOV, but mostly the F type is big a bulky plug-in socket. Not to say that the british plug is bulky by any means, since it carries a fuse holder just in case.... as for the MOV reference search the part number and check the datasheet, first pages, eg little fuse.
    Mic is very crystal clear with voice.

  • @crashk6
    @crashk6 5 років тому +3

    Those brass springy bits are popularly known as "pogo pins".

    • @techfreak244
      @techfreak244 5 років тому +2

      but brass springy bits sounds way better

    • @millomweb
      @millomweb 5 років тому +2

      It's not what they call them in the railway industry. There, they call them.....
      ....BUFFERS !

    • @theskett
      @theskett 5 років тому

      @@millomweb Thanks, I LOL'd :-)

    • @millomweb
      @millomweb 5 років тому +1

      @@theskett It's true ! I should have gone to bed an hour ago :)

  • @beware_the_moose
    @beware_the_moose 5 років тому +6

    "odd but clever" describes CPC pretty well

  • @grantrennie
    @grantrennie 5 років тому +3

    Haven't seen one of those plugs since 2001 👍

  • @jonnno100
    @jonnno100 5 років тому

    Interesting, I don't quite follow how it protects against surges if it's just touching the screws on the wire connectors. Doesn't that mean any surge can just go down the wires unimpeded? It's not between the mains and the appliance as far as I can see so I just don't get how it works.

    • @bendito999
      @bendito999 5 років тому

      These are metal oxide varistors , if you connected one in series with your equipment then it would get 0 power unless there was a spike then it would get the spike lol, and go back to being off. Basically giving you only spikes.
      Think of a how a diode is like a one way check valve, these are like a 2 way 'check valve' but with a very stiff spring (though they are not built with diode it's just an analogy)

  • @allanmcnair
    @allanmcnair 5 років тому +1

    Very rich sound and good video - stick with it sir

  • @jeremytoms5163
    @jeremytoms5163 5 років тому

    They look like a good idea, if they go the top half can be replaced without disturbing the wiring. I've got the power strip embedded type here, no issues so far. As for your domestic sockets - a case of Part P kitchen fitters ? Not that I have anything against kitchen fitters, just believe their bloody hands should be cut off if they play with electrics ! Discovered in my kitchen 2 sockets in 2.5mm T&E and 1 in 1.5mm T&E all in a 15 amp choc strip. Earthing cable to the earth rod had been cut to get a unit flush to the wall. Thank god I still had a metal gas pipe. New earth rod and wiring done straight away.

  • @ferrumignis
    @ferrumignis 5 років тому

    Not totally keen on the spring connectors, a high resistance connection between the screw head and the plunger or between the two sliding parts means the surge protection wouldn't be effective but could still pass sufficient current to light the neon.

  • @eliotmansfield
    @eliotmansfield 5 років тому +2

    Is there any way of demonstrating or showing them actually working? Maybe one for John Ward?

    • @PsiQ
      @PsiQ 5 років тому +1

      Clive has the insulation tester which goes to 1kV or more if i'm right.
      it should clamp down to around 270V then.

    • @Monkeh616
      @Monkeh616 5 років тому +1

      @@PsiQ Being 470V MOVs, I'd go with closer to, uh, 470V.

    • @PsiQ
      @PsiQ 5 років тому

      @@Monkeh616 um, aah, was thinking of the ones i've seen lately which were rated at 275V/1mA i think
      Was it 230V +/- 10% for allowed tolerance ?
      (Wouldnt work for 230 x 1.4 peak hmmm )

    • @Monkeh616
      @Monkeh616 5 років тому

      @@PsiQ Something rated at 275V was probably rated for AC - which makes it a 390V part.

  • @Miata822
    @Miata822 5 років тому +2

    Efficiently made and seems to be of good quality. I have not seen a similar product in the US. Here I have only seen large MOVs on poser distribution strips and backup power supplies. Usually the whole unit is thrown out when someone notices the neon has gone out. That's a lie. Nobody ever checks the neon.
    I do check and replace MOVs. I have heard MOVs wear down over time, with every tiny overvoltage hit eroding the internal bits a little. Don't know if that's true.

    • @bigclivedotcom
      @bigclivedotcom  5 років тому +4

      They do fail progressively over time with each transient absorbed, just as you mentioned.

    • @uK8cvPAq
      @uK8cvPAq 5 років тому

      @@bigclivedotcom Can they cause ghost RCD trips when they age then?

    • @Monkeh616
      @Monkeh616 5 років тому

      @@uK8cvPAq They can, although usually they're terrifyingly hot before that occurs, which is where the thermal fuses come in.

  • @Akira42
    @Akira42 5 років тому

    So if I understand right, this is more for indication than for protection, as the connection is never broken to the device, but the neon indicator goes out when there has been a surge? It wouldn't actually protect your equipment from said surge but only provide evidence that there has been one?

    • @bigclivedotcom
      @bigclivedotcom  5 років тому

      It will shunt spikes and transients. It wouldn't deal too well with a direct lightning strike.

    • @Monkeh616
      @Monkeh616 5 років тому

      @@bigclivedotcom Very little does, really.. Lightning has a tendency to win.

    • @Akira42
      @Akira42 5 років тому

      @@bigclivedotcom I feel like I'm missing some basic knowledge here because I can't see how a circuit can protect a device while the circuit to the device remains in place, if you know what I mean. Don't get me wrong, I'm not saying it doesn't work, I just can't see how it does work.

    • @patrickwigmore3462
      @patrickwigmore3462 5 років тому +1

      ​@@Akira42 The MOVs become temporarily low-resistance when the voltage rises high enough to trigger them, causing a temporary short circuit. Because the electrical wiring has non-zero impedance, the short circuit causes voltage drop in the wiring, dragging down the voltage and protecting the appliance. Normally this will only be for a very short period of time (milliseconds).
      Considering each MOV individually, the wiring and the MOV together form a potential divider across the origin of the voltage spikes. When the MOV is not conducting, its resistance is much, much higher than that of the wiring, so most of the potential difference (voltage) is across the MOV and thus also across whichever parts of the appliance the MOV is in parallel with. When the voltage rises and the MOV begins to conduct, the MOV's share of the total circuit resistance falls, and thus its share of the potential difference also falls.
      (Someone correct me if I'm wrong.)

    • @Akira42
      @Akira42 5 років тому +1

      @@patrickwigmore3462 Thanks for explaining, I think I get it now. The devices don't get 'in the way' of the surge, they draw it away from the equipment instead and dissipate it, I guess is how I would put it?

  • @ghjdhghj1
    @ghjdhghj1 2 роки тому

    I want to know how a complex surge protector with filtration works as opposed to this simple one. Like a Thore surge protector...

  • @Mr.T4LLY-0
    @Mr.T4LLY-0 5 років тому +1

    Sound good. Image seems to have a gradient from left to right. Right side being more in focus. Colour a tad too rich. Great VDO as always.

    • @millomweb
      @millomweb 5 років тому

      I'm quite happy with the colour.

  • @scottboomshakalaka9593
    @scottboomshakalaka9593 4 роки тому

    The US has different grade plugs, Hospital, Industrial, etc. does the UK have similar grades?

  • @danielmolan2942
    @danielmolan2942 5 років тому +1

    Hi Clive,
    Mov's break down over time and end up leaking a current to the neutral. I've always sold an low currant circuit breaker to be installed in series, mainly as a cost saving so the surge protector doesn't waste power. Maybe that is why the thermal fuses are there.

  • @timhull8664
    @timhull8664 4 роки тому

    Presumably those springy pins are rated over 13amps, since they may have been designed for a lamp fitting I am not so sure..

  • @iangrice329
    @iangrice329 5 років тому +2

    I like these, use one on battery charger/transformer in caravan, very useful when using a generator.

  • @andy_rulz2000
    @andy_rulz2000 5 років тому

    Awesome video Big Clive, I wish we had these in New Zealand

  • @maxphipps2
    @maxphipps2 5 років тому

    No sound for me when 5.1 audio selected in Win10. Needed to switch to 2CH stereo to get sound in this video. All other videos work fine with 5.1 selected

  • @atlasnetwork7855
    @atlasnetwork7855 Рік тому

    My concern with this design is, is the live going into the surge protector is after the fuse, not before. So if it starts dumping power, is that going to trip the fuse in the plug, preventing the surge protector from doing what it should do? Shouldn't it actually be without a fuse, and without the possibility of wiring to an appliance?

  • @fredflintstone1
    @fredflintstone1 5 років тому

    Are we getting these and the surge protected sockets for when every person is driving an electric car and gets home at 6pm and plugs in the car and makes a cuppa tea and we get a huge surge?? :-)

  • @flow5718
    @flow5718 5 років тому +1

    Does anyone know whey it uses a neon indicator as opposed to an LED? I'd suppose the LED is cheaper and lasts just as long? CMIW.

    • @SenorBolsa
      @SenorBolsa 5 років тому +1

      Neon indicator doesnt require stepping down the voltage, just throw a small resistor in. makes it cheaper for simple things that aren't using a transformer or voltage dropper of some kind to begin with.

    • @flow5718
      @flow5718 5 років тому

      @@SenorBolsa Thank you for the explanation 🙂👍

  • @SteveInScotland
    @SteveInScotland 5 років тому +18

    Clive didn’t checkout the “D”! Well, there’s a first time for everything, rofl

  • @tomsims2998
    @tomsims2998 5 років тому +1

    you could just take an existing plug and swap the back rather then rewiring the entire plug pretty cool

  • @yadt
    @yadt 5 років тому +1

    I don't understand how the MOV marked with a star (between N and E) is any less protected than the MOV between L and E?

    • @waldsteiger
      @waldsteiger 5 років тому

      possibly due to the location of the 2 thermal fuses, one mov doesnt get one.

    • @yadt
      @yadt 5 років тому

      @@waldsteiger but it's symmetric?

    • @Monkeh616
      @Monkeh616 5 років тому +1

      If you have reversed polarity and that MOV fails, there is no thermal fuse to act on it - the one carrying the current is located under the wrong MOV. The fuse will likely still end up opening eventually, but it's not an ideal arrangement. This is however a relatively small risk - we have polarised plugs and generally polarity is correct in our installations.

    • @yadt
      @yadt 5 років тому

      @@Monkeh616 there's a thermal fuse on both the live and neutral terminals. Whether reversed polarity or not, no current can flow without going through a thermal fuse?

    • @waldsteiger
      @waldsteiger 5 років тому

      @@yadt the movs are not protected. its when the mov is already dead or dying (they get hot), then the thermal fuse cuts out to protect the load.

  • @tommyovesen
    @tommyovesen 5 років тому +1

    Why do british plugs have a fuse ? Most other countries (that I know of) do not have fuse in the plugs.

    • @Allstarsoftware
      @Allstarsoftware 5 років тому +2

      As far as I know it's a post war thing when there was a copper shortage so new homes had a ring circuit configuration requiring all plugs to have their own fuses for protection

    • @jrmcferren
      @jrmcferren 5 років тому +3

      British socket circuits are in a Ring Topology to increase capacity and save copper. This increased capacity is far more than is safe for any flexible cord. The overcurrent devices having the increased capacity will not reliably trip quickly enough if there is a fault involving a cord increasing the risk of fire. By adding a fuse in the plug the British were able to safely use smaller cords on their appliances without the risk of fire in the event of a fault. A fuse is also required whenever there is a spur off of a ring in fixed wiring.

    • @Monkeh616
      @Monkeh616 5 років тому +1

      Because of relatively high current (30/32A) ring final circuits. A small flexible cable (up to about 1.5mm²) could fail catastrophically under such currents, so they're fused at the plugs. Most other countries will use 16A, sometimes 20A, circuits, which even a 1mm² or smaller cable is likely to be able to sustain for some time.

    • @111chicane
      @111chicane 5 років тому

      It's a regulation. UK standard. Very thoughtful of them!

    • @Monkeh616
      @Monkeh616 5 років тому

      @@jrmcferren No, a fuse isn't required for a spur. 433.1.204.

  • @Alan_Stinchcombe
    @Alan_Stinchcombe 5 років тому

    Sprung contacts make for ease of manufacture, but what about risk of substantial volt drop across contacts during a high-current burst?

    • @theskett
      @theskett 5 років тому

      The spring contacts are maybe 100 milliohms. The MOVs kick in at 470V. You're not going to get 4700A in any domestic environment, so the spring contact resistance doesn't matter at all.

    • @doring100
      @doring100 5 років тому

      Spring contacts are, say 100 milliohms but are inductive and so their impedance to fast transients will be way more than 0.1Ohm but yea, all good either way

  • @mattbatt0
    @mattbatt0 5 років тому

    I can't figure out how you connect the "flex" from your device into this plug. Am I missing something? Doesn't the power need to go through the protection before it goes to the device?

    • @bigclivedotcom
      @bigclivedotcom  5 років тому +1

      The protection is in parallel it clamps voltage spikes.

  • @Solocat1
    @Solocat1 5 років тому +1

    Nice, a new video on one of my favorite topics..

  • @methanoid
    @methanoid 3 роки тому

    Hi, do these surge protectors stop surges in both directions? I ask as my freezer is on same double socket as my PC and every now and then when the freezer motor kicks in, I get a blank screen and I want to fix that!!!!

    • @bigclivedotcom
      @bigclivedotcom  3 роки тому

      It's probably the slight voltage dip cause by the fridge compressor kicking on. Not something a simple filter will help with.

    • @methanoid
      @methanoid 3 роки тому

      @@bigclivedotcom thanks... I know I can't expect you to... but can you suggest any potential solutions? Its annoying RN but if I want to game its gonna be a "game changer" in all the wrong ways!!

  • @TheFilmWhoWasntThere
    @TheFilmWhoWasntThere Рік тому

    I'm still getting to grips with surge protectors but I do wonder, if they all have a limited lifespan, why are they even built in to some extension leads when I'm assuming they're not easy to replace that way? It would make more sense to me to take a normal extension lead and change the plug on it to one of these plugs with a built-in surge protector, and then when that protector fails, you can simply buy a new head, or is there a reason that's a bad idea?

    • @bigclivedotcom
      @bigclivedotcom  Рік тому +1

      You could do that. A surge protector should last a long time if it isn't on a very spiky supply.

  • @LeifNelandDk
    @LeifNelandDk 5 років тому +5

    I was expecting ".. it might go boingg --- but that's ok"

  • @dl200010
    @dl200010 5 років тому

    I once heard about how bad knock off apple chargers are and I did buy one off of ebay, so I tore both the original and knock off apart. Man, the differences in them! I do not know a lot about circuits, but the difference was night and day.

  • @stupossibleify
    @stupossibleify 5 років тому

    This explains why surge protectors can be a fire risk after initially protecting a surge event

  • @bar10dr
    @bar10dr 5 років тому

    Pictures in this video seems a lot less sharp than usual, have you thought about trying 4k?

    • @bigclivedotcom
      @bigclivedotcom  5 років тому

      4K would be difficult to upload on the outdated Internet services here. I think the camera I was using here was over compressing the images.

  • @drivewasher
    @drivewasher 5 років тому

    If either of the fuses blow? Shurley if just the Nuteral fuse blew the neon would stay lit, would't it?

    • @jrmcferren
      @jrmcferren 5 років тому

      Possible, but also unlikely. For that to occur, the Neutral to Earth MOV would have to be shorted.

  • @asifshuja8638
    @asifshuja8638 3 роки тому

    Can we buy OnLine please?

  • @Io1564
    @Io1564 5 років тому

    But how clever/large is the available contact surface area between the rounded pin tips and the bottom part? These could get really hot when maxed.

    • @Monkeh616
      @Monkeh616 5 років тому

      They don't carry any relevant amount of current in normal operation..

    • @Io1564
      @Io1564 5 років тому

      @@Monkeh616 "in normal operation" which is what, charging yer phone or heating up yer caravan?

    • @Monkeh616
      @Monkeh616 5 років тому

      @@Io1564 Doesn't matter. The load current of the device does not go through those contacts.

  • @peterlarkin762
    @peterlarkin762 5 років тому

    How common are power surges? Is it usually caused by a home appliance or does the surge originate from the supplied mains? Thanks!

    • @bigclivedotcom
      @bigclivedotcom  5 років тому

      Often appliances with high inductive loads like motors can cause spikes.

  • @tobias_mx
    @tobias_mx 5 років тому

    is this video supposed to be muted or why is there no sound?

    • @bigclivedotcom
      @bigclivedotcom  5 років тому

      Check your surround sound settings. Dolby will be sending all the audio to a missing middle speaker.

  • @Almrond
    @Almrond 5 років тому

    PTFE tape wrapped around an eraser is a really good source of pure white for white balance correction without having to pay out the nose for a WB block.

    • @millomweb
      @millomweb 5 років тому

      Is WB such a big issue ?
      I loved the way filming grass from under a blue tarpaulin turns the grass yellow.

  • @phonotical
    @phonotical 5 років тому

    Could you use it on the front end of an extention cord?

    • @Monkeh616
      @Monkeh616 5 років тому +1

      Of course, but you may as well get one with more substantial surge protection built into it..

    • @LeifNelandDk
      @LeifNelandDk 5 років тому

      I'd rather use it at the female end, to get the length of the cable to take the power of the transients when the mov's clamp down.

    • @theskett
      @theskett 5 років тому +1

      @@LeifNelandDk You can certainly do that, but there's not enough impedance in the extension cable (otherwise it'd get hot...) to make any significant difference.

  • @millomweb
    @millomweb 5 років тому

    Would be even neater if they'd not used bayonet socket contacts - as it is them that's driving the height of the plug top.

  • @superdau
    @superdau 5 років тому

    Is there any case where polarized plugs actually are a benefit rather than creating a new safety hazard by relying on the polarization?

    • @MarkTillotson
      @MarkTillotson 5 років тому

      They are always safer as the live is the wire that's fused and switched inside the appliance. Unpolarized plug, appliance switch off, appliance 50% chance of being live inside.

    • @Monkeh616
      @Monkeh616 5 років тому

      @@MarkTillotson Which is irrelevant as there's such a thing as isolation. Functional switching is not the same thing, and if the two are a confusing concept you shouldn't be inside the appliance..

  • @GRBtutorials
    @GRBtutorials 5 років тому +4

    6:55 And in other countries, the plugs aren’t even polarised.

    • @andersfrihagen3656
      @andersfrihagen3656 5 років тому +1

      I was told once upon a time that Norway and Peru are the only countries in the world that has no live/neutral, but both phases have about 130(?) Volts to ground..

    • @petermichaelgreen
      @petermichaelgreen 5 років тому

      @@andersfrihagen3656 www2.theiet.org/forums/forum/messageview.cfm?catid=205&threadid=88103 suggests that such systems are also seen in other parts of Europe and that Norway also uses the normal 230/400 system. The phase-phase voltage is sqrt(3) times the phase to neutral voltage, so with a 230V phase-phase voltage you would have about 133 volts phase to neutral.

  • @heavydiesel
    @heavydiesel 5 років тому +1

    Put some aircon in a shop where the incoming live and neutral were reversed! Customer wasn't bothered, suspect they'd bypassed the meter...

    • @millomweb
      @millomweb 5 років тому

      So was the meter running backwards ? ;)

    • @puckcat22679
      @puckcat22679 5 років тому +5

      I'll do you one better. My boss sent me to one of his rental properties to take a look at why the circuit breaker for the barn out behind the house kept blowing. He had just had some work done there by a "professional electrician." Now, for purposes of understanding the problem, I'll explain a bit about American electrical systems. Most devices use 120 volts, and larger devices such as air conditioners, ovens, etc. use 240 volts. The transformer that supplies the property has a 240 volt secondary that is center tapped, with the center tap being referenced to ground (Earth) and serving as the neutral on 120v circuits. The two live wires go in to the circuit breaker panel (consumer unit) and the bus bars alternate so that every other slot uses one live wire and the others use the other one. For a 240v circuit, you have a double pole circuit breaker with one pole on each of the live wires, so that they have a potential of 240v between each other. When you run electricity to an outbuilding, you'll run 4 wires: live 1, live 2, neutral, and ground (Earth) Those will go to a sub-panel with circuit breakers for the outbuilding, and a large, double pole main breaker supplying that will be in the main breaker box in the house. Back to the story. The "professional electrician" that had done the work previously had installed a new subpanel in the barn. In the process, he had connected one live to one live busbar, as you're supposed to, the other live to the neutral bar, and the neutral to the other live bar. Being a subpanel, the neutral and ground aren't bonded together- that's only done at the service entrance, otherwise you can wind up with the ground carrying current. So the installation didn't just short out as soon as power was connected. The result was that half of the outlets and lighting was wired with reverse polarity, and the other half had 240v instead of 120v. Naturally, the things that were plugged in to those outlets didn't like it. So someone else was sent out to see what was going on. Upon discovering that half the outlets had 240 volts, did he go and look at the panel to try and figure out why? No. He just disconnected those outlets and connected them to the circuits that had 120v, and called it a day. So now, you have reverse polarity at all of the outlets. Long story short, there was a security light that comes on when it gets dark that had been connected to one of the 220v circuits, and was damaged by that, such that it had a short circuit in it when turned on. So every night, it would blow the main breaker- because the circuit breakers in the subpanel were connected to neutral, where they were essentially useless. Fortunately, nothing disastrous happened, but it did take me the better part of two days to 1) figure out what the hell was going on, and 2) get it properly sorted, since I had to rewire half the outlets to connect them to the proper circuits.

  • @paulixus
    @paulixus 5 років тому

    What lamp holder is that with the spring loaded pins? I don't quite get it

    • @millomweb
      @millomweb 5 років тому

      Any you push & twist the bulb to fit it. Normally referred to as 'bayonet'
      upload.wikimedia.org/wikipedia/commons/f/ff/Bayonet_lightbulb_and_socket.jpg

  • @mtootm
    @mtootm 5 років тому

    How about an older model GoPro to film? The more recent models allow live previews, streaming, and controlling the camera from a phone.

    • @bigclivedotcom
      @bigclivedotcom  5 років тому

      Too wide a view. I tried one a while ago.

    • @mtootm
      @mtootm 5 років тому

      @@bigclivedotcom too wide isn't a big issue, but I just remembered you post videos with minimal video editing.
      I bet you could ask us to sample what phones we have. I'm sure some us would be happy to help. Tells us what height from bench, recording area, video camera features needed.

  • @keithking1985
    @keithking1985 5 років тому

    Do varistors clip voltage??

    • @bigclivedotcom
      @bigclivedotcom  5 років тому

      Yes. They conduct above a voltage threshold and are intended to clamp short duration voltage spikes.

  • @Rob1972Gem
    @Rob1972Gem 5 років тому

    How do they protect you device when all the protection is sat on top of the plug and the wires go straight from the plug wire and straight to you device if the protection blows the plug will still work .. i don't get how it protects say my computer against a power surge any power spike is going straight from the power out let onto any device plunged into it

    • @SharkoonBln
      @SharkoonBln 5 років тому

      When a power surge occurs those MOV´s short out the plugs. So the electricity flows through them, and not into your device.

    • @SharkoonBln
      @SharkoonBln 5 років тому

      When a power surge occurs those MOV´s short out the plugs so the electricity runs through them, not into your device.

    • @Rob1972Gem
      @Rob1972Gem 5 років тому

      @@SharkoonBln thanks so it blows the fuse then in the plug

    • @SharkoonBln
      @SharkoonBln 5 років тому +1

      @@Rob1972Gem Those MOV absorb the spike. They get hot while doing this, so they will be fine absorbing spikes, but no long occurence of overvoltage.

    • @Monkeh616
      @Monkeh616 5 років тому

      @@Rob1972Gem No, it shouldn't.
      These are for transient overvoltage protection - very short durations, nothing like enough to blow a fuse.

  • @davepusey
    @davepusey 5 років тому +1

    With an SPD now being installed at the consumer unit, as part of the new 18th edition regulations, these are presumably redundant now?

    • @Monkeh616
      @Monkeh616 5 років тому

      Perhaps, but it doesn't really hurt to have additional clamps.. And, well, they're redundant only in the approximately 0.05% of installations equipped with SPDs so far.

    • @leexgx
      @leexgx 5 років тому

      The more devices that have these will lessen the spike load overall in the house when a spike happens (as the spike will be dissipated among all the plugs that have these on them)

    • @leexgx
      @leexgx 5 років тому

      @@ruben_balea that is true as well

    • @winstontanjonhan
      @winstontanjonhan 5 років тому

      SPD is considered Type 2 protection while the plugs ones are Type 3. Both types are recommended to be used together for better protection. ;)

  • @AntonioClaudioMichael
    @AntonioClaudioMichael 5 років тому

    Interesting video Big Clive

  • @UnrealVideoDuke
    @UnrealVideoDuke 5 років тому

    Pretty sad that it doesn't indicate that the main(replaceable) fuse is blown or not!

  • @Polite_Cat
    @Polite_Cat 5 років тому

    why do surge protectors often use neon indicators instead of LEDs? i imagine they're more expensive, so why use them? i doubt it's because they "look cooler" to the manufacturer.

    • @winstontanjonhan
      @winstontanjonhan 5 років тому

      using LED would require an extra component: diode to prevent reverse current as LEDs cannot stand it ;)

  • @reggiep75
    @reggiep75 5 років тому

    There's nothing like standing on the pins of the delightful British plug in the dark.
    It makes you and everyone else in the house feel alive as you shriek scornful abuse at the idiot who's left a stray plug or two like a Vietcong spike pit. I had to scumbag brothers who'd make such traps for each other and I was often the victim of their wars!

  • @yutan15silvia
    @yutan15silvia 5 років тому

    I can't trust MOV. Is it really effective?🤔

    • @fatnindja
      @fatnindja 5 років тому +1

      A guy tested MOVs, spark gaps, clamp diodes, everything failed except the MOVs. The MOV clamps the spike immediately with absolutely no overshoot. I am not an expert but I heard here and there that MOVs stop working after they receive certain amount of spikes through them. They conduct and overheat and start a fire, that's why they go with thermal fuses. Maybe a ferrite filter is a better option? Maybe a small cap with discharge resistor after the MOV is a good idea, it would take the energy of the spike but would not let it overheat if it fails. Oh wait, that's too expensive ... you know how it goes, plastic metalized wires are our future! :)

  • @gromett
    @gromett 5 років тому

    If I understand this correctly, it will also protect other devices plugged into the same extension lead or those very close on the same ring main?

    • @Monkeh616
      @Monkeh616 5 років тому

      Yes.. no.. maybe? Probably erring more towards yes, but it's a fairly basic level of protection to begin with.

  • @BrendanNutley
    @BrendanNutley 5 років тому

    I might be asking a silly question I'm tired after being dragged around in the sunshine by the wife all day, (I'm on holidays in Spain currently) but if its a standard plug base and the circuit board just sits on the three pins monitoring, how does it surge protect? Surely if the surge protection fails the device connected will keep working provided the 13a fuse is intact.......
    Clive again apologies if I'm missing something or asking a dumb question.
    Regards
    Brendan

    • @theskett
      @theskett 5 років тому

      The MOVs are in parallel with the appliance to be protected, so should shunt out any high-voltage transients. At some point, the MOVs may reach end-of-life, become conductive, trip out the fuses; at that point, the neon will no longer light and (if you check the neon) you'll know to replace the plug-top [so as to get some new MOVs].
      It's not exactly fail-safe (!! :-) but it's probably better than nothin' :-)

    • @petermichaelgreen
      @petermichaelgreen 5 років тому +2

      Nearly all "surge protectors" have this problem, they are parallel connected and do not disconnect the appliance when they fail. So they may absorb some surges, but if a really bad one comes along it will blow out the surge protector and continue it's merry way on to the appliance.

  • @kna60
    @kna60 5 років тому +5

    In one of his video, Photonicinduction stated that English electrical equipment are among the best in the world, maybe he was right..

    • @speedbird073
      @speedbird073 5 років тому +10

      The Welsh, Scottish, and Northern Irish stuff is equally as good.

    • @bdf2718
      @bdf2718 5 років тому +4

      @@speedbird073 The Manx stuff is OK, too.

    • @hamjudo
      @hamjudo 5 років тому +3

      If the US upgraded to an accident reporting protocol that produced and published statistics comparable with British statistics, we could easily tell just how much better.
      Note that the current US administration is actually working to reduce the gathering and timely publishing of accident statistics.

    • @martinda7446
      @martinda7446 5 років тому +2

      @@speedbird073 Cornish and Isle of Dogs too

    • @tonyjones9442
      @tonyjones9442 5 років тому +4

      @@speedbird073 I'm in North wales, electricity hasn't reached us yet. Got a few barrels of whale oil to use first.

  • @frankowalker4662
    @frankowalker4662 5 років тому +5

    So instead of having to rewire your plugs, you could just replace the back of the plug. Nice.

  • @FarleyHillBilly
    @FarleyHillBilly 5 років тому +1

    At 470v your computer is protecting the MOV's,
    I use 275 v big buggers in the extension lead and they haven't gone bang yet. I like the thermal fuses, I shall fit some.

    • @Monkeh616
      @Monkeh616 5 років тому +5

      470V is not the AC rating - it is DC. A 275V DC MOV would spend much of its very short life conducting.

    • @FarleyHillBilly
      @FarleyHillBilly 5 років тому +2

      @@Monkeh616
      They were 20 mm rated 275 VAC.
      Good point noted, read the spec and never assume anything.
      www.electronicdesign.com/power/select-right-varistors-overvoltage-circuit-protection

    • @FarleyHillBilly
      @FarleyHillBilly 5 років тому

      @@Monkeh616
      I wouldn't rely on those springy contact things to stay connected in the event of a big hit.

    • @Monkeh616
      @Monkeh616 5 років тому +1

      @@FarleyHillBilly In the event of a big hit this isn't going to save much anyway - but it can sure help to take the edge off normal grid activities.

    • @FarleyHillBilly
      @FarleyHillBilly 5 років тому

      @@Monkeh616
      It's the abnormal ones that worry me, like an open circuit 3 phase neutral.
      The MOV only has to remain intact long enough to take out a fuse or breaker

  • @ingoditrustcaucasianworth8916
    @ingoditrustcaucasianworth8916 4 роки тому

    Hi.Where can I get that online?

  • @zh84
    @zh84 5 років тому

    Is there a reason why this uses a neon indicator instead of an LED?

    • @bigclivedotcom
      @bigclivedotcom  5 років тому +4

      Simple, efficient and traditional.

    • @markevans2294
      @markevans2294 5 років тому

      An LED would be a lot worst in terms of flicker.

    • @MarkTillotson
      @MarkTillotson 5 років тому

      So the resistor doesn't have to be several watts.

    • @petermichaelgreen
      @petermichaelgreen 5 років тому +1

      LEDs have a couple of issues for mains application, firstly you need a second diode for reverse voltage protection, secondly their current requirements are high enough to make a resistive dropper get uncomfortably hot. You can get around this by using a capacitive dropper instead, but capactive droppers introduce issues of their own which require more components to mitigate.

    • @theskett
      @theskett 5 років тому

      In general, you can replace any neon indicator with two anti-parallel LEDs (or one old tech LED, or one new tech LED with either a series diode or an anti-parallel diode). A milliamp or two is fine, there's no need for a high-wattage resistor nor a capacitive dropper.
      I've done this in a few old power strips, where the neon's blackened enough to be nearly invisible; the (red phosphor) LEDs I used are nice'n'bright.

  • @CutiePatootable
    @CutiePatootable 5 років тому

    big clive!!!! i found you bc i am trying to reprogram some lights i have n had a question..
    i have two strings of lights, led it think, with little control boxes with buttons to change the settings, they can plug together, but don't change to the same setting when one is changed. is there was way to change that in the boxes or would i have to wire them together? thanks!!! these videos are rad

  • @johnbouttell5827
    @johnbouttell5827 5 років тому +2

    It's good to see that The British do some things right.

    • @Alexander_l322
      @Alexander_l322 5 років тому +1

      Up yours.

    • @speedbird073
      @speedbird073 5 років тому +3

      Regrettably, recent experience would indicate that this may no longer be the case.

    • @theskett
      @theskett 5 років тому +1

      @@speedbird073 Came here to say what you said, thank you :-)