Rashida bhai assalamualaikum Mujhe carrier ke Reefar k baare m jaanna tha 200 td ya 250 td . Ke hote hain. Mera Matlab Jo 12.walt .yaa. 24 Walt se chalte hai...please..
Bahi ek walking chiller hai jis ka back pressure 50 rkha hua hai 2° temp set hai maximum 2 minutes me cutoff hota hai par out door pe aesa hota hai jaese contector puri tarah se disconnect nhi hua continue restart hota rheta hai mai ne contector bhi change kar ke dekha hai kea problem hai bat dijiye meharbani hogi
Bhai ye watch timer manual kese chaltta run kese karta kya 220 v par chalta is me machine kese work karti jaise watch me Betri ki zarorath huthi jaise old watch me tight karty chaui
Sir compressor pe supply timer se jata h ki sub zero se Mera company se 5 ton ka cold room h deepfrosh me jata hai In door fan Band rahata & out door compressor & fan chalu rahta h
Excellent learning lecture.You are great ❤❤❤
@@mukundab123 thanks
Excellent sir
Super sir g
AllhumdulilAllah all good 👍
Bhai cold room kay compressor ka size b bta dein katny hp ka hota ha
Alag Alag HP mai hote hai
Sir ak bar sub zero temperatures controller par new videos banao usake parameter ke satting par
1,2 din mai video upload hogi cold room wiring part -2 usko dekh kar wiring Kar lena kbhi problem nahi aayegi
Nice
Rashida bhai assalamualaikum
Mujhe carrier ke Reefar k baare m jaanna tha 200 td ya 250 td . Ke hote hain. Mera Matlab Jo 12.walt .yaa. 24 Walt se chalte hai...please..
Walaikum Assalaam Whatsapp par contact kro
Thanks sir
Welcome
Assalamualaikum
Bahi ek walking chiller hai jis ka back pressure 50 rkha hua hai 2° temp set hai maximum 2 minutes me cutoff hota hai par out door pe aesa hota hai jaese contector puri tarah se disconnect nhi hua continue restart hota rheta hai mai ne contector bhi change kar ke dekha hai kea problem hai bat dijiye meharbani hogi
LP HP Switch check kro
Walaikum Assalam
Bahar country se video banate hai kya
Han
Cooling coil heater 3phase 220volt ka detail dedo
Ok coming soon video
Sir Kahan se Hai
UP se
Bhai ye watch timer manual kese chaltta run kese karta kya 220 v par chalta is me machine kese work karti jaise watch me Betri ki zarorath huthi jaise old watch me tight karty chaui
Ye video Dekho sab smajh Mai aa jayega .ua-cam.com/video/6I38rtmmWFw/v-deo.html
Sir compressor pe supply timer se jata h ki sub zero se
Mera company se 5 ton ka cold room h deepfrosh me jata hai
In door fan Band rahata & out door compressor & fan chalu rahta h
Wiring check kro
Deforst mai compressor and evaporator fan dono band hona chahiye
Bhai muje uski pic send karo men bta deta hu kya problem he
Model numbers kya hai
Hii
Yes
Excellent sir