Bhai onli outdoor ka line Kitna metre use hisab se Mein Kitna gas dalo aur outdoor Mein Kitna gas dalta hai outdoor ki line Kitna metre ka Usko Mein calculator Karke Kitna Paisa Hai gas ko outdoor mein charge karun
E04 Communication failure between indoor and outdoor units. Detected indoors. Likely cause split A/C=indoor PCB, outdoor PCB, interconnecting cable condition, compressor klixon open circuit. VRF system=power loss at condenser, U1/U2 network cable condition
H02 High amps drawn by compressor on start-up. Detected at outdoor. Likely cause imbalance in voltage supplied to compressor from IPDU board, compressor locked / seized. For VRF fault sub-code required to determine which compressor suffered failure 01=compressor1 02=compressor2 03=compressor3. Retrieve fault sub-code from condenser interface PCB by placing rotary dials to position 1 / 1 / 1 for diagnosis.
Video aap ka bhot hi achch hai,
Bhai reset or test mode ka video banao
Full video banayen commissioning ka gas charging ke sath
Mere ko is topic per bhaiya jaldi video dena
Bhai heat mode deactivate karsakte kya.
Super bro thank you
Very good information.Bhai
Bhai commissioning pe banayea please
Bhai 16hp ka fan pcb chheyai meel jayai ga keetni ka hai
Toshiba vrf me mujhe ek hi mode chalana hai ,cooling ya heating to ye kese set kre plz btaye jldi
Toshiba vrf remote ke bare ke bare mein bhi function batao
Jo pipe line mein liquid kaise calculat krna hai agar pipe line jyada distance hai outdoor and AHU ka
Sir ager toshiba vrf ki pcb chahiye ho to kha se le or ager repair karwani ho to kha se karwaye delhi ya iske aas pass ho to batana plz
Arun bhai toshiba vrf indoor unit ki new pcb lagane per nahi chal rahi hai, uski setting bataiye.
Outdoor say addressing dalo
Rotary switch full detail video
Very good
Sir e19 ka kya problem Hai sir
Bhai PMV moter indoor unit ka kaise check karte hai DN Code sea our kitna open rahna chaheyea.
VRF Toshiba remote function video dalo
Bhai E 28 ka solution btao
Informative
Bhai onli outdoor ka line Kitna metre use hisab se Mein Kitna gas dalo aur outdoor Mein Kitna gas dalta hai outdoor ki line Kitna metre ka Usko Mein calculator Karke Kitna Paisa Hai gas ko outdoor mein charge karun
Rotary switch and dip switch ka full information video
Good
Nice
Thanks Bhai
Sir vaikum mode ka code bataiye
Please error
Good wark
Section PSI mein minimum aur discharge PS minimum kitni honi chahie
E04 and H02 what is the problem can you explain thanks
E04 Communication failure between indoor and outdoor units. Detected indoors. Likely cause split A/C=indoor PCB, outdoor PCB, interconnecting cable
condition, compressor klixon open circuit. VRF system=power loss at condenser, U1/U2 network cable condition
H02
High amps drawn by compressor on start-up. Detected at outdoor. Likely cause imbalance in voltage supplied to compressor from IPDU board,
compressor locked / seized. For VRF fault sub-code required to determine which compressor suffered failure 01=compressor1 02=compressor2
03=compressor3. Retrieve fault sub-code from condenser interface PCB by placing rotary dials to position 1 / 1 / 1 for diagnosis.
Please channel subscribe and share
What is the klaxon can you explain @@electricalmaintenanceandhv7019
Electrical and mechanical parts
PL=???
123 se nahi × karna h 145 se × karna h okay rong video please sahi jankariyaan diya karo yrrr
Good