DIY CAMPER ELECTRICAL SYSTEM FUSE PLACEMENT

Поділитися
Вставка
  • Опубліковано 28 січ 2023
  • This video will teach you where you need fuses in your DIY Camper Electrical System.
    ➤Shop the EXPLORIST.life Store: shop.explorist.life
    ➤Shop Battle Born Batteries: battlebornbatteries.com?afmc=explorist_bb67
    ➤Binge the Transit Van Build: • The Ultimate Camper Va...
    Here are some additional resources that you may find helpful with planning and installing your DIY Camper:
    ➤DIY Sprinter Camper Van Electrical Install - Full Tutorial: • DIY Sprinter Camper Va...
    ➤DIY Camper Solar Wiring Diagrams: www.explorist.life/solarwirin...
    ➤How to Perform a Power Audit: • How Much Solar Power D...
    ➤Basic Parts & Components of an Electrical System: • Basic Solar Parts Need...
    ➤How to Cut Wire: www.explorist.life/how-to-cut...
    ➤How to Strip Wire: • How to Strip Wire from...
    ➤How to Crimp Wire: • How To Crimp Wire Lugs...
    ➤How to Make MC4 Connectors: • How To Make MC4 Connec...
    ➤How to Wire Solar Panels in Series-Parallel: • How to Wire Solar Pane...
    ➤How to Crimp Wire Ferrules: • How to Crimp Ferrules ...
    ➤How to Wire an AC/DC Breaker/Fuse Box: www.explorist.life/how-to-wir...
  • Авто та транспорт

КОМЕНТАРІ • 158

  • @EXPLORISTlife
    @EXPLORISTlife  Рік тому +10

    *In summary:*
    *1: You need a fuse on the 'battery end' of every positive wire in the system.*
    EXCEPTION:
    1: You don't need fuses on positive wires where there is a fuse upstream that is already protecting it. For example: A 3 way splice for puck lights where all wires are rated for at least the fuse rating upstream.
    ❗My Wiring Diagrams where I've already figured all of this stuff out for you: *www.explorist.life/solarwiringdiagrams*
    A special note for you marine/boat/yacht users: ABYC requires overcurrent protection on the wire coming from your shore power inlet. This is because the shore power pedestals at marinas are subject to salty (corrosive) sea air and faulty breakers in the shore power pedestals are common. This is something we rarely see in the 'Camping' world and is why pretty much no RV's on the road have a breaker on the shore power inlet wire. Here is the specific ABYC standard for that: 11.10.2.5.3 Shore power systems shall have a main shore power disconnect circuit breaker. If the location of the main shore power disconnect circuit breaker is in excess of 10 ft (three meters) from the shore power inlet or the electrical attachment point of a permanently installed shore power cord, additional fuses or circuit breakers shall be provided within 10 ft (three meters) of the inlet or attachment point to the electrical system of the boat. Measurement is made along the conductors.

    • @wademchenry1560
      @wademchenry1560 Рік тому

      I have a VMax 125 solar AGM, the spec. says 8-30 amps charge Input. Will I damage it by using a 6amp charger? THANX

  • @MikeWardNet
    @MikeWardNet Рік тому +4

    Those diagrams could double as art.👍

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +2

      Ha, Thanks! I had some of them printed off and was using them as my video background there for a while.

  • @cowboyyoga
    @cowboyyoga Рік тому +3

    Nate... a super helpful video! This video really helped me see details more clearly. Thanks for breaking everything down, and sharing all your knowledge!

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Awesome! Glad it helped. Thanks for watching!

  • @HuangXingQing
    @HuangXingQing Рік тому

    Another great video. I enjoy watching these because they remind me of details I've not thought of for a spell.

  • @GaryNichols50
    @GaryNichols50 Рік тому +2

    Very timely, Nate. I am just getting to the point of my van build where I need to plan for fuses and wire sizes. I had already made a note to go back and rewatch your wire size video and look for your worksheet. And I was going to see if you had a video on fuse sizes. So, at least for me, this was not at all a "filler video" as you referred to in this morning email newsletter update. Thanks again.

  • @jimhanty8149
    @jimhanty8149 Рік тому

    i just went through this brain twister about fusing the victron 150/100 charger.. it can be tricky... thanks fora great vid....it confirmed alot for me..

  • @Bwanar1
    @Bwanar1 Рік тому

    Excellent description as usual!

  • @jerrym995
    @jerrym995 9 місяців тому +1

    wish i would have found your channel before i started buy my solar parts, you make it much more understandable

  • @kristinf4900
    @kristinf4900 Рік тому +1

    Flawless timing. This is exactly what I am tackling today. Thank you for another excellent video!

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      Glad to help!

    • @PeterBetancourt
      @PeterBetancourt Рік тому +1

      I'm curious Kristin, are you building your own van? If so, would love to share pics and ideas. What model do you have?

  • @MicheleHeinyScott
    @MicheleHeinyScott Рік тому

    Excellent explanation!!

  • @craigj6277
    @craigj6277 Рік тому

    Excellent job, I like how reference the Reg’s.

  • @andyjholloway
    @andyjholloway Рік тому +3

    Great addition to your video collection Nate! This topic took me a long time to get my head around when I did my van last year. Everything else made sense quickly and easily thanks to all your other helpful videos.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Glad it was helpful!

    • @volneymcdove3515
      @volneymcdove3515 Рік тому +1

      @@EXPLORISTlife d0 you have to use. A. Distribuiter

    • @volneymcdove3515
      @volneymcdove3515 Рік тому +1

      @@EXPLORISTlife I. Am. Seaiñg. Some other metwork. Build. Thear. System. Without. A. Distributed. So. Tell. ,,me if. I. Mead. To. Wier. It into. Mine

    • @volneymcdove3515
      @volneymcdove3515 Рік тому

      What. Causes. The. Batry. Ter,inals. To. Coroad. How. Cam. I. Stop this. From. Hapening

  • @CBikeLondon
    @CBikeLondon Рік тому

    Super clear, excellent video. Thank you

  • @christosmaninos1570
    @christosmaninos1570 Рік тому

    Fantastic video explanation. Thanks for sharing.

  • @billc183
    @billc183 Рік тому

    Fantastic Video - very well done

  • @JMX246
    @JMX246 7 місяців тому

    Great info - really well explained - thanks for posting !

  • @saintb6969
    @saintb6969 Рік тому

    Awesome video!

  • @KJC63
    @KJC63 11 місяців тому

    This was great, and exactly what I needed....thank you so much for making the video. I'll be moving my 200amp fuse.

    • @EXPLORISTlife
      @EXPLORISTlife  11 місяців тому

      Awesome! Glad it helped. Thanks for watching!

  • @leandrosphotostudio
    @leandrosphotostudio Рік тому

    Niiice!! Greetings from copan ruinas, Honduras.

  • @OffGridLivingEspana
    @OffGridLivingEspana 5 місяців тому

    good stuff appreciated

  • @gonefilming2020
    @gonefilming2020 Рік тому

    Great video and explanation, Nate! 😊

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Thanks! 😃

    • @gonefilming2020
      @gonefilming2020 7 місяців тому

      @@EXPLORISTlife I have two follow-up question though:
      1. I use 3 separate 100Ah batteries with matching internal 100A (150A burst) rated BMSs. I can calculate proper wire sizes for length and load (450A max), but do I need to use a (300A) fuse with a slower reaction time to compensate for peak current flows?
      2. If one of these batteries experiences a dead short (e.g. an accidental solid connection by a wrench between the positive and negative terminals), will the BMS shut down in time to prevent a violent reaction?
      Thanks in advance for your input and best regards from Germany!

  • @randyschultz6594
    @randyschultz6594 Рік тому

    Great presentation. You covered everything very well.
    I guess for the 30a charge controller I better ensure I have wiring that can handle the 30 amps. In the case of a short neither the wire nor charge controller will care that there is 30amps of current, during a short.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Exactly. In all of our wiring kits w/ 30a chargers, we are using closer to 60A fuses w/ 6ga wire.

  • @PeterBetancourt
    @PeterBetancourt Рік тому

    As always, great content Nate. FYI, I had previously emailed you regarding my battery controller that was not working after getting a new phone and updating it with the Victron app… long story short I was able to reset the battery monitor after fully charging the batteries and resetting the controller. I purchased almost all of the electrical system through your site and now that my van is almost complete I would love to have you look at my system and get your thoughts. Thanks for all you do to help us DIY’s.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Sure! Send the pics of your system you want us to check to the email listed on the bottom of your receipts or start an order support ticket at shop.explorist.life/support

    • @PeterBetancourt
      @PeterBetancourt Рік тому

      @@EXPLORISTlife Sounds great Nate! Been super busy with work and weather here has limited my time to finish up the van. I will work on sending the photos in the next several weeks. Thanks again for your videos and the support you give to us DIY's. You're the best!

  • @GadgetMan777
    @GadgetMan777 4 місяці тому

    Great videos on solar! To simplify, I'd just go with an all-in-one charger/inverter. All these modules is way more complicated.

    • @EXPLORISTlife
      @EXPLORISTlife  4 місяці тому

      All of our systems including everything shown in this video use Inverter/Chargers like the Victron Multiplus. 👍🙂 If you want flexible solar charging options, DC DC Charging options, fuse block options, etc; all of 'these modules' are necessary.
      Modules = Flexibility

  • @natecostello9201
    @natecostello9201 Рік тому +2

    It's worth noting that current flowing from a self-limiting source like a solar charge converter into a short circuit is "safe" as long as the wire is sized with sufficient ampacity to carry that self-limited fault current (which it should be). Yes current will flow, but you will not overheat the wire and/or start a fire. That is one reason for the exception in ABYC that allows not installing overcurrent protection on the charger side of the wire.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      For sure! I talked about that at the 5:00 minute mark in this video.

    • @natecostello9201
      @natecostello9201 Рік тому

      @@EXPLORISTlife We totally agree on the the OCP placement. Perhaps the distinction I'm making vs the video is too subtle: "...but there's still going to be power flowing this direction and that's just how it works and there's really no way to protect against this. Let's say for example this is a 30 amp charge controller that's going to flow 30 amps along these two wires back to our lynx distributor back to our battery Bank. If there's a short circuit that happens here and this fuse blows, power is still going to be flowing this direction at a rate of 30 amps and is going to feed 30 amps to that spot in the wires. Well, that seems kind of dangerous, right? So you know, I mean, that short circuit could potentially heat up and yeah it's absolutely true but there's no way to protect against that..."

  • @RealSenseChannel
    @RealSenseChannel Рік тому

    wouldn't a BMS protect the battery against overcharging, so would I need a fuse? I'm asking cause I made solar system for my Office, and I'm wondering if I need to add fuses, Based on your videos I will add to the inverter connections. I made a video about my set up, and I'm just wondering how I can improve it. Great Explanations by the way!

  • @DJ-jx9mg
    @DJ-jx9mg Рік тому

    In your DIY Sprinter Camper Van Electrical Install - Full Tutorial, your fuse is close to the discount switch. Not close to the batteries. I wired mine this way as well (following the video example). Seems fine. You share here standard is to be close to the source of power. Thoughts on having the fuse closer to the shutoff switch instead of the battery. I might be able to move mine, but right now it is in a good location for mounting. Positive/negative lines are equal distance. Thanks.

  • @FMTFXE22
    @FMTFXE22 Рік тому

    Hi, great information videos. Thanks for all you share. Might you have a video on replacing the standard coach lead acid batteries with the new lithium ion batteries like battle born or another brand. I understand that it’s probably also important to change the standard issue converter / inverter in order to properly charge The lithium ion batteries. And also something called a shunt should be installed so that the battery condition can be monitored. Might you have a video showing how to do that? Thanks again.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      We have wiring diagrams for electrical upgrades in both 30a and 50a OEM RV's at www.explorist.life/solarwiringdiagrams We will have videos covering those by the end of 2023, so stay tuned!

  • @olivierhecht8022
    @olivierhecht8022 Рік тому +5

    I think the first part of the video could be confusing to some people because you describe power flowing “through both wires”. DC circuits (almost all) flow power from the positive side of the power source, through the load, and then back through the ground. Yes there is power going through both wires, but the direction matters and you can’t really short circuit the ground side of the circuit. Clarifying that might help people who are confused about where to put the fuse to remember to always put it on the positive side of the circuit…

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +2

      Sure! That's a good way of thinking of it as well.

  • @olivierhecht8022
    @olivierhecht8022 Рік тому

    Thanks for the overview…how do fuses built into batteries factor in? I assume they’re just extra protection for the small amount of wire between the battery and the main fuse in the system?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      Those are 'usually' fused to protect the internal circuitry of the battery. Depending on how it's set up, it could protect the battery interconnect or battery to busbar wires give the fuse is less than the max ampacity of the wire.
      I don't really like/deal with/recommend those types of batteries, though, so for my system designs it doesn't really matter, personally.

  • @mr.goldenrod291
    @mr.goldenrod291 Рік тому

    Informational video, but consider including source references (ABYC for example) in the video description. No mention of UL Standard 458.
    In any system that interconnects DC (which has the potential of “unlimited” amperage) to AC requires circuit protection because most AC wiring can’t handle DC amperage, thus creating a fire hazard. Many installers and DYIers disregard/don’t understand why the protection is required.
    Circuit protection is more than just fuse/breaker size. It’s also maximum amperage, and the ability to prevent and extinguish an arc.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      UL 458 doesn't pertain to "Where to place fuses" (the topic of this video). If you feel it does, though, that would be a great topic for you to make your own video on! 👍

    • @charliejohnson5762
      @charliejohnson5762 Рік тому

      Mr. G: UL 458 deals with power conversion devices. UL 489 and UL 1077 are the proper documents for OCPD.

  • @marlaineshirley7741
    @marlaineshirley7741 4 місяці тому

    Great tutorial. We have three 120AH lithium 12.8 V LiFePO4 Batteries what size fuse should I put 7 inches from my battery. We are using 2AWG wire to the batteries. We had planned to use a 270 fuse right at the battery terminal. Any help would be wonderful.

  • @wjhann4836
    @wjhann4836 Рік тому

    Nate, as far as I can remember from boats: There is always a fuse right at the input (receptacle) at the stearn. I assume the thought is not to trust some unknown power outlet from outside.
    As another explanation: There are often bigger outlets in the shore box than my ship needs. So people have that (not legal) adapters from 50A plug to our 16A line into the boat.
    That box at start shall protect all the internal wiring - or is responsible for the internal wiring, not pretending on proper fusing outside.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      For sure! Marine shore power pedestals are subject to REALLY harsh salt-water environments that we don't see in campers.
      ABYC has a specific standard for that one: 11.10.2.5.3 Shore power systems shall have a main shore power disconnect circuit breaker. I f the location of the main shore power disconnect circuit breaker is in excess of 10 ft (three meters) from the shore power inlet or the electrical attachment point of a permanently installed shore power cord, additional fuses or circuit breakers shall be provided within 10 ft (three meters) of the inlet or attachment point to the electrical system of the boat. Measurement is made along the conductors.

    • @wjhann4836
      @wjhann4836 Рік тому

      @@EXPLORISTlife Thanks for this info - also valid here in Europe.
      I'm only wondering why there will be different rules for RV - for me technical the same.

    • @gonefilming2020
      @gonefilming2020 Рік тому

      @@EXPLORISTlife Here in Germany (or Europe for that matter) it is MANDATORY BY LAW to add a fuse panel with a GFI 30mA circuit just beyond your external (land line) power feed into a van / motorhome. One should not trust any shoreline install to be properly wired or protected.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      Great! Thanks for the insight. Add it for sure in that case.

  • @cobster79
    @cobster79 Рік тому

    Really great video and good explanation :) byt why do you have ground/chassis connection? as far i can se it wouldnt be a problem to make i a floating system, only that the dc/dc charger should be an isolated model :)

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      A lack of chassis ground connection would make any GFCI outlet not function properly and would take away a good 'return' path of current in the event of a catastrophic system failure.

  • @olivierbourgeois3230
    @olivierbourgeois3230 Рік тому

    Thanks for taking the time to do this. I was wondering, do you recommand any AWG Gauge Size Chart that would match your calculator? I tried to compare with the Blue Sea chart and for some reason, in some cases it doesnt seem to match my findings. So, maybe I'm missing something. I like the shortcuts that your calculator provides but I also want to understand better. Thanks :-)

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      Sure! The ABYC wire sizer app is the one I use to cross-reference.

    • @olivierbourgeois3230
      @olivierbourgeois3230 Рік тому

      @@EXPLORISTlife thanks Nate! Ill look in to it. Looking forward for the rest of your build!! :-)

  • @redwood1957
    @redwood1957 5 місяців тому

    Nice video. your right solar gets confusing. So you do not need to fuse your solar panels on the out put of the solar panel? Now on the input side of the mppt you show an isolation switch. If I have two 200 watt panels feeding back to the 40 amp mppt controller. Each pael runing a pair of wires back, individually meaning 2 positives and 2 negatives one set per solar panel. Could I put them into a y solar connector fitting and then feed the mppt from the y fitting?
    As well i do not have to fuse the out put of the MPPT controller.
    Thank you

    • @EXPLORISTlife
      @EXPLORISTlife  5 місяців тому

      If this video doesn't clear it up, perhaps just sticking with the plans/diagrams we've already pre-designed at shop.exploirst.life will be the safest route.

  • @anonymousrigdon879
    @anonymousrigdon879 Рік тому

    What do I need to set up for shore power? I’m not ready to set up solar

  • @bobbeebobbee6998
    @bobbeebobbee6998 Рік тому

    So every input source from solar panel solar blanket DC/DC need mppt current contrôler then fuse and then to the buss bar and breaker box exept the box 3000 w inverter who manage his own input and output right?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      I'm not quite following that summary. Perhaps watch it again to see where you need to put fuses.

  • @edmor1086
    @edmor1086 Рік тому

    I wonder if the victron charge controller has a way to sense a short circuit and turn off

  • @Mr.J345
    @Mr.J345 Місяць тому

    I currently have a blue sea main disconnect switch between Lynx power in and lynx distributer and the switch is getting hot. Should I replace it with a class t fuse or a blue sea 600amp switch? No loose connections just running 170a continuous I’ve read heats the switches up

  • @salvadorblascogonga8204
    @salvadorblascogonga8204 Рік тому

    Para hacer un camión vivienda taller de 5Kw de inversor que sería mejor , un regulador y batería o inversor contado junto?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      shop.explorist.life/shop/all-products/plans-and-diagrams/solar-wiring-diagrams/400-1400ah-battery-bank-quattro-5000w-24v-inverter-dc-dc-charger-wiring-diagram/

  • @qquizz
    @qquizz 6 місяців тому

    For the batteries, is the fuse for redundancy, since most quality batteries have built-in short circuit protection?

  • @TurboJThomas
    @TurboJThomas 10 місяців тому

    Don’t chargers usually sense shorts and go into fault mode? Is that not your protection from the other side?

  • @PeteLeuenberger
    @PeteLeuenberger 6 місяців тому

    What about including a fuse for each battery, in the event of a battery failure ?

  • @wademchenry1560
    @wademchenry1560 Рік тому

    Can you do some videos on EMP protection?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Like "how to fold a tin-foil hat" type of videos? 😂🤣 jk jk. I don't know much about EMP protection, so those videos are pretty low on the priority list.

    • @rjthomasindyusa
      @rjthomasindyusa Рік тому

      I’m kind of concerned about having a big electrical system in a big metal box (van) myself. Especially since I will be sleeping right over the top of it....

  • @fightswithspirits915
    @fightswithspirits915 Рік тому

    Some folks say negative wires need fuse s and cut-off protection. Any idea why?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      It's just a different way/method of designing systems. It's pretty atypical, though, and is not how I design systems. I've looked into it before, and there are too many 'gotchas' for me to be comfortable with a negative switched/fused system and, I believe, is not allowed by ABYC.

  • @psl53
    @psl53 4 місяці тому

    I have a very simple electrical system. I have a 30 amp solar controller that I've placed a 30 amp fuse within 7" of the positive output of the controller. I also have my converter at the rear and Batteries up front that has a 4 awg wire running to the battery that I believe will carry current to the Batteries for charging, but also carry the current from the batteries to the 12v distribution panel. Why wouldn't want a fuse at either end to limited the amount of power. I should never have more than 50 amps running through this wire.

    • @psl53
      @psl53 4 місяці тому

      Think I have it, The solar controller and Convert/charger are self-limiting. I'll fuse the loads individually and fuse the unlimited power battery bank. Thanks

  • @charliejohnson5762
    @charliejohnson5762 Рік тому

    Nate: Good video but……..ABYC requires OCPD within 10’ of the shore power inlet. We simply don’t trust the pedestal breaker in the marine environment. Further, that “unprotected” 10’ of wire inside the boat has some very specific requirements levied on it to ensure it’s physical integrity and to mitigate the possibility of a short circuit.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      Great! For sure! That has been something I've gone back and forth on because we rarely have faulty shore power pedestals in campgrounds like you boat/yacht guys do in the marine world since our shore power pedestals aren't subject to salty sea air. I'll add that info and the related standard to the pinned comment for those watching these videos for marine installations. Thanks Charlie!

  • @theadley2002
    @theadley2002 Рік тому

    If I have a 200 amp hour battery bank. What size main fuse would I need?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      It depends on what loads you are running and what wire sizes you are using. search back a bit on our channel for 'how to size wires' and 'how to size fuses' videos. Or visit www.explorist.life/solarwiringdiagrams for more specific examples

  • @1unihipili
    @1unihipili Рік тому

    Question!!! What brand and type of assorted washers do you use? Ty.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Just general use washers? Whatever is cheap at the local hardware store.

    • @1unihipili
      @1unihipili Рік тому

      Thx. I thought maybe it would not be cheap. Everything that you have used is quality and expensive. I' m good though if cheap is good with you. Thx again.

  • @williambell8282
    @williambell8282 Рік тому +1

    I have seen a Victron video which instructed you to feed shorepower through a domestic AC breaker before being connected to a MultiPlus. Then the AC power out from the MultiPlus goes back through a domestic breaker before being distributed to AC sockets. This a new one on me. Up to then I had assumed that that the shore power cable went directly to the MultiPlus and then to the domestic breaker box. What do you think?

    • @CS30123
      @CS30123 Рік тому

      The shore power connection is already on a breaker at the pedestal.

    • @charliejohnson5762
      @charliejohnson5762 Рік тому +1

      Experienced marine electricians consider the pedestal breaker as suspect and basically an on/off switch. This is the reason that ABYC requires OCPD within 10’ of the shore power inlet.

    • @natecostello9201
      @natecostello9201 Рік тому +2

      @@charliejohnson5762 This is the way.

    • @charliejohnson5762
      @charliejohnson5762 Рік тому

      @@natecostello9201 Sorry, I don't understand your comment.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Thanks all! I added some additional info/context to the pinned comment regarding this. Here's the copy/paste:
      A special note for you marine/boat/yacht users: ABYC requires overcurrent protection on the wire coming from your shore power inlet. This is because the shore power pedestals at marinas are subject to salty (corrosive) sea air and faulty breakers in the shore power pedestals are common. This is something we rarely see in the 'Camping' world and is why pretty much no OEM RV's on the road have a breaker on the shore power inlet wire.
      Here is the specific ABYC standard for that:
      11.10.2.5.3 Shore power systems shall have a main shore power disconnect circuit breaker. If the location of the main shore power disconnect circuit breaker is in excess of 10 ft (three meters) from the shore power inlet or the electrical attachment point of a permanently installed shore power cord, additional fuses or circuit breakers shall be provided within 10 ft (three meters) of the inlet or attachment point to the electrical system of the boat. Measurement is made along the conductors.

  • @ErwinDay-oq1sf
    @ErwinDay-oq1sf Місяць тому

    Can I start the Multiplus 12/3000, with Orion TR DC - DC charger using default settings temporarily until I get a MK3 to USB connector to download software for programming the inverter?

    • @EXPLORISTlife
      @EXPLORISTlife  Місяць тому

      You could turn it on; but I wouldn't power any loads or try to charge from shore.

    • @ErwinDay-oq1sf
      @ErwinDay-oq1sf Місяць тому

      @@EXPLORISTlife Thanx

  • @kevinanderson9243
    @kevinanderson9243 11 місяців тому

    Could you do a wiring schematic for 4 Heliene 360watt panels going into 2 Renogy Rover 40A charge controllers? I split the array bc the controllers are rated at 1040 watts for a 24v battery bank ...3 panels are 1080 watts so I split them into 2 groups of 2. I'm wiring a camper so for the purpose of weight distribution I put 6 batteries over the left axle and across the hall I put 6 batteries over the right side of the axle. The batteries are 55ah gel batteries with each pair wired in series then in parallel with the next pair for 3 sets of 2 batteries then connected to the other group of 6 batteries across the hall...wire length between the 2 groups approximately 6 feet. All series/parallel connections are done with 6 awg wire. The panels have the following tolerances...
    360 watts
    Voltage MPP-37.3
    Current MPP-9.65
    VOC-45.3
    Current SC -10.18
    Max System Rating-1000V
    Fuse Rating-15A
    Thank you for taking the time to look this over.
    Cheers

    • @EXPLORISTlife
      @EXPLORISTlife  11 місяців тому

      Here is a video that will show you how to wire multiple solar arrays/charge controllers: ua-cam.com/video/N0UB7LZVduk/v-deo.html

  • @wellyzz4963
    @wellyzz4963 8 місяців тому

    hi sir . how can we calculate the fuse size for 2 battery 200 ah. as sample in parralel

  • @simon359
    @simon359 Рік тому

    Can you use two fuses for the batteries, one on the terminal and one before the power cut off battery switch? 🖖

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      What additional protection do you feel that would offer?

    • @simon359
      @simon359 Рік тому

      @@EXPLORISTlife
      In case one didn’t blow the other one might?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Adding redundancies like that is not necessary if you are using high-quality and appropriately sized fuses.

    • @daniellel256
      @daniellel256 Рік тому

      Nate, another great video. As a follow up, can you discuss the different fuses, ANL versus a T fuse. Why use one instead of another? Where to use what type of fuses? Thanks for all the work you guys put into these videos.

  • @Maxtcee1
    @Maxtcee1 Рік тому

    Hey been watching your channel for quite sometime and I'm currently doing my catamaran but I'm at a information overload right now. Would love your help if you got time

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      For sure! I've made all kinds of videos here on this channel that 'help'. Or if you have a question, you can always leave it here in the comments section and I'll point you in the right direction.
      Unfortunately, I don't have time for 1 on 1 consulting or installation services and still run this channel , if that's what you were getting at.

    • @Maxtcee1
      @Maxtcee1 Рік тому

      @@EXPLORISTlife currently Im adding four 545w mono half to the three 160w mono that came with the boat. I'm connecting each 545s to separate 100/50 MPPT and the 160s to 1 mppt. Replacing the 4 amg house batteries for four 330ah lithium batteries and keeping 2 amg starter batteries which will be connected to 4 Orion DC to DC chargers. I'm also adding another 12/2000 multi to the one that came with the boat which is where I'm getting stuck at . Not sure if I should run them in parallel or series. Right now we keep tripping the breaker if we run the heat and microwave or kettle and microwave. So what would be my best option as to be able to use everything without tripping breakers ?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      If both units are feeding the same 'phase' of the breaker box, you'll want to set them up in parallel. If you have a split phase (L1 and L2) breaker box, you'll want to set them up in split phase. If both your microwave and your kettle and you heater are all on the same side/phase of the breaker box, that might be a breaker box limitation if that's where the breakers are tripping. I don't have any specific videos about any of this, but that is the direction I'd recommend you investigate.

    • @Maxtcee1
      @Maxtcee1 Рік тому

      @@EXPLORISTlife hey thanks for the response, so the breaker that actually trips is from the shore power on the marina side . I believe it's a 30amp breaker which is weird because my inverter is an 80amp inverter.

  • @ErwinDay-oq1sf
    @ErwinDay-oq1sf 2 місяці тому

    I did the power audit. Results suggested I add a 400W system with a 3000W Inverter and 200 Ahr battery bank. Spent A LOT of money on components. Have a 270 Ahr Battle Born BBGC3 battery with Victron MultilPlus 12/3000 Inverter. Of course first thing I discover after purchase when I read the manual, Page 8, "recommended battery capacity (Ah) 400 - 1200. The MultiPlus Quick istallation guide shows a frame with a main battery and trickle battery going to the inverter. Adding a 100 AH battery would get me to 370 Ah. That's close to 400 Ar. I am broke. Any ideas?

    • @EXPLORISTlife
      @EXPLORISTlife  2 місяці тому

      Batteries in the same battery bank must be the same size; so you'll need to either add an additional 270Ah battery or return that one and go with 4x100Ah batteries to get to that 400Ah minimum.

    • @ErwinDay-oq1sf
      @ErwinDay-oq1sf 2 місяці тому

      @@EXPLORISTlife this was my thoughts as well. I returned to where I purchased the system. Salesmans assured me that the 270Ah battery was sufficient for the Multiplus 12/3000 to work and further said he would call Battleborn Battery rep to confirm this. Should I be wary of his statements?

    • @EXPLORISTlife
      @EXPLORISTlife  2 місяці тому

      @@ErwinDay-oq1sf I'm not comfortable with discrediting the way another company does business. All I can share is what we do within our own business which is based on years of building these systems with 1,000's of successful builds behind us and the understanding that both Battle Born and Victron Energy contract us to teach about these systems. Would love to have you as our customer in the future so we can make sure you get what you need.
      Ultimately, whoever you buy your equipment from is responsible for providing tech support and any warranty repairs/exchanges, so if they are willing to back up those two things on a purposefully undersized battery bank, that's on them.

  • @davidgreen9957
    @davidgreen9957 Рік тому

    Why not use MRBF Terminal Fuses?

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Those are great fuses as well! We have those in our "smaller" systems where we can use 300A fuses (since the largest MRBF fuse is only 300A): shop.explorist.life/shop/all-products/camper-wiring-kits/complete-wiring-kits/wiring-diagram-kits/200-1000ah-battery-bank-multiplus-2k-12v-orion-12-12-30-wiring-diagram-kit/

  • @richardthames661
    @richardthames661 3 місяці тому

    I was curious can I just pay you guys for a wiring diagram

    • @EXPLORISTlife
      @EXPLORISTlife  3 місяці тому

      We have diagrams available for each of our systems we have pre designed over at shop.explorist.life

  • @CS30123
    @CS30123 Рік тому +1

    Why does a 100 amp fuse protect the DC block when using 6awg wire? 6 gauge wire isn't rated for 100 amps.

    • @noxikid
      @noxikid Рік тому

      Because fuse heats up and blows out faster than a wire. So if you'll have 95 amps short circuit, it could not protect it right. But shorts are often conduct much more power than a wire can handle for few seconds.

    • @CS30123
      @CS30123 Рік тому +1

      @@noxikid uhh...thats not how circuit protection works lol. You use a fuse/breaker designed to protect the max amp load a wire can hold safely. 100 amps is like 30 amps past what 6awg is rated for. Its just a mistake. We dont have to do PR work for Explorist. Everyone fucks up.

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      No mistake there. 🙂 6ga wire with 105 degree insulation is rated for 120A.

  • @markjackson6829
    @markjackson6829 Рік тому

    I'm sorry, but you can protect the wiring of a 30A charge controller very close to it with a 35-40 amp circuit breaker or fuse, with the proper wire size! As I have done many time in the past, nothing is unprotectable with the correct knowledge!

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому +1

      No you can't. A 30A charge controller will NEVER NEVER NEVER put out enough current to trip a 40A breaker. Remember, mark, just because "you've done it" doesn't mean it's correct. You can always change your thinking to something more correct. Hope this helps clear up your confusion. I encourage you to re-watch this video from the viewpoint of learning instead of arguing and sharing incorrect information.

    • @markjackson6829
      @markjackson6829 Рік тому +2

      @@EXPLORISTlife OK, re-watched video, and now I agree, and will stop adding a circuit breaker in that position, thanks!

  • @jeffkurowski638
    @jeffkurowski638 Рік тому

    Dont fuses go in a fuse holder.

  • @rocrat8671
    @rocrat8671 Рік тому

    A solar controller or a dc/dc charger is no different to a battery , it should have circuit protection. You can say a battery is a self limited power source as well , just much bigger then an mppt controller or dc/dc charger . Take a look at all the suggested install diagrams from Victron energy which you use a lot

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Hey there, champ! You sure are confidentially incorrect. 🙂👍 If what you are saying was true, the system that Victron contracted me to design and install in their tour trailer last year was incorrectly installed. You'd think they would have corrected me if I were wrong. Fun fact: you can find some of my diagrams published on the Victron website if you know where to look. Hope this helps clear up your confusion, buddy!

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      But actually, how about this. You can install a fuse on both end of the wire if you like. The rest of us will do it correctly.

    • @charliejohnson5762
      @charliejohnson5762 Рік тому +1

      @ Roc Rat: You are interpreting the standards incorrectly. A battery’s available short circuit current is vastly, like really vastly greater than a charging source. For instance, a Lifeline 4D has ASCC of 5800A. A 120A alternator can only output 120A, even in a short circuit condition.

    • @rocrat8671
      @rocrat8671 Рік тому

      @@charliejohnson5762 Charlie , what difference does it make if it’s 5800 A or 120A it should still be protected , look at a tig welder , you can melt metal at 11vdc and 50A , the question is can you afford a dead short without any circuit protection? Most people can’t

    • @EXPLORISTlife
      @EXPLORISTlife  Рік тому

      Roc... you can't protect a dead short on a current limited device. You are going to need to stop spreading misinformation. I'm just going to have to start deleting your comments until you take the time to educate yourself.
      Thanks for the additional insight and example, Charlie!

  • @HoveyFarms
    @HoveyFarms Рік тому

    Your website on a mobile device is kinda a pain in the ass ngl