WEBINAR: Designing Liquid-Liquid Extraction Columns

Поділитися
Вставка
  • Опубліковано 8 вер 2024

КОМЕНТАРІ • 9

  • @BrianLee-uc2oc
    @BrianLee-uc2oc 23 дні тому

    I learned a tremendous amount, thank you to the speakers and organizers!

  • @Cowboy_Consultants
    @Cowboy_Consultants Рік тому

    awesome webinar!

  • @Zuberzito
    @Zuberzito 3 роки тому

    Thank you very much for this amazing presentation. I will suggest it to my chemical engineering undergraduate students immediately. Please, keep posting videos like this! Regards from Brazil!

  • @DDDelgado
    @DDDelgado Рік тому

    @20:50 explanation on when to use metal or plastic as your internal. Ie packing.

  • @stefraets4024
    @stefraets4024 3 роки тому

    Great webinar guys! Maybe a small question regarding the interface location in packed column. Is the location decided by the bottom valve or by the phase flow-ratio's? Thanks a lot, Stef

    • @publiccalendar9105
      @publiccalendar9105 3 роки тому +1

      Interface control is by the heavy phase outlet (bottom) valve. Interface location (top or bottom) is determined by how you start up the column. First you fill the column with one phase or the other. That sets the continuous phase. Once the column is full of the selected phase, then the other phase is added and it automatically becomes the disperse phase with the interface then set (by the bottom control valve) in the opposite end of the column from where the disperse phase is added.

    • @stefraets4024
      @stefraets4024 3 роки тому

      @@publiccalendar9105 So startup is very important as well as a level instrument? I cant fill up the column with continuous phase for lets say 75% and then startup with the dispersed phase. Afterwards changing the interface with the bottom valve?

  • @saadmosar7423
    @saadmosar7423 3 роки тому

    say i have a petroleum sludge oil.. required to recover oil by solvent extraction .. should i use Batch or centrifugal or tray! or what!

  • @malleswararaoanupoju2357
    @malleswararaoanupoju2357 2 роки тому

    Sir good morning. I am.malleswara rao from vizag, a.p. India. Iam working in solvent recovery system since 10 years. I have a problem Sir. I don't separate methylene di chloride from hexane. Feed analysis is 70%MDC+30%Hexane. So please tell me Sir.